Ravi Prakash Tewari
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Ravi Prakash Tewari has a total of 30 co-authors. Here are the top co-authors by number of shared publications:
- Shahid Suhail Narvi
Motilal Nehru Natl Inst Technol Allahabad, Dept Chem, Prayagraj 211004, Uttar Pradesh, India
3 shared publications - Aarti Sharma
Department of Information Technology, Indira Gandhi Delhi Technical University for Women, Church Road, Kashmere Gate, 110006, Delhi, New Delhi, India
2 shared publications - Dhanesh Tiwary
Indian Institute of Technology (Banaras Hindu University)
2 shared publications - Jaynendra Kumar Rai
Department of ECE, ASET, Amity University, Noida, Uttar Pradesh, India
2 shared publications Poushpi Dwivedi
2 shared publications- Ramesh Pandey
Motilal Nehru National Institute of Technology Allahabad
2 shared publications
Latest Publications
- 11 January 2026
- Published by Wiley in Advanced Engineering Materials
- Vol. 28 (5)
A Morphological Study on Femtosecond Laser Machining of Thin NiTi Sheet for Biomedical Application: Parameter Optimization to Device Fabrication
The present work originates from the need for optimizing the efficient machining of a thin superelastic NiTi sheet (0.2 mm) using a laser. The low austenite‐finish temperature (–3.32 °C), high superelastic limit (5.97%), and elastic modulus of NiTi (31.9 GPa) make it compatible for the fabrication of dental splints (DS). The optimization of femtosecond laser parameters is performed using a Taguchi L 8 array. The kerf taper is found to depend primarily on laser speed, with a higher kerf width at the entry side than at the exit side. Material removal at the kef entry and exit is dominated by vaporization of the material and shearing action of the argon gas. An insignificant effect of heat near the cut surface is observed, as the wt% of Ni (44.1–48.47%) and Ti (35.19–38.32%) is nearer to pristine NiTi (Ni: 49.65%, Ti: 38.59%). Based on the optimization results, the smallest kerf taper is obtained at 6 mm s −1 , 200 kHz, and 20 μJ pulse −1 . DS is fabricated using these optimized parameters. The morphology is observed to exhibit no surface cracking and DS with the smallest interaperture distance achieves the highest strength and stiffness. Hence, the article illustrates the approach to design optimization of NiTi alloy medical structures, which can serve as a useful guideline for the fabrication of medical devices.
- 11 January 2026
- Published by Wiley in Advanced Engineering Materials
- Vol. 28 (5)
A Morphological Study on Femtosecond Laser Machining of Thin NiTi Sheet for Biomedical Application: Parameter Optimization to Device Fabrication
The present work originates from the need for optimizing the efficient machining of a thin superelastic NiTi sheet (0.2 mm) using a laser. The low austenite‐finish temperature (–3.32 °C), high superelastic limit (5.97%), and elastic modulus of NiTi (31.9 GPa) make it compatible for the fabrication of dental splints (DS). The optimization of femtosecond laser parameters is performed using a Taguchi L 8 array. The kerf taper is found to depend primarily on laser speed, with a higher kerf width at the entry side than at the exit side. Material removal at the kef entry and exit is dominated by vaporization of the material and shearing action of the argon gas. An insignificant effect of heat near the cut surface is observed, as the wt% of Ni (44.1–48.47%) and Ti (35.19–38.32%) is nearer to pristine NiTi (Ni: 49.65%, Ti: 38.59%). Based on the optimization results, the smallest kerf taper is obtained at 6 mm s −1 , 200 kHz, and 20 μJ pulse −1 . DS is fabricated using these optimized parameters. The morphology is observed to exhibit no surface cracking and DS with the smallest interaperture distance achieves the highest strength and stiffness. Hence, the article illustrates the approach to design optimization of NiTi alloy medical structures, which can serve as a useful guideline for the fabrication of medical devices.
- 19 April 2024
- Published by National Taiwan University in Biomedical Engineering: Applications, Basis and Communications
- Vol. 36 (02)
DIFFERENT APPROACHES IN BONE TISSUE ENGINEERING: ADVANTAGES AND DISADVANTAGES
Human bone tissue damage arises due to defects, injury, tumors, aging, and traffic accidents. It is one of the most challenging issues that need surgical development and advanced bone implants. Biocomposite-based bone has insufficient blood supply restricting the utilization for bone regeneration. It is often overcome by including scaffold having angiogenic factor delivery, in vitro and in vivo pre-vascularization. Bone and endothelial cell development and proliferation are stimulated by magnetic responsive scaffolds containing magnetic nanoparticles. Its porous structure allows cells to communicate and develop in all directions, which improves osteointegration. Scaffolds without seeded cells might have applications in bone tissue engineering (BTE) and it is mandatory to estimate in vitro and in vivo biocompatibility and degradation behavior. Three-dimensional (3D) printing opens the door to the creation of one-of-a-kind shapes and structures with specific properties. It helps to minimize the spread of germs during synthesis stage. The gamma rays minimize the infection communicated during transplantation but also damage the graft. When it comes to choosing biomaterials for cancellous and cortical bones, an artificial neural network has the highest recognition rate. This review paper explores the different potential approaches for bone grafting. Different techniques have been developed to create hydrogels with desirable properties for BTE, including non-toxicity, biocompatibility, controllability, and performance. A cell-free framework is used to stimulate bone regeneration, which helps in the bone the self-healing processes of bone fractures. The recent approach combines TE, material science, and genetic engineering for enhanced vascularization, restoring blood flow, and preventing cell death.
- 19 April 2024
- Published by National Taiwan University in Biomedical Engineering: Applications, Basis and Communications
- Vol. 36 (02)
DIFFERENT APPROACHES IN BONE TISSUE ENGINEERING: ADVANTAGES AND DISADVANTAGES
Human bone tissue damage arises due to defects, injury, tumors, aging, and traffic accidents. It is one of the most challenging issues that need surgical development and advanced bone implants. Biocomposite-based bone has insufficient blood supply restricting the utilization for bone regeneration. It is often overcome by including scaffold having angiogenic factor delivery, in vitro and in vivo pre-vascularization. Bone and endothelial cell development and proliferation are stimulated by magnetic responsive scaffolds containing magnetic nanoparticles. Its porous structure allows cells to communicate and develop in all directions, which improves osteointegration. Scaffolds without seeded cells might have applications in bone tissue engineering (BTE) and it is mandatory to estimate in vitro and in vivo biocompatibility and degradation behavior. Three-dimensional (3D) printing opens the door to the creation of one-of-a-kind shapes and structures with specific properties. It helps to minimize the spread of germs during synthesis stage. The gamma rays minimize the infection communicated during transplantation but also damage the graft. When it comes to choosing biomaterials for cancellous and cortical bones, an artificial neural network has the highest recognition rate. This review paper explores the different potential approaches for bone grafting. Different techniques have been developed to create hydrogels with desirable properties for BTE, including non-toxicity, biocompatibility, controllability, and performance. A cell-free framework is used to stimulate bone regeneration, which helps in the bone the self-healing processes of bone fractures. The recent approach combines TE, material science, and genetic engineering for enhanced vascularization, restoring blood flow, and preventing cell death.
- 18 October 2022
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part E: Journal of Process Mechanical Engineering
- Vol. 237 (3) , 1036-1063
Analysis of rotary ventricular assist devices using CFD technique—A Review
With the increasing focus on reducing deaths because of heart ailments, considerable emphasis has been directed toward the development of ventricular assist devices (VADs) that work on the principle of mechanical pumps for supporting an infirm heart. The VADs are used primarily to assist the left ventricle, but their use has been extended for supporting the right ventricle as well as for supporting both ventricles simultaneously. In this connection, computational fluid dynamics (CFD) has evolved as an efficient technique for the design, development, evaluation, and optimization of VADs, enabling the prediction of operational characteristics of VADs as well as detailed global and local flow characteristics for an extensive set of working environments even before the manufacture and use of the actual device. CFD techniques yield valuable insight into the VADs’ effectiveness that enhances its operational behavior and decreases the risk associated with the use of the device, and at the same time decreases the manufacturing lead time and costs associated with the device. CFD has been quite beneficially used for the performance evaluation of VADs, but it still needs further development as hemolysis and thrombosis models cannot be easily integrated with the flow simulations. This review article presents abrief introduction to rotary VADs with a primary focus on the current status of CFD analysis of axial VADs, which provide the most suitable methods for computational design and optimization of VADs. It also identifies critical knowledge gaps and outlines the hematological models and the difficulties encountered in integrating them into CFD. Finally, future work based on the current scenario is also included.
- 18 October 2022
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part E: Journal of Process Mechanical Engineering
- Vol. 237 (3) , 1036-1063
Analysis of rotary ventricular assist devices using CFD technique—A Review
With the increasing focus on reducing deaths because of heart ailments, considerable emphasis has been directed toward the development of ventricular assist devices (VADs) that work on the principle of mechanical pumps for supporting an infirm heart. The VADs are used primarily to assist the left ventricle, but their use has been extended for supporting the right ventricle as well as for supporting both ventricles simultaneously. In this connection, computational fluid dynamics (CFD) has evolved as an efficient technique for the design, development, evaluation, and optimization of VADs, enabling the prediction of operational characteristics of VADs as well as detailed global and local flow characteristics for an extensive set of working environments even before the manufacture and use of the actual device. CFD techniques yield valuable insight into the VADs’ effectiveness that enhances its operational behavior and decreases the risk associated with the use of the device, and at the same time decreases the manufacturing lead time and costs associated with the device. CFD has been quite beneficially used for the performance evaluation of VADs, but it still needs further development as hemolysis and thrombosis models cannot be easily integrated with the flow simulations. This review article presents abrief introduction to rotary VADs with a primary focus on the current status of CFD analysis of axial VADs, which provide the most suitable methods for computational design and optimization of VADs. It also identifies critical knowledge gaps and outlines the hematological models and the difficulties encountered in integrating them into CFD. Finally, future work based on the current scenario is also included.
- 9 September 2022
- Published by Springer Nature
- p. 199-208
A Review on Magnetorheological Fluids and Its Application in Lower-limb Prosthetic Devices
- 9 September 2022
- Published by Springer Nature
- p. 199-208
A Review on Magnetorheological Fluids and Its Application in Lower-limb Prosthetic Devices
- 12 July 2022
- Published by Taylor & Francis
- p. 153-166
Nanobiotechnological Biomass Conversion into Other Metallic Nanostructures
Nanobiotechnological Biomass Conversion into Other Metallic Nanostructures - 1
- 12 July 2022
- Published by Taylor & Francis
- p. 153-166
Nanobiotechnological Biomass Conversion into Other Metallic Nanostructures
Nanobiotechnological Biomass Conversion into Other Metallic Nanostructures - 1
- 22 February 2022
- Published by Taylor & Francis in Materials Technology
- Vol. 37 (13) , 2503-2516
Antibacterial, Structural, and Mechanical Properties of MgO/ZnO Nanocomposites and its HA-Based Bio-Ceramics; Synthesized via Physio-Chemical Route for Biomedical Applications
The present work reports a novel method for fabricating nanocomposites (NCs) using Magnesium Oxide (MgO) and Zinc Oxide (ZnO) nanoparticles (NPs) via modified sol-gel route. Furthermore, hydroxyapatite was composited with MgO/ZnO NCs to form (HA)-based bio-ceramics (BCs) with enhanced antibacterial and mechanical properties. X-ray diffraction, Fourier transform infrared spectroscopy, field emission scanning electron and transmission electron microscopy, and energy-dispersive spectroscopy were used to perceive their structural and morphological characteristics. Selective area electron diffraction patterns confirm the plane obtained in XRD analysis. The average particle sizes for NPs and NCs were 50–60 nm, 80–120 nm, and 95–130 nm, respectively. The BCs with the mass of HA = 9.6 g and NC = 0.4 g exhibited minimum extension against applied load. It also showed better antibacterial activity against B. subtilis, S. aureus, and E. coli. Thus, BCs are suitable candidates for developing artificial bones and biomedical implants .
- 22 February 2022
- Published by Taylor & Francis in Materials Technology
- Vol. 37 (13) , 2503-2516
Antibacterial, Structural, and Mechanical Properties of MgO/ZnO Nanocomposites and its HA-Based Bio-Ceramics; Synthesized via Physio-Chemical Route for Biomedical Applications
The present work reports a novel method for fabricating nanocomposites (NCs) using Magnesium Oxide (MgO) and Zinc Oxide (ZnO) nanoparticles (NPs) via modified sol-gel route. Furthermore, hydroxyapatite was composited with MgO/ZnO NCs to form (HA)-based bio-ceramics (BCs) with enhanced antibacterial and mechanical properties. X-ray diffraction, Fourier transform infrared spectroscopy, field emission scanning electron and transmission electron microscopy, and energy-dispersive spectroscopy were used to perceive their structural and morphological characteristics. Selective area electron diffraction patterns confirm the plane obtained in XRD analysis. The average particle sizes for NPs and NCs were 50–60 nm, 80–120 nm, and 95–130 nm, respectively. The BCs with the mass of HA = 9.6 g and NC = 0.4 g exhibited minimum extension against applied load. It also showed better antibacterial activity against B. subtilis, S. aureus, and E. coli. Thus, BCs are suitable candidates for developing artificial bones and biomedical implants .
- 1 January 2022
- Published by Springer Nature
- p. 191-198
IoT Based Low-Cost Pulse Oximeter for Remote Health Monitoring
- 1 January 2022
- Published by Springer Nature
- p. 191-198
IoT Based Low-Cost Pulse Oximeter for Remote Health Monitoring
- 1 January 2022
- Published by Springer Nature
- p. 123-132
Light Weighted Model Based on Convolutional Neural Network for Detection of COVID-19 Using Chest X-Ray Images
- 1 January 2022
- Published by Springer Nature
- p. 123-132
Light Weighted Model Based on Convolutional Neural Network for Detection of COVID-19 Using Chest X-Ray Images
- 1 April 2021
- Published by Elsevier in Inorganic Chemistry Communications
- Vol. 126, 108479
Dual approach transformation of human finger and toe nail pruning into MgO/CaO nanoalloy
- 1 April 2021
- Published by Elsevier in Inorganic Chemistry Communications
- Vol. 126, 108479
Dual approach transformation of human finger and toe nail pruning into MgO/CaO nanoalloy
- 1 July 2020
- Published by Springer Nature in Journal of Applied Spectroscopy
- Vol. 87 (3) , 545-552
Wavelet-Based Noise Removal from Raman Signal to Study PLD Coated Forsterite-Hydroxyapatite Thin Film on Stainless Steel 316l Substrate
- 1 July 2020
- Published by Springer Nature in Journal of Applied Spectroscopy
- Vol. 87 (3) , 545-552
Wavelet-Based Noise Removal from Raman Signal to Study PLD Coated Forsterite-Hydroxyapatite Thin Film on Stainless Steel 316l Substrate