Michael Talamo
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Michael Talamo has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
- Julio Ojea Quintana
University of Pennsylvania, Philadelphia, Pennsylvania
2 shared publications Paul M. Sethi
Orthopaedic & Neurosurgery Specialists Foundation for Clinical Research and Education, ONSF, Greenwich, CT, USA
2 shared publications- Augustus D. Mazzocca
Enable Educational and Research Facility, Division of Sports Medicine, Department of Orthopaedic Surgery Mass General Brigham, Harvard Medical School Boston Massachusetts U.S.A.
1 shared publication - Benjamin C. Hawthorne
Department of Orthopaedic Surgery, University of Connecticut Health Center, Farmington, USA
1 shared publication - Caitlin G. Dorsey
Department of Orthopaedic Surgery, University of Connecticut School of Medicine, Farmington, CT, USA
1 shared publication Clifford Voigt
ONS Foundation for Clinical Research and Education Greenwich Connecticut U.S.A.
1 shared publication
Latest Publications
- Open Access
- 17 April 2023
- Published by Elsevier in JSES International
- Vol. 8 (2) , 274-277
Evaluating clinical outcomes of two biceps tenodesis techniques: Loop ‘N’ Tack and subpectoral biceps tenodesis
- 17 April 2023
- Published by Elsevier in JSES International
- Vol. 8 (2) , 274-277
Open AccessEvaluating clinical outcomes of two biceps tenodesis techniques: Loop ‘N’ Tack and subpectoral biceps tenodesis
- Open Access
- 4 April 2023
- Published by Wiley in Arthroscopy, Sports Medicine, and Rehabilitation
- Vol. 5 (3) , e607-e611
Arthroscopic Visualization Is a Reliable Method of Confirming Femoral Button Placement During Anterior Cruciate Ligament Reconstruction
Purpose: To compare arthroscopic visualization with intraoperative fluoroscopy for confirming proper femoral button placement during ACLR. Methods: Fifty consecutive patients undergoing soft‐tissue ACLR between March 2021 and February 2022 were evaluated for inclusion in this study. Both primary and revision ACLR cases using suspensory fixation were included. Surgeons rated their confidence of proper button placement from both an intra‐articular perspective (through the femoral tunnel) and an extra‐articular perspective (through the iliotibial band) by grading confidence with a Likert scale. Fluoroscopy was also performed for confirmation of proper button placement. Results: Fifty consecutive patients (35.1 ± 14.5 years of age) with soft‐tissue ACLR were included. Mean surgeon Likert confidence scores for accurate button placement were as follows: 4.1 of 5 ± 0.9 from an intra‐articular perspective, 4.6 of 5 ± 0.7 from an extra‐articular perspective, and 8.7 of 10 ± 1.4 based on the sum of intra‐ and extra‐articular perspectives. Fluoroscopic findings demonstrated that 48 of 50 cases had an appropriate flipped button on the lateral cortex of the femur. I total, 2 of 50 had soft‐tissue interposition. Cases in which surgeons had high confidence from both intra‐ and extra‐articular perspectives (≥9/10 sum score) were indicative of proper button placement 97% of the time. Conclusions: Arthroscopic visualization is a reliable method of confirming femoral button placement during ACLR and is sufficient to rule out intraoperative fluoroscopy during surgery. ACLR cases with high surgeon confidence from both intra‐ and extra‐articular perspectives (sum score of 9 or greater out of 10) resulted in proper femoral button placement in 97% of cases as confirmed by intraoperative fluoroscopy. Level of Evidence: Level II, prospective cohort study.
- 4 April 2023
- Published by Wiley in Arthroscopy, Sports Medicine, and Rehabilitation
- Vol. 5 (3) , e607-e611
Open AccessArthroscopic Visualization Is a Reliable Method of Confirming Femoral Button Placement During Anterior Cruciate Ligament Reconstruction
Purpose: To compare arthroscopic visualization with intraoperative fluoroscopy for confirming proper femoral button placement during ACLR. Methods: Fifty consecutive patients undergoing soft‐tissue ACLR between March 2021 and February 2022 were evaluated for inclusion in this study. Both primary and revision ACLR cases using suspensory fixation were included. Surgeons rated their confidence of proper button placement from both an intra‐articular perspective (through the femoral tunnel) and an extra‐articular perspective (through the iliotibial band) by grading confidence with a Likert scale. Fluoroscopy was also performed for confirmation of proper button placement. Results: Fifty consecutive patients (35.1 ± 14.5 years of age) with soft‐tissue ACLR were included. Mean surgeon Likert confidence scores for accurate button placement were as follows: 4.1 of 5 ± 0.9 from an intra‐articular perspective, 4.6 of 5 ± 0.7 from an extra‐articular perspective, and 8.7 of 10 ± 1.4 based on the sum of intra‐ and extra‐articular perspectives. Fluoroscopic findings demonstrated that 48 of 50 cases had an appropriate flipped button on the lateral cortex of the femur. I total, 2 of 50 had soft‐tissue interposition. Cases in which surgeons had high confidence from both intra‐ and extra‐articular perspectives (≥9/10 sum score) were indicative of proper button placement 97% of the time. Conclusions: Arthroscopic visualization is a reliable method of confirming femoral button placement during ACLR and is sufficient to rule out intraoperative fluoroscopy during surgery. ACLR cases with high surgeon confidence from both intra‐ and extra‐articular perspectives (sum score of 9 or greater out of 10) resulted in proper femoral button placement in 97% of cases as confirmed by intraoperative fluoroscopy. Level of Evidence: Level II, prospective cohort study.
- 13 September 2022
- Published by Elsevier in Journal of Shoulder and Elbow Surgery
- Vol. 32 (2) , 326-332
Biomechanical evaluation of subscapularis peel repairs augmented with the long head of the biceps tendon for anatomic total shoulder arthroplasty
- 13 September 2022
- Published by Elsevier in Journal of Shoulder and Elbow Surgery
- Vol. 32 (2) , 326-332
Biomechanical evaluation of subscapularis peel repairs augmented with the long head of the biceps tendon for anatomic total shoulder arthroplasty