Haiquan Feng
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Haiquan Feng has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
Tianqi Wang
School of Mechanics and Aeronautics, Inner Mongolia University of Technology, Hohhot, China
4 shared publicationsXiaotian Wang
The First Affiliated Hospital of University of Science and Technology of China, Hefei, PR China
4 shared publicationsHaoxiang Feng
School of Materials Science and Technology, Nanjing University of Aeronautics and Astronautics, Nanjing, People’s Republic of China
3 shared publicationsJuan Su
School of Materials Science and Engineering, Inner Mongolia University of Technology, Hohhot, China
3 shared publications- Juan Su
School of Materials Science and Engineering, Inner Mongolia University of Technology, Hohhot 010051, PR China
3 shared publications Kun Wang
College of Mechanical Engineering, Inner Mongolia University of Technology, Hohhot 010000, PR China
3 shared publications
Latest Publications
- 28 July 2026
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 54 (11) , 4066-4081
Computational Corrosion Modeling for Biodegradable Magnesium Alloy Stents: Progress, Challenges, and Future Directions
- 28 July 2026
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 54 (11) , 4066-4081
Computational Corrosion Modeling for Biodegradable Magnesium Alloy Stents: Progress, Challenges, and Future Directions
- 13 January 2026
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 176, 107349
The influence of the screw configuration of the distal fibular plate on the biomechanics of lateral malleolar oblique fractures
- 13 January 2026
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 176, 107349
The influence of the screw configuration of the distal fibular plate on the biomechanics of lateral malleolar oblique fractures
- Top Cited Papers
- 17 February 2025
- Published by Springer Nature in Journal of Biological Physics
- Vol. 51 (1) , 1-31
Hemodynamics of asymmetrically stenotic vertebral arteries based on fluid–solid coupling
The study investigates the interaction between vertebral artery stenosis and pulsatile blood flow, with a focus on the mechanical properties and internal dynamics of blood flow. First, an asymmetrical stenosis mathematical model was established to reveal the relationship between the resistance ratio and shear stress ratio and their dependence on stenosis height and length. Next, various stenosis models were constructed using medical imaging data and analyzed through computational fluid dynamics (CFD) and fluid–structure interaction (FSI) methods. Finally, hemodynamic parameters, such as blood flow velocity and time-averaged wall shear stress (TAWSS), along with solid mechanics indicators, including total deformation and von Mises stress, were evaluated. The results indicate that changes in stenosis length and height significantly affect the resistance ratio and shear stress. Whole-segment stenosis in the vertebral artery may lead to thrombosis and intimal damage. In contrast, stenosis at the ostium of the vertebral artery increases the risk of platelet deposition on the vessel wall, potentially triggering atherosclerosis. This could ultimately lead to insufficient blood flow to the brain due to impaired vertebral artery circulation. FSI simulations revealed that elastic vessel walls are more sensitive to high-velocity flows, especially in stenotic and downstream regions. These findings provide critical insights into the effects of stenosis on blood flow and are crucial for developing effective clinical intervention strategies.
- 17 February 2025
- Published by Springer Nature in Journal of Biological Physics
- Vol. 51 (1) , 1-31
Top Cited PapersHemodynamics of asymmetrically stenotic vertebral arteries based on fluid–solid coupling
The study investigates the interaction between vertebral artery stenosis and pulsatile blood flow, with a focus on the mechanical properties and internal dynamics of blood flow. First, an asymmetrical stenosis mathematical model was established to reveal the relationship between the resistance ratio and shear stress ratio and their dependence on stenosis height and length. Next, various stenosis models were constructed using medical imaging data and analyzed through computational fluid dynamics (CFD) and fluid–structure interaction (FSI) methods. Finally, hemodynamic parameters, such as blood flow velocity and time-averaged wall shear stress (TAWSS), along with solid mechanics indicators, including total deformation and von Mises stress, were evaluated. The results indicate that changes in stenosis length and height significantly affect the resistance ratio and shear stress. Whole-segment stenosis in the vertebral artery may lead to thrombosis and intimal damage. In contrast, stenosis at the ostium of the vertebral artery increases the risk of platelet deposition on the vessel wall, potentially triggering atherosclerosis. This could ultimately lead to insufficient blood flow to the brain due to impaired vertebral artery circulation. FSI simulations revealed that elastic vessel walls are more sensitive to high-velocity flows, especially in stenotic and downstream regions. These findings provide critical insights into the effects of stenosis on blood flow and are crucial for developing effective clinical intervention strategies.
- 15 December 2024
- Published by Elsevier in Engineering Failure Analysis
- Vol. 169
Reliability analysis and Multiaxial fatigue test of nitinol peripheral artery stent under physiological loads
- 15 December 2024
- Published by Elsevier in Engineering Failure Analysis
- Vol. 169
Reliability analysis and Multiaxial fatigue test of nitinol peripheral artery stent under physiological loads
- 3 December 2024
- Published by Wiley in International Journal for Numerical Methods in Biomedical Engineering
- Vol. 41 (1) , e3895
The Influence Mechanism of Screw Internal Fixation on the Biomechanics of Lateral Malleolus Oblique Fractures
It remains inconclusive about the stability and optimal fixation scheme of screw internal fixation for lateral malleolus oblique fractures in clinical practice. In this study, the effects of different screw internal fixation methods on the biomechanics of lateral malleolus oblique fractures were investigated. These efforts are expected to lay a theoretical foundation for the selection of internal fixation methods and rehabilitation training regimens in the treatment of lateral malleolus fractures. A healthy ankle joint model and a lateral malleolus fracture internal fixation model were established based on CT data with the aid of some software. Besides, the effects of screw internal fixation modalities on the fracture displacement of fibula fractures, fibula Von Mises stress, and screw Von Mises stress under different physiological conditions and loading conditions were investigated using finite element methods (FEMs) and in vitro physical experiments. The double screw vertical fibular axis internal fixation approach had the lowest fracture displacement of fibula fractures and screw Von Mises stress values; while the double screw vertical fracture line internal fixation approach had the lowest fibula Von Mises stress values. Under different physiological conditions, the magnitude of the peak Von Mises stress of the fibula and screw was ranked as plantarflexion 20° > plantarflexion 10° > neutral position > dorsiflexion 10° > dorsiflexion 20°; and the magnitude of the peak displacement of the fibula fracture breaks was ranked as plantarflexion 20° > plantarflexion 10° > neutral position > dorsiflexion 20° > dorsiflexion 10°. The results of in vitro physical experiments and finite element analyses were in good agreement, which validated the validity of finite element analyses. The vertical fracture line screw implantation method displays a better load‐sharing ability; while the vertical fibular axis screw implantation method exhibits a better ability to prevent axial shortening of the fibula and also reduces the risk of screw fatigue damage. Overall, the double screw achieves better therapeutic effects than the single screw. Given that the ankle joint has high stability in the dorsiflexion position, it is recommended to prioritize dorsiflexion rehabilitation training, rather than dorsiflexion and plantarflexion rehabilitation training with too large angles, in the treatment of lateral malleolus fractures.
- 3 December 2024
- Published by Wiley in International Journal for Numerical Methods in Biomedical Engineering
- Vol. 41 (1) , e3895
The Influence Mechanism of Screw Internal Fixation on the Biomechanics of Lateral Malleolus Oblique Fractures
It remains inconclusive about the stability and optimal fixation scheme of screw internal fixation for lateral malleolus oblique fractures in clinical practice. In this study, the effects of different screw internal fixation methods on the biomechanics of lateral malleolus oblique fractures were investigated. These efforts are expected to lay a theoretical foundation for the selection of internal fixation methods and rehabilitation training regimens in the treatment of lateral malleolus fractures. A healthy ankle joint model and a lateral malleolus fracture internal fixation model were established based on CT data with the aid of some software. Besides, the effects of screw internal fixation modalities on the fracture displacement of fibula fractures, fibula Von Mises stress, and screw Von Mises stress under different physiological conditions and loading conditions were investigated using finite element methods (FEMs) and in vitro physical experiments. The double screw vertical fibular axis internal fixation approach had the lowest fracture displacement of fibula fractures and screw Von Mises stress values; while the double screw vertical fracture line internal fixation approach had the lowest fibula Von Mises stress values. Under different physiological conditions, the magnitude of the peak Von Mises stress of the fibula and screw was ranked as plantarflexion 20° > plantarflexion 10° > neutral position > dorsiflexion 10° > dorsiflexion 20°; and the magnitude of the peak displacement of the fibula fracture breaks was ranked as plantarflexion 20° > plantarflexion 10° > neutral position > dorsiflexion 20° > dorsiflexion 10°. The results of in vitro physical experiments and finite element analyses were in good agreement, which validated the validity of finite element analyses. The vertical fracture line screw implantation method displays a better load‐sharing ability; while the vertical fibular axis screw implantation method exhibits a better ability to prevent axial shortening of the fibula and also reduces the risk of screw fatigue damage. Overall, the double screw achieves better therapeutic effects than the single screw. Given that the ankle joint has high stability in the dorsiflexion position, it is recommended to prioritize dorsiflexion rehabilitation training, rather than dorsiflexion and plantarflexion rehabilitation training with too large angles, in the treatment of lateral malleolus fractures.
- 18 February 2024
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 247, 108094
A comparative study on the deformation behavior and mechanical properties of new lower extremity arterial stents
- 18 February 2024
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 247, 108094
A comparative study on the deformation behavior and mechanical properties of new lower extremity arterial stents
- 6 January 2024
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 170, 107968
Mechanism of effect of stenting on hemodynamics at iliac vein bifurcation
- 6 January 2024
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 170, 107968
Mechanism of effect of stenting on hemodynamics at iliac vein bifurcation
- 29 October 2023
- Published by Elsevier in Foot and Ankle Surgery
- Vol. 30 (2) , 135-144
Numerical simulations of the effect of lateral malleolus fracture malunion on ankle biomechanics: Different offset directions and offsets
- 29 October 2023
- Published by Elsevier in Foot and Ankle Surgery
- Vol. 30 (2) , 135-144
Numerical simulations of the effect of lateral malleolus fracture malunion on ankle biomechanics: Different offset directions and offsets
- 20 March 2023
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 51 (6) , 1136-1146
Analysis of Fatigue Strength and Reliability of Lower Limb Arterial Stent at Different Vascular Stenosis Rates and Stent-to-Artery Ratios
In order to study the influence of different vascular stenosis rates and stent-to-artery ratios on the fatigue strength and reliability of lower limb arterial stents, numerical simulation was conducted for the fatigue strength of complete SE stents under pulsating loads using a finite element method. Then, fracture mechanics and conditional probability theory were adopted for mathematical modeling, whereby analyzing the crack growth rate and reliability with stents of different thickness (0.12, 0.15, and 0.18 mm) at different vascular stenosis rates (30, 50, and 70%) and stent-to-artery ratios (80, 85, and 90%). The study found: all three stents of different thickness failed to meet 10-year service life at three vascular stenosis rates; all three stents of different thickness met 10-year service life at three stent-to-artery ratios. With increased vascular stenosis rate, the elastic strain of stents was increased, while the fatigue strength was decreased; with increased stent-to-artery ratio, the elastic strain of the stent was increased, while the reliability of the stent was reduced. After the stent with an initial crack was implanted into the vessel, the crack length underwent non-linear growth with increased pulsating cyclic loads. When the pulsating load reached 3 × 108, the growth rate of the crack on the stent surface increased exponentially, leading to a rapid decrease in reliability. Vascular stenosis rate, stent release ratio, and support thickness have significant effects on crack length propagation rate and reliability. Determining the influence of vascular stenosis rate and stent-to-artery ratio on the fatigue strength and reliability of stents provides a valuable reference for evaluating the fracture failure rate and safety of stents.
- 20 March 2023
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 51 (6) , 1136-1146
Analysis of Fatigue Strength and Reliability of Lower Limb Arterial Stent at Different Vascular Stenosis Rates and Stent-to-Artery Ratios
In order to study the influence of different vascular stenosis rates and stent-to-artery ratios on the fatigue strength and reliability of lower limb arterial stents, numerical simulation was conducted for the fatigue strength of complete SE stents under pulsating loads using a finite element method. Then, fracture mechanics and conditional probability theory were adopted for mathematical modeling, whereby analyzing the crack growth rate and reliability with stents of different thickness (0.12, 0.15, and 0.18 mm) at different vascular stenosis rates (30, 50, and 70%) and stent-to-artery ratios (80, 85, and 90%). The study found: all three stents of different thickness failed to meet 10-year service life at three vascular stenosis rates; all three stents of different thickness met 10-year service life at three stent-to-artery ratios. With increased vascular stenosis rate, the elastic strain of stents was increased, while the fatigue strength was decreased; with increased stent-to-artery ratio, the elastic strain of the stent was increased, while the reliability of the stent was reduced. After the stent with an initial crack was implanted into the vessel, the crack length underwent non-linear growth with increased pulsating cyclic loads. When the pulsating load reached 3 × 108, the growth rate of the crack on the stent surface increased exponentially, leading to a rapid decrease in reliability. Vascular stenosis rate, stent release ratio, and support thickness have significant effects on crack length propagation rate and reliability. Determining the influence of vascular stenosis rate and stent-to-artery ratio on the fatigue strength and reliability of stents provides a valuable reference for evaluating the fracture failure rate and safety of stents.