Kantapon Pum Wiboonsaksakul
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Kantapon Pum Wiboonsaksakul has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Kathleen E. Cullen
Department of Biomedical Engineering, Johns Hopkins University School of Medicine, Baltimore, USA
3 shared publications Charles C. Della Santina
Affiliation Department of Otolaryngology-Head and Neck Surgery, Johns Hopkins University School of Medicine; Baltimore, Maryland, United States of America
1 shared publicationDale C. Roberts
Affiliation Department of Biomedical Engineering, Johns Hopkins University School of Medicine; Baltimore, Maryland, United States of America
1 shared publication- Hui Ho Vanessa Chang
Department of Biomedical Engineering, Johns Hopkins University
1 shared publication Oliver R. Stanley
Department of Biomedical Engineering, Johns Hopkins University School of Medicine, Baltimore, MD, United States
1 shared publicationOlivia M.E. Leavitt
Department of Biomedical Engineering, Johns Hopkins University School of Medicine, Baltimore, MD, United States
1 shared publication
Latest Publications
- Open Access
- 17 December 2024
- Published by eLife Sciences Publications, Ltd in eLife
- Vol. 13
Restoring vestibular function during natural self-motion: Progress and challenges
The vestibular system is integral to behavior; the loss of peripheral vestibular function leads to disabling consequences, such as blurred vision, dizziness, and unstable posture, severely limiting activities of daily living. Fortunately, the vestibular system’s well-defined peripheral structure and well-understood encoding strategies offer unique opportunities for developing sensory prostheses to restore vestibular function. While these devices show promising results in both animal models and implanted patients, substantial room for improvement remains. Research from an engineering perspective has largely focused on optimizing stimulation protocol to improve outcomes. However, this approach has often been pursued in isolation from research in neuroscience that has enriched our understanding of neural responses at the synaptic, cellular, and circuit levels. Accordingly, this review bridges the domains of neuroscience and engineering to consider recent progress and challenges in vestibular prosthesis development. We advocate for interdisciplinary approaches that leverage studies of neural circuits at the population level, especially in light of recent advancement in large-scale recording technology, to identify impediments still to overcome and to develop more naturalistic stimulation strategies. Fully integrating neuroscience and engineering in the context of prosthesis development will help advance the field forward and ultimately improve patient outcomes.
- 17 December 2024
- Published by eLife Sciences Publications, Ltd in eLife
- Vol. 13
Open AccessRestoring vestibular function during natural self-motion: Progress and challenges
The vestibular system is integral to behavior; the loss of peripheral vestibular function leads to disabling consequences, such as blurred vision, dizziness, and unstable posture, severely limiting activities of daily living. Fortunately, the vestibular system’s well-defined peripheral structure and well-understood encoding strategies offer unique opportunities for developing sensory prostheses to restore vestibular function. While these devices show promising results in both animal models and implanted patients, substantial room for improvement remains. Research from an engineering perspective has largely focused on optimizing stimulation protocol to improve outcomes. However, this approach has often been pursued in isolation from research in neuroscience that has enriched our understanding of neural responses at the synaptic, cellular, and circuit levels. Accordingly, this review bridges the domains of neuroscience and engineering to consider recent progress and challenges in vestibular prosthesis development. We advocate for interdisciplinary approaches that leverage studies of neural circuits at the population level, especially in light of recent advancement in large-scale recording technology, to identify impediments still to overcome and to develop more naturalistic stimulation strategies. Fully integrating neuroscience and engineering in the context of prosthesis development will help advance the field forward and ultimately improve patient outcomes.
- Open Access
- 14 September 2022
- Published by Public Library of Science (PLoS) in PLOS Biology
- Vol. 20 (9) , e3001798
A prosthesis utilizing natural vestibular encoding strategies improves sensorimotor performance in monkeys
Sensory pathways provide complex and multifaceted information to the brain. Recent advances have created new opportunities for applying our understanding of the brain to sensory prothesis development. Yet complex sensor physiology, limited numbers of electrodes, and nonspecific stimulation have proven to be a challenge for many sensory systems. In contrast, the vestibular system is uniquely suited for prosthesis development. Its peripheral anatomy allows site-specific stimulation of 3 separate sensory organs that encode distinct directions of head motion. Accordingly, here, we investigated whether implementing natural encoding strategies improves vestibular prosthesis performance. The eye movements produced by the vestibulo-ocular reflex (VOR), which plays an essential role in maintaining visual stability, were measured to quantify performance. Overall, implementing the natural tuning dynamics of vestibular afferents produced more temporally accurate VOR eye movements. Exploration of the parameter space further revealed that more dynamic tunings were not beneficial due to saturation and unnatural phase advances. Trends were comparable for stimulation encoding virtual versus physical head rotations, with gains enhanced in the latter case. Finally, using computational methods, we found that the same simple model explained the eye movements evoked by sinusoidal and transient stimulation and that a stimulation efficacy substantially less than 100% could account for our results. Taken together, our results establish that prosthesis encodings that incorporate naturalistic afferent dynamics and account for activation efficacy are well suited for restoration of gaze stability. More generally, these results emphasize the benefits of leveraging the brain’s endogenous coding strategies in prosthesis development to improve functional outcomes.
- 14 September 2022
- Published by Public Library of Science (PLoS) in PLOS Biology
- Vol. 20 (9) , e3001798
Open AccessA prosthesis utilizing natural vestibular encoding strategies improves sensorimotor performance in monkeys
Sensory pathways provide complex and multifaceted information to the brain. Recent advances have created new opportunities for applying our understanding of the brain to sensory prothesis development. Yet complex sensor physiology, limited numbers of electrodes, and nonspecific stimulation have proven to be a challenge for many sensory systems. In contrast, the vestibular system is uniquely suited for prosthesis development. Its peripheral anatomy allows site-specific stimulation of 3 separate sensory organs that encode distinct directions of head motion. Accordingly, here, we investigated whether implementing natural encoding strategies improves vestibular prosthesis performance. The eye movements produced by the vestibulo-ocular reflex (VOR), which plays an essential role in maintaining visual stability, were measured to quantify performance. Overall, implementing the natural tuning dynamics of vestibular afferents produced more temporally accurate VOR eye movements. Exploration of the parameter space further revealed that more dynamic tunings were not beneficial due to saturation and unnatural phase advances. Trends were comparable for stimulation encoding virtual versus physical head rotations, with gains enhanced in the latter case. Finally, using computational methods, we found that the same simple model explained the eye movements evoked by sinusoidal and transient stimulation and that a stimulation efficacy substantially less than 100% could account for our results. Taken together, our results establish that prosthesis encodings that incorporate naturalistic afferent dynamics and account for activation efficacy are well suited for restoration of gaze stability. More generally, these results emphasize the benefits of leveraging the brain’s endogenous coding strategies in prosthesis development to improve functional outcomes.
- 1 January 2020
- Published by Elsevier
- p. 38-54
Information Processing in the Vestibular System