XGXuyang Ge

Xuyang Ge

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Xuyang Ge has a total of 10 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Design of Suspended Slot Racetrack Microring Refractive Index Sensor Based on Polymer Nanocomposite

    by Xihan Wu, Jiajun Wang, Jiachen Han, Yuqi Xie, Xuyang Ge, Jianzhi Liao, Yunji Yi

    Recently, polymer nanocomposites have attracted great interest due to their remarkable characteristics of high performance and enabling production of low-cost devices. This article explores the reflective index sensing application of the polymer nanocomposite IOC-133, which is a TiOx/polymer nanocomposite with a reflective index between 1.8 and 1.9. Considering the material properties of high reflective index, low absorption loss, and compatibility with nanoimprint lithography, a microring-based reflective index sensor with a suspended slot waveguide structure is proposed. We combined the sensing mechanism of slot waveguides with high reflective index polymer nanocomposites and designed the suspended structure to address the problem of decreasing sensitivity caused by residual layers. The sensing device was adopted as a microring resonator, which is conducive to large-scale integration. The finite-difference time-domain (FDTD) method was employed to analyze the effects of several key parameters. The results showed that the racetrack microring sensor we propose can achieve a high sensitivity of 436 nm/RIU (Refractive Index Units), about six times higher than the microring sensor with a ridge waveguide. The Q factor of the microring reaches 1.42 × 104, and the detection limit is 1.38 × 10−4 RIU. The proposed suspended slot microring sensor has potential value in the field of nanoprinted photonic integrated circuits.


  • Open Access

    Low Power Consumption Hybrid-Integrated Thermo-Optic Switch with Polymer Cladding and Silica Waveguide Core

    by Yuqi Xie, Jiachen Han, Tian Qin, Xuyang Ge, Xihan Wu, Lu Liu, Xubin Wu, Yunji Yi

    Taking advantage of the large thermo-optical coefficient of polymer materials, a hybrid-integrated thermo-optic switch was designed and simulated. It is also compatible with the existing silica-based planar light-wave circuit (PLC) platform. To further reduce the power consumption, we introduced the air trench structure and optimized the structural parameters of the heating region. This scheme is beneficial to solving the problem of the large driving power of silica-based thermo-optic switches at this stage. Compared with the switching power of all-silica devices, the power consumption can be reduced from 116.11 mW (TE) and 114.86 mW (TM) to 5.49 mW (TE) and 5.96 mW (TM), which is close to the driving power of the reported switches adopting polymer material as the core. For the TE mode, the switch’s rise and fall times were 121 µs and 329 µs. For the TM mode, the switch times were simulated to be 118 µs (rise) and 329 µs (fall). This device can be applied to hybrid integration fields such as array switches and reconfigurable add/drop multiplexing (ROADM) technology.


  • Open Access

    Highly Sensitive Liquid M-Z Waveguide Sensor Based on Polymer Suspended Slot Waveguide Structure

    by Jiachen Han, Xihan Wu, Xuyang Ge, Yuqi Xie, Guoming Song, Lu Liu, Yunji Yi

    The slot structure has great advantages in improving the sensitivity of integrated waveguide optical sensors and reducing the detection limit. We propose a polymer Mach–Zehnder interferometer (MZI) optical sensor based on the slot structure and adopted the suspended structure to improve optical field interaction with the analyte, hence boosting the sensor’s sensing accuracy. In this paper, the effects of the single waveguide width, slot width, and coupling structure of the slot waveguide on the performance of the sensor operating at a 1550 nm wavelength were analyzed. Under the premise of satisfying single-mode transmission, we designed an MZI with a branch spacing of 10 µm, arm length of 2045 µm, branch span of 700 µm, and slot region of 500 µm. The sensor’s average sensitivity was 972.1 dB/RIU, and its average detection resolution was 1.6 × 10−6 RIU, which is approximately 1.5 times higher than that of the suspended strip waveguide, 1.6 times higher than that of the non-suspended slot structure, and 2.1 times higher than that of the non-suspended strip waveguide.