James Lee
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
James Lee has a total of 77 co-authors. Here are the top co-authors by number of shared publications:
- Dee Dee Wang
Naples Comprehensive Health Naples Florida USA
6 shared publications - Brian O'NEill
Center for Structural Heart Disease Henry Ford Health System Detroit Michigan USA
5 shared publications - Pedro Arturo Villablanca
Center for Structural Heart Disease, Henry Ford Health System, Detroit, Michigan, USA
4 shared publications - Tiberio Michele Frisoli
Center for Structural Heart Disease, Henry Ford Health System, Detroit, Michigan, USA
4 shared publications - Marvin H. Eng
Banner University Medical Center, 1111 East McDowell Road, Phoenix, AZ 85006, USA
3 shared publications William O'NEill
2 shared publications
Latest Publications
- 5 December 2022
- Published by Elsevier in European Journal of Surgical Oncology
- Vol. 49 (4) , 794-801
Disparities in hepatocellular carcinoma survival by Medicaid-status: A national population-based risk analysis
- 5 December 2022
- Published by Elsevier in European Journal of Surgical Oncology
- Vol. 49 (4) , 794-801
Disparities in hepatocellular carcinoma survival by Medicaid-status: A national population-based risk analysis
- 8 September 2022
- Published by Elsevier in The Journal of Heart and Lung Transplantation
- Vol. 41 (12) , 1790-1797
Evaluating predicted heart mass in adolescent heart transplantation
- 8 September 2022
- Published by Elsevier in The Journal of Heart and Lung Transplantation
- Vol. 41 (12) , 1790-1797
Evaluating predicted heart mass in adolescent heart transplantation
- Open Access
- 1 July 2022
- Published by Elsevier in Cardiovascular Revascularization Medicine
- Vol. 40, 1-10
Network Meta-Analysis Comparing the Short- and Long-Term Outcomes of Alternative Access for Transcatheter Aortic Valve Replacement
- 1 July 2022
- Published by Elsevier in Cardiovascular Revascularization Medicine
- Vol. 40, 1-10
Open AccessNetwork Meta-Analysis Comparing the Short- and Long-Term Outcomes of Alternative Access for Transcatheter Aortic Valve Replacement
- 21 February 2022
- Published by Elsevier in JACC: Cardiovascular Interventions
- Vol. 15 (4) , S57
CRT-700.10 Aortic Valve Area and Prosthesis-Patient Mismatch Estimated by Echocardiography Versus Computed Tomography for Transcatheter Aortic Valve Replacement
- 21 February 2022
- Published by Elsevier in JACC: Cardiovascular Interventions
- Vol. 15 (4) , S57
CRT-700.10 Aortic Valve Area and Prosthesis-Patient Mismatch Estimated by Echocardiography Versus Computed Tomography for Transcatheter Aortic Valve Replacement
- Open Access
- 1 November 2021
- Published by Oxford University Press (OUP) in Open Forum Infectious Diseases
- Vol. 8 (Supplement) , S446
688. Incidence and Risk Factors for Prosthetic Valve Endocarditis Following TAVR: 2015-2019
Transcatheter aortic valve replacement (TAVR) is increasingly used for lower risk patients. Incidence of TAVR endocarditis ranges from 0.2% to 3.3%. The purpose of this study was to determine local incidence and risk factors of prosthetic valve infective endocarditis (PVIE) in a contemporary cohort. IRB approved retrospective, nested case-control study evaluated the 1-year incidence and risk factors for PVIE among TAVR recipients from 2015 to 2019. Inclusion: ≥ 18 years, TAVR procedure at Henry Ford Health System. Exclusion: repeat TAVR. PVIE cases were matched with controls who did not experience PVIE. PVIE defined as diagnosis documentation in the electronic medical record. Figure 1. Study Design 23/1266 patients were identified as cases corresponding to a 1-year incidence of 1.82%. The median time to PVIE was 127 days and 35% occurred within 60 days. The most frequently isolated organisms were streptococci (26%), MRSA (13%), and MSSA (13%). Baseline demographics and comorbidities for 23 PVIE cases and 161 controls are displayed in Table 1. Significant risk factors for PVIE in bivariate analysis included STS-PROM (Society of Thoracic Surgeons Predicted Risk of Mortality), median: 4.1 controls and 6.4 cases (p = 0.012). Age, BMI, and comorbidities were not significantly different. Diabetes was notably more frequent among cases (36% vs 48%, p = 0.274). Patients with PVIE had more post-op RBC transfusions (5% vs 21.7% p = 0.003), ECG changes (23% vs 43.5%, p = 0.035), heart block (15.5% vs 34.8%, p = 0.038), longer length of stay (2 days, range 1 to 4 vs 4 to 11, p = 0.004), and thirty-day readmission (10.6% vs 52.2%, p < 0.001). Results displayed in Table 2. Table 1. Patient Characteristics and Risk Factor Analysis Table 2. Additional Outcomes The results from this study give insight to the local incidence, microbiology, and risk of PVIE following TAVR. Future directions include a larger evaluation of modifiable risks such as diabetes management and examining the heart block patients who received permanent pacemaker implants. Rachel Kenney, PharmD, Medtronic, Inc. (Other Financial or Material Support, spouse is an employee and shareholder) Janet F. Wyman, DNP, CNS-BC, FACC, Edwards Lifesciences (Consultant) Dee Dee Wang, MD, Edwards LifeSciences (Consultant) Brian O'Neill, MD, Edwards Lifesciences (Consultant)
- 1 November 2021
- Published by Oxford University Press (OUP) in Open Forum Infectious Diseases
- Vol. 8 (Supplement) , S446
Open Access688. Incidence and Risk Factors for Prosthetic Valve Endocarditis Following TAVR: 2015-2019
Transcatheter aortic valve replacement (TAVR) is increasingly used for lower risk patients. Incidence of TAVR endocarditis ranges from 0.2% to 3.3%. The purpose of this study was to determine local incidence and risk factors of prosthetic valve infective endocarditis (PVIE) in a contemporary cohort. IRB approved retrospective, nested case-control study evaluated the 1-year incidence and risk factors for PVIE among TAVR recipients from 2015 to 2019. Inclusion: ≥ 18 years, TAVR procedure at Henry Ford Health System. Exclusion: repeat TAVR. PVIE cases were matched with controls who did not experience PVIE. PVIE defined as diagnosis documentation in the electronic medical record. Figure 1. Study Design 23/1266 patients were identified as cases corresponding to a 1-year incidence of 1.82%. The median time to PVIE was 127 days and 35% occurred within 60 days. The most frequently isolated organisms were streptococci (26%), MRSA (13%), and MSSA (13%). Baseline demographics and comorbidities for 23 PVIE cases and 161 controls are displayed in Table 1. Significant risk factors for PVIE in bivariate analysis included STS-PROM (Society of Thoracic Surgeons Predicted Risk of Mortality), median: 4.1 controls and 6.4 cases (p = 0.012). Age, BMI, and comorbidities were not significantly different. Diabetes was notably more frequent among cases (36% vs 48%, p = 0.274). Patients with PVIE had more post-op RBC transfusions (5% vs 21.7% p = 0.003), ECG changes (23% vs 43.5%, p = 0.035), heart block (15.5% vs 34.8%, p = 0.038), longer length of stay (2 days, range 1 to 4 vs 4 to 11, p = 0.004), and thirty-day readmission (10.6% vs 52.2%, p < 0.001). Results displayed in Table 2. Table 1. Patient Characteristics and Risk Factor Analysis Table 2. Additional Outcomes The results from this study give insight to the local incidence, microbiology, and risk of PVIE following TAVR. Future directions include a larger evaluation of modifiable risks such as diabetes management and examining the heart block patients who received permanent pacemaker implants. Rachel Kenney, PharmD, Medtronic, Inc. (Other Financial or Material Support, spouse is an employee and shareholder) Janet F. Wyman, DNP, CNS-BC, FACC, Edwards Lifesciences (Consultant) Dee Dee Wang, MD, Edwards LifeSciences (Consultant) Brian O'Neill, MD, Edwards Lifesciences (Consultant)
- 1 August 2021
- Published by HMP Communications, LLC in Journal of Invasive Cardiology
- Vol. 33 (8) , E670-E671
Left Atrial Appendage Occlusion With the LAmbre Device: First-in-Human in the United States
The LAmbre device offers an alternative for patients who may not qualify for conventional LAA occlusion devices. We describe its use in a 79-year-old male patient with non-valvular atrial fibrillation and multiple falls who was considered high risk for anticoagulation therapy. from Journal of Invasive Cardiology. Cardiac Imaging Left atrial appendage
- 1 August 2021
- Published by HMP Communications, LLC in Journal of Invasive Cardiology
- Vol. 33 (8) , E670-E671
Left Atrial Appendage Occlusion With the LAmbre Device: First-in-Human in the United States
The LAmbre device offers an alternative for patients who may not qualify for conventional LAA occlusion devices. We describe its use in a 79-year-old male patient with non-valvular atrial fibrillation and multiple falls who was considered high risk for anticoagulation therapy. from Journal of Invasive Cardiology. Cardiac Imaging Left atrial appendage
- 1 September 2020
- Published by Elsevier in Clinical Neurology and Neurosurgery
- Vol. 196, 105970
Non-invasive cerebral perfusion monitoring in cardiac arrest patients: a prospective cohort study
- 1 September 2020
- Published by Elsevier in Clinical Neurology and Neurosurgery
- Vol. 196, 105970
Non-invasive cerebral perfusion monitoring in cardiac arrest patients: a prospective cohort study
Eighty-two-year-old man with a systolic murmur
Clinical Introduction An 82-year-old man with a history of coronary artery bypass surgery, hypertension and small bowel gastrointestinal stromal tumour underwent cardiac risk evaluation prior to surgical resection of his tumour. He was asymptomatic from a cardiovascular perspective, but his activity level was less than four metabolic equivalents. Physical examination was notable for a 2/6 systolic murmur at the apex. ECG showed sinus rhythm. A transthoracic echocardiogram was performed (figure 1 and online supplementary video 1). Transthoracic echocardiography. (A) Mitral valve continuous wave Doppler and (B) tricuspid valve continuous wave Doppler. QUESTION: The findings in figure 1 are most likely due to which of the following? Atrioventricular conduction block. Acute severe aortic regurgitation. Patent ductus arteriosus. Atrial flutter. Severe mitral stenosis.
Eighty-two-year-old man with a systolic murmur
Clinical Introduction An 82-year-old man with a history of coronary artery bypass surgery, hypertension and small bowel gastrointestinal stromal tumour underwent cardiac risk evaluation prior to surgical resection of his tumour. He was asymptomatic from a cardiovascular perspective, but his activity level was less than four metabolic equivalents. Physical examination was notable for a 2/6 systolic murmur at the apex. ECG showed sinus rhythm. A transthoracic echocardiogram was performed (figure 1 and online supplementary video 1). Transthoracic echocardiography. (A) Mitral valve continuous wave Doppler and (B) tricuspid valve continuous wave Doppler. QUESTION: The findings in figure 1 are most likely due to which of the following? Atrioventricular conduction block. Acute severe aortic regurgitation. Patent ductus arteriosus. Atrial flutter. Severe mitral stenosis.