Mohammad Mehdi Soltani
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Mohammad Mehdi Soltani has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Abbasali Khademi
Department of Endodontics, Dental Research Center, Dental Research Institute, School of Dentistry, Isfahan University of Medical Sciences, Iran
1 shared publication - Mahnaz Sheikhi
Department of Oral and Maxillofacial Radiology, Torabinejad Dental Research Center, School of Dentistry, Isfahan University of Medical Sciences, Isfahan Po. Code: 8174673461, Iran
1 shared publication - Masoud Saatchi
Department of Endodontics, Dental Research Institute, School of Dentistry, Isfahan University of Medical Sciences, Isfahan, Iran
1 shared publication - Samane Moradi
Department of Endodontics, School of Dentistry, Qom University of Medical Sciences, Qom Po. Code: 3716993456, Iran
1 shared publication
Latest Publications
- Open Access
In Vitro Diagnostic Accuracy and Agreement of Dental Microscope and Cone-Beam Computed Tomography in Comparison with Microcomputed Tomography for Detection of the Second Mesiobuccal Canal of Maxillary First Molars
Objectives. The percentage of failure of endodontically treated maxillary molars is relatively high; one main reason is that the second mesiobuccal canal (MB2) is missing. Some techniques have been proposed for detection of the MB2. This study was aimed at assessing the diagnostic accuracy and agreement of the dental microscope and cone-beam computed tomography (CBCT) in comparison with microcomputed tomography (micro-CT) for detection of the MB2 of maxillary first molars in vitro. Materials and Methods. This in vitro, experimental study evaluated 71 permanent maxillary first molars that were stored in 100% humidity at room temperature. The teeth were mounted in 9 silicone dental arches to the level of their cementoenamel junction (8 teeth in each arch). The blocks underwent CBCT in a XG3D scanner. Access cavity was then prepared, and the teeth were inspected by a surgical microscope for negotiation of the MB2. Also, micro-CT images were obtained from the teeth to serve as the gold standard. CBCT and micro-CT images were observed by two examiners twice with a 2-week interval. Results. The frequency of the MB2 detected by dental microscope was significantly lower than micro-CT ( ) and CBCT ( ); no significant difference existed between micro-CT and CBCT in this respect. The sensitivity, specificity, positive predictive value, and negative predictive value of CBCT for detection of MB2 were 92.6%, 100%, 100%, and 81%, respectively. Conclusion. CBCT is superior to the dental microscope for detection of the MB2 of maxillary first molars and can be used for this purpose in the clinical setting with adequate accuracy.
Open AccessIn Vitro Diagnostic Accuracy and Agreement of Dental Microscope and Cone-Beam Computed Tomography in Comparison with Microcomputed Tomography for Detection of the Second Mesiobuccal Canal of Maxillary First Molars
Objectives. The percentage of failure of endodontically treated maxillary molars is relatively high; one main reason is that the second mesiobuccal canal (MB2) is missing. Some techniques have been proposed for detection of the MB2. This study was aimed at assessing the diagnostic accuracy and agreement of the dental microscope and cone-beam computed tomography (CBCT) in comparison with microcomputed tomography (micro-CT) for detection of the MB2 of maxillary first molars in vitro. Materials and Methods. This in vitro, experimental study evaluated 71 permanent maxillary first molars that were stored in 100% humidity at room temperature. The teeth were mounted in 9 silicone dental arches to the level of their cementoenamel junction (8 teeth in each arch). The blocks underwent CBCT in a XG3D scanner. Access cavity was then prepared, and the teeth were inspected by a surgical microscope for negotiation of the MB2. Also, micro-CT images were obtained from the teeth to serve as the gold standard. CBCT and micro-CT images were observed by two examiners twice with a 2-week interval. Results. The frequency of the MB2 detected by dental microscope was significantly lower than micro-CT ( ) and CBCT ( ); no significant difference existed between micro-CT and CBCT in this respect. The sensitivity, specificity, positive predictive value, and negative predictive value of CBCT for detection of MB2 were 92.6%, 100%, 100%, and 81%, respectively. Conclusion. CBCT is superior to the dental microscope for detection of the MB2 of maxillary first molars and can be used for this purpose in the clinical setting with adequate accuracy.