Yonatan E. Brand
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Yonatan E. Brand has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Aron S. Buchman
Rush Alzheimer’s Disease Center, Rush University Medical Center, Chicago, IL, 60612, USA
2 shared publications Alison J. Yarnall
Translational and Clinical Research Institute, Faculty of Medical Sciences, New-castle University
1 shared publicationAndrea Cereatti
Department of Electronics and Telecommunications
1 shared publicationArne Mueller
Biomedical Research
1 shared publicationBeatrix Vereijken
Department of Neuromedicine and Movement Science, Norwegian University of Science and Technology
1 shared publicationClemens Becker
Robert Bosch Gesellschaft für Medizinische Forschung
1 shared publication
Latest Publications
- Open Access
Continuous Assessment of Daily-Living Gait Using Self-Supervised Learning of Wrist-Worn Accelerometer Data
Physical activity and mobility are critical for healthy aging and predict diverse health outcomes. While wrist-worn accelerometers are widely used to monitor physical activity, estimating gait metrics from wrist data remains challenging. We extend ElderNet, a self-supervised deep-learning model previously validated for walking-bout detection, to estimate gait metrics from wrist accelerometry. Validation involved 819 older adults (Rush-Memory-and-Aging-Project) and 85 individuals with gait impairments (Mobilise-D), from six medical centers. In Mobilise-D, ElderNet achieved an absolute error of 8.82 cm/s and an intra-class correlation of 0.87 for gait speed, outperforming state-of-the-art methods (p < 0.001) and models using a lower-back sensor. ElderNet outperformed (percentage error; p < 0.01) competing approaches in estimating cadence and stride length, and better (p < 0.01) classified mobility disability (AUC = 0.80) than conventional gait or physical activity metrics. These results render ElderNet a scalable tool for gait assessment using wrist-worn devices in aging and clinical populations.
Open AccessContinuous Assessment of Daily-Living Gait Using Self-Supervised Learning of Wrist-Worn Accelerometer Data
Physical activity and mobility are critical for healthy aging and predict diverse health outcomes. While wrist-worn accelerometers are widely used to monitor physical activity, estimating gait metrics from wrist data remains challenging. We extend ElderNet, a self-supervised deep-learning model previously validated for walking-bout detection, to estimate gait metrics from wrist accelerometry. Validation involved 819 older adults (Rush-Memory-and-Aging-Project) and 85 individuals with gait impairments (Mobilise-D), from six medical centers. In Mobilise-D, ElderNet achieved an absolute error of 8.82 cm/s and an intra-class correlation of 0.87 for gait speed, outperforming state-of-the-art methods (p < 0.001) and models using a lower-back sensor. ElderNet outperformed (percentage error; p < 0.01) competing approaches in estimating cadence and stride length, and better (p < 0.01) classified mobility disability (AUC = 0.80) than conventional gait or physical activity metrics. These results render ElderNet a scalable tool for gait assessment using wrist-worn devices in aging and clinical populations.
- Open Access
Gait Detection from a Wrist-Worn Sensor Using Machine Learning Methods: A Daily Living Study in Older Adults and People with Parkinson’s Disease
Remote assessment of the gait of older adults (OAs) during daily living using wrist-worn sensors has the potential to augment clinical care and mobility research. However, hand movements can degrade gait detection from wrist-sensor recordings. To address this challenge, we developed an anomaly detection algorithm and compared its performance to four previously published gait detection algorithms. Multiday accelerometer recordings from a wrist-worn and lower-back sensor (i.e., the “gold-standard” reference) were obtained in 30 OAs, 60% with Parkinson’s disease (PD). The area under the receiver operator curve (AUC) and the area under the precision–recall curve (AUPRC) were used to evaluate the performance of the algorithms. The anomaly detection algorithm obtained AUCs of 0.80 and 0.74 for OAs and PD, respectively, but AUPRCs of 0.23 and 0.31 for OAs and PD, respectively. The best performing detection algorithm, a deep convolutional neural network (DCNN), exhibited high AUCs (i.e., 0.94 for OAs and 0.89 for PD) but lower AUPRCs (i.e., 0.66 for OAs and 0.60 for PD), indicating trade-offs between precision and recall. When choosing a classification threshold of 0.9 (i.e., opting for high precision) for the DCNN algorithm, strong correlations (r > 0.8) were observed between daily living walking time estimates based on the lower-back (reference) sensor and the wrist sensor. Further, gait quality measures were significantly different in OAs and PD compared to healthy adults. These results demonstrate that daily living gait can be quantified using a wrist-worn sensor.
Open AccessGait Detection from a Wrist-Worn Sensor Using Machine Learning Methods: A Daily Living Study in Older Adults and People with Parkinson’s Disease
Remote assessment of the gait of older adults (OAs) during daily living using wrist-worn sensors has the potential to augment clinical care and mobility research. However, hand movements can degrade gait detection from wrist-sensor recordings. To address this challenge, we developed an anomaly detection algorithm and compared its performance to four previously published gait detection algorithms. Multiday accelerometer recordings from a wrist-worn and lower-back sensor (i.e., the “gold-standard” reference) were obtained in 30 OAs, 60% with Parkinson’s disease (PD). The area under the receiver operator curve (AUC) and the area under the precision–recall curve (AUPRC) were used to evaluate the performance of the algorithms. The anomaly detection algorithm obtained AUCs of 0.80 and 0.74 for OAs and PD, respectively, but AUPRCs of 0.23 and 0.31 for OAs and PD, respectively. The best performing detection algorithm, a deep convolutional neural network (DCNN), exhibited high AUCs (i.e., 0.94 for OAs and 0.89 for PD) but lower AUPRCs (i.e., 0.66 for OAs and 0.60 for PD), indicating trade-offs between precision and recall. When choosing a classification threshold of 0.9 (i.e., opting for high precision) for the DCNN algorithm, strong correlations (r > 0.8) were observed between daily living walking time estimates based on the lower-back (reference) sensor and the wrist sensor. Further, gait quality measures were significantly different in OAs and PD compared to healthy adults. These results demonstrate that daily living gait can be quantified using a wrist-worn sensor.