Ryan Lubbe
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ryan Lubbe has a total of 35 co-authors. Here are the top co-authors by number of shared publications:
- Erin L. Hsu
Department of Orthopaedic Surgery, Feinberg School of Medicine, Northwestern University, Chicago, IL 60611, USA
3 shared publications - Kevin Y. Chang
Department of Medicine University of Minnesota School of Medicine Minneapolis MN
3 shared publications - Stuart R. Stock
Dept. of Cell and Developmental Biology, Feinberg School of Medicine, and Center for Regenerative Nanomedicine, Northwestern University, Chicago, IL, USA
3 shared publications - Adam J. Driscoll
Departments of Orthopaedic Surgery (C.Y., M.S.H., S.J., M.A.O., A.J.D., K.Y.C., J.Y., J.P., R.J.L., W.K.H., and E.L.H.) and Cell and Molecular Biology (S.R.S.), Northwestern University Feinberg School of Medicine, Chicago, Illinois
2 shared publications - Chawon Yun
Department of Pharmacy, College of Pharmacy, Research Institute for Drug Development, Pusan National University, Busan 46241, Republic of Korea
2 shared publications - Meraaj S. Haleem
Departments of Orthopaedic Surgery (C.Y., M.S.H., S.J., M.A.O., A.J.D., K.Y.C., J.Y., J.P., R.J.L., W.K.H., and E.L.H.) and Cell and Molecular Biology (S.R.S.), Northwestern University Feinberg School of Medicine, Chicago, Illinois
2 shared publications
Latest Publications
- 17 October 2023
- Published by Elsevier in Biomaterials
- Vol. 302, 122357
A supramolecular polymer-collagen microparticle slurry for bone regeneration with minimal growth factor
- 17 October 2023
- Published by Elsevier in Biomaterials
- Vol. 302, 122357
A supramolecular polymer-collagen microparticle slurry for bone regeneration with minimal growth factor
- 23 March 2021
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 103 (11) , 984-991
Effect of Postoperative Analgesic Exposure to the Cannabinoid Receptor Agonist WIN55 on Osteogenic Differentiation and Spinal Fusion in Rats
Background: After spinal surgery and other orthopaedic procedures, most patients receive opioids for pain, leading to potential complications such as pseudarthrosis and opioid abuse associated with long-term use. As an alternative, the endocannabinoid system has been shown to have antinociceptive activity, while contributing to bone homeostasis via the CB1 and CB2 cannabinoid receptors. This study evaluates the impact of the cannabinoid receptor agonist WIN55,212-2 (WIN55) on osteogenic differentiation in vitro as well as bone regeneration and spinal fusion in a preclinical rat model. Methods: Primary rat bone marrow stromal cells were cultured in standard or osteogenic media and exposed to vehicle alone or WIN55. Runx2 and Alkaline phosphatase (Alpl) were quantified via qPCR (quantitative real-time polymerase chain reaction), followed by assessment of ALP activity and matrix mineralization. For in vivo evaluation, 45 female Sprague Dawley rats (n = 15 per group) underwent L4-L5 posterolateral spinal fusion with bilateral placement of collagen scaffolds preloaded with low-dose rhBMP-2 (recombinant human bone morphogenetic protein-2; 0.5 μg/implant). Postoperatively, rats received the vehicle alone or 0.5 or 2.5 mg/kg WIN55 via daily intraperitoneal injections for 5 days. Bone regeneration and spinal fusion were assessed using radiography, manual palpation-based fusion scoring, microcomputed tomography imaging, and histology. Results: mRNA expression levels of Runx2 and Alp were similar among cells treated with vehicle alone and WIN55. Likewise, exposure to WIN55 did not inhibit ALP activity or bone matrix mineralization. In this animal model, no significant differences were found among groups with regard to mean fusion score, fusion rate, or new bone volume. Conclusions: WIN55 showed no adverse impact on osteogenic differentiation, bone regeneration, and spinal fusion. This supports that cannabinoid receptor agonists should be further investigated as a potential alternative approach for postoperative analgesia following spinal fusion and other orthopaedic procedures requiring bone-healing. Clinical Relevance: The identification of alternative treatments for postoperative pain following orthopaedic surgical procedures is crucial in combating the ongoing opioid abuse crisis. The endocannabinoid system may represent a viable alternative target for addressing orthopaedic postoperative pain.
- 23 March 2021
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 103 (11) , 984-991
Effect of Postoperative Analgesic Exposure to the Cannabinoid Receptor Agonist WIN55 on Osteogenic Differentiation and Spinal Fusion in Rats
Background: After spinal surgery and other orthopaedic procedures, most patients receive opioids for pain, leading to potential complications such as pseudarthrosis and opioid abuse associated with long-term use. As an alternative, the endocannabinoid system has been shown to have antinociceptive activity, while contributing to bone homeostasis via the CB1 and CB2 cannabinoid receptors. This study evaluates the impact of the cannabinoid receptor agonist WIN55,212-2 (WIN55) on osteogenic differentiation in vitro as well as bone regeneration and spinal fusion in a preclinical rat model. Methods: Primary rat bone marrow stromal cells were cultured in standard or osteogenic media and exposed to vehicle alone or WIN55. Runx2 and Alkaline phosphatase (Alpl) were quantified via qPCR (quantitative real-time polymerase chain reaction), followed by assessment of ALP activity and matrix mineralization. For in vivo evaluation, 45 female Sprague Dawley rats (n = 15 per group) underwent L4-L5 posterolateral spinal fusion with bilateral placement of collagen scaffolds preloaded with low-dose rhBMP-2 (recombinant human bone morphogenetic protein-2; 0.5 μg/implant). Postoperatively, rats received the vehicle alone or 0.5 or 2.5 mg/kg WIN55 via daily intraperitoneal injections for 5 days. Bone regeneration and spinal fusion were assessed using radiography, manual palpation-based fusion scoring, microcomputed tomography imaging, and histology. Results: mRNA expression levels of Runx2 and Alp were similar among cells treated with vehicle alone and WIN55. Likewise, exposure to WIN55 did not inhibit ALP activity or bone matrix mineralization. In this animal model, no significant differences were found among groups with regard to mean fusion score, fusion rate, or new bone volume. Conclusions: WIN55 showed no adverse impact on osteogenic differentiation, bone regeneration, and spinal fusion. This supports that cannabinoid receptor agonists should be further investigated as a potential alternative approach for postoperative analgesia following spinal fusion and other orthopaedic procedures requiring bone-healing. Clinical Relevance: The identification of alternative treatments for postoperative pain following orthopaedic surgical procedures is crucial in combating the ongoing opioid abuse crisis. The endocannabinoid system may represent a viable alternative target for addressing orthopaedic postoperative pain.
- Open Access
- 1 January 2021
- Published by SAGE Publications in Tissue Engineering Part A
- Vol. 27 (1-2) , 26-36
Influence of Geometry and Architecture on the In Vivo Success of 3D-Printed Scaffolds for Spinal Fusion
We previously developed a recombinant growth factor-free, 3D-printed material comprised of hydroxyapatite (HA) and demineralized bone matrix (DBM) for bone regeneration. This material has demonstrated the capacity to promote re-mineralization of the DBM particles within the scaffold struts and shows potential to promote successful spine fusion. Here, we investigate the role of geometry and architecture in osteointegration, vascularization, and facilitation of spine fusion in a pre-clinical model. Inks containing HA and DBM particles in a poly(lactide-co-glycolide) elastomer were 3D-printed into scaffolds with varying relative strut angles (90° vs. 45° advancing angle), macropore size (0 vs. 500 vs. 1000 μm), and strut alignment (aligned vs. offset). The following configurations were compared with scaffolds containing no macropores: 90°/500μm/aligned, 45°/500μm/aligned, 90°/1,000μm/aligned, 45°/1,000μm/aligned, 90°/1,000μm/offset, 45°/1,000μm/offset. Eighty-four female Sprague-Dawley rats underwent spine fusion with bilateral placement of the various scaffold configurations (n=12/configuration). Osteointegration and vascularization were assessed using microComputed Tomography and histology, and spine fusion was assessed via blinded manual palpation. The 45°/1,000μm scaffolds with aligned struts achieved the highest average fusion score (1.61/2) as well as the highest osteointegration score. Both the 45°/1,000μm/aligned and 90°/1,000μm/aligned scaffolds elicited fusion rates of 100%, which was significantly greater than the 45°/500μm/aligned iteration (p<0.05). All porous scaffolds were fully vascularized, with blood vessels present in every macropore. Vessels were also observed extending from the native transverse process bone, through the protrusions of new bone, and into the macropores of the scaffolds. When viewed independently, scaffolds printed with relative strut angles of 45° and 90° each allowed for osteointegration sufficient to stabilize the spine at L4-L5. Within those parameters, a pore size of 500 μm or greater was generally sufficient to achieve unilateral fusion. However, our results suggest that scaffolds printed with the larger pore size and with aligned struts at an advancing angle of 45° may represent the optimal configuration to maximize osteointegration and fusion capacity. Overall, this work suggests that the HA/DBM composite scaffolds provide a conducive environment for bone regeneration as well as vascular infiltration. This technology therefore represents a novel, growth-factor-free biomaterial with significant potential as a bone graft substitute for use in spinal surgery.
- 1 January 2021
- Published by SAGE Publications in Tissue Engineering Part A
- Vol. 27 (1-2) , 26-36
Open AccessInfluence of Geometry and Architecture on the In Vivo Success of 3D-Printed Scaffolds for Spinal Fusion
We previously developed a recombinant growth factor-free, 3D-printed material comprised of hydroxyapatite (HA) and demineralized bone matrix (DBM) for bone regeneration. This material has demonstrated the capacity to promote re-mineralization of the DBM particles within the scaffold struts and shows potential to promote successful spine fusion. Here, we investigate the role of geometry and architecture in osteointegration, vascularization, and facilitation of spine fusion in a pre-clinical model. Inks containing HA and DBM particles in a poly(lactide-co-glycolide) elastomer were 3D-printed into scaffolds with varying relative strut angles (90° vs. 45° advancing angle), macropore size (0 vs. 500 vs. 1000 μm), and strut alignment (aligned vs. offset). The following configurations were compared with scaffolds containing no macropores: 90°/500μm/aligned, 45°/500μm/aligned, 90°/1,000μm/aligned, 45°/1,000μm/aligned, 90°/1,000μm/offset, 45°/1,000μm/offset. Eighty-four female Sprague-Dawley rats underwent spine fusion with bilateral placement of the various scaffold configurations (n=12/configuration). Osteointegration and vascularization were assessed using microComputed Tomography and histology, and spine fusion was assessed via blinded manual palpation. The 45°/1,000μm scaffolds with aligned struts achieved the highest average fusion score (1.61/2) as well as the highest osteointegration score. Both the 45°/1,000μm/aligned and 90°/1,000μm/aligned scaffolds elicited fusion rates of 100%, which was significantly greater than the 45°/500μm/aligned iteration (p<0.05). All porous scaffolds were fully vascularized, with blood vessels present in every macropore. Vessels were also observed extending from the native transverse process bone, through the protrusions of new bone, and into the macropores of the scaffolds. When viewed independently, scaffolds printed with relative strut angles of 45° and 90° each allowed for osteointegration sufficient to stabilize the spine at L4-L5. Within those parameters, a pore size of 500 μm or greater was generally sufficient to achieve unilateral fusion. However, our results suggest that scaffolds printed with the larger pore size and with aligned struts at an advancing angle of 45° may represent the optimal configuration to maximize osteointegration and fusion capacity. Overall, this work suggests that the HA/DBM composite scaffolds provide a conducive environment for bone regeneration as well as vascular infiltration. This technology therefore represents a novel, growth-factor-free biomaterial with significant potential as a bone graft substitute for use in spinal surgery.