Cheen Sean Oon
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Cheen Sean Oon has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
Ji-Jinn Foo
Department of Mechanical Engineering, School of Engineering, Monash University Malaysia, Bandar Sunway, Selangor, Malaysia
3 shared publicationsManh-Vu Tran
Department of Mechanical Engineering, School of Engineering, Monash University Malaysia, Bandar Sunway, Selangor, Malaysia
3 shared publicationsSayshar Ram Nair
Department of Mechanical Engineering, School of Engineering, Monash University Malaysia, Bandar Sunway, Selangor, Malaysia
3 shared publicationsYanru Wang
Department of Mechanical Engineering, School of Engineering, Monash University Malaysia, Bandar Sunway, Selangor, Malaysia
3 shared publicationsAbreeza Manap
Institute of Sustainable Energy, Universiti Tenaga Nasional, Kajang, Malaysia
1 shared publicationE. V. Lau
Department of Mechanical Engineering, School of Engineering, Monash University Malaysia, Bandar Sunway, Selangor, Malaysia
1 shared publication
Latest Publications
- Open Access
- 27 February 2025
- Published by Springer Nature in Journal of Thermal Analysis and Calorimetry
- Vol. 150 (7) , 5663-5678
Heat transfer performance and fouling analysis of clove-treated graphene nanoplatelet nanofluid in a double-pipe heat exchanger
Nanofluids have found widespread application across various systems to enhance heat transfer, albeit with the simultaneous occurrence of fouling on heat exchange surfaces. In examining the impact of particulate fouling from nanoparticles on the heat transfer behavior of heat exchangers, this study conducted an experimental exploration utilizing green functionalized clove-treated graphene nanoplatelets (CGNP) nanofluid within a double-pipe heat exchanger (DPHE). Previous studies on nanofluids as heat transfer fluid have largely ignored the impact of particulate fouling on heat transfer performance over time. Various concentrations (0.025, 0.075, and 0.1 mass%) and flow rates (8 and 12 L min−1) were systematically examined over an extended operational time, with distilled water (DW) employed as a reference liquid for comparison. The experimental data were compared with simulation results at five different flow rates. The findings reveal that DW exhibited the highest overall heat transfer coefficient (OHTC) among all tested fluids with an OHTC of approximately 1660 W m2 K−1. Conversely, deposition occurred in the CGNP nanofluid at all concentrations over an extended operational period. Specifically, the 0.025 mass% concentration demonstrated the lowest fouling resistance in the developing stage. The fouling resistance reached constant for all the tested concentrations with estimated values of 0.15–0.16 m2K kW−1. Furthermore, a flow rate of 12 L min−1 was shown to reduce the fouling resistance by 50% when decreasing the flow rate to 8 L min−1. Overall, applying CGNP nanofluid in the DPHE over a prolonged testing duration was deemed ineffective. Exploring optimized techniques to mitigate the deposition of CGNP particles on the heat exchange pipe surfaces is necessary.
- 27 February 2025
- Published by Springer Nature in Journal of Thermal Analysis and Calorimetry
- Vol. 150 (7) , 5663-5678
Open AccessHeat transfer performance and fouling analysis of clove-treated graphene nanoplatelet nanofluid in a double-pipe heat exchanger
Nanofluids have found widespread application across various systems to enhance heat transfer, albeit with the simultaneous occurrence of fouling on heat exchange surfaces. In examining the impact of particulate fouling from nanoparticles on the heat transfer behavior of heat exchangers, this study conducted an experimental exploration utilizing green functionalized clove-treated graphene nanoplatelets (CGNP) nanofluid within a double-pipe heat exchanger (DPHE). Previous studies on nanofluids as heat transfer fluid have largely ignored the impact of particulate fouling on heat transfer performance over time. Various concentrations (0.025, 0.075, and 0.1 mass%) and flow rates (8 and 12 L min−1) were systematically examined over an extended operational time, with distilled water (DW) employed as a reference liquid for comparison. The experimental data were compared with simulation results at five different flow rates. The findings reveal that DW exhibited the highest overall heat transfer coefficient (OHTC) among all tested fluids with an OHTC of approximately 1660 W m2 K−1. Conversely, deposition occurred in the CGNP nanofluid at all concentrations over an extended operational period. Specifically, the 0.025 mass% concentration demonstrated the lowest fouling resistance in the developing stage. The fouling resistance reached constant for all the tested concentrations with estimated values of 0.15–0.16 m2K kW−1. Furthermore, a flow rate of 12 L min−1 was shown to reduce the fouling resistance by 50% when decreasing the flow rate to 8 L min−1. Overall, applying CGNP nanofluid in the DPHE over a prolonged testing duration was deemed ineffective. Exploring optimized techniques to mitigate the deposition of CGNP particles on the heat exchange pipe surfaces is necessary.
- Open Access
- 19 October 2024
- Published by Springer Nature in Journal of Thermal Analysis and Calorimetry
- Vol. 150 (1) , 377-394
Analysis of hydrodynamics and thermal–hydraulic performance of twisted angle fins within an annular conduit
This paper investigated the influence of various twisted angles of fin inserts integrated on the inner heated pipe wall of a double-pipe heat exchanger by analysing the thermal–hydraulic performance through numerical simulations. Results showed twisted angle fin (TAF) induced turbulent fluid flow phenomena, generating transverse and longitudinal vortices, along with swirling flow. This collaboration between the vortices and swirling flow effectively prevents heat trapping and enhances heat transfer from the inner pipe wall through the intensive fluid mixing. Despite longitudinal swirling vortices and turbulence significantly enhance local and global heat transfer performance, they led to increased pressure drop. However, TAF twisting reduces pressure drop by streamlining flow. The performance evaluation criterion (PEC) value is a dimensionless quantity that facilitates the comprehensive evaluation of optimal configurations by comparing the increment in Nusselt number and the increment in friction factor. PEC values greater than 1 indicate that the increase in Nusselt number exceeded the increase in friction factor. Among tested configurations, the twisted fin angles of 60° (TAF60) exhibited the highest improvement in Nusselt number and friction factor, also achieving the highest PEC of 1.59712 at Reynolds number of 1194.71. TAF40 and TAF50 were identified as optimal configurations for enhancing the thermal–hydraulic efficiency, with average PEC values of 1.26893 and 1.27030, respectively. Overall, the study indicated a consistent enhancement trend with increasing twisted angles and emphasizes the significant thermal performance improvement of TAF configurations compared to the smooth conduit. Furthermore, the results showed a converging tendency across all TAF configurations in the percentage improvement in Nusselt number and friction factor, as well as PEC compared to the baseline No fin configuration with increasing Reynolds number, suggesting that future improvements in thermal–hydraulic performance are more dependent on geometric angles than fluid flow velocity.
- 19 October 2024
- Published by Springer Nature in Journal of Thermal Analysis and Calorimetry
- Vol. 150 (1) , 377-394
Open AccessAnalysis of hydrodynamics and thermal–hydraulic performance of twisted angle fins within an annular conduit
This paper investigated the influence of various twisted angles of fin inserts integrated on the inner heated pipe wall of a double-pipe heat exchanger by analysing the thermal–hydraulic performance through numerical simulations. Results showed twisted angle fin (TAF) induced turbulent fluid flow phenomena, generating transverse and longitudinal vortices, along with swirling flow. This collaboration between the vortices and swirling flow effectively prevents heat trapping and enhances heat transfer from the inner pipe wall through the intensive fluid mixing. Despite longitudinal swirling vortices and turbulence significantly enhance local and global heat transfer performance, they led to increased pressure drop. However, TAF twisting reduces pressure drop by streamlining flow. The performance evaluation criterion (PEC) value is a dimensionless quantity that facilitates the comprehensive evaluation of optimal configurations by comparing the increment in Nusselt number and the increment in friction factor. PEC values greater than 1 indicate that the increase in Nusselt number exceeded the increase in friction factor. Among tested configurations, the twisted fin angles of 60° (TAF60) exhibited the highest improvement in Nusselt number and friction factor, also achieving the highest PEC of 1.59712 at Reynolds number of 1194.71. TAF40 and TAF50 were identified as optimal configurations for enhancing the thermal–hydraulic efficiency, with average PEC values of 1.26893 and 1.27030, respectively. Overall, the study indicated a consistent enhancement trend with increasing twisted angles and emphasizes the significant thermal performance improvement of TAF configurations compared to the smooth conduit. Furthermore, the results showed a converging tendency across all TAF configurations in the percentage improvement in Nusselt number and friction factor, as well as PEC compared to the baseline No fin configuration with increasing Reynolds number, suggesting that future improvements in thermal–hydraulic performance are more dependent on geometric angles than fluid flow velocity.
- Open Access
- 2 February 2024
- Published by Springer Nature in Journal of Thermal Analysis and Calorimetry
- Vol. 149 (19) , 11137-11154
Numerical investigation of thermo-hydraulic performance of perforated rectangular and sinusoidal vortex generators in a double-pipe heat exchanger
Vortex generators (VGs) are utilized in heating and cooling systems to enhance heat transfer efficiency for energy savings. This study investigates the thermo-hydraulic performance of using the rectangular vortex generators (RVG) and the sinusoidal vortex generator (SVG) with and without holes on the annular side of a double-pipe heat exchanger (DPHE) for turbulent regimes. The numerical analysis is conducted for different angles of attack (α) (15°, 45°, and 75°) and spacings between VGs (60, 100, and 300 mm). By comparing the heat transfer behavior for a given α, the RVG cases present a higher heat transfer when compared to the SVG cases, with an exception for the 15° case. The configuration with a low α and slight curvature augments flow velocities and vortex strength, thereby enhancing heat transfer efficiency. Moreover, the 15° SVGs-hole case demonstrates a higher Nusselt number compared to the no-hole case. Adding holes in the VG significantly reduces the pressure drop for the 45° and 75° cases, while it remains the same at the 15° case. Additionally, the 75° RVG case yields the highest Nusselt number among the studied cases, with an enhancement of 42.4% when compared to the smooth pipe at the Reynolds number of 5,711. The best performance evaluation criterion (PEC) is achieved by the 15° SVGs-hole case. When the effect of different spacings is examined, the spacing of 60 mm provides the highest PEC of 1.22. In short, the present study provides valuable insights for optimizing VG design and enhancing overall system performance in DPHEs.
- 2 February 2024
- Published by Springer Nature in Journal of Thermal Analysis and Calorimetry
- Vol. 149 (19) , 11137-11154
Open AccessNumerical investigation of thermo-hydraulic performance of perforated rectangular and sinusoidal vortex generators in a double-pipe heat exchanger
Vortex generators (VGs) are utilized in heating and cooling systems to enhance heat transfer efficiency for energy savings. This study investigates the thermo-hydraulic performance of using the rectangular vortex generators (RVG) and the sinusoidal vortex generator (SVG) with and without holes on the annular side of a double-pipe heat exchanger (DPHE) for turbulent regimes. The numerical analysis is conducted for different angles of attack (α) (15°, 45°, and 75°) and spacings between VGs (60, 100, and 300 mm). By comparing the heat transfer behavior for a given α, the RVG cases present a higher heat transfer when compared to the SVG cases, with an exception for the 15° case. The configuration with a low α and slight curvature augments flow velocities and vortex strength, thereby enhancing heat transfer efficiency. Moreover, the 15° SVGs-hole case demonstrates a higher Nusselt number compared to the no-hole case. Adding holes in the VG significantly reduces the pressure drop for the 45° and 75° cases, while it remains the same at the 15° case. Additionally, the 75° RVG case yields the highest Nusselt number among the studied cases, with an enhancement of 42.4% when compared to the smooth pipe at the Reynolds number of 5,711. The best performance evaluation criterion (PEC) is achieved by the 15° SVGs-hole case. When the effect of different spacings is examined, the spacing of 60 mm provides the highest PEC of 1.22. In short, the present study provides valuable insights for optimizing VG design and enhancing overall system performance in DPHEs.
- 2 January 2024
- Published by Springer Nature in Journal of Thermal Analysis and Calorimetry
- Vol. 149 (19) , 11119-11135
Thermohydraulic performance and field synergy analysis on streamlined conical annular fins with clove-functionalized GNP nanofluids
- 2 January 2024
- Published by Springer Nature in Journal of Thermal Analysis and Calorimetry
- Vol. 149 (19) , 11119-11135
Thermohydraulic performance and field synergy analysis on streamlined conical annular fins with clove-functionalized GNP nanofluids
- Open Access
- 24 August 2023
- Published by Springer Nature in Journal of Thermal Analysis and Calorimetry
- Vol. 148 (20) , 10973-10990
Numerical investigation of thermo-hydraulic performance in an annular heat exchanger with sinusoidal vortex generators
This study investigates thermal performance enhancement by utilizing vortex generators (VGs). VGs come in many designs, and this paper proposes optimizations for the sinusoidal vortex generator (SVG) when used in an annular conduit to improve heat transfer with minimal pressure drop. Two vital parameters of the SVG are analyzed, namely, blockage ratios (BRs) (0.1 and 0.2) and attack angles (α) (0–90°). The investigated fluid regime is turbulent, with the Reynolds number (Re) ranging from 5973 to 11,947. Three rows of SVGs are fitted on the surface of the inner pipe, where constant heat flux is applied, while the outer pipe wall is entirely insulated. The results indicate that the highest Nusselt number is enhanced by 20.4% over the smooth pipe when the case with BR = 0.2 and α = 90° is used at Re = 5973. However, the friction factor increases by 56.5% for the same case. Two types of transverse vortices are identified, where one type has its rotational axis normal to the inner pipe surface, and the other has its rotational axis parallel to the inner pipe surface. Those vortices with the axis perpendicular to the pipe surface merge with the fluid above the SVG to develop longitudinal vortices in different BRs and α. The case with BR = 0.2 and α = 15° yields the greatest average performance evaluation criterion (PEC) compared to other tested cases with a value of 1.054. This study finds that SVGs can contribute to a more efficient annular pipe-based heat transfer system.
- 24 August 2023
- Published by Springer Nature in Journal of Thermal Analysis and Calorimetry
- Vol. 148 (20) , 10973-10990
Open AccessNumerical investigation of thermo-hydraulic performance in an annular heat exchanger with sinusoidal vortex generators
This study investigates thermal performance enhancement by utilizing vortex generators (VGs). VGs come in many designs, and this paper proposes optimizations for the sinusoidal vortex generator (SVG) when used in an annular conduit to improve heat transfer with minimal pressure drop. Two vital parameters of the SVG are analyzed, namely, blockage ratios (BRs) (0.1 and 0.2) and attack angles (α) (0–90°). The investigated fluid regime is turbulent, with the Reynolds number (Re) ranging from 5973 to 11,947. Three rows of SVGs are fitted on the surface of the inner pipe, where constant heat flux is applied, while the outer pipe wall is entirely insulated. The results indicate that the highest Nusselt number is enhanced by 20.4% over the smooth pipe when the case with BR = 0.2 and α = 90° is used at Re = 5973. However, the friction factor increases by 56.5% for the same case. Two types of transverse vortices are identified, where one type has its rotational axis normal to the inner pipe surface, and the other has its rotational axis parallel to the inner pipe surface. Those vortices with the axis perpendicular to the pipe surface merge with the fluid above the SVG to develop longitudinal vortices in different BRs and α. The case with BR = 0.2 and α = 15° yields the greatest average performance evaluation criterion (PEC) compared to other tested cases with a value of 1.054. This study finds that SVGs can contribute to a more efficient annular pipe-based heat transfer system.
- Open Access
- 15 November 2022
- Published by Springer Nature in Journal of Thermal Analysis and Calorimetry
- Vol. 147 (24) , 14873-14890
Investigation of heat transfer performance within annular geometries with swirl-inducing fins using clove-treated graphene nanoplatelet colloidal suspension
The paper investigated the benefits of having fins that induce swirling flow within an annular passage. The importance of the vortical structures produced using different fin angles and flow velocities in heat transfer was studied. The combination of swirling fluid with recirculation on heat transfer within an annular domain was not fully understood, and this paper aims to address that gap. The 10°, 20°, 30° and 40° angled fins were investigated to understand the changes in heat transfer performance as fluid recirculation becomes more dominant as angles become steeper. The usage of CGNP colloidal suspension was investigated for its potential benefits in heat transfer in a domain with angled fins. The CGNP concentrations of 0.025, 0.075 and 0.1 mass % were used as part of this investigation. Higher concentrations of CGNP increased the overall heat transfer coefficient. A more compact fin spacing improved heat transfer performance at the expense of increased pressure drop. Fin angles of 20° and 30° yielded poor heat transfer performance in the transitional flow regime (2000 < Re < 3000) due to the smaller swirling longitudinal vortices being insufficient in promoting fluid mixing from the thermal boundary layer into the freestream.
- 15 November 2022
- Published by Springer Nature in Journal of Thermal Analysis and Calorimetry
- Vol. 147 (24) , 14873-14890
Open AccessInvestigation of heat transfer performance within annular geometries with swirl-inducing fins using clove-treated graphene nanoplatelet colloidal suspension
The paper investigated the benefits of having fins that induce swirling flow within an annular passage. The importance of the vortical structures produced using different fin angles and flow velocities in heat transfer was studied. The combination of swirling fluid with recirculation on heat transfer within an annular domain was not fully understood, and this paper aims to address that gap. The 10°, 20°, 30° and 40° angled fins were investigated to understand the changes in heat transfer performance as fluid recirculation becomes more dominant as angles become steeper. The usage of CGNP colloidal suspension was investigated for its potential benefits in heat transfer in a domain with angled fins. The CGNP concentrations of 0.025, 0.075 and 0.1 mass % were used as part of this investigation. Higher concentrations of CGNP increased the overall heat transfer coefficient. A more compact fin spacing improved heat transfer performance at the expense of increased pressure drop. Fin angles of 20° and 30° yielded poor heat transfer performance in the transitional flow regime (2000 < Re < 3000) due to the smaller swirling longitudinal vortices being insufficient in promoting fluid mixing from the thermal boundary layer into the freestream.
- Open Access
Reaction-Time-Dependent Opto-Electrical Properties of Graphene Oxide
The reaction-time-dependent synthesis of graphene oxide (GO) was carried out using a modified Hummer’s method. The drop-casting method was used to coat GO films on a glass substrate. Various techniques, including scanning electron microscopy, X-ray diffraction, UV–Vis spectroscopy (UV–Vis), Fourier transform infrared spectroscopy, and current–voltage characteristics, were performed to obtain the morphological, structural, optical, and electrical properties of GO. Morphological structural observations revealed that more oxygen functional groups were present as the reaction time increased from 24 to 96 h, which was confirmed by the optical properties of GO thin films. The resistivity of the as-deposited films increased from 9.74 × 106 to 26.85 × 106 Ω·cm as the reaction time increased. The optimized reaction time with a resistivity of 12.13 × 106 Ω·cm was 48 h, as demonstrated by morphological and optical data.
Open AccessReaction-Time-Dependent Opto-Electrical Properties of Graphene Oxide
The reaction-time-dependent synthesis of graphene oxide (GO) was carried out using a modified Hummer’s method. The drop-casting method was used to coat GO films on a glass substrate. Various techniques, including scanning electron microscopy, X-ray diffraction, UV–Vis spectroscopy (UV–Vis), Fourier transform infrared spectroscopy, and current–voltage characteristics, were performed to obtain the morphological, structural, optical, and electrical properties of GO. Morphological structural observations revealed that more oxygen functional groups were present as the reaction time increased from 24 to 96 h, which was confirmed by the optical properties of GO thin films. The resistivity of the as-deposited films increased from 9.74 × 106 to 26.85 × 106 Ω·cm as the reaction time increased. The optimized reaction time with a resistivity of 12.13 × 106 Ω·cm was 48 h, as demonstrated by morphological and optical data.