Mariana De Oliveira Lobo
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Mariana De Oliveira Lobo has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Anderson Freitas
HOME, Brasília, Brazil
2 shared publications - Armando José China Bezerra
UCB, Brasil
1 shared publication - Felipe M. Braga
Orthopedics and Traumatology, Hospital Regional of Gama, Brasília, BRA
1 shared publication - Fernanda Caroline Moura Garcez
UCB, Brasil
1 shared publication - Flávio Eduardo Ramos Azevedo
Hospital Regional do Gama, St. Central Área Especial 01, 72405901, Brasília, DF, Brazil
1 shared publication - Leonardo Rigobello Battaglion
Universidade de São Paulo, Brazil
1 shared publication
Latest Publications
- Open Access
- 12 September 2022
- Published by MDPI AG in Bioengineering
- Vol. 9 (9) , 464
Evaluation of a Locking Autocompression Screw Model in Pauwels Type-3 Femoral Neck Fracture: In Vitro Analysis
Femoral neck fractures in young adults are uncommon, resulting from high-energy trauma. Despite their infrequency in this population, there is higher rate of complications, especially in the more vertical fracture line, classified by Pauwels as a type-3 femoral neck fracture. The implant type is of paramount importance for maintaining anatomical reduction, since it must resist the deforming forces that act on the fracture. We comparatively evaluated two constructions of the novel locking autocompression implant (X-PIN and X-PIN+P) using the finite element method and previously established methods for treating Pauwels type-3 femoral neck fractures. Six fixation models were developed for the study: a dynamic hip screw (DHS), a DHS with an anti-rotation screw (DHS+P), the inverted triangle multiple cannulated screws construction (ASNIS), the multiple cannulated screws in an L-configuration (L), and the two models of the novel locking autocompression screw (X-PIN and X-PIN+P). Under the same conditions with a load of 2100 N, the following parameters were evaluated using SIMLAB® software: the main maximum (Max P), main minimum (Min P), localized maximum P1 (Max P1), localized maximum P2 (Max P2), total displacement, localized displacement, rotation displacement, and von Mises stress. Compared to the DHS+P and ASNIS models, the X-PIN+P model presented, respectively, increases of 51.6% and 64.7% for Max P, 85% and 247% for Min P, and 18.9% and 166.7% for von Mises stress. Max P1 did not differ between the models, but Max P2 was 55% and 50% lower for X-PIN+P than ASNIS and L, respectively. All displacement values were lower for X-PIN+P than the other models. In this FEM testing, the X-PIN+P was superior to the other models, which was due to improvement in all parameters of stress distribution, displacement, and von Mises stress compared to models using a lateral plate (DHS and DHS+P) or not (ASNIS and L).
- 12 September 2022
- Published by MDPI AG in Bioengineering
- Vol. 9 (9) , 464
Open AccessEvaluation of a Locking Autocompression Screw Model in Pauwels Type-3 Femoral Neck Fracture: In Vitro Analysis
Femoral neck fractures in young adults are uncommon, resulting from high-energy trauma. Despite their infrequency in this population, there is higher rate of complications, especially in the more vertical fracture line, classified by Pauwels as a type-3 femoral neck fracture. The implant type is of paramount importance for maintaining anatomical reduction, since it must resist the deforming forces that act on the fracture. We comparatively evaluated two constructions of the novel locking autocompression implant (X-PIN and X-PIN+P) using the finite element method and previously established methods for treating Pauwels type-3 femoral neck fractures. Six fixation models were developed for the study: a dynamic hip screw (DHS), a DHS with an anti-rotation screw (DHS+P), the inverted triangle multiple cannulated screws construction (ASNIS), the multiple cannulated screws in an L-configuration (L), and the two models of the novel locking autocompression screw (X-PIN and X-PIN+P). Under the same conditions with a load of 2100 N, the following parameters were evaluated using SIMLAB® software: the main maximum (Max P), main minimum (Min P), localized maximum P1 (Max P1), localized maximum P2 (Max P2), total displacement, localized displacement, rotation displacement, and von Mises stress. Compared to the DHS+P and ASNIS models, the X-PIN+P model presented, respectively, increases of 51.6% and 64.7% for Max P, 85% and 247% for Min P, and 18.9% and 166.7% for von Mises stress. Max P1 did not differ between the models, but Max P2 was 55% and 50% lower for X-PIN+P than ASNIS and L, respectively. All displacement values were lower for X-PIN+P than the other models. In this FEM testing, the X-PIN+P was superior to the other models, which was due to improvement in all parameters of stress distribution, displacement, and von Mises stress compared to models using a lateral plate (DHS and DHS+P) or not (ASNIS and L).
- Open Access
- 22 June 2022
- Published by Springer Nature in Cureus
- Vol. 14 (6) , e26202
Technical Report: Percutaneous Reductions on Gartland Type III Supracondylar Fractures
Various surgical treatments for supracondylar fracture in children remain the motive of research and study. A common factor in each technique is anatomic reduction, which is critical for the excellent recovery of the fracture. Anatomic reduction is preferably realized through closed and percutaneous approaches. This study aimed to present a closed percutaneous technique to treat Gartland III supracondylar fractures to aggregate a facilitating factor in the surgical approach to this condition. Our technique was applied to surgical patients in orthopedic and traumatology emergency care and illustrated by a synthetic elbow model, including soft tissue and intraoperative images.
- 22 June 2022
- Published by Springer Nature in Cureus
- Vol. 14 (6) , e26202
Open AccessTechnical Report: Percutaneous Reductions on Gartland Type III Supracondylar Fractures
Various surgical treatments for supracondylar fracture in children remain the motive of research and study. A common factor in each technique is anatomic reduction, which is critical for the excellent recovery of the fracture. Anatomic reduction is preferably realized through closed and percutaneous approaches. This study aimed to present a closed percutaneous technique to treat Gartland III supracondylar fractures to aggregate a facilitating factor in the surgical approach to this condition. Our technique was applied to surgical patients in orthopedic and traumatology emergency care and illustrated by a synthetic elbow model, including soft tissue and intraoperative images.
- Open Access
- 1 August 2017
- Published by FapUNIFESP (SciELO) in Revista Bioética
- Vol. 25 (2) , 382-391
Relação médico-paciente idoso no cinema: visões de atendimento
Resumo Este artigo objetiva descrever diferentes visões de atendimento da relação médico-paciente idoso abordada em filmes de ficção. Pesquisou-se filmografia nacional e internacional, buscando filmes de longa-metragem que exibissem cenas em que a relação médico-paciente idoso fosse retratada de diferentes formas. Foi possível identificar nos dez filmes analisados expectativas referentes ao atendimento do paciente idoso, tanto na visão do paciente quanto na de seus familiares, evidenciando sentimentos e valores socioculturais presentes na inter-relação estabelecida durante o exercício profissional da medicina. Concluiu-se que a linguagem cinematográfica é útil para a formação do médico, que deve se preocupar com o sentido humano de seu trabalho, bem como para interpretar elementos que envolvem a complexa relação médico-paciente, particularmente com o idoso.
- 1 August 2017
- Published by FapUNIFESP (SciELO) in Revista Bioética
- Vol. 25 (2) , 382-391
Open AccessRelação médico-paciente idoso no cinema: visões de atendimento
Resumo Este artigo objetiva descrever diferentes visões de atendimento da relação médico-paciente idoso abordada em filmes de ficção. Pesquisou-se filmografia nacional e internacional, buscando filmes de longa-metragem que exibissem cenas em que a relação médico-paciente idoso fosse retratada de diferentes formas. Foi possível identificar nos dez filmes analisados expectativas referentes ao atendimento do paciente idoso, tanto na visão do paciente quanto na de seus familiares, evidenciando sentimentos e valores socioculturais presentes na inter-relação estabelecida durante o exercício profissional da medicina. Concluiu-se que a linguagem cinematográfica é útil para a formação do médico, que deve se preocupar com o sentido humano de seu trabalho, bem como para interpretar elementos que envolvem a complexa relação médico-paciente, particularmente com o idoso.