Taha Mohamed Alfawwal
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Taha Mohamed Alfawwal has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
Alkhalaqi
Radiology department in Makkah Region Department of Medical Physics
1 shared publicationAllehyani
Radiation Protection Department Nuclear Research Center Atomic Energy Authority . P.O. 13759 Cairo Egypt
1 shared publicationAnas Alaa Mihdhir
Physics department, Faculty of applied science, Umm AlQura University
1 shared publicationEl Saadani
1 shared publicationF.H. Al-Ghorabie
1 shared publicationH Khalaf
Physics Department Faculty of Applied Sciences Umm Al-Quraa University KSA
1 shared publication
Latest Publications
- Open Access
- 15 October 2025
- Published by Elsevier in Journal of Radiation Research and Applied Sciences
- Vol. 18 (4)
Natural radioactivity and radiological risk assessment of soil samples from greater Cairo
- 15 October 2025
- Published by Elsevier in Journal of Radiation Research and Applied Sciences
- Vol. 18 (4)
Open AccessNatural radioactivity and radiological risk assessment of soil samples from greater Cairo
- Open Access
- 9 July 2024
- Published by Springer Nature in Research Square
Assessment of Radiological Impacts for Individuals Associated with Natural Occurring Radioactive Materials in Ceramic Industry
There is a trend in public worldwide to use ceramic tiles in domestic decoration , monitoring the radiation risk for individuals due to used ceramic materials is needed. The current study aims at assessing the radiological impact to individuals associated with natural radioactivity levels in ceramic materials. The specific activity of natural radionuclides was measured in the investigated ceramic materials using high purity germanium detector gamma spectrometry (HPGe) with 25% coaxial efficiency. The raw materials of the ceramic are made of a mixture of bicarbonate perc, clay, feldspar, glass sand, limestone, talc, kaolin minerals, and zalouky and zirconium silicates. The Radium equivalent activity, annual effective dose, and external hazard indexes (Hex) and excess cancer life risk (ECLR) were assessed using standard protocols. The present results indicated that the annual effective dose resulting from 226Ra, 232Th, 40K is within dose constrains and lower than the public dose limit recommended by ICRP.
- 9 July 2024
- Published by Springer Nature in Research Square
Open AccessAssessment of Radiological Impacts for Individuals Associated with Natural Occurring Radioactive Materials in Ceramic Industry
There is a trend in public worldwide to use ceramic tiles in domestic decoration , monitoring the radiation risk for individuals due to used ceramic materials is needed. The current study aims at assessing the radiological impact to individuals associated with natural radioactivity levels in ceramic materials. The specific activity of natural radionuclides was measured in the investigated ceramic materials using high purity germanium detector gamma spectrometry (HPGe) with 25% coaxial efficiency. The raw materials of the ceramic are made of a mixture of bicarbonate perc, clay, feldspar, glass sand, limestone, talc, kaolin minerals, and zalouky and zirconium silicates. The Radium equivalent activity, annual effective dose, and external hazard indexes (Hex) and excess cancer life risk (ECLR) were assessed using standard protocols. The present results indicated that the annual effective dose resulting from 226Ra, 232Th, 40K is within dose constrains and lower than the public dose limit recommended by ICRP.
- Open Access
- 5 February 2024
- Published by Springer Nature in Research Square
Internal Dosimetry for Individuals Following Inhalation of Radionuclides
Background: Owing to the increasing use of radioisotopes whether in nuclear medicine or research. The current research paper uses a whole-body counter to assess internal contamination for individuals working in nuclear medicine and research laboratories. High purity germanium detector Whole Body Counter with a relative efficiency of 25%; aluminum endcap with 1.5 mm was calibrated using a mixed gamma source. It consists of three parts; high purity germanium detector gamma ray spectrometer, shielding room, and Phantom. Gamma internal monitoring was performed on eight volunteers inhaled with 131I and two individuals contaminated with 99mTc in organ geometry. Results: The committed effective dose for individuals was lower than dose constrain and within the dose limit according to ICRP recommendations. Conclusions: The study indicates that the HpGe whole body counter has the capability to detect organ contamination such as 131I in thyroid gland, 99mTc in whole body geometry.
- 5 February 2024
- Published by Springer Nature in Research Square
Open AccessInternal Dosimetry for Individuals Following Inhalation of Radionuclides
Background: Owing to the increasing use of radioisotopes whether in nuclear medicine or research. The current research paper uses a whole-body counter to assess internal contamination for individuals working in nuclear medicine and research laboratories. High purity germanium detector Whole Body Counter with a relative efficiency of 25%; aluminum endcap with 1.5 mm was calibrated using a mixed gamma source. It consists of three parts; high purity germanium detector gamma ray spectrometer, shielding room, and Phantom. Gamma internal monitoring was performed on eight volunteers inhaled with 131I and two individuals contaminated with 99mTc in organ geometry. Results: The committed effective dose for individuals was lower than dose constrain and within the dose limit according to ICRP recommendations. Conclusions: The study indicates that the HpGe whole body counter has the capability to detect organ contamination such as 131I in thyroid gland, 99mTc in whole body geometry.
- 1 May 2023
- Published by ACS Publisher in Journal of Nuclear Technology in Applied Science
- Vol. 11 (1) , 13-18
Calibration of Whole Body Counter in Diagnostic and Screening Modes.
TThe current study aims to calibrate High Purity Germanium (HPGe), Whole-Body Counter. Four locations on the transfer phantom were considered to calculate the mean photo peak efficiency of the standard mixed gamma source. Photo peak efficiency of the HPGe detector at static, thyroid, diagnostic, and screening whole-body configurations for 88– 1836 KeV was carried out. The minimum detectable activity values for some radionuclides such as 131I, 137Cs and 60Co were calculated. The energy resolution of the HpGe whole-body counter for the energy range 88–1836 KeV was recorded as the mean value of 1%. The effective dose for volunteers contaminated with 131I ranged from 13 µSv to 66 µSv. The efficiency for four compartments of fixed screening whole-body configuration was higher than the corresponding value at diagnostic whole-body geometry by a factor of three. This makes the HPGe detector configuration good suitable for monitoring the low activity of internal contamination radionuclides.
- 1 May 2023
- Published by ACS Publisher in Journal of Nuclear Technology in Applied Science
- Vol. 11 (1) , 13-18
Calibration of Whole Body Counter in Diagnostic and Screening Modes.
TThe current study aims to calibrate High Purity Germanium (HPGe), Whole-Body Counter. Four locations on the transfer phantom were considered to calculate the mean photo peak efficiency of the standard mixed gamma source. Photo peak efficiency of the HPGe detector at static, thyroid, diagnostic, and screening whole-body configurations for 88– 1836 KeV was carried out. The minimum detectable activity values for some radionuclides such as 131I, 137Cs and 60Co were calculated. The energy resolution of the HpGe whole-body counter for the energy range 88–1836 KeV was recorded as the mean value of 1%. The effective dose for volunteers contaminated with 131I ranged from 13 µSv to 66 µSv. The efficiency for four compartments of fixed screening whole-body configuration was higher than the corresponding value at diagnostic whole-body geometry by a factor of three. This makes the HPGe detector configuration good suitable for monitoring the low activity of internal contamination radionuclides.
- 12 October 2022
- Published by Egyptian Knowledge Bank in Arab Journal of Nuclear Sciences and Applications
- Vol. 56 (1) , 1-5
Radiation Dose to Radiosensitive Organs during Head/Sinus Computed Tomography Procedure.
The current study aims to measure the entrance surface air kerma and absorbed dose to radiosensitive organs such as eyes and thyroid glands, due to scattered radiation during head/ sinus Computed Tomography (CT) scan. The entrance surface air kerma (ESAK) and absorbed dose for the eyes and thyroid of the Rando phantom’s head were evaluated by distribution of the standardized thermoluminescence dosimeters at the surface and 10 mm depth for slices for eye and thyroid sections. The ESAK for eyes and thyroid during head/sinus CT examinations was, as follows: 29.73± 1.63 mGy for eyes and 26.12 ± 1.51 mGy for thyroid . The mean absorbed dose of Hp (10) to eyes and thyroid during the Rando phantom’s head CT were 1.86 ± 0.02 mGy and 1.59 ± 0.08 mGy, respectively. The scientific study concluded that lowering scan length for the sinus CT scan is necessary to minimize a scattered dose to radiosensitive organs.
- 12 October 2022
- Published by Egyptian Knowledge Bank in Arab Journal of Nuclear Sciences and Applications
- Vol. 56 (1) , 1-5
Radiation Dose to Radiosensitive Organs during Head/Sinus Computed Tomography Procedure.
The current study aims to measure the entrance surface air kerma and absorbed dose to radiosensitive organs such as eyes and thyroid glands, due to scattered radiation during head/ sinus Computed Tomography (CT) scan. The entrance surface air kerma (ESAK) and absorbed dose for the eyes and thyroid of the Rando phantom’s head were evaluated by distribution of the standardized thermoluminescence dosimeters at the surface and 10 mm depth for slices for eye and thyroid sections. The ESAK for eyes and thyroid during head/sinus CT examinations was, as follows: 29.73± 1.63 mGy for eyes and 26.12 ± 1.51 mGy for thyroid . The mean absorbed dose of Hp (10) to eyes and thyroid during the Rando phantom’s head CT were 1.86 ± 0.02 mGy and 1.59 ± 0.08 mGy, respectively. The scientific study concluded that lowering scan length for the sinus CT scan is necessary to minimize a scattered dose to radiosensitive organs.
- Open Access
- 12 September 2022
- Published by Elsevier in Journal of Radiation Research and Applied Sciences
- Vol. 15 (3) , 353-356
Estimation of the total body burden for some individuals using whole body counter
- 12 September 2022
- Published by Elsevier in Journal of Radiation Research and Applied Sciences
- Vol. 15 (3) , 353-356
Open AccessEstimation of the total body burden for some individuals using whole body counter
- 1 January 2020
- Published by ACS Publisher in Journal of Nuclear Technology in Applied Science
- Vol. 8 (1) , 7-14
Assessment of Diagnostic Reference Dose Associated with Computed Tomography Examination
The current study is aimed to estimate the diagnostic reference dose levels (DRLs), the volume computer tomogram dose index (CTDIvol), the CT air kerma-length product (PKL,CT) and the effective dose (E) for head, chest and chest-abdomen-pelvic CT examinations performed on adults in King Abdullah Medical City (KAMC), Saudi Arabia. Demographic parameters (such as age, gender, weight, height) for a sample of 535 computed tomography (CT) patients and physical scan parameters (such as patient tube voltage (kV), reference and effective mill ampere-second (mAs), scan length, number of slices, and pitch factor) were collected from a picture archiving and communication system (PACS). CTDIvol and PKL,CT were studied for different patients weights (40 -60 kg, 60-80 kg, 80-100 kg and 100-120 kg). Mean CTDIvol, PKL,CT and effective dose for a standard weight (70 kg ±10%) was evaluated according to the three CT protocols considered and the results were, as follows: for head examinations – 61.8 mGy, 1212 mGy.cm and 2.55 mSv, respectively; for chest examinations- 13.1 mGy, 657.5 mGy.cm and 9.21 mSv, respectively; for chest-abdomen-pelvic examinations - 13.9 mGy, 782.5 mGy.cm and 11.73 mSv, respectively. The effective dose for the chest examinations was lower than the corresponding value communicated by the European study group under European Commission. The effective dose for head examinations, was slightly higher than the one communicated by the European Commission study due to differences in the scan length. It needs optimizing the radiation dose delivered to patients via periodical review of scan parameters for a protocol under study.
- 1 January 2020
- Published by ACS Publisher in Journal of Nuclear Technology in Applied Science
- Vol. 8 (1) , 7-14
Assessment of Diagnostic Reference Dose Associated with Computed Tomography Examination
The current study is aimed to estimate the diagnostic reference dose levels (DRLs), the volume computer tomogram dose index (CTDIvol), the CT air kerma-length product (PKL,CT) and the effective dose (E) for head, chest and chest-abdomen-pelvic CT examinations performed on adults in King Abdullah Medical City (KAMC), Saudi Arabia. Demographic parameters (such as age, gender, weight, height) for a sample of 535 computed tomography (CT) patients and physical scan parameters (such as patient tube voltage (kV), reference and effective mill ampere-second (mAs), scan length, number of slices, and pitch factor) were collected from a picture archiving and communication system (PACS). CTDIvol and PKL,CT were studied for different patients weights (40 -60 kg, 60-80 kg, 80-100 kg and 100-120 kg). Mean CTDIvol, PKL,CT and effective dose for a standard weight (70 kg ±10%) was evaluated according to the three CT protocols considered and the results were, as follows: for head examinations – 61.8 mGy, 1212 mGy.cm and 2.55 mSv, respectively; for chest examinations- 13.1 mGy, 657.5 mGy.cm and 9.21 mSv, respectively; for chest-abdomen-pelvic examinations - 13.9 mGy, 782.5 mGy.cm and 11.73 mSv, respectively. The effective dose for the chest examinations was lower than the corresponding value communicated by the European study group under European Commission. The effective dose for head examinations, was slightly higher than the one communicated by the European Commission study due to differences in the scan length. It needs optimizing the radiation dose delivered to patients via periodical review of scan parameters for a protocol under study.
- Open Access
- 1 January 2019
- Published by ACS Publisher in Journal of Nuclear Technology in Applied Science
- Vol. 7 (1) , 1-10
Radiation Protection for Patients Undergoing Diagnostic Pelvic X-ray Examinations
The aim of the current study is to measure the entrance skin dose (ESD) for patients undergoing pelvic diagnostic X-ray examinations in King Faisal Specialist Hospital (KFH), Saudi Arabia, and reduce the scattered x-ray to gonads during the examination. The thermo-luminescence dosimeters (TLDs) are processed for low energy X-ray calibration. Three sets of thermo-luminescence dosimeters LiF (TLD-100) detector were irradiated by using a Xstrahl machine with following operating conditions: 60 cm FSD, 1 mA, irradiation time 1 min., 2 mm HVL(Al) and tube voltage of 80 kV. Each TLD set was irradiated for specific air and the mean value of the air kerma was used for calculation the calibration factor. The (ESD) was assessed for forty patients undergoing pelvic diagnostic X-ray examinations using thermo-luminescence dosimeters (TLDs). The patients were classified into three groups according to weights from 40-60 kg, 60-80 kg and 80-110 kg respectively. The ESDs associated with AP-pelvic examinations for the classified patients were 2.91 ± 0.25 mGy , 3.92 ± 0.22 mGy and 4.92 ± 0.6 mGy respectively. The results are compared with the reference levels of the European Union, (EU), International Atomic Energy Agency,(IAEA) and United Kingdom) . Another irradiation for TLD-100 chips was performed above and under the surface of the Lawrence Livermore National Laboratory phantom (LLNL, USA), and a scatter dose absorbed by sensitive organ attenuated by a factor of 20.6% due to using a flat contact gonadal shield .
- 1 January 2019
- Published by ACS Publisher in Journal of Nuclear Technology in Applied Science
- Vol. 7 (1) , 1-10
Open AccessRadiation Protection for Patients Undergoing Diagnostic Pelvic X-ray Examinations
The aim of the current study is to measure the entrance skin dose (ESD) for patients undergoing pelvic diagnostic X-ray examinations in King Faisal Specialist Hospital (KFH), Saudi Arabia, and reduce the scattered x-ray to gonads during the examination. The thermo-luminescence dosimeters (TLDs) are processed for low energy X-ray calibration. Three sets of thermo-luminescence dosimeters LiF (TLD-100) detector were irradiated by using a Xstrahl machine with following operating conditions: 60 cm FSD, 1 mA, irradiation time 1 min., 2 mm HVL(Al) and tube voltage of 80 kV. Each TLD set was irradiated for specific air and the mean value of the air kerma was used for calculation the calibration factor. The (ESD) was assessed for forty patients undergoing pelvic diagnostic X-ray examinations using thermo-luminescence dosimeters (TLDs). The patients were classified into three groups according to weights from 40-60 kg, 60-80 kg and 80-110 kg respectively. The ESDs associated with AP-pelvic examinations for the classified patients were 2.91 ± 0.25 mGy , 3.92 ± 0.22 mGy and 4.92 ± 0.6 mGy respectively. The results are compared with the reference levels of the European Union, (EU), International Atomic Energy Agency,(IAEA) and United Kingdom) . Another irradiation for TLD-100 chips was performed above and under the surface of the Lawrence Livermore National Laboratory phantom (LLNL, USA), and a scatter dose absorbed by sensitive organ attenuated by a factor of 20.6% due to using a flat contact gonadal shield .
- Open Access
- 1 January 2015
- Published by Elsevier in Journal of Radiation Research and Applied Sciences
- Vol. 8 (1) , 100-103
Assessment of entrance skin doses for patients undergoing diagnostic X-ray examinations in King Abdullah Medical City, Makkah, KSA
- 1 January 2015
- Published by Elsevier in Journal of Radiation Research and Applied Sciences
- Vol. 8 (1) , 100-103
Open AccessAssessment of entrance skin doses for patients undergoing diagnostic X-ray examinations in King Abdullah Medical City, Makkah, KSA