Matthias U. Schafroth
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Matthias U. Schafroth has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Arthur J. Kievit
Department of Orthopaedic Surgery and Sport Medicine Amsterdam UMC (Location AMC) Amsterdam The Netherlands
3 shared publications - Leendert Blankevoort
Department of Orthopaedic Surgery and Sport Medicine Amsterdam UMC (Location AMC) Amsterdam The Netherlands
3 shared publications - A. M. J. S. Vervest
Department of Orthopaedic Surgery, Tergooi Hospital, Hilversum, Netherlands
2 shared publications - Daniel Haverkamp
Department of Orthopaedic Surgery, Slotervaart Hospital, Amsterdam, The Netherlands
2 shared publications - Dirk Das
Department and Research Center of Orthopaedic Surgery, St. Anna Hospital, Geldrop, Netherlands
2 shared publications - Marco J. M. Hoozemans
Department of Human Movement Sciences, Faculty of Behavioural and Movement Sciences, Vrije Universiteit Amsterdam, Amsterdam Movement Sciences, Amsterdam, The Netherlands
2 shared publications
Latest Publications
- Open Access
- 3 June 2026
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
Increased radiolucency on conventional radiographs around tibial components does not imply more load‐induced displacement of a total knee arthroplasty
Purpose: After total knee arthroplasty (TKA), radiolucent lines on routine conventional radiographs are commonly interpreted as impaired tibial component fixation, although their relation to implant motion remains unclear. This necessitates a comparison with measured component displacement. Recently, a computed tomography (CT)‐based method measuring load‐induced tibial component displacement has been introduced. This study aimed to determine whether the extent of radiolucent lines observed on radiographic imaging truly implicates displacement of tibial components. Methods: Conventional radiographs and CT‐scans of 50 hybrid posterior stabilised TKA's with a cemented tibial baseplate were included in a post‐market 10‐year follow‐up study. The extent of radiolucent lines on conventional radiographs was classified according to the Modern Knee Society, by two independent raters, creating three subgroups: ‘none', ‘partial', and ‘complete'. Subsequently, load‐induced implant displacement was quantified using CT‐scans under valgus‐varus loading. Relative implant displacement was quantified using rotation about the helical axis, Maximum Total Point Motion (MTPM), and mean target registration error (mTRE). Hypothesising similar displacement between subgroups despite differences in radiolucency, a Two One‐Sided Tests (TOST) procedure, using the Smallest Detectable Change (SDC) as equivalence margins, was conducted. Statistical equivalence would indicate the subgroups showed similar displacement. Results: Median displacement values were comparable across subgroups. Median rotation ranged from 0.60 to 0.79 degrees, median MTPM from 0.59 to 0.85 mm, and median mTRE from 0.44 to 0.53 mm across the subgroups. Statistical equivalence was confirmed in eight of nine comparisons, indicating that the subgroups were similar. The comparison of mTRE between the ‘partial' and ‘complete' subgroups did not meet statistical equivalence ( p = 0.053). The inter‐observer Cohen's Kappa for subgroup classification was 0.95 (95% confidence interval: 0.84–1.00). Conclusion: These findings suggest that a greater number of radiolucent lines does not represent more load‐induced displacement of tibial components of TKA. This limits the diagnostic value of radiolucent lines for assessing tibial component fixation. Level of Evidence: Level III.
- 3 June 2026
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
Open AccessIncreased radiolucency on conventional radiographs around tibial components does not imply more load‐induced displacement of a total knee arthroplasty
Purpose: After total knee arthroplasty (TKA), radiolucent lines on routine conventional radiographs are commonly interpreted as impaired tibial component fixation, although their relation to implant motion remains unclear. This necessitates a comparison with measured component displacement. Recently, a computed tomography (CT)‐based method measuring load‐induced tibial component displacement has been introduced. This study aimed to determine whether the extent of radiolucent lines observed on radiographic imaging truly implicates displacement of tibial components. Methods: Conventional radiographs and CT‐scans of 50 hybrid posterior stabilised TKA's with a cemented tibial baseplate were included in a post‐market 10‐year follow‐up study. The extent of radiolucent lines on conventional radiographs was classified according to the Modern Knee Society, by two independent raters, creating three subgroups: ‘none', ‘partial', and ‘complete'. Subsequently, load‐induced implant displacement was quantified using CT‐scans under valgus‐varus loading. Relative implant displacement was quantified using rotation about the helical axis, Maximum Total Point Motion (MTPM), and mean target registration error (mTRE). Hypothesising similar displacement between subgroups despite differences in radiolucency, a Two One‐Sided Tests (TOST) procedure, using the Smallest Detectable Change (SDC) as equivalence margins, was conducted. Statistical equivalence would indicate the subgroups showed similar displacement. Results: Median displacement values were comparable across subgroups. Median rotation ranged from 0.60 to 0.79 degrees, median MTPM from 0.59 to 0.85 mm, and median mTRE from 0.44 to 0.53 mm across the subgroups. Statistical equivalence was confirmed in eight of nine comparisons, indicating that the subgroups were similar. The comparison of mTRE between the ‘partial' and ‘complete' subgroups did not meet statistical equivalence ( p = 0.053). The inter‐observer Cohen's Kappa for subgroup classification was 0.95 (95% confidence interval: 0.84–1.00). Conclusion: These findings suggest that a greater number of radiolucent lines does not represent more load‐induced displacement of tibial components of TKA. This limits the diagnostic value of radiolucent lines for assessing tibial component fixation. Level of Evidence: Level III.
- Open Access
- 12 September 2024
- Published by Elsevier in The Journal of Arthroplasty
- Vol. 40 (3) , 625-631
Predictive Validity of the Work, Osteoarthritis, or Joint Replacement Questionnaire for Return to Work After Total Knee Arthroplasty: A 12-Month Multicenter Prospective Cohort Study
- 12 September 2024
- Published by Elsevier in The Journal of Arthroplasty
- Vol. 40 (3) , 625-631
Open AccessPredictive Validity of the Work, Osteoarthritis, or Joint Replacement Questionnaire for Return to Work After Total Knee Arthroplasty: A 12-Month Multicenter Prospective Cohort Study
- Open Access
- 9 September 2022
- Published by Springer Nature in Journal of Occupational Rehabilitation
- Vol. 33 (2) , 267-276
Does Consulting an Occupational Medicine Specialist Decrease Time to Return to Work Among Total Knee Arthroplasty Patients? A 12-Month Prospective Multicenter Cohort Study
Purpose: The aim of this study is to investigate whether total knee arthroplasty (TKA) patients who consulted an occupational medicine specialist (OMS) within 3 months after surgery, return to work (RTW) earlier than patients who did not consult an OMS. Methods: A multi-center prospective cohort study was performed among working TKA patients, aged 18 to 65 years and intending to RTW. Time to RTW was analyzed using Kaplan Meier and Mann Whitney U (MWU), and multiple linear regression analysis was used to adjust for effect modification and confounding. Results: One hundred and eighty-two (182) patients were included with a median age of 59 years [IQR 54–62], including 95 women (52%). Patients who consulted an OMS were less often self-employed but did not differ on other patient and work-related characteristics. TKA patients who consulted an OMS returned to work later than those who did not (median 78 versus 62 days, MWU p < 0.01). The effect of consulting an OMS on time to RTW was modified by patients’ expectations in linear regression analysis (p = 0.05). A median decrease in time of 24 days was found in TKA patients with preoperative high expectations not consulting an OMS (p = 0.03), not in patients with low expectations. Conclusions: Consulting an OMS within 3 months after surgery did not result in a decrease in time to RTW in TKA patients. TKA patients with high expectations did RTW earlier without consulting an OMS. Intervention studies on how OMSs can positively influence a timely RTW, incorporating patients’ preoperative expectations, are needed.
- 9 September 2022
- Published by Springer Nature in Journal of Occupational Rehabilitation
- Vol. 33 (2) , 267-276
Open AccessDoes Consulting an Occupational Medicine Specialist Decrease Time to Return to Work Among Total Knee Arthroplasty Patients? A 12-Month Prospective Multicenter Cohort Study
Purpose: The aim of this study is to investigate whether total knee arthroplasty (TKA) patients who consulted an occupational medicine specialist (OMS) within 3 months after surgery, return to work (RTW) earlier than patients who did not consult an OMS. Methods: A multi-center prospective cohort study was performed among working TKA patients, aged 18 to 65 years and intending to RTW. Time to RTW was analyzed using Kaplan Meier and Mann Whitney U (MWU), and multiple linear regression analysis was used to adjust for effect modification and confounding. Results: One hundred and eighty-two (182) patients were included with a median age of 59 years [IQR 54–62], including 95 women (52%). Patients who consulted an OMS were less often self-employed but did not differ on other patient and work-related characteristics. TKA patients who consulted an OMS returned to work later than those who did not (median 78 versus 62 days, MWU p < 0.01). The effect of consulting an OMS on time to RTW was modified by patients’ expectations in linear regression analysis (p = 0.05). A median decrease in time of 24 days was found in TKA patients with preoperative high expectations not consulting an OMS (p = 0.03), not in patients with low expectations. Conclusions: Consulting an OMS within 3 months after surgery did not result in a decrease in time to RTW in TKA patients. TKA patients with high expectations did RTW earlier without consulting an OMS. Intervention studies on how OMSs can positively influence a timely RTW, incorporating patients’ preoperative expectations, are needed.
- 31 October 2011
- Published by Wiley
- p. 898-904
Snapping Hip