Elliot M. Greenberg
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Elliot M. Greenberg has a total of 74 co-authors. Here are the top co-authors by number of shared publications:
J. Todd R. Lawrence
Division of Orthopaedics, Children’s Hospital of Philadelphia, Philadelphia, Pennsylvania, USA
5 shared publicationsTheodore J. Ganley
Division of Orthopaedics, Children’s Hospital of Philadelphia, Philadelphia, Pennsylvania, USA
5 shared publications- Alicia Fernandez-Fernandez
Nova Southeastern University
4 shared publications J. Todd Lawrence
Children’s Hospital of Philadelphia Sports Medicine and Performance Center, Philadelphia, Pennsylvania, USA
4 shared publicationsPhilip McClure
Arcadia University, Department of Physical Therapy, Glenside, PA
4 shared publications- Brendan A. Williams
Children’s Hospital of Philadelphia
3 shared publications
Latest Publications
- Open Access
- 9 October 2026
- Published by SAGE Publications in The American Journal of Sports Medicine
- Vol. 54 (13) , 3222-3229
Can Psychological Readiness Predict Successful Return to Sports After Patellar Stabilization Surgery in Adolescent Patients? A Retrospective Cohort Study
Background: While many metrics are used to subjectively assess a patient’s knee function with patellofemoral instability (PFI), psychological readiness to return to sport (RTS) after patellar stabilization surgery is not well established in this population. The Anterior Cruciate Ligament Return to Sport After Injury (ACL-RSI) scale assesses psychological readiness to RTS after anterior cruciate ligament reconstruction and may be similarly beneficial in understanding this domain in those with PFI. Hypothesis: Higher ACL-RSI scores in patients with PFI are associated with an increased likelihood of RTS after patellar stabilization surgery. Study Design: Cohort study; Level of evidence, 3. Methods: A retrospective review was conducted of adolescent patients (10-19 years old) treated surgically for PFI (medial patellofemoral ligament reconstruction [MPFLR] with or without tibial tubercle osteotomy) at a single institution from January 2020 to October 2024. Patients actively participating in sports at their first orthopaedic visit who completed the ACL-RSI during postoperative rehabilitation were included. Patient demographics, injury characteristics, surgical procedure, ACL-RSI scores, and RTS status were recorded. Descriptive statistics and bivariate analysis were performed. Based on the euclidean distance, the optimal ACL-RSI cutoff score for predicting successful RTS was determined, and diagnostic accuracy was evaluated with a receiver operating curve. A multivariate logistic regression, adjusted for sex, was used to identify predictors of RTS. Results: Study criteria identified 97 patients with a median (IQR) age of 15.6 years (14.2-16.4). Seventy underwent isolated MPFLR and 27 underwent MPFLR with tibial tubercle osteotomy. Successful RTS was achieved in 78.3% (n = 76). RTS was associated with higher ACL-RSI scores ( P = .012), isolated MPFLR ( P = .011), and male sex ( P = .03). An ACL-RSI score ≥59.2 was identified as being indicative of successful RTS (area under the curve, 0.70; 95% CI, 0.56-0.83). While procedure type and ACL-RSI scores were both associated with RTS in univariate analysis, the multivariable analysis adjusting for sex revealed that the ACL-RSI cutoff remained the only significant predictor of RTS (odds ratio, 3.56; 95% CI, 1.10-11.51; P = .033). Conclusion: ACL-RSI scores ≥59.2 are associated with an increased likelihood of successful RTS after surgical treatment for PFI in adolescents. Patient demographics and the studied injury characteristics do not appear to influence the likelihood of successful RTS.
- 9 October 2026
- Published by SAGE Publications in The American Journal of Sports Medicine
- Vol. 54 (13) , 3222-3229
Open AccessCan Psychological Readiness Predict Successful Return to Sports After Patellar Stabilization Surgery in Adolescent Patients? A Retrospective Cohort Study
Background: While many metrics are used to subjectively assess a patient’s knee function with patellofemoral instability (PFI), psychological readiness to return to sport (RTS) after patellar stabilization surgery is not well established in this population. The Anterior Cruciate Ligament Return to Sport After Injury (ACL-RSI) scale assesses psychological readiness to RTS after anterior cruciate ligament reconstruction and may be similarly beneficial in understanding this domain in those with PFI. Hypothesis: Higher ACL-RSI scores in patients with PFI are associated with an increased likelihood of RTS after patellar stabilization surgery. Study Design: Cohort study; Level of evidence, 3. Methods: A retrospective review was conducted of adolescent patients (10-19 years old) treated surgically for PFI (medial patellofemoral ligament reconstruction [MPFLR] with or without tibial tubercle osteotomy) at a single institution from January 2020 to October 2024. Patients actively participating in sports at their first orthopaedic visit who completed the ACL-RSI during postoperative rehabilitation were included. Patient demographics, injury characteristics, surgical procedure, ACL-RSI scores, and RTS status were recorded. Descriptive statistics and bivariate analysis were performed. Based on the euclidean distance, the optimal ACL-RSI cutoff score for predicting successful RTS was determined, and diagnostic accuracy was evaluated with a receiver operating curve. A multivariate logistic regression, adjusted for sex, was used to identify predictors of RTS. Results: Study criteria identified 97 patients with a median (IQR) age of 15.6 years (14.2-16.4). Seventy underwent isolated MPFLR and 27 underwent MPFLR with tibial tubercle osteotomy. Successful RTS was achieved in 78.3% (n = 76). RTS was associated with higher ACL-RSI scores ( P = .012), isolated MPFLR ( P = .011), and male sex ( P = .03). An ACL-RSI score ≥59.2 was identified as being indicative of successful RTS (area under the curve, 0.70; 95% CI, 0.56-0.83). While procedure type and ACL-RSI scores were both associated with RTS in univariate analysis, the multivariable analysis adjusting for sex revealed that the ACL-RSI cutoff remained the only significant predictor of RTS (odds ratio, 3.56; 95% CI, 1.10-11.51; P = .033). Conclusion: ACL-RSI scores ≥59.2 are associated with an increased likelihood of successful RTS after surgical treatment for PFI in adolescents. Patient demographics and the studied injury characteristics do not appear to influence the likelihood of successful RTS.
- Open Access
- 1 October 2026
- Published by International Journal of Sports Physical Therapy in International Journal of Sports Physical Therapy
- Vol. 21 (10)
Strength Testing in the High School-Aged Baseball Athlete: Reliability, Percentage Ratios, and Pain with Throwing
Background: Digital handheld dynamometry (HHD) is widely used to measure strength. However, among youth baseball athletes, it shows inconsistencies in isometric strength measurements, determination of within-limb strength percentage ratios (SPRs), and tracking changes in strength across a season. Purpose: To establish intra-tester reliability of isometric HHD strength testing of shoulder and elbow, describe throwing arm strength trends and SPRs across chronological ages, and report throwing with pain after seasonal participation for high school-aged baseball athletes. Design: Quasi-experimental observational study Methods: Isometric strength for throwing arm musculature was assessed in 34 male high school-aged baseball athletes using an externally fixated HHD and normalized to throwing arm ulnar length. Assessed muscles included (1) shoulder external and internal rotators (ER & IR) in neutral, (2) elbow flexors and extensors at 90˚ shoulder flexion, and (3) shoulder ER and IR at 90˚ abduction. SPRs were calculated for antagonistic groups: shoulder ER/IR and elbow extensors/flexors. Intra-tester reliability was also analyzed. Throwing-related pain was assessed with the Kerlan-Jobe Orthopaedic Clinic Shoulder and Elbow Score (KJOC) after one baseball season. Intra-tester reliability intraclass correlation coefficient (ICC), standard error of measurement (SEM), and minimal detectable change (MDC 95 ) were determined for each testing position. Descriptive trends were reported for strength, SPRs, and KJOC scores. Results: Thirty-four high school-aged male baseball athletes (average age 15.7 ±1.2 years) were recruited for this study, and 30 completed all aspects of the study. Intra tester reliability ICC’s were .822-.902. The SEM was 3.01-6.47 Newton-Meters (Nm), MDC 95 8.34-18.0 Nm. Mean SPR values for these athletes for shoulder ER/IR in neutral was 64.0%, elbow extensors/flexors 70.1%, and shoulder ER/IR at 90° abduction 69.7%. SPRs showed increasing trends with greater chronological age. Post-season KJOC scores revealed no pain with throwing for all subjects. Conclusions: Isometric strength assessment using digital HHD is a reliable method to quantify upper extremity strength in high school-aged baseball athletes. Descriptive SPR trends could aid future research on normative values and analysis of throwing with and without pain. Level of Evidence: Level 3
- 1 October 2026
- Published by International Journal of Sports Physical Therapy in International Journal of Sports Physical Therapy
- Vol. 21 (10)
Open AccessStrength Testing in the High School-Aged Baseball Athlete: Reliability, Percentage Ratios, and Pain with Throwing
Background: Digital handheld dynamometry (HHD) is widely used to measure strength. However, among youth baseball athletes, it shows inconsistencies in isometric strength measurements, determination of within-limb strength percentage ratios (SPRs), and tracking changes in strength across a season. Purpose: To establish intra-tester reliability of isometric HHD strength testing of shoulder and elbow, describe throwing arm strength trends and SPRs across chronological ages, and report throwing with pain after seasonal participation for high school-aged baseball athletes. Design: Quasi-experimental observational study Methods: Isometric strength for throwing arm musculature was assessed in 34 male high school-aged baseball athletes using an externally fixated HHD and normalized to throwing arm ulnar length. Assessed muscles included (1) shoulder external and internal rotators (ER & IR) in neutral, (2) elbow flexors and extensors at 90˚ shoulder flexion, and (3) shoulder ER and IR at 90˚ abduction. SPRs were calculated for antagonistic groups: shoulder ER/IR and elbow extensors/flexors. Intra-tester reliability was also analyzed. Throwing-related pain was assessed with the Kerlan-Jobe Orthopaedic Clinic Shoulder and Elbow Score (KJOC) after one baseball season. Intra-tester reliability intraclass correlation coefficient (ICC), standard error of measurement (SEM), and minimal detectable change (MDC 95 ) were determined for each testing position. Descriptive trends were reported for strength, SPRs, and KJOC scores. Results: Thirty-four high school-aged male baseball athletes (average age 15.7 ±1.2 years) were recruited for this study, and 30 completed all aspects of the study. Intra tester reliability ICC’s were .822-.902. The SEM was 3.01-6.47 Newton-Meters (Nm), MDC 95 8.34-18.0 Nm. Mean SPR values for these athletes for shoulder ER/IR in neutral was 64.0%, elbow extensors/flexors 70.1%, and shoulder ER/IR at 90° abduction 69.7%. SPRs showed increasing trends with greater chronological age. Post-season KJOC scores revealed no pain with throwing for all subjects. Conclusions: Isometric strength assessment using digital HHD is a reliable method to quantify upper extremity strength in high school-aged baseball athletes. Descriptive SPR trends could aid future research on normative values and analysis of throwing with and without pain. Level of Evidence: Level 3
- Open Access
- 1 September 2026
- Published by SAGE Publications in Orthopaedic Journal of Sports Medicine
- Vol. 14 (9)
Dynamic Ultrasound Assessment of Axial Extensor Mechanism Alignment in Adolescents With and Without Patellofemoral Instability
Background: Patellofemoral instability (PFI) is common among adolescents. Dynamic evaluation of extensor mechanism alignment during early knee flexion may improve the understanding of recurrent instability risk. Purpose: To evaluate the use of point of care ultrasound (POCUS) to dynamically measure axial extensor mechanism alignment in patients with and without PFI. Study Design: Cohort study (diagnosis); Level of evidence, 3. Methods: Patients diagnosed with either patellar subluxation or dislocation and aged between 10 and 18 years were eligible. Control participants included those without any knee pain, nor any history of PFI, fracture, or musculoskeletal developmental disorder. Axial extensor mechanism was visualized with POCUS and the distance between the midpoint of the patellar tendon and lateral trochlear ridge (MPT-LTR) and lateral edge of the patellar tendon and LTR (LPT-LTR) was measured under 4 conditions: (1) active knee hyperextension (ie, quadriceps set), (2) full passive extension, (3) 15° of knee flexion, and (4) 30° of knee flexion. Univariate statistical analyses compared MPT-LTR and LPT-LTR distances across cohorts and knee positions. The area under the curve (AUC) evaluated measurement performance. Results: The cohort (PFI; n = 19) and controls (n = 19) were similar with respect to age, height, and weight ( P > .05). In both groups, the MPT-LTR and LPT-LTR were greatest in active hyperextension and progressively medialized with increasing knee flexion. Patients with PFI demonstrated statistically significantly more lateral MPT-LTR and LPT-LTR distance in all testing conditions ( P ≤ .01) when compared with controls. AUC analysis demonstrated acceptable performance across measures, ranging from 0.712 to 0.837. Conclusion: Patients with PFI consistently exhibited a more laterally oriented patella while performing active knee hyperextension and throughout the first 30° of knee flexion when measured using a novel POCUS evaluation.
- 1 September 2026
- Published by SAGE Publications in Orthopaedic Journal of Sports Medicine
- Vol. 14 (9)
Open AccessDynamic Ultrasound Assessment of Axial Extensor Mechanism Alignment in Adolescents With and Without Patellofemoral Instability
Background: Patellofemoral instability (PFI) is common among adolescents. Dynamic evaluation of extensor mechanism alignment during early knee flexion may improve the understanding of recurrent instability risk. Purpose: To evaluate the use of point of care ultrasound (POCUS) to dynamically measure axial extensor mechanism alignment in patients with and without PFI. Study Design: Cohort study (diagnosis); Level of evidence, 3. Methods: Patients diagnosed with either patellar subluxation or dislocation and aged between 10 and 18 years were eligible. Control participants included those without any knee pain, nor any history of PFI, fracture, or musculoskeletal developmental disorder. Axial extensor mechanism was visualized with POCUS and the distance between the midpoint of the patellar tendon and lateral trochlear ridge (MPT-LTR) and lateral edge of the patellar tendon and LTR (LPT-LTR) was measured under 4 conditions: (1) active knee hyperextension (ie, quadriceps set), (2) full passive extension, (3) 15° of knee flexion, and (4) 30° of knee flexion. Univariate statistical analyses compared MPT-LTR and LPT-LTR distances across cohorts and knee positions. The area under the curve (AUC) evaluated measurement performance. Results: The cohort (PFI; n = 19) and controls (n = 19) were similar with respect to age, height, and weight ( P > .05). In both groups, the MPT-LTR and LPT-LTR were greatest in active hyperextension and progressively medialized with increasing knee flexion. Patients with PFI demonstrated statistically significantly more lateral MPT-LTR and LPT-LTR distance in all testing conditions ( P ≤ .01) when compared with controls. AUC analysis demonstrated acceptable performance across measures, ranging from 0.712 to 0.837. Conclusion: Patients with PFI consistently exhibited a more laterally oriented patella while performing active knee hyperextension and throughout the first 30° of knee flexion when measured using a novel POCUS evaluation.
- Open Access
- 1 December 2025
- Published by International Journal of Sports Physical Therapy in International Journal of Sports Physical Therapy
- Vol. 20 (12) , 1675-1683
Agreement of Clinical Grade and Laboratory Grade Force Plates for Countermovement Jump Metrics in Youth Athletes
Background: Recent technological advances have led to the development of user-friendly force plate systems that provide clinicians with the ability to analyze movement with precision that was previously only available within a biomechanics laboratory. While this development is promising, there is limited evidence supporting the concurrent validity of the range of variables provided by these devices, making it difficult for clinicians to interpret how values obtained within a clinical environment compare to published research. Purpose: To compare the concurrent validity of specific performance metrics obtained during a countermovement (CMJ) jump between a clinical grade force plate system and a laboratory grade system. Study Design: Laboratory Based Cohort Study Methods: Sixty youth basketball athletes performed a CMJ jump on a clinical grade and a laboratory grade force plate system. Raw data from each device was utilized to calculate the following measures: jump height, peak ground reaction force (GRF), eccentric rate of force development (RFD), and concentric and eccentric impulse. Wilcoxon signed-rank tests evaluated differences between measures. Spearman correlations and Bland-Altman plots analyzed the relationship and accuracy between devices across all measures. Results: There were no statistically significant differences and good agreement between devices for jump height, peak GRF, and eccentric RFD (p>0.05, percent difference range -3.35% to 6.14%). Other measures of jump performance, including concentric RFD measures, eccentric impulse, and concentric impulse, were moderately to poorly correlated (R-value range 0.296-0.447) and significantly different ( p <0.05) between devices. Conclusion: Measurements between the clinical grade and laboratory grade force plates for jump height, peak ground reaction force, and eccentric RFD were comparable and showed good agreement. Clinicians should exercise caution when comparing data related to impulse measures between these systems. Level of Evidence: 3
- 1 December 2025
- Published by International Journal of Sports Physical Therapy in International Journal of Sports Physical Therapy
- Vol. 20 (12) , 1675-1683
Open AccessAgreement of Clinical Grade and Laboratory Grade Force Plates for Countermovement Jump Metrics in Youth Athletes
Background: Recent technological advances have led to the development of user-friendly force plate systems that provide clinicians with the ability to analyze movement with precision that was previously only available within a biomechanics laboratory. While this development is promising, there is limited evidence supporting the concurrent validity of the range of variables provided by these devices, making it difficult for clinicians to interpret how values obtained within a clinical environment compare to published research. Purpose: To compare the concurrent validity of specific performance metrics obtained during a countermovement (CMJ) jump between a clinical grade force plate system and a laboratory grade system. Study Design: Laboratory Based Cohort Study Methods: Sixty youth basketball athletes performed a CMJ jump on a clinical grade and a laboratory grade force plate system. Raw data from each device was utilized to calculate the following measures: jump height, peak ground reaction force (GRF), eccentric rate of force development (RFD), and concentric and eccentric impulse. Wilcoxon signed-rank tests evaluated differences between measures. Spearman correlations and Bland-Altman plots analyzed the relationship and accuracy between devices across all measures. Results: There were no statistically significant differences and good agreement between devices for jump height, peak GRF, and eccentric RFD (p>0.05, percent difference range -3.35% to 6.14%). Other measures of jump performance, including concentric RFD measures, eccentric impulse, and concentric impulse, were moderately to poorly correlated (R-value range 0.296-0.447) and significantly different ( p <0.05) between devices. Conclusion: Measurements between the clinical grade and laboratory grade force plates for jump height, peak ground reaction force, and eccentric RFD were comparable and showed good agreement. Clinicians should exercise caution when comparing data related to impulse measures between these systems. Level of Evidence: 3
- Open Access
- 11 April 2025
- Published by SAGE Publications in Orthopaedic Journal of Sports Medicine
- Vol. 13 (4)
Precision Rehabilitation After Youth Anterior Cruciate Ligament Reconstruction: Individualized Reinjury Risk Stratification and Modifiable Risk Factor Identification to Guide Late-Phase Rehabilitation
Background: After anterior cruciate ligament (ACL) reconstruction, adolescent athletes have a high risk of second ACL injuries, and revision ACL reconstruction is associated with increased medical costs, reduced activity levels, chronic knee pain, and higher rates of knee osteoarthritis, making the prevention of a reinjury a priority. While athlete clearance protocols and algorithms exist, the current methods of identifying the reinjury risk have limited predictive accuracy and are largely based on nonmodifiable risk factors, which limit their clinical application. Purpose: The goal of this study was to develop an ACL reinjury risk prediction (ACL-RRP) model capable of accurately classifying an individual patient’s risk, identifying modifiable risk factors, and ranking these factors in the order of importance and ability to be modified. Study Design: Cohort study (Diagnosis); Level of evidence, 2. Methods: A clinician-informed approach was utilized to develop the prediction model and an interpretable output system. The primary outcome variable was the likelihood of sustaining a repeat ACL injury. The data were split into training (80% [n = 628]) and holdout (20% [n = 158]) datasets to train and subsequently validate the model. The accuracy of classification was identified by the sensitivity, specificity, positive/negative predictive values, and odds ratio. Results: The final model included 33 predictor variables, 23 of which are modifiable. The model adjusted the weight of the risk classification and risk factors (predictor variables) on a case-by-case basis. The model demonstrated a sensitivity of 94% and a specificity of 76%. Patients classified as being high risk had 4.5 times the risk of repeat ACL injuries compared with those classified as being low risk. Conclusion: This clinician-informed ACL-RRP model demonstrated a high degree of accuracy when classifying patients as having a high or low risk of repeat ACL injuries and generated patient-specific modifiable risk factors to guide ongoing rehabilitation or patient education to achieve the goals of reducing the ACL reinjury risk.
- 11 April 2025
- Published by SAGE Publications in Orthopaedic Journal of Sports Medicine
- Vol. 13 (4)
Open AccessPrecision Rehabilitation After Youth Anterior Cruciate Ligament Reconstruction: Individualized Reinjury Risk Stratification and Modifiable Risk Factor Identification to Guide Late-Phase Rehabilitation
Background: After anterior cruciate ligament (ACL) reconstruction, adolescent athletes have a high risk of second ACL injuries, and revision ACL reconstruction is associated with increased medical costs, reduced activity levels, chronic knee pain, and higher rates of knee osteoarthritis, making the prevention of a reinjury a priority. While athlete clearance protocols and algorithms exist, the current methods of identifying the reinjury risk have limited predictive accuracy and are largely based on nonmodifiable risk factors, which limit their clinical application. Purpose: The goal of this study was to develop an ACL reinjury risk prediction (ACL-RRP) model capable of accurately classifying an individual patient’s risk, identifying modifiable risk factors, and ranking these factors in the order of importance and ability to be modified. Study Design: Cohort study (Diagnosis); Level of evidence, 2. Methods: A clinician-informed approach was utilized to develop the prediction model and an interpretable output system. The primary outcome variable was the likelihood of sustaining a repeat ACL injury. The data were split into training (80% [n = 628]) and holdout (20% [n = 158]) datasets to train and subsequently validate the model. The accuracy of classification was identified by the sensitivity, specificity, positive/negative predictive values, and odds ratio. Results: The final model included 33 predictor variables, 23 of which are modifiable. The model adjusted the weight of the risk classification and risk factors (predictor variables) on a case-by-case basis. The model demonstrated a sensitivity of 94% and a specificity of 76%. Patients classified as being high risk had 4.5 times the risk of repeat ACL injuries compared with those classified as being low risk. Conclusion: This clinician-informed ACL-RRP model demonstrated a high degree of accuracy when classifying patients as having a high or low risk of repeat ACL injuries and generated patient-specific modifiable risk factors to guide ongoing rehabilitation or patient education to achieve the goals of reducing the ACL reinjury risk.
- 2 April 2025
- Published by SAGE Publications in Sports Health: A Multidisciplinary Approach
- Vol. 17 (6) , 1225-1230
Evaluation of the PhySens as a Wrist-Worn Wearable in Pitch Detection and Biomechanical Workload Estimation
Background: The volume and frequency of throwing activity are among the most significant risk factors for developing overuse injuries in youth athletes. Despite introducing systematic guidelines for ‘pitch counts,’ throwing injuries continue to rise. Using technology to create enhanced measures of workload exposure in this unique population of athletes may help generate more effective and personalized injury prevention strategies. Hypothesis: The wrist-worn sensor system (PhySens) will: 1) accurately detect and differentiate throwing activity from other baseball movements, and 2) accurately predict ball velocity, arm slot angle, and elbow valgus torque. Study Design: Descriptive laboratory study. Level of Evidence: Level 5. Methods: Youth pitchers (n = 10) performed a standardized protocol of pitching, field-throwing, and batting. Pitching velocity and biomechanical data were simultaneously captured by the PhySens and traditional 3-dimensional motion capture. The accuracy of the pitching detection algorithm (throw vs batting) was analyzed by comparing truth data with throwing events cataloged by the device. Ball velocity, elbow valgus torque, and arm slot angle predictions were assessed with Pearson correlation coefficients and Bland-Altman plots. Results: A total of 230 events (pitches and bat swings) were analyzed. Pitch detection was excellent, with a sensitivity of 99.4% and specificity 97.9%. Pearson correlations were significant and excellent across all predicted variables, with ball velocity r = 0.96, elbow valgus torque r = 0.95, and arm slot angle r = 0.87. The system demonstrated excellent estimations of ball velocity, elbow valgus torque, and arm slot angle. Conclusion: This novel single-sensor wrist worn device was highly accurate in detecting pitching events, predicting ball velocity, and estimating arm slot angle and elbow valgus torque. Clinical Relevance: Throwing volume is highly associated with overuse injuries in youth baseball players. Sensor-based measures of workload monitoring can address inherent limitations related to human error and underestimation of true throwing exposure.
- 2 April 2025
- Published by SAGE Publications in Sports Health: A Multidisciplinary Approach
- Vol. 17 (6) , 1225-1230
Evaluation of the PhySens as a Wrist-Worn Wearable in Pitch Detection and Biomechanical Workload Estimation
Background: The volume and frequency of throwing activity are among the most significant risk factors for developing overuse injuries in youth athletes. Despite introducing systematic guidelines for ‘pitch counts,’ throwing injuries continue to rise. Using technology to create enhanced measures of workload exposure in this unique population of athletes may help generate more effective and personalized injury prevention strategies. Hypothesis: The wrist-worn sensor system (PhySens) will: 1) accurately detect and differentiate throwing activity from other baseball movements, and 2) accurately predict ball velocity, arm slot angle, and elbow valgus torque. Study Design: Descriptive laboratory study. Level of Evidence: Level 5. Methods: Youth pitchers (n = 10) performed a standardized protocol of pitching, field-throwing, and batting. Pitching velocity and biomechanical data were simultaneously captured by the PhySens and traditional 3-dimensional motion capture. The accuracy of the pitching detection algorithm (throw vs batting) was analyzed by comparing truth data with throwing events cataloged by the device. Ball velocity, elbow valgus torque, and arm slot angle predictions were assessed with Pearson correlation coefficients and Bland-Altman plots. Results: A total of 230 events (pitches and bat swings) were analyzed. Pitch detection was excellent, with a sensitivity of 99.4% and specificity 97.9%. Pearson correlations were significant and excellent across all predicted variables, with ball velocity r = 0.96, elbow valgus torque r = 0.95, and arm slot angle r = 0.87. The system demonstrated excellent estimations of ball velocity, elbow valgus torque, and arm slot angle. Conclusion: This novel single-sensor wrist worn device was highly accurate in detecting pitching events, predicting ball velocity, and estimating arm slot angle and elbow valgus torque. Clinical Relevance: Throwing volume is highly associated with overuse injuries in youth baseball players. Sensor-based measures of workload monitoring can address inherent limitations related to human error and underestimation of true throwing exposure.
- 16 January 2025
- Published by Elsevier in Physical Therapy in Sport
- Vol. 72, 25-31
The influence of patient gender on exercise prescription in ACL reconstruction rehabilitation
- 16 January 2025
- Published by Elsevier in Physical Therapy in Sport
- Vol. 72, 25-31
The influence of patient gender on exercise prescription in ACL reconstruction rehabilitation
- Open Access
- 11 October 2024
- Published by SAGE Publications in Orthopaedic Journal of Sports Medicine
- Vol. 12 (10)
Reliability and Validity of an Ultrasound-Derived Measure for Axial Patellofemoral Alignment
Background: Axial extensor mechanism alignment is routinely assessed in patients with patellofemoral instability.Although many of these assessments are described using magnetic resonance imaging, it is plausible that ultrasound (US) imaging could be utilized to provide similar information in a more cost-effective and time-efficient manner. Purpose: To (1) describe and assess the reliability of a novel measure of extensor mechanism alignment of the patellofemoral joint using musculoskeletal US and (2) establish the construct validity of this measure through comparison of patients with and without patellar instability. Study Design: Cohort study (diagnosis); Level of evidence, 3. Methods: Patients with (n = 24; 14.2 ± 3.1 years; 83% female) and without (n = 26; 14.7 ± 2.8 years; 69% female) a clinical history of patellofemoral instability (PFI) participated. Extensor mechanism alignment was assessed bilaterally on US, measuring the distance between the midpoint of the patellar tendon to the lateral trochlear ridge (MPT-LTR). Interrater reliability of the measurements was assessed using the intraclass correlation coefficient (ICC), with a minimum of 1 week between measurements for test-retest reliability. Differences between limbs were assessed using paired-samples t tests, and between-group differences were compared using independent-samples t tests. Results: Patients with PFI demonstrated a significantly smaller MPT-LTR distance than healthy controls on both their involved (8.1 ± 3.6 vs 12.6 ± 2.6 mm) and uninvolved (8.9 ± 3.4 vs 12.9 ± 2.4 mm) limbs ( P < .001 for both), indicating greater lateralization of the patellar tendon relative to the trochlea. There were no differences found between limbs for either patients with PFI ( P = .26) or controls ( P = .46). Interrater reliability was good (ICC = 0.785; 95% confidence interval [CI], 0.579-0.890), and test-retest reliability (n = 8) was excellent (ICC = 0.958; 95% CI, 0.790-0.992). Conclusion: The US-based MPT-LTR distance demonstrated good-to-excellent reliability. When compared with controls, the MPT-LTR distance was smaller in patients with PFI, indicating greater lateralization of the extensor mechanism.
- 11 October 2024
- Published by SAGE Publications in Orthopaedic Journal of Sports Medicine
- Vol. 12 (10)
Open AccessReliability and Validity of an Ultrasound-Derived Measure for Axial Patellofemoral Alignment
Background: Axial extensor mechanism alignment is routinely assessed in patients with patellofemoral instability.Although many of these assessments are described using magnetic resonance imaging, it is plausible that ultrasound (US) imaging could be utilized to provide similar information in a more cost-effective and time-efficient manner. Purpose: To (1) describe and assess the reliability of a novel measure of extensor mechanism alignment of the patellofemoral joint using musculoskeletal US and (2) establish the construct validity of this measure through comparison of patients with and without patellar instability. Study Design: Cohort study (diagnosis); Level of evidence, 3. Methods: Patients with (n = 24; 14.2 ± 3.1 years; 83% female) and without (n = 26; 14.7 ± 2.8 years; 69% female) a clinical history of patellofemoral instability (PFI) participated. Extensor mechanism alignment was assessed bilaterally on US, measuring the distance between the midpoint of the patellar tendon to the lateral trochlear ridge (MPT-LTR). Interrater reliability of the measurements was assessed using the intraclass correlation coefficient (ICC), with a minimum of 1 week between measurements for test-retest reliability. Differences between limbs were assessed using paired-samples t tests, and between-group differences were compared using independent-samples t tests. Results: Patients with PFI demonstrated a significantly smaller MPT-LTR distance than healthy controls on both their involved (8.1 ± 3.6 vs 12.6 ± 2.6 mm) and uninvolved (8.9 ± 3.4 vs 12.9 ± 2.4 mm) limbs ( P < .001 for both), indicating greater lateralization of the patellar tendon relative to the trochlea. There were no differences found between limbs for either patients with PFI ( P = .26) or controls ( P = .46). Interrater reliability was good (ICC = 0.785; 95% confidence interval [CI], 0.579-0.890), and test-retest reliability (n = 8) was excellent (ICC = 0.958; 95% CI, 0.790-0.992). Conclusion: The US-based MPT-LTR distance demonstrated good-to-excellent reliability. When compared with controls, the MPT-LTR distance was smaller in patients with PFI, indicating greater lateralization of the extensor mechanism.
- Open Access
- 5 October 2024
- Published by Association for Computing Machinery (ACM)
- p. 171-175
Using Decision Tree Classifier to Increase Screening Test Sensitivity for the Prediction of ACL Retear
- 5 October 2024
- Published by Association for Computing Machinery (ACM)
- p. 171-175
Open AccessUsing Decision Tree Classifier to Increase Screening Test Sensitivity for the Prediction of ACL Retear