Jia Liu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jia Liu has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Jie Ren
Department of Medical Ultrasound, Laboratory of Novel Optoacoustic (Ultrasonic) Imaging, The Third Affiliated Hospital of Sun Yat-sen University, Guangzhou 510630, China
1 shared publication - Jin-Xiu Ju
Department of Ultrasound Guangdong Key Laboratory of Liver Disease Research Third Affiliated Hospital of Sun Yat‐Sen University Guangzhou China
1 shared publication - Kai Li
Department of Ultrasound, Guangdong Key Laboratory of Liver Disease Research, The Third Affiliated Hospital of Sun Yat-sen University, Guangzhou, China
1 shared publication - Lu Li
Department of Ultrasound, The Second Affiliated Hospital of Kunming Medical University, Kunming Medical University, Kunming, People’s Republic of China
1 shared publication - Qingjing Zeng
Guangdong Key Laboratory of Liver Disease Research, Department of Ultrasound, The Third Affiliated Hospital of Sun Yat-Sen University, Guangzhou, People’s Republic of China
1 shared publication - Rongqin Zheng
The Third Affiliated Hospital of Sun Yat-sen University, Guangzhou, China
1 shared publication
Latest Publications
- 21 August 2025
- Published by Wiley in The International Journal of Medical Robotics and Computer Assisted Surgery
- Vol. 21 (4) , e70099
Quality and Safety Assessments of 5G‐Powered Telerobotic Ultrasound System for Multi‐Organ Screening: A Prospective Pilot Study
Purpose: This study aims to assess the ability of a 5G‐based telerobotic system to generate required images of diagnostic quality in multi‐organ US examinations.Materials and Methods: This prospective study involved participants in Shenzhen and Tibet, which are 106 and 4000 km, respectively, from the tele‐radiologist's hospital. Participants underwent telerobotic US examinations from September 2020 to March 2021. A total of 127 participants were enrolled. The required image quality was evaluated by the required image adequacy, image quality, the observer reliability and the consistency of the conventional US. The safety assessments were assessed by complications and questionnaires.Results: A total of 1790/2032 (88.1%) required images were considered adequate, and 167/2032 (8.2%) were considered adequate with some reservations. The mean image quality score was 2.83 ± 0.47 on a three‐point Likert scale and did not differ between the districts or sexes. Telerobotic US detected 15 out of 18 abnormalities (83.3%) in 10 patients who underwent both telerobotic US and conventional US. There was good consistency between the two methods (k = 0.7–1.0). Furthermore, nearly 86.0% of patients accepted and would be willing to undergo another telerobotic US examination in the future. Teleradiologists accepted almost all US examinations as adequate for diagnosis and were satisfied with them.Conclusions: The 5G‐based telerobotic US(MGIUS‐R3) can acquire required images with adequacy and quality in multiple organ examination procedures, with high safety and customer satisfaction in this limited group of patients. Further studies with larger samples and more centres are needed to validate this potential new technology.
- 21 August 2025
- Published by Wiley in The International Journal of Medical Robotics and Computer Assisted Surgery
- Vol. 21 (4) , e70099
Quality and Safety Assessments of 5G‐Powered Telerobotic Ultrasound System for Multi‐Organ Screening: A Prospective Pilot Study
Purpose: This study aims to assess the ability of a 5G‐based telerobotic system to generate required images of diagnostic quality in multi‐organ US examinations.Materials and Methods: This prospective study involved participants in Shenzhen and Tibet, which are 106 and 4000 km, respectively, from the tele‐radiologist's hospital. Participants underwent telerobotic US examinations from September 2020 to March 2021. A total of 127 participants were enrolled. The required image quality was evaluated by the required image adequacy, image quality, the observer reliability and the consistency of the conventional US. The safety assessments were assessed by complications and questionnaires.Results: A total of 1790/2032 (88.1%) required images were considered adequate, and 167/2032 (8.2%) were considered adequate with some reservations. The mean image quality score was 2.83 ± 0.47 on a three‐point Likert scale and did not differ between the districts or sexes. Telerobotic US detected 15 out of 18 abnormalities (83.3%) in 10 patients who underwent both telerobotic US and conventional US. There was good consistency between the two methods (k = 0.7–1.0). Furthermore, nearly 86.0% of patients accepted and would be willing to undergo another telerobotic US examination in the future. Teleradiologists accepted almost all US examinations as adequate for diagnosis and were satisfied with them.Conclusions: The 5G‐based telerobotic US(MGIUS‐R3) can acquire required images with adequacy and quality in multiple organ examination procedures, with high safety and customer satisfaction in this limited group of patients. Further studies with larger samples and more centres are needed to validate this potential new technology.
- 19 September 2022
- Published by Springer Nature in Abdominal Radiology
- Vol. 47 (12) , 4245-4253
Prevention of major biliary complications by fusion imaging for thermal ablation of malignant liver tumors adjacent to the bile ducts: a preliminary comparative study
Purpose Ultrasound (US)-guided thermal ablation (TA) may cause major biliary complications, particularly in patients with malignant liver tumors (MLTs) adjacent to the bile ducts. Fusion imaging (FI), is postulated to reduce complication rate; however, there is a lack of clinical data to support this theory. Thus, the aim of our study was to evaluate the safety and efficacy of FI for TA of MLTs proximal to the bile ducts. Methods A retrospective single-center review was conducted on a total of 289 patients with 316 MLTs adjacent to the bile ducts. The patients were divided into two groups based on whether FI was used in the ablation procedures. The choice of the FI-assisted procedure always depends on different operation periods and whether registrations will succeed. The baseline demographics and outcomes of these patients were compared. The efficacy was determined at the 1-month follow-up using contrast-enhanced computed tomography/magnetic resonance. Biliary complications and local tumor progression were subsequently followed-up every 3–6 months. The last follow-up visit was before August 30, 2019. Results Among the included tumors, the incidence rate of major biliary complications after ablation in the FI group was 1.6%, which was significantly lower than that in the non-FI group (7.9%, p = 0.005). There was no significant difference in the efficacy rates of the techniques [99.5% (185/186) versus 98.4% (123/125), p = 0.56] or local progression rates [3.8% (7/185) versus 5.7% (7/123), p = 0.61] between the FI and non-FI groups. Conclusion FI for US-guided TA could be a noninvasive means to decrease major biliary complications. Trial registration number and date of registration: retrospectively registered. Graphical abstract
- 19 September 2022
- Published by Springer Nature in Abdominal Radiology
- Vol. 47 (12) , 4245-4253
Prevention of major biliary complications by fusion imaging for thermal ablation of malignant liver tumors adjacent to the bile ducts: a preliminary comparative study
Purpose Ultrasound (US)-guided thermal ablation (TA) may cause major biliary complications, particularly in patients with malignant liver tumors (MLTs) adjacent to the bile ducts. Fusion imaging (FI), is postulated to reduce complication rate; however, there is a lack of clinical data to support this theory. Thus, the aim of our study was to evaluate the safety and efficacy of FI for TA of MLTs proximal to the bile ducts. Methods A retrospective single-center review was conducted on a total of 289 patients with 316 MLTs adjacent to the bile ducts. The patients were divided into two groups based on whether FI was used in the ablation procedures. The choice of the FI-assisted procedure always depends on different operation periods and whether registrations will succeed. The baseline demographics and outcomes of these patients were compared. The efficacy was determined at the 1-month follow-up using contrast-enhanced computed tomography/magnetic resonance. Biliary complications and local tumor progression were subsequently followed-up every 3–6 months. The last follow-up visit was before August 30, 2019. Results Among the included tumors, the incidence rate of major biliary complications after ablation in the FI group was 1.6%, which was significantly lower than that in the non-FI group (7.9%, p = 0.005). There was no significant difference in the efficacy rates of the techniques [99.5% (185/186) versus 98.4% (123/125), p = 0.56] or local progression rates [3.8% (7/185) versus 5.7% (7/123), p = 0.61] between the FI and non-FI groups. Conclusion FI for US-guided TA could be a noninvasive means to decrease major biliary complications. Trial registration number and date of registration: retrospectively registered. Graphical abstract