Ben Indja
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Ben Indja has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Alireza Gholipour
Imaging and Phenotyping Laboratory, Charles Perkins Centre, University of Sydney, Sydney, NSW 2006, Australia
1 shared publication - Campbell D. Flynn
Epworth Med Fdn, Melbourne, Vic, Australia
1 shared publication Daniel L. Chan
Department of Surgery, St George Hospital, Sydney, Australia
1 shared publication- Jaewon Chang
St George Hosp, Dept Cardiothorac Surg, Gray St, Kogarah, NSW 2217, Australia
1 shared publication - Jiaxing Jason Qin
Imaging and Phenotyping Laboratory, Charles Perkins Centre, University of Sydney, Sydney, NSW 2006, Australia
1 shared publication Michael L. Talbot
Department of Surgery, St George Hospital, Sydney, Australia
1 shared publication
Latest Publications
- Open Access
- 21 September 2022
- Published by Springer Nature in BMC Surgery
- Vol. 22 (1) , 1-8
Hiatal reconstruction is safe and effective for control of reflux after laparoscopic sleeve gastrectomy
Background: Gastroesophageal reflux is a known complication following laparoscopic sleeve gastrectomy (LSG) as anatomical changes predispose to reduced lower esophageal sphincter pressure and development of hiatus hernia. The mainstay of surgical management has been Roux-en-Y gastric bypass (RYGB) which is not without risk. Hiatus hernia repair (HHR) with surgical reattachment of the oesophagus to the crura, recreating the phreno-esophageal ligament is a simple procedure specifically targeting a number of anatomical changes responsible for reflux in this population. Methods: We conducted a single centre retrospective analysis of adult patients with post-sleeve reflux refractory to medical treatment, managed with either HHR, RYGB or One-anastomosis Duodenal switch (OADS). PPI use and symptoms of reflux were assessed at early and mid-term time points via validated questionnaires. Results: 99 patients were included, of these the surgical procedure was HHR alone in 58, RYGB in 29 and OADS in 12. At early follow-up control of reflux symptoms was achieved in 72.4% after HHR, 82.1% after RYGB and 100% after OADS with no significant difference between groups (p = 0.09). At mid-term followup (median 10 months IQR 7–21) there was no significant difference in the presence of symptomatic reflux as determined by post-op Visick score nor a difference in PPI use. The GerdQ score was significantly lower after OADS as compared to HHR and RYGB (4.6 ± 2.3 vs 7.7 ± 2.2 vs 8.7 ± 3.5, p = 0.006). Conclusion: HHR with reconstruction of the phreno-esophageal ligament is a safe and effective procedure for patients with reflux after LSG, that avoids more complex operations such as RYGB and OADS and their associated long-term sequelae.
- 21 September 2022
- Published by Springer Nature in BMC Surgery
- Vol. 22 (1) , 1-8
Open AccessHiatal reconstruction is safe and effective for control of reflux after laparoscopic sleeve gastrectomy
Background: Gastroesophageal reflux is a known complication following laparoscopic sleeve gastrectomy (LSG) as anatomical changes predispose to reduced lower esophageal sphincter pressure and development of hiatus hernia. The mainstay of surgical management has been Roux-en-Y gastric bypass (RYGB) which is not without risk. Hiatus hernia repair (HHR) with surgical reattachment of the oesophagus to the crura, recreating the phreno-esophageal ligament is a simple procedure specifically targeting a number of anatomical changes responsible for reflux in this population. Methods: We conducted a single centre retrospective analysis of adult patients with post-sleeve reflux refractory to medical treatment, managed with either HHR, RYGB or One-anastomosis Duodenal switch (OADS). PPI use and symptoms of reflux were assessed at early and mid-term time points via validated questionnaires. Results: 99 patients were included, of these the surgical procedure was HHR alone in 58, RYGB in 29 and OADS in 12. At early follow-up control of reflux symptoms was achieved in 72.4% after HHR, 82.1% after RYGB and 100% after OADS with no significant difference between groups (p = 0.09). At mid-term followup (median 10 months IQR 7–21) there was no significant difference in the presence of symptomatic reflux as determined by post-op Visick score nor a difference in PPI use. The GerdQ score was significantly lower after OADS as compared to HHR and RYGB (4.6 ± 2.3 vs 7.7 ± 2.2 vs 8.7 ± 3.5, p = 0.006). Conclusion: HHR with reconstruction of the phreno-esophageal ligament is a safe and effective procedure for patients with reflux after LSG, that avoids more complex operations such as RYGB and OADS and their associated long-term sequelae.
- Open Access
- 12 September 2022
- Published by MDPI AG in Journal of Cardiovascular Development and Disease
- Vol. 9 (9) , 304
Evaluation of Left Ventricular Function Using Four-Dimensional Flow Cardiovascular Magnetic Resonance: A Systematic Review
There is increasing recognition of the value of four-dimensional flow cardiovascular magnetic resonance (4D-flow MRI) as a potential means to detect and measure abnormal flow behaviour that occurs during early left ventricular (LV) dysfunction. We performed a systematic review of current literature on the role of 4D-flow MRI-derived flow parameters in quantification of LV function with a focus on potential clinical applicability. A comprehensive literature search was performed in March 2022 on available databases. A total of 1186 articles were identified, and 30 articles were included in the final analysis. All the included studies were ranked as “highly clinically applicable”. There was considerable variability in the reporting of methodologies and analyses. All the studies were small-scale feasibility or pilot studies investigating a diverse range of flow parameters. The most common primary topics of investigation were energy-related flow parameters, flow components and vortex analysis which demonstrated potentials for quantifying early diastolic dysfunction, whilst other parameters including haemodynamic forces, residence time distribution and turbulent kinetic energy remain in need of further evaluation. Systematic quantitative comparison of study findings was not possible due to this heterogeneity, therefore limiting the collective power of the studies in evaluating clinical applicability of the flow parameters. To achieve broader clinical application of 4D-flow MRI, larger scale investigations are required, together with standardisation of methodologies and analytical approach.
- 12 September 2022
- Published by MDPI AG in Journal of Cardiovascular Development and Disease
- Vol. 9 (9) , 304
Open AccessEvaluation of Left Ventricular Function Using Four-Dimensional Flow Cardiovascular Magnetic Resonance: A Systematic Review
There is increasing recognition of the value of four-dimensional flow cardiovascular magnetic resonance (4D-flow MRI) as a potential means to detect and measure abnormal flow behaviour that occurs during early left ventricular (LV) dysfunction. We performed a systematic review of current literature on the role of 4D-flow MRI-derived flow parameters in quantification of LV function with a focus on potential clinical applicability. A comprehensive literature search was performed in March 2022 on available databases. A total of 1186 articles were identified, and 30 articles were included in the final analysis. All the included studies were ranked as “highly clinically applicable”. There was considerable variability in the reporting of methodologies and analyses. All the studies were small-scale feasibility or pilot studies investigating a diverse range of flow parameters. The most common primary topics of investigation were energy-related flow parameters, flow components and vortex analysis which demonstrated potentials for quantifying early diastolic dysfunction, whilst other parameters including haemodynamic forces, residence time distribution and turbulent kinetic energy remain in need of further evaluation. Systematic quantitative comparison of study findings was not possible due to this heterogeneity, therefore limiting the collective power of the studies in evaluating clinical applicability of the flow parameters. To achieve broader clinical application of 4D-flow MRI, larger scale investigations are required, together with standardisation of methodologies and analytical approach.