Deepak Prakash Kadam
Research Subjects
Deepak Prakash Kadam has a total of 33 co-authors. Here are the top co-authors by number of shared publications:
- Mohan Thakre
Walchand College of Engineering
11 shared publications - Sunil Somnath Kadlag
Amrutvahini College of Engineering
10 shared publications - Pawan C. Tapre
S.N.D. College of Engineering and Research Center
7 shared publications - Rahul Mapari
Pimpri Chinchwad College of Engineering and Research
5 shared publications - Rakesh Ghanshyamlal Shriwastava
Govindrao Wanjari College of Engineering and Technology
5 shared publications - Busireddy Hemanth Kumar
Department of Electrical and Electronics Engineering, Mohan Babu University (Erstwhile Sree Vidyanikethan Engineering College), Tirupati, India
2 shared publications
Latest Publications
- Open Access
- 15 January 2024
- Published by El-Cezeri: Journal of Science and Engineering in El-Cezeri Fen ve Mühendislik Dergisi
A Single Source Thirteen Level Switched Capacitor Boost Inverter for PV applications
This work proposes a module unit (MU) based single-source thirteen-level inverter (SSTLI) for solar PV applications. The proposed topology is 13-level design with single MU and 1.5 voltage gain. This work describes its operational modes at various output levels. Due to their symmetric functioning within a cycle, two capacitors were series-connected. with MU may achieve self-voltage balancing, which reduces complexity of control compared to typical Multilevel inverters (MLIs). The single-source generalized structure with additional MUs can be utilized in order to boost voltage levels for the output. With more MU, voltage gain increases, in addition the output levels are greatly enhanced. The merits of the proposed SSTLI are fewer components, self-balance, voltage stress. A comparison between proposed topology and other MLIs is shown in this work. To determine viability and dynamic performance of proposed SSTLI, MATLAB simulation results are presented for dynamic values of Modulation Index (M) for different loads along with the harmonic analysis. Experimental results also have been presented for the practicality of SSTLI topology.
- 15 January 2024
- Published by El-Cezeri: Journal of Science and Engineering in El-Cezeri Fen ve Mühendislik Dergisi
Open AccessA Single Source Thirteen Level Switched Capacitor Boost Inverter for PV applications
This work proposes a module unit (MU) based single-source thirteen-level inverter (SSTLI) for solar PV applications. The proposed topology is 13-level design with single MU and 1.5 voltage gain. This work describes its operational modes at various output levels. Due to their symmetric functioning within a cycle, two capacitors were series-connected. with MU may achieve self-voltage balancing, which reduces complexity of control compared to typical Multilevel inverters (MLIs). The single-source generalized structure with additional MUs can be utilized in order to boost voltage levels for the output. With more MU, voltage gain increases, in addition the output levels are greatly enhanced. The merits of the proposed SSTLI are fewer components, self-balance, voltage stress. A comparison between proposed topology and other MLIs is shown in this work. To determine viability and dynamic performance of proposed SSTLI, MATLAB simulation results are presented for dynamic values of Modulation Index (M) for different loads along with the harmonic analysis. Experimental results also have been presented for the practicality of SSTLI topology.
- Open Access
- 1 December 2023
- Published by Institute of Advanced Engineering and Science in Bulletin of Electrical Engineering and Informatics
- Vol. 12 (6) , 3179-3189
The novel strategy of electrical arc furnace design and control approach for voltage flicker investigation
Voltage flickers and harmonics are power quality (PQ) problems in the electric system during a variation and arc furnace (AF) adaptability. AF creations must determine a harmonic and flicker. This article evaluates complex AF systems. This article presents a newly established time domain (TD) static become to on an AF's V-I attributes (VIA). Static arc configurations are useful for harmonic analyses, but dynamic methods are needed for PQ studies, especially voltage flicker analysis. The MATLAB-based dynamic AF configuration is simulated for four different configurations. A response with configurations 1 and 4 varies from the real AF outcomes. The simulation results and numerical finding shows that configurations 2 and 3 are much more appropriate and produce better results for minimum 3rd harmonics for arc current, arc voltage, and point of common coupling (PCC) voltage. The novelty of this configuration is that the energy transferred to the load by the AF during the cycle of operation has been identified, making the developed scheme more reliable and dependent on the load's operational conditions. After that, effective applications of these configurations and other configurations' accuracy should be clarified.
- 1 December 2023
- Published by Institute of Advanced Engineering and Science in Bulletin of Electrical Engineering and Informatics
- Vol. 12 (6) , 3179-3189
Open AccessThe novel strategy of electrical arc furnace design and control approach for voltage flicker investigation
Voltage flickers and harmonics are power quality (PQ) problems in the electric system during a variation and arc furnace (AF) adaptability. AF creations must determine a harmonic and flicker. This article evaluates complex AF systems. This article presents a newly established time domain (TD) static become to on an AF's V-I attributes (VIA). Static arc configurations are useful for harmonic analyses, but dynamic methods are needed for PQ studies, especially voltage flicker analysis. The MATLAB-based dynamic AF configuration is simulated for four different configurations. A response with configurations 1 and 4 varies from the real AF outcomes. The simulation results and numerical finding shows that configurations 2 and 3 are much more appropriate and produce better results for minimum 3rd harmonics for arc current, arc voltage, and point of common coupling (PCC) voltage. The novelty of this configuration is that the energy transferred to the load by the AF during the cycle of operation has been identified, making the developed scheme more reliable and dependent on the load's operational conditions. After that, effective applications of these configurations and other configurations' accuracy should be clarified.
- Open Access
- 1 December 2023
- Published by Institute of Advanced Engineering and Science in Bulletin of Electrical Engineering and Informatics
- Vol. 12 (6) , 3228-3237
Integration of storage technology oversight: power system and computer engineering analogy
Energy storage, analogous to data storage in a computer system, is one of the enabling technologies that has emerged alongside the widespread use of renewable energy sources in the nation's power grid. This article shows that the underlying platforms for storing data and energy are quite similar. Batteries and hydrogen storage offer significant energy potential, much like a hard disk for storing vast amounts of data in a computer's central processing unit (CPU). A supercapacitor or flywheel storage device can be used to have emergency power on hand, with access times as fast as random access memory (RAM) in modern computers. In this study, we propose an energy-control scheme for caches that is akin to computer engineering and is used to coordinate the operation of multilevel storage systems that incorporate both capacity and access-oriented storage. By supporting the energy-management system, which in turn provides modern plug-and-play functionality, cache energy control helps optimise the system as a whole. Such an integrated system calls for renewable energy generation, local loads, fueling stations, and connections to gas and electric distribution grids. Distribution energy concepts with various storage systems can be easily grasped by drawing parallels between computer engineering and power system integration.
- 1 December 2023
- Published by Institute of Advanced Engineering and Science in Bulletin of Electrical Engineering and Informatics
- Vol. 12 (6) , 3228-3237
Open AccessIntegration of storage technology oversight: power system and computer engineering analogy
Energy storage, analogous to data storage in a computer system, is one of the enabling technologies that has emerged alongside the widespread use of renewable energy sources in the nation's power grid. This article shows that the underlying platforms for storing data and energy are quite similar. Batteries and hydrogen storage offer significant energy potential, much like a hard disk for storing vast amounts of data in a computer's central processing unit (CPU). A supercapacitor or flywheel storage device can be used to have emergency power on hand, with access times as fast as random access memory (RAM) in modern computers. In this study, we propose an energy-control scheme for caches that is akin to computer engineering and is used to coordinate the operation of multilevel storage systems that incorporate both capacity and access-oriented storage. By supporting the energy-management system, which in turn provides modern plug-and-play functionality, cache energy control helps optimise the system as a whole. Such an integrated system calls for renewable energy generation, local loads, fueling stations, and connections to gas and electric distribution grids. Distribution energy concepts with various storage systems can be easily grasped by drawing parallels between computer engineering and power system integration.
- Open Access
- 1 December 2023
- Published by Institute of Advanced Engineering and Science in Bulletin of Electrical Engineering and Informatics
- Vol. 12 (6) , 3190-3201
Implementation of a P&E management system for a dual-source EV powered by different batteries
There is an era started in the field of power energy (PE) management in the electric vehicles (EVs) application cloud, which impacts the smart grid in significant ways and necessitates the collaboration of multiple branches of engineering. Most of the problems with EVs stem from their limited range, which can be improved by incorporating additional forms of energy storage. This paper makes an effort to bring a fresh viewpoint to the description of the power and energy management problem facing EV, taking into account all the needs of such a vehicle. Using a novel power and energy management system, the proposed methodology enables a systematic approach to this multidisciplinary problem. Implementing a power and energy management system for a dual-source EV using lead-acid batteries and ultra-capacitors (UCs) exemplifies the novel framework's capabilities. The electronic power development architecture is outlined in detail, along with the implementing modular blocks that make up the entire system architecture.
- 1 December 2023
- Published by Institute of Advanced Engineering and Science in Bulletin of Electrical Engineering and Informatics
- Vol. 12 (6) , 3190-3201
Open AccessImplementation of a P&E management system for a dual-source EV powered by different batteries
There is an era started in the field of power energy (PE) management in the electric vehicles (EVs) application cloud, which impacts the smart grid in significant ways and necessitates the collaboration of multiple branches of engineering. Most of the problems with EVs stem from their limited range, which can be improved by incorporating additional forms of energy storage. This paper makes an effort to bring a fresh viewpoint to the description of the power and energy management problem facing EV, taking into account all the needs of such a vehicle. Using a novel power and energy management system, the proposed methodology enables a systematic approach to this multidisciplinary problem. Implementing a power and energy management system for a dual-source EV using lead-acid batteries and ultra-capacitors (UCs) exemplifies the novel framework's capabilities. The electronic power development architecture is outlined in detail, along with the implementing modular blocks that make up the entire system architecture.
- Open Access
- 1 October 2023
- Published by Institute of Advanced Engineering and Science in Bulletin of Electrical Engineering and Informatics
- Vol. 12 (5) , 2682-2692
Performance analysis of FOC space vector modulation DCMLI driven PMSM drive
The effectiveness of a permanent magnet synchronous motor (PMSM) drive managed by an automatic voltage regulator (AVR) microcontroller using field oriented control (FOC) with space vector modulation (SVM) and a diode clamped multilevel inverter (DCMLI) is investigated. Due to its efficacy, FOC would be widely implemented for PMSM speed regulation. The primary drawbacks of a 3-phase classic bridge inverter appear to be reduced dv/dt stresses, lesser electromagnetic interference, and a relatively small rating, especially when compared to inverters. PMSMs have a better chance of being adopted in the automotive industry because of their compact size, high efficiency, and durability. The SVM idea states that an inverter's three driving signals are created simultaneously. Using MATLAB simulations, researchers looked into incorporating a DCMLI with a resistive load on an AVR microcontroller. Torque, current, and harmonic analysis were evaluated between the SVM and the inverter-driven PMSM drive in this research. In comparison to the prior art, the proposed PMSM drive has better speed and torque management, less output distortion, and less harmonic distortion.
- 1 October 2023
- Published by Institute of Advanced Engineering and Science in Bulletin of Electrical Engineering and Informatics
- Vol. 12 (5) , 2682-2692
Open AccessPerformance analysis of FOC space vector modulation DCMLI driven PMSM drive
The effectiveness of a permanent magnet synchronous motor (PMSM) drive managed by an automatic voltage regulator (AVR) microcontroller using field oriented control (FOC) with space vector modulation (SVM) and a diode clamped multilevel inverter (DCMLI) is investigated. Due to its efficacy, FOC would be widely implemented for PMSM speed regulation. The primary drawbacks of a 3-phase classic bridge inverter appear to be reduced dv/dt stresses, lesser electromagnetic interference, and a relatively small rating, especially when compared to inverters. PMSMs have a better chance of being adopted in the automotive industry because of their compact size, high efficiency, and durability. The SVM idea states that an inverter's three driving signals are created simultaneously. Using MATLAB simulations, researchers looked into incorporating a DCMLI with a resistive load on an AVR microcontroller. Torque, current, and harmonic analysis were evaluated between the SVM and the inverter-driven PMSM drive in this research. In comparison to the prior art, the proposed PMSM drive has better speed and torque management, less output distortion, and less harmonic distortion.
- Open Access
- 1 October 2023
- Published by Institute of Advanced Engineering and Science in Bulletin of Electrical Engineering and Informatics
- Vol. 12 (5) , 2577-2585
A versatile methodology for preventing a parallel transmission system using impedance-based techniques
The various configurations that exist for a compatible circuit depend on an object, such as operating conditions, the occurrence of an inter-circuit error and the result of the coupling of the transmission line. This feature makes the protection of the same transmission lines very difficult. This paper introduces a new algorithm based on a state diagram that contains location data collected on a passing bus. Combine the different separation processes and the impedance-based process is used. The classification process cannot detect internal errors and only compares with existing phases where the same regional error occurs in the 2D space and the impedance-based method used to cover the resulting error. The proposed algorithm incorporates impedance-based methodology and separation technology to provide the appropriate response under all operating conditions of the same circuits.
- 1 October 2023
- Published by Institute of Advanced Engineering and Science in Bulletin of Electrical Engineering and Informatics
- Vol. 12 (5) , 2577-2585
Open AccessA versatile methodology for preventing a parallel transmission system using impedance-based techniques
The various configurations that exist for a compatible circuit depend on an object, such as operating conditions, the occurrence of an inter-circuit error and the result of the coupling of the transmission line. This feature makes the protection of the same transmission lines very difficult. This paper introduces a new algorithm based on a state diagram that contains location data collected on a passing bus. Combine the different separation processes and the impedance-based process is used. The classification process cannot detect internal errors and only compares with existing phases where the same regional error occurs in the 2D space and the impedance-based method used to cover the resulting error. The proposed algorithm incorporates impedance-based methodology and separation technology to provide the appropriate response under all operating conditions of the same circuits.
- Open Access
- 23 September 2023
- Published by El-Cezeri: Journal of Science and Engineering in El-Cezeri Fen ve Mühendislik Dergisi
- Vol. 10 (3) , 517-525
A Five Level SC Inverter with reduced switch count and self balancing capability
Multilevel inverters (MLIs) have become a favoured option for medium voltage and high power DC to AC conversion applications to assure high power level cascade type inverter which accepts multiple/single DC sources and offers combined AC output for appropriate voltage and frequency. MLIs provide various benefits over two-level inverters, including lower dv/dt, the capacity to handle greater voltage levels, a quasi-sinusoidal output waveform, and lower Total Harmonic Distortion (THD), among others. The biggest problem in adopting the MLI is the increasing number of switches and it's design. MLIs based on switched capacitors (SC) for boost-type DC-AC converters often demonstrate a trade-off among switch voltage rating and switch count. This work introduces a new 5-level(5L) SC inverter by adding a switched capacitor module into the usual 3L neutral point clamped inverter leg(NPC). The SC unit consists of one bidirectional switch and two capacitors capable of withstanding one-quarter of the DC voltage. When compared to typical 5L inverters, such as standard NPC and active NPC designs, the new approach in addition reduces the amount of switches but also shorten the topology. The proposed FLSCI has been examined by using several PWM techniques. The simulation and hardware results showed that the presented FLSCI is ideal for a broad variety of applications.
- 23 September 2023
- Published by El-Cezeri: Journal of Science and Engineering in El-Cezeri Fen ve Mühendislik Dergisi
- Vol. 10 (3) , 517-525
Open AccessA Five Level SC Inverter with reduced switch count and self balancing capability
Multilevel inverters (MLIs) have become a favoured option for medium voltage and high power DC to AC conversion applications to assure high power level cascade type inverter which accepts multiple/single DC sources and offers combined AC output for appropriate voltage and frequency. MLIs provide various benefits over two-level inverters, including lower dv/dt, the capacity to handle greater voltage levels, a quasi-sinusoidal output waveform, and lower Total Harmonic Distortion (THD), among others. The biggest problem in adopting the MLI is the increasing number of switches and it's design. MLIs based on switched capacitors (SC) for boost-type DC-AC converters often demonstrate a trade-off among switch voltage rating and switch count. This work introduces a new 5-level(5L) SC inverter by adding a switched capacitor module into the usual 3L neutral point clamped inverter leg(NPC). The SC unit consists of one bidirectional switch and two capacitors capable of withstanding one-quarter of the DC voltage. When compared to typical 5L inverters, such as standard NPC and active NPC designs, the new approach in addition reduces the amount of switches but also shorten the topology. The proposed FLSCI has been examined by using several PWM techniques. The simulation and hardware results showed that the presented FLSCI is ideal for a broad variety of applications.
- Open Access
- 1 August 2023
- Published by Institute of Advanced Engineering and Science in Bulletin of Electrical Engineering and Informatics
- Vol. 12 (4) , 1947-1959
Pulse charging based intelligent battery management system for electric vehicle
Electric vehicles (EVs) are now an important part of the automotive industry for two main reasons: decreased reliance on oil and reduced air pollution, which helps us contribute to the development of an environmentally friendly environment. EV buyers examine overall vehicle mileage, recharge time, vehicle mileage after every charge, batteries charging/discharging security, lifespan, charged rate, capability, and temperature increase. A new improved pulse charging technique is proposed, in which the battery is charged using proportional integral derivative (PID) control action and a neural network. A PID controller is used to develop the charging unit in this design. The feed forward neural network was used to determine the values of the PID control parameters. The battery management system (BMS) ensures that this designed battery charging system takes less time to charge the battery efficiently. The system is built with MATLAB/Simulink.
- 1 August 2023
- Published by Institute of Advanced Engineering and Science in Bulletin of Electrical Engineering and Informatics
- Vol. 12 (4) , 1947-1959
Open AccessPulse charging based intelligent battery management system for electric vehicle
Electric vehicles (EVs) are now an important part of the automotive industry for two main reasons: decreased reliance on oil and reduced air pollution, which helps us contribute to the development of an environmentally friendly environment. EV buyers examine overall vehicle mileage, recharge time, vehicle mileage after every charge, batteries charging/discharging security, lifespan, charged rate, capability, and temperature increase. A new improved pulse charging technique is proposed, in which the battery is charged using proportional integral derivative (PID) control action and a neural network. A PID controller is used to develop the charging unit in this design. The feed forward neural network was used to determine the values of the PID control parameters. The battery management system (BMS) ensures that this designed battery charging system takes less time to charge the battery efficiently. The system is built with MATLAB/Simulink.
- Open Access
- 1 August 2023
- Published by Institute of Advanced Engineering and Science in Bulletin of Electrical Engineering and Informatics
- Vol. 12 (4) , 1947-1959
Pulse charging based intelligent battery management system for electric vehicle
Electric vehicles (EVs) are now an important part of the automotive industry for two main reasons: decreased reliance on oil and reduced air pollution, which helps us contribute to the development of an environmentally friendly environment. EV buyers examine overall vehicle mileage, recharge time, vehicle mileage after every charge, batteries charging/discharging security, lifespan, charged rate, capability, and temperature increase. A new improved pulse charging technique is proposed, in which the battery is charged using proportional integral derivative (PID) control action and a neural network. A PID controller is used to develop the charging unit in this design. The feed forward neural network was used to determine the values of the PID control parameters. The battery management system (BMS) ensures that this designed battery charging system takes less time to charge the battery efficiently. The system is built with MATLAB/Simulink.
- 1 August 2023
- Published by Institute of Advanced Engineering and Science in Bulletin of Electrical Engineering and Informatics
- Vol. 12 (4) , 1947-1959
Open AccessPulse charging based intelligent battery management system for electric vehicle
Electric vehicles (EVs) are now an important part of the automotive industry for two main reasons: decreased reliance on oil and reduced air pollution, which helps us contribute to the development of an environmentally friendly environment. EV buyers examine overall vehicle mileage, recharge time, vehicle mileage after every charge, batteries charging/discharging security, lifespan, charged rate, capability, and temperature increase. A new improved pulse charging technique is proposed, in which the battery is charged using proportional integral derivative (PID) control action and a neural network. A PID controller is used to develop the charging unit in this design. The feed forward neural network was used to determine the values of the PID control parameters. The battery management system (BMS) ensures that this designed battery charging system takes less time to charge the battery efficiently. The system is built with MATLAB/Simulink.
- Open Access
- 15 June 2023
- Published by Faculty of Engineering, University of Kragujevac in Proceedings on Engineering Sciences
- Vol. 5 (2) , 285-292
EVALUATION OF GENERATION AND TRANSMISSION ASSETS ON NODAL PRICES IN ELECTRICITY MARKETS
- 15 June 2023
- Published by Faculty of Engineering, University of Kragujevac in Proceedings on Engineering Sciences
- Vol. 5 (2) , 285-292
Open AccessEVALUATION OF GENERATION AND TRANSMISSION ASSETS ON NODAL PRICES IN ELECTRICITY MARKETS