Yaseen Ahmed Mohammed Alsumaidaee
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Yaseen Ahmed Mohammed Alsumaidaee has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Chai Phing Chen
Universiti Tenaga Nasional (UNITEN)
4 shared publications - Chong Tak Yaw
Institute of Sustainable Energy, Universiti Tenaga Nasional, Kajang, Malaysia
4 shared publications - Siaw Paw Koh
Institute of Sustainable Energy, Universiti Tenaga Nasional (The Energy University), Jalan IKRAM-UNITEN, Kajang 43000, Malaysia
4 shared publications - Sieh Kiong Tiong
Universiti Tenaga Nasional (UNITEN)
4 shared publications Abdulelah Hameed Yaseen
3 shared publications- Kharudin Ali
Faculty of Engineering Technology (Electrical Automation), University College TATI, 24000 Kemaman, Terengganu, Malaysia
3 shared publications
Latest Publications
- Open Access
- 31 August 2025
- Published by International Information and Engineering Technology Association in Mathematical Modelling of Engineering Problems
- Vol. 12 (8) , 2669-2680
Evaluate Fluid Transfer Resistance in a Hydraulic System
- 31 August 2025
- Published by International Information and Engineering Technology Association in Mathematical Modelling of Engineering Problems
- Vol. 12 (8) , 2669-2680
Open AccessEvaluate Fluid Transfer Resistance in a Hydraulic System
- Open Access
- 31 January 2025
- Published by International Information and Engineering Technology Association in International Journal of Safety and Security Engineering
- Vol. 15 (1) , 141-150
Optimizing Malware Detection and Classification in Real-Time Using Hybrid Deep Learning Approaches
- 31 January 2025
- Published by International Information and Engineering Technology Association in International Journal of Safety and Security Engineering
- Vol. 15 (1) , 141-150
Open AccessOptimizing Malware Detection and Classification in Real-Time Using Hybrid Deep Learning Approaches
- Open Access
- 28 October 2024
- Published by International Information and Engineering Technology Association in Journal Européen des Systèmes Automatisés
- Vol. 57 (5) , 1461-1470
Reliable Mechanical Fault Diagnosis in Medium Voltage Electrical Switchgear Using a 1D-Convolutional Neural Network
- 28 October 2024
- Published by International Information and Engineering Technology Association in Journal Européen des Systèmes Automatisés
- Vol. 57 (5) , 1461-1470
Open AccessReliable Mechanical Fault Diagnosis in Medium Voltage Electrical Switchgear Using a 1D-Convolutional Neural Network
- Open Access
- 1 October 2023
- Published by Institute of Advanced Engineering and Science in Indonesian Journal of Electrical Engineering and Computer Science
- Vol. 32 (1) , 413-422
Detecting surface discharge faults in switchgear by using hybrid model
Switchgear plays a crucial role in power systems, providing protection and control over electrical equipment. However, tracking (surface discharge) can lead to insulation degradation and switchgear failure, necessitating reliable and effective identification of tracking defects. In this paper, we propose a hybrid one-dimension convolutional neural network long short-term memory networks (1D-CNN-LSTM) model as a solution to this problem. Data from both time domain analysis (TDA) and frequency domain analysis (FDA) are utilized for model evaluation. The model achieved error-free accuracy of 100% in both TDA and FDA during the training, validation, and testing phases. The model's performance is further assessed using performance measures and the visualization of accuracy and loss curves. The results show that the hybrid 1D-CNN-LSTM model works well to accurately find and classify surface discharge tracking defects in switchgear. The model offers precise and dependable fault identification, which has the potential to significantly enhance switchgear functionality. By enabling proactive maintenance and timely intervention, the proposed model contributes to the overall reliability and performance of switchgear in power systems. The findings of this research provide valuable insights for the design and implementation of advanced fault detection systems in switchgear applications.
- 1 October 2023
- Published by Institute of Advanced Engineering and Science in Indonesian Journal of Electrical Engineering and Computer Science
- Vol. 32 (1) , 413-422
Open AccessDetecting surface discharge faults in switchgear by using hybrid model
Switchgear plays a crucial role in power systems, providing protection and control over electrical equipment. However, tracking (surface discharge) can lead to insulation degradation and switchgear failure, necessitating reliable and effective identification of tracking defects. In this paper, we propose a hybrid one-dimension convolutional neural network long short-term memory networks (1D-CNN-LSTM) model as a solution to this problem. Data from both time domain analysis (TDA) and frequency domain analysis (FDA) are utilized for model evaluation. The model achieved error-free accuracy of 100% in both TDA and FDA during the training, validation, and testing phases. The model's performance is further assessed using performance measures and the visualization of accuracy and loss curves. The results show that the hybrid 1D-CNN-LSTM model works well to accurately find and classify surface discharge tracking defects in switchgear. The model offers precise and dependable fault identification, which has the potential to significantly enhance switchgear functionality. By enabling proactive maintenance and timely intervention, the proposed model contributes to the overall reliability and performance of switchgear in power systems. The findings of this research provide valuable insights for the design and implementation of advanced fault detection systems in switchgear applications.
- Open Access
- 5 April 2023
- Published by MDPI AG in Applied Sciences
- Vol. 13 (7) , 4617
Detecting Arcing Faults in Switchgear by Using Deep Learning Techniques
Switchgear and control gear are susceptible to arc problems that arise from slowly developing defects such as partial discharge, arcing, and heating due to faulty connections. These issues can now be detected and monitored using modern technology. This study aims to explore the effectiveness of deep learning techniques, specifically 1D-CNN model, LSTM model, and 1D-CNN-LSTM model, in detecting arcing problems in switchgear. The hybrid model 1D-CNN-LSTM was the preferred model for fault detection in switchgear because of its superior performance in both time and frequency domains, allowing for analysis of the generated sound wave during an arcing event. To investigate the effectiveness of the algorithms, experiments were conducted to locate arcing faults in switchgear, and the time and frequency domain analyses of performance were conducted. The 1D-CNN-LSTM model proved to be the most effective model for differentiating between arcing and non-arcing situations in the training, validation, and testing stages. Time domain analysis (TDA) showed high success rates of 99%, 100%, and 98.4% for 1D-CNN; 99%, 100%, and 98.4% for LSTM; and 100%, 100%, and 100% for 1D-CNN-LSTM in distinguishing between arcing and non-arcing cases in the respective training, validation, and testing phases. Furthermore, frequency domain analysis (FDA) also demonstrated high accuracy rates of 100%, 100%, and 95.8% for 1D-CNN; 100%, 100%, and 95.8% for LSTM; and 100%, 100%, and 100% for 1D-CNN-LSTM in the respective training, validation, and testing phases. Therefore, it can be concluded that the developed algorithms, particularly the 1D-CNN-LSTM model in both time and frequency domains, effectively recognize arcing faults in switchgear, providing an efficient and effective method for monitoring and detecting faults in switchgear and control gear systems.
- 5 April 2023
- Published by MDPI AG in Applied Sciences
- Vol. 13 (7) , 4617
Open AccessDetecting Arcing Faults in Switchgear by Using Deep Learning Techniques
Switchgear and control gear are susceptible to arc problems that arise from slowly developing defects such as partial discharge, arcing, and heating due to faulty connections. These issues can now be detected and monitored using modern technology. This study aims to explore the effectiveness of deep learning techniques, specifically 1D-CNN model, LSTM model, and 1D-CNN-LSTM model, in detecting arcing problems in switchgear. The hybrid model 1D-CNN-LSTM was the preferred model for fault detection in switchgear because of its superior performance in both time and frequency domains, allowing for analysis of the generated sound wave during an arcing event. To investigate the effectiveness of the algorithms, experiments were conducted to locate arcing faults in switchgear, and the time and frequency domain analyses of performance were conducted. The 1D-CNN-LSTM model proved to be the most effective model for differentiating between arcing and non-arcing situations in the training, validation, and testing stages. Time domain analysis (TDA) showed high success rates of 99%, 100%, and 98.4% for 1D-CNN; 99%, 100%, and 98.4% for LSTM; and 100%, 100%, and 100% for 1D-CNN-LSTM in distinguishing between arcing and non-arcing cases in the respective training, validation, and testing phases. Furthermore, frequency domain analysis (FDA) also demonstrated high accuracy rates of 100%, 100%, and 95.8% for 1D-CNN; 100%, 100%, and 95.8% for LSTM; and 100%, 100%, and 100% for 1D-CNN-LSTM in the respective training, validation, and testing phases. Therefore, it can be concluded that the developed algorithms, particularly the 1D-CNN-LSTM model in both time and frequency domains, effectively recognize arcing faults in switchgear, providing an efficient and effective method for monitoring and detecting faults in switchgear and control gear systems.
- Open Access
Detection of Corona Faults in Switchgear by Using 1D-CNN, LSTM, and 1D-CNN-LSTM Methods
The damaging effects of corona faults have made them a major concern in metal-clad switchgear, requiring extreme caution during operation. Corona faults are also the primary cause of flashovers in medium-voltage metal-clad electrical equipment. The root cause of this issue is an electrical breakdown of the air due to electrical stress and poor air quality within the switchgear. Without proper preventative measures, a flashover can occur, resulting in serious harm to workers and equipment. As a result, detecting corona faults in switchgear and preventing electrical stress buildup in switches is critical. Recent years have seen the successful use of Deep Learning (DL) applications for corona and non-corona detection, owing to their autonomous feature learning capability. This paper systematically analyzes three deep learning techniques, namely 1D-CNN, LSTM, and 1D-CNN-LSTM hybrid models, to identify the most effective model for detecting corona faults. The hybrid 1D-CNN-LSTM model is deemed the best due to its high accuracy in both the time and frequency domains. This model analyzes the sound waves generated in switchgear to detect faults. The study examines model performance in both the time and frequency domains. In the time domain analysis (TDA), 1D-CNN achieved success rates of 98%, 98.4%, and 93.9%, while LSTM obtained success rates of 97.3%, 98.4%, and 92.4%. The most suitable model, the 1D-CNN-LSTM, achieved success rates of 99.3%, 98.4%, and 98.4% in differentiating corona and non-corona cases during training, validation, and testing. In the frequency domain analysis (FDA), 1D-CNN achieved success rates of 100%, 95.8%, and 95.8%, while LSTM obtained success rates of 100%, 100%, and 100%. The 1D-CNN-LSTM model achieved a 100%, 100%, and 100% success rate during training, validation, and testing. Hence, the developed algorithms achieved high performance in identifying corona faults in switchgear, particularly the 1D-CNN-LSTM model due to its accuracy in detecting corona faults in both the time and frequency domains.
Open AccessDetection of Corona Faults in Switchgear by Using 1D-CNN, LSTM, and 1D-CNN-LSTM Methods
The damaging effects of corona faults have made them a major concern in metal-clad switchgear, requiring extreme caution during operation. Corona faults are also the primary cause of flashovers in medium-voltage metal-clad electrical equipment. The root cause of this issue is an electrical breakdown of the air due to electrical stress and poor air quality within the switchgear. Without proper preventative measures, a flashover can occur, resulting in serious harm to workers and equipment. As a result, detecting corona faults in switchgear and preventing electrical stress buildup in switches is critical. Recent years have seen the successful use of Deep Learning (DL) applications for corona and non-corona detection, owing to their autonomous feature learning capability. This paper systematically analyzes three deep learning techniques, namely 1D-CNN, LSTM, and 1D-CNN-LSTM hybrid models, to identify the most effective model for detecting corona faults. The hybrid 1D-CNN-LSTM model is deemed the best due to its high accuracy in both the time and frequency domains. This model analyzes the sound waves generated in switchgear to detect faults. The study examines model performance in both the time and frequency domains. In the time domain analysis (TDA), 1D-CNN achieved success rates of 98%, 98.4%, and 93.9%, while LSTM obtained success rates of 97.3%, 98.4%, and 92.4%. The most suitable model, the 1D-CNN-LSTM, achieved success rates of 99.3%, 98.4%, and 98.4% in differentiating corona and non-corona cases during training, validation, and testing. In the frequency domain analysis (FDA), 1D-CNN achieved success rates of 100%, 95.8%, and 95.8%, while LSTM obtained success rates of 100%, 100%, and 100%. The 1D-CNN-LSTM model achieved a 100%, 100%, and 100% success rate during training, validation, and testing. Hence, the developed algorithms achieved high performance in identifying corona faults in switchgear, particularly the 1D-CNN-LSTM model due to its accuracy in detecting corona faults in both the time and frequency domains.
- Open Access
Review of Medium-Voltage Switchgear Fault Detection in a Condition-Based Monitoring System by Using Deep Learning
In power energy distribution networks, switchgear is considered critical equipment. This is because the act of monitoring the operation and condition of switchgear, as well as performing the required corrective maintenance on any potentially problematic equipment, is critical. A single event may harm thousands of customers over time and pose a significant risk to operational staff. Many considerations must be put in place before using outages to switch down the system since they may raise maintenance costs and disrupt the power supply to users. As a result, proper interpretation of switchgear status evaluations is critical for the early identification of possible faults. Existing ultrasound condition-based monitoring (CBM) diagnostic testing techniques require the tester to manually interpret test data. This study aims to review the status of the recent development of CBM techniques with faults in switchgear. The current trend in electrification will be toward the safety and sustainability of power grid assets, which involves an evaluation of the electrical systems’ and components’ health and grids for medium-voltage distribution. This work provides a current state-of-the-art evaluation of deep learning (DL)-based smart diagnostics that were used to identify partial discharges and localize them. DL techniques are discussed and categorized, with special attention given to those sophisticated in the last five years. The key features of each method, such as fundamental approach and accuracy, are outlined and compared in depth. The benefits and drawbacks of various DL algorithms are also examined. The technological constraints that hinder sophisticated PD diagnostics from being implemented in companies are also recognized. Lastly, various remedies are suggested, as well as future research prospects.
Open AccessReview of Medium-Voltage Switchgear Fault Detection in a Condition-Based Monitoring System by Using Deep Learning
In power energy distribution networks, switchgear is considered critical equipment. This is because the act of monitoring the operation and condition of switchgear, as well as performing the required corrective maintenance on any potentially problematic equipment, is critical. A single event may harm thousands of customers over time and pose a significant risk to operational staff. Many considerations must be put in place before using outages to switch down the system since they may raise maintenance costs and disrupt the power supply to users. As a result, proper interpretation of switchgear status evaluations is critical for the early identification of possible faults. Existing ultrasound condition-based monitoring (CBM) diagnostic testing techniques require the tester to manually interpret test data. This study aims to review the status of the recent development of CBM techniques with faults in switchgear. The current trend in electrification will be toward the safety and sustainability of power grid assets, which involves an evaluation of the electrical systems’ and components’ health and grids for medium-voltage distribution. This work provides a current state-of-the-art evaluation of deep learning (DL)-based smart diagnostics that were used to identify partial discharges and localize them. DL techniques are discussed and categorized, with special attention given to those sophisticated in the last five years. The key features of each method, such as fundamental approach and accuracy, are outlined and compared in depth. The benefits and drawbacks of various DL algorithms are also examined. The technological constraints that hinder sophisticated PD diagnostics from being implemented in companies are also recognized. Lastly, various remedies are suggested, as well as future research prospects.