Chiara Garavelli
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Chiara Garavelli has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Marco Palanca
Department of Industrial Engineering, Alma Mater Studiorum - University of Bologna, Bologna, Italy
3 shared publications - Marco Viceconti
Department of Industrial Engineering, Alma Mater Studiorum - University of Bologna, Bologna, Italy
3 shared publications - Alessandra Aldieri
Department of Mechanical and Aerospace Engineering, Politecnico di Torino, Turin, Italy; PolitoBIOMed Lab, Politecnico di Torino, Turin, Italy
2 shared publications Alessandra Aldieri
Affiliations Department of Industrial Engineering, Alma Mater Studiorum—University of Bologna, Bologna, Italy, Medical Technology Lab, IRCCS Istituto Ortopedico Rizzoli, Bologna, Italy
1 shared publicationCristina Curreli
Affiliations Department of Industrial Engineering, Alma Mater Studiorum—University of Bologna, Bologna, Italy, Medical Technology Lab, IRCCS Istituto Ortopedico Rizzoli, Bologna, Italy
1 shared publication- Enrico Dall’aRa
University of Sheffield
1 shared publication
Latest Publications
- Open Access
- 10 August 2025
- Published by Wiley in International Journal for Numerical Methods in Biomedical Engineering
- Vol. 41 (8) , e70085
Can Multi‐Vertebral CT‐Based Finite Element Models Accurately Predict Strains? An In Vitro Validation Study
Many proposed FE models to predict the vertebral risk of fracture consider single vertebrae only, neglecting the role of the intervertebral discs in load transmission and distribution across vertebrae. Inclusion of the intervertebral discs in multi‐vertebrae models would allow more physiological boundary conditions. However, while CT allows material properties to be assigned to the vertebrae, no information about the discs is provided. Hence, the aim of this study was to build multi‐level FE models uniquely based on CT data and validate them by comparing the predicted displacements and strains against the experimental measurements. One spine segment (T10‐L1) was harvested from a human spine and tested in flexion‐compression in the elastic regime. During the test, displacements and strains on the anterior surface were measured with digital image correlation. The FE model was built starting from the CT scan of that same spine segment. HU‐based isotropic linear elastic properties were assigned to the vertebral bone. Five different combinations of hyperelastic material properties from the literature were assigned to the discs, modeling the nucleus pulposus and the anulus fibrosus separately. The boundary conditions replicated the flexion‐compression test performed experimentally. Predicted displacements and strains on the vertebrae surfaces were compared against the measured displacements and strains. The model excellently predicted the displacement field ( R 2 = 0.92/0.99). On the other hand, different constitutive laws for the discs resulted in different principal strain distributions, which substantially differed from the experimental one, showing average relative errors higher than 34%. In conclusion, a different modeling approach should be adopted for the discs in CT‐based multi‐level FE models to achieve acceptable accuracy.
- 10 August 2025
- Published by Wiley in International Journal for Numerical Methods in Biomedical Engineering
- Vol. 41 (8) , e70085
Open AccessCan Multi‐Vertebral CT‐Based Finite Element Models Accurately Predict Strains? An In Vitro Validation Study
Many proposed FE models to predict the vertebral risk of fracture consider single vertebrae only, neglecting the role of the intervertebral discs in load transmission and distribution across vertebrae. Inclusion of the intervertebral discs in multi‐vertebrae models would allow more physiological boundary conditions. However, while CT allows material properties to be assigned to the vertebrae, no information about the discs is provided. Hence, the aim of this study was to build multi‐level FE models uniquely based on CT data and validate them by comparing the predicted displacements and strains against the experimental measurements. One spine segment (T10‐L1) was harvested from a human spine and tested in flexion‐compression in the elastic regime. During the test, displacements and strains on the anterior surface were measured with digital image correlation. The FE model was built starting from the CT scan of that same spine segment. HU‐based isotropic linear elastic properties were assigned to the vertebral bone. Five different combinations of hyperelastic material properties from the literature were assigned to the discs, modeling the nucleus pulposus and the anulus fibrosus separately. The boundary conditions replicated the flexion‐compression test performed experimentally. Predicted displacements and strains on the vertebrae surfaces were compared against the measured displacements and strains. The model excellently predicted the displacement field ( R 2 = 0.92/0.99). On the other hand, different constitutive laws for the discs resulted in different principal strain distributions, which substantially differed from the experimental one, showing average relative errors higher than 34%. In conclusion, a different modeling approach should be adopted for the discs in CT‐based multi‐level FE models to achieve acceptable accuracy.
- Open Access
- 19 April 2025
- Published by Springer Nature in Biomechanics and Modeling in Mechanobiology
- Vol. 24 (3) , 1017-1030
Comparing the predictions of CT-based subject-specific finite element models of human metastatic vertebrae with digital volume correlation measurements
Several conditions can increase the incidence of vertebral fragility fractures, including metastatic bone disease. Computational tools could help clinicians estimate the risk of vertebral fracture in these patients; however, comparison with in vitro data is mandatory before using them in clinical practice. Nine spine segments were tested under compression and imaged with micro-computed tomography (µCT). The displacement field was calculated for each vertebra using a global digital volume correlation (DVC) approach. Subject-specific homogenised finite element models of each vertebra were built from µCT images, applying experimentally matched boundary conditions at the endplates. Numerical and experimental displacements, reaction forces, and locations showing higher strain concentrations were eventually compared. Additionally, given that µCT cannot be performed in clinical settings, the outcomes of a µCT-based model were also compared to those of a model built from clinical CT scans of the same specimen. Good agreement between DVC and µCT-based FE displacements was found, both for healthy (R 2 = 0.69 ÷ 0.83, RMSE = 3 ÷ 22%, max error < 45 μm) and metastatic (R 2 = 0.64 ÷ 0.93, RMSE = 5 ÷ 18%, max error < 54 μm) vertebrae. Strong correlations were found between µCT-based and clinical CT-based FE model outcomes (R 2 = 0.99, RMSE < 1.3%, max difference = 6 μm). Furthermore, the models qualitatively identified the most deformed regions identified with the experiments. In conclusion, the combination of experimental full-field technique and in-silico modelling enabled the development of a promising pipeline to validate bone strength predictors in the elastic range. Further improvements are needed to analyse vertebral post-yield behaviour better.
- 19 April 2025
- Published by Springer Nature in Biomechanics and Modeling in Mechanobiology
- Vol. 24 (3) , 1017-1030
Open AccessComparing the predictions of CT-based subject-specific finite element models of human metastatic vertebrae with digital volume correlation measurements
Several conditions can increase the incidence of vertebral fragility fractures, including metastatic bone disease. Computational tools could help clinicians estimate the risk of vertebral fracture in these patients; however, comparison with in vitro data is mandatory before using them in clinical practice. Nine spine segments were tested under compression and imaged with micro-computed tomography (µCT). The displacement field was calculated for each vertebra using a global digital volume correlation (DVC) approach. Subject-specific homogenised finite element models of each vertebra were built from µCT images, applying experimentally matched boundary conditions at the endplates. Numerical and experimental displacements, reaction forces, and locations showing higher strain concentrations were eventually compared. Additionally, given that µCT cannot be performed in clinical settings, the outcomes of a µCT-based model were also compared to those of a model built from clinical CT scans of the same specimen. Good agreement between DVC and µCT-based FE displacements was found, both for healthy (R 2 = 0.69 ÷ 0.83, RMSE = 3 ÷ 22%, max error < 45 μm) and metastatic (R 2 = 0.64 ÷ 0.93, RMSE = 5 ÷ 18%, max error < 54 μm) vertebrae. Strong correlations were found between µCT-based and clinical CT-based FE model outcomes (R 2 = 0.99, RMSE < 1.3%, max difference = 6 μm). Furthermore, the models qualitatively identified the most deformed regions identified with the experiments. In conclusion, the combination of experimental full-field technique and in-silico modelling enabled the development of a promising pipeline to validate bone strength predictors in the elastic range. Further improvements are needed to analyse vertebral post-yield behaviour better.
- Open Access
- 9 September 2022
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 17 (9) , e0272529
Experimental validation of a subject-specific finite element model of lumbar spine segment using digital image correlation
Pathologies such as cancer metastasis and osteoporosis strongly affect the mechanical properties of the vertebral bone and increase the risk of fragility fractures. The prediction of the fracture risk with a patient-specific model, directly generated from the diagnostic images of the patient, could help the clinician in the choice of the correct therapy to follow. But before such models can be used to support any clinical decision, their credibility must be demonstrated through verification, validation, and uncertainty quantification. In this study we describe a procedure for the generation of such patient-specific finite element models and present a first validation of the kinematics of the spine segment. Quantitative computed tomography images of a cadaveric lumbar spine segment presenting vertebral metastatic lesions were used to generate the model. The applied boundary conditions replicated a specific experimental test where the spine segment was loaded in compression-flexion. Model predictions in terms of vertebral surface displacements were compared against the full-field experimental displacements measured with Digital Image Correlation. A good agreement was obtained from the local comparison between experimental data and simulation results (R2 > 0.9 and RMSE% <8%). In conclusion, this work demonstrates the possibility to apply the developed modelling pipeline to predict the displacement field of human spine segment under physiological loading conditions, which is a first fundamental step in the credibility assessment of these clinical decision-support technology.
- 9 September 2022
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 17 (9) , e0272529
Open AccessExperimental validation of a subject-specific finite element model of lumbar spine segment using digital image correlation
Pathologies such as cancer metastasis and osteoporosis strongly affect the mechanical properties of the vertebral bone and increase the risk of fragility fractures. The prediction of the fracture risk with a patient-specific model, directly generated from the diagnostic images of the patient, could help the clinician in the choice of the correct therapy to follow. But before such models can be used to support any clinical decision, their credibility must be demonstrated through verification, validation, and uncertainty quantification. In this study we describe a procedure for the generation of such patient-specific finite element models and present a first validation of the kinematics of the spine segment. Quantitative computed tomography images of a cadaveric lumbar spine segment presenting vertebral metastatic lesions were used to generate the model. The applied boundary conditions replicated a specific experimental test where the spine segment was loaded in compression-flexion. Model predictions in terms of vertebral surface displacements were compared against the full-field experimental displacements measured with Digital Image Correlation. A good agreement was obtained from the local comparison between experimental data and simulation results (R2 > 0.9 and RMSE% <8%). In conclusion, this work demonstrates the possibility to apply the developed modelling pipeline to predict the displacement field of human spine segment under physiological loading conditions, which is a first fundamental step in the credibility assessment of these clinical decision-support technology.