DTDi Tian

Di Tian

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Di Tian has a total of 115 co-authors. Here are the top co-authors by number of shared publications:

  • Xuefei Mao

    Chinese Acad Agr Sci, Inst Qual Stand & Testing Technol Agroprod, Beijing 100081, Peoples R China

    6 shared publications
  • Guang Yang

    College of Instrumentation Electrical Engineering, Jilin University, Changchun, Jilin, 130061, P. R. China

    5 shared publications
  • Guangmeng Guo

    College of Instrumentation & Electrical Engineering, Jilin University, Changchun, China

    5 shared publications
  • Hongxia Wang

    College of Instrumentation & Electrical Engineering, Jilin University, Changchun, Jilin, China

    5 shared publications
  • Ke Liu

    Wuhan National Laboratory for Optoelectronics (WNLO), Huazhong University of Science and Technology 2 , Wuhan, Hubei 430074, People’s Republic of China

    5 shared publications
  • Hongxia Wang

    College of Instrumentation & Electrical Engineering, Jilin University, Changchun 130023, China

    4 shared publications

Latest Publications

  • Segmented-Field-Gradient-Focusing Ion Guide for Simultaneously Improved Ion Transfer across a Wide Mass Range and Enhanced Sensitivity

    by Jiafeng Song, Di Zhang, Siyi Li, Bowen Zheng, Xinhua Dai, Siyuan Tan, Manman Zhu, Zejian Huang, Jie Xie, Di Tian, et al.

    The sensitivity of the atmospheric pressure ionization mass spectrometer (API-MS) has been improved owing to the advancement in the atmospheric pressure interface. However, ion scattering losses in the first vacuum chamber undermine this improvement. In this work, a novel multipole ion guide, called a segmented-field-gradient-focusing ion guide (SFGF-IG), was developed to address these losses, especially caused by the asymmetric-shaped supersonic jet generated by a slot-shaped inlet. The SFGF-IG combined a dodecapole (65 mm in length) and a quadrupole (125 mm in length), with each segment having its tilt angle optimized. By analyzing three different ion trajectory conditions, "Transmitted", "Reflected", and "Absorbed″, the key factors affecting the ion transfer in the SFGF-IG were investigated. Here, this analytical method for developing a high-performance ion guide was expanded to account for the influence of background gas. This revised method provides a framework for understanding the dominant mechanism that influences ion transfer within high-performance ion guides under complex background gas flow. Results showed that the SFGF-IG reduced ion scattering losses in the first vacuum chamber, which allowed the greater gas-throughput slot-shaped inlet to increase the API-MS sensitivity. Compared with the conventional ion funnel, the SFGF-IG demonstrated a significantly reduced low-mass discrimination effect and improved ion transfer across a wide mass range (100-2000 m/z), enabling simultaneous analysis of high-, medium-, and low-mass ions. Moreover, to verify the actual performance of the SFGF-IG, it was integrated into a home-built quadrupole-linear ion trap tandem MS (Q-LITMS) equipped with a slot-shaped inlet. The instrument detection limit (IDL) of the reserpine reached 0.15 fg (RSD 6.08%), two-fold lower than the conventional Q-LITMS configuration (0.3 fg and RSD 11.1%). This work provides a complete development approach for a high-performance ion guide to reduce ion scattering losses and further enhances the sensitivity of laboratory-scale MS.


  • Design and optimization of handheld alloy analysis instrument based on microjoule high pulse repetition frequency LIBS

    by Dongming Qu, Guang Yang, Wenwen Zhou, Huihui Sun, Jiaxuan Fang, Di Tian, Chunsheng Li, Qingkai Li

    We briefly describe the design of a handheld metal detection instrument based on microjoule high repetition frequency laser-induced breakdown spectroscopy. The instrument uses a Raspberry Pi as the control core and a laser with a frequency of 10 kHz and a single pulse energy of 100 µJ as the excitation source. In addition, a mini-putter is built into the instrument to move the laser, allowing the ablation of the sample surface line area without external auxiliary equipment. The excitation-generated plasma radiation is collected by a simple optical path and transmitted directly to the spectrometer. We also constructed and trained a Backpropagation Artificial Neural Network (BP-ANN) model based on 12 different grades of alloys and transplanted the feedback process of the BP-ANN to the Raspberry Pi, which realized the rapid classification of the 12 alloys with >95% classification accuracy on the handheld instrument.


  • Numerical Analysis and Quantification of Transfer Efficiency Coupled with Capillary and Quadrupole Ion Guide in an API-MS System

    by Jiafeng Song, Di Zhang, Xinhua Dai, Zejian Huang, Xiang Fang, Di Tian, You Jiang

    Ion trajectory simulation is a significant and useful tool for understanding ion transfer mechanisms within the first vacuum region of the atmospheric pressure ionization mass spectrometer (API-MS). However, the complex dynamic gas field and wide pressure range lead to inaccurate simulation and huge computational costs. In this work, a novel electrohydrodynamic simulation called the statistical diffusion-hard-sphere (SDHS) mixed collision model was developed for characterizing the ion trajectories. For the first time, the influence of the dynamic pressure on the ion trajectory is considered for simulation, which helps to avoid an intolerable computational cost. Comparing with the conventional Monte Carlo collision model, the SDHS method helps to improve the calculation accuracy of ion trajectories under the first vacuum region and reduce the computational cost for at least 12-folds. Simulation results showed that the maximum ion loss came from the gap of the electrodes. The distance of the capillary-quadrupole ion guide was also a non-negligible factor. The trend of quantitative experimental results matches the SDHS simulation results. The maximum ion transfer efficiencies of quantitative experiment and simulation were 55% and 52%, respectively. Moreover, three ions, caffeine, reserpine, and Ultramark 1621, were measured for evaluating the applicability of SDHS in real API-MS. The trend of experimental results showed good agreement with that of computation. And the results of caffeine further illustrated the reason that the small mass ion transfer efficiency decreased with increasing radio frequency voltage. SDHS method is expected to be useful in the design of ion guides for further improvement of the sensitivity of API-MS.


  • Synergistic catalysis of Ru0-Ru3+ in MOF supported ultrafine Ru nanoparticles catalyst promotes ethyl levulinate to γ-valerolactone

    by Zirui Dao, Ying Wang, Chunyan Yang, Siyi Pu, Wei Yan, Di Tian, Chungang Min, Jie Zhao, Changfu Zhuang


  • Discrimination of rocks by laser-induced breakdown spectroscopy combined with Random Forest (RF)

    by Xueying Jin, Guang Yang, Xuxu Sun, Dongming Qu, Shichao Li, Guanyu Chen, Chunsheng Li, Di Tian, Li Yao

    LIBS and RF were combined to realize the discrimination of rocks from different provenances.


  • Analysis and suppression of scattering interference for arsenic using dispersive atomic fluorescence spectrometry based on an ultraviolet digital micromirror device spectrometer

    by Hongxia Wang, Liuzhen Si, Chunsheng Li, Zhiheng Zhou, Di Tian

    A combination of UV-DMD-AFS and NFLR methods has been successfully used in the real-time suppression of scattering interference for arsenic, achieving long-term accuracy >99.20% (within 3 hours) in water quality samples.


  • High-sensitivity and field analysis of lead by portable optical emission spectrometry using a microplasma trap

    by Yaru Zhang, Jixin Liu, Xuefei Mao, Xing Na, Di Tian, Yongzhong Qian

    A novel field analysis method for analysing Pb in environmental water samples was developed using a portable optical emission spectrometric instrument coupled with solid acid hydride generation and an in situ dielectric barrier discharge trap.


  • Analysis of low‐abundance molecules in complex matrices by quadrupole‐linear ion trap mass spectrometry using a simultaneous fragmentation and accumulation strategy

    by Chang Li, You Jiang, Shiying Chu, Xinchi Yin, Siyuan Tan, Zejian Huang, Xinhua Dai, Xiaoyun Gong, Xiang Fang, Di Tian

    Rationale: Fast and sensitive analysis of low‐abundance molecules in complex matrices has always been a challenge in chemical and biological applications. Mass spectrometry (MS) has been widely used in the fields of chemical and biological analysis due to its unparalleled specificity and sensitivity. However, the MS signals consistently deteriorate in the presence of matrices. Demands for more sensitive and efficient methods to analyze those low‐abundance molecules in chemical and biological systems are in urgent need. Methods: Based on a home‐made quadrupole‐linear ion trap (Q‐LIT) mass spectrometer, a simultaneous fragmentation and accumulation strategy was developed to improve the sensitivity of the analysis for the low‐abundance molecules in complex matrices. Ions were filtered by the quadrupole into the LIT. The precursor ions were fragmented and the product ions were isolated and accumulated in the LIT simultaneously. The fragmentation, isolation and accumulation processes were conducted at the same time. The accumulation time could be controlled to accumulate sufficient product ions. Results: With this strategy, the signal intensity of targeted molecules could be increased by 2–8 times and by increasing the accumulation time, this could be further enhanced. Those interferences induced by isomers and matrices can be reduced by using our method. We further applied our method to the quantification and analysis of biological samples. Tryptic digested peptides of myoglobin (Mb) were successfully detected by our method. Conclusions: We have established a new method with great advantages in the detection of molecules in complex matrices. The application of this method promises better results in the bioanalytical area, especially for the analysis of substances in complex matrices in the future.


  • Open Access

    Towards Higher Sensitivity of Mass Spectrometry: A Perspective From the Mass Analyzers

    by Chang Li, Shiying Chu, Siyuan Tan, Xinchi Yin, You Jiang, Xinhua Dai, Xiaoyun Gong, Xiang Fang, Di Tian

    Mass spectrometry (MS) is one of the most widely used analytical techniques in many fields. Recent developments in chemical and biological researches have drawn much attention to the measurement of substances with low abundances in samples. Continuous efforts have been made consequently to further improve the sensitivity of MS. Modifications on the mass analyzers of mass spectrometers offer a direct, universal and practical way to obtain higher sensitivity. This review provides a comprehensive overview of the latest developments in mass analyzers for the improvement of mass spectrometers’ sensitivity, including quadrupole, ion trap, time-of-flight (TOF) and Fourier transform ion cyclotron (FT-ICR), as well as different combinations of these mass analyzers. The advantages and limitations of different mass analyzers and their combinations are compared and discussed. This review provides guidance to the selection of suitable mass spectrometers in chemical and biological analytical applications. It is also beneficial to the development of novel mass spectrometers.


  • Determination of Arsenic in Soil by Ultrasonic Assisted Slurry Sampling Hydride Generation (HG) in-Situ Dielectric Barrier Discharge Trap (DBD)-Optical Emission Spectrometry (OES)

    by Yaru Zhang, Xing Na, Yunbin Shao, Jixin Liu, Di Tian, Xuefei Mao

    An ultrasonic assisted slurry sampling procedure was coupled with hydride generation in-situ dielectric barrier discharge trap optical emission spectrometry (HG-in situ DBD trap-OES) to provide the simple and fast determination of arsenic in soil. The soil was treated HNO3 and HF in an ultrasonic bath for 25 min, subsequently diluted with 6% HCl (v/v) and 40 g L−1 thiourea, and placed into the ultrasonic bath again for 10 min to obtain a stable and homogeneous slurry that was introduced to HG-in-situ DBD trap-OES for As determination. Under the optimal conditions, the calibration coefficient exceeded 0.995 from 2 μg L−1 to 200 μg L−1. A method detection limit of 0.18 mg kg−1 was achieved for As in soil (250 times dilution) with a 3.4% relative standard deviation. The developed method was validated by the determination of As in three soil certified reference materials including GBW07430 (As, 18 ± 2 mg kg−1), GBW07447 (As, 10.7 ± 0.5 mg kg−1), and GBW07449 (As, 8.7 ± 0.6 mg kg−1), as well as two real soil samples. The results agreed well with the certified values and the measurements by inductively coupled plasma – mass spectrometry. With advantages of simple pretreatment procedures, small size/weight, low power consumption, and low manufacturing cost, the developed method has the potential to be widely applied in soil analysis.