Kehao Zhuang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Kehao Zhuang has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
- Huanhai Xin
Zhejiang University
6 shared publications - Linbin Huang
Zhejiang University
4 shared publications - Guang Hu
College of Electrical Engineering, Zhejiang University, Hangzhou, China
2 shared publications Hangyu Chen
College of Electrical Engineering, Zhejiang University, Hangzhou, China
2 shared publications- Pengfei Hu
School of Electrical Engineering, Zhejiang University, Hangzhou 310027, China
2 shared publications - Ruohan Leng
Zhejiang University
2 shared publications
Latest Publications
- Open Access
- 28 June 2026
- Published by Elsevier in Electric Power Systems Research
- Vol. 262
Model-free power system stability enhancement with dissipativity-based neural control
- 28 June 2026
- Published by Elsevier in Electric Power Systems Research
- Vol. 262
Open AccessModel-free power system stability enhancement with dissipativity-based neural control
- 23 June 2026
- Published by Elsevier in Electric Power Systems Research
- Vol. 262
Data-driven grid-forming control for STATCOMs to achieve optimal and adaptive synchronization
- 23 June 2026
- Published by Elsevier in Electric Power Systems Research
- Vol. 262
Data-driven grid-forming control for STATCOMs to achieve optimal and adaptive synchronization
- Open Access
Model-Free Power System Stability Enhancement with Dissipativity-Based Neural Control
The integration of converter-interfaced generation introduces new transient stability challenges to modern power systems. Classical Lyapunov- and scalable passivity-based approaches typically rely on restrictive assumptions, and finding storage functions for large grids is generally considered intractable. Furthermore, most methods require an accurate grid dynamics model. To address these challenges, we propose a model-free, nonlinear, and dissipativity-based controller which, when applied to grid-connected virtual synchronous generators (VSGs), enhances power system transient stability. Using input-state data, we train neural networks to learn dissipativity-characterizing matrices that yield stabilizing controllers. Furthermore, we incorporate cost function shaping to improve the performance with respect to the user-specified objectives. Numerical results on a modified, all-VSG Kundur two-area power system validate the effectiveness of the proposed approach.
Open AccessModel-Free Power System Stability Enhancement with Dissipativity-Based Neural Control
The integration of converter-interfaced generation introduces new transient stability challenges to modern power systems. Classical Lyapunov- and scalable passivity-based approaches typically rely on restrictive assumptions, and finding storage functions for large grids is generally considered intractable. Furthermore, most methods require an accurate grid dynamics model. To address these challenges, we propose a model-free, nonlinear, and dissipativity-based controller which, when applied to grid-connected virtual synchronous generators (VSGs), enhances power system transient stability. Using input-state data, we train neural networks to learn dissipativity-characterizing matrices that yield stabilizing controllers. Furthermore, we incorporate cost function shaping to improve the performance with respect to the user-specified objectives. Numerical results on a modified, all-VSG Kundur two-area power system validate the effectiveness of the proposed approach.
- 13 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Sustainable Energy
- Vol. 17 (2) , 1755-1771
Small-Signal Stability Assessment and Enhancement of Grid-Following/Grid-Forming Hybrid Systems Based on Voltage and Current Strength
With the rapid development of renewable energy, power systems are witnessing an increasing penetration of power converters. Currently, converters widely employ grid-following (GFL) control, while grid-forming (GFM) control is considered as a grid-friendly strategy to accommodate large-scale power converters. Hence, GFL-GFM hybrid systems (GGHSs) will prevail in the future. However, such systems may encounter small-signal stability issues across a wide frequency range due to the closed-loop interactions among the power network, GFL, and GFM converters. To address this problem, this paper first introduces the concept of grid current strength, a metric that quantitatively characterizes the stability of GFM converters, thereby extending the traditional grid voltage strength. We derive low-dimensional GFL and GFM subsystems to represent the dynamics and stability of the original high-dimensional system. On this basis, a two-dimensional strength index is proposed to quantitatively assess the stability margin of the GGHSs in a tractable manner. Based on this index, we analyze the impact of the proportions of GFL and GFM converters on system stability and demonstrate that inappropriate proportions may lead to instability. Finally, we propose a method to rapidly identify the critical GFL or GFM devices that dominate the system stability using participation factors. On this basis, we introduce stability enhancement strategies for GGHSs in both the system planning and system operational stages. The efficacy of the proposed assessment and enhancement methods is validated through time-domain simulations and hardware-in-the-loop (HIL) tests.
- 13 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Sustainable Energy
- Vol. 17 (2) , 1755-1771
Small-Signal Stability Assessment and Enhancement of Grid-Following/Grid-Forming Hybrid Systems Based on Voltage and Current Strength
With the rapid development of renewable energy, power systems are witnessing an increasing penetration of power converters. Currently, converters widely employ grid-following (GFL) control, while grid-forming (GFM) control is considered as a grid-friendly strategy to accommodate large-scale power converters. Hence, GFL-GFM hybrid systems (GGHSs) will prevail in the future. However, such systems may encounter small-signal stability issues across a wide frequency range due to the closed-loop interactions among the power network, GFL, and GFM converters. To address this problem, this paper first introduces the concept of grid current strength, a metric that quantitatively characterizes the stability of GFM converters, thereby extending the traditional grid voltage strength. We derive low-dimensional GFL and GFM subsystems to represent the dynamics and stability of the original high-dimensional system. On this basis, a two-dimensional strength index is proposed to quantitatively assess the stability margin of the GGHSs in a tractable manner. Based on this index, we analyze the impact of the proportions of GFL and GFM converters on system stability and demonstrate that inappropriate proportions may lead to instability. Finally, we propose a method to rapidly identify the critical GFL or GFM devices that dominate the system stability using participation factors. On this basis, we introduce stability enhancement strategies for GGHSs in both the system planning and system operational stages. The efficacy of the proposed assessment and enhancement methods is validated through time-domain simulations and hardware-in-the-loop (HIL) tests.
- 6 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 40 (3) , 2520-2534
Small Signal Synchronization Stability Analysis of Interconnected System Containing Grid-Forming and Grid-Following Converters From the Perspective of Dual-Axis Synchronous Generator
With the integration of large-scale renewable energy sources into the power grid, the interconnection between Grid-Forming (GFM) Voltage Source Converters (VSCs) and Grid-Following (GFL) VSCs has become a prominent trend in the power system. However, significant differences in the synchronization mechanisms between GFM VSCs and GFL VSCs have led to unclear small-signal synchronization stability characteristics in interconnected systems. To address the gap, this paper employs the concept of a synchronous generator that simultaneously controls the dq internal potential components for a better physical understanding, constructing an equivalent structure capable of unifying GFM-VSC and GFL-VSC. Mathematically, a synchronization stability analysis model for interconnected systems based on current sources is established. Furthermore, a quantitative indicator for the small-signal synchronization stability margin in interconnected systems is introduced based on the generalized Nyquist criterion, and a concise analysis is presented regarding the impact of control parameters on small-signal synchronization stability. In addition, an optimization method for GFM-VSCs parameters and configuration based on participation factor iteration is proposed. Finally, simulation examples are built in MATLAB/Simulink to verify the rationality of the theoretical analysis.
- 6 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 40 (3) , 2520-2534
Small Signal Synchronization Stability Analysis of Interconnected System Containing Grid-Forming and Grid-Following Converters From the Perspective of Dual-Axis Synchronous Generator
With the integration of large-scale renewable energy sources into the power grid, the interconnection between Grid-Forming (GFM) Voltage Source Converters (VSCs) and Grid-Following (GFL) VSCs has become a prominent trend in the power system. However, significant differences in the synchronization mechanisms between GFM VSCs and GFL VSCs have led to unclear small-signal synchronization stability characteristics in interconnected systems. To address the gap, this paper employs the concept of a synchronous generator that simultaneously controls the dq internal potential components for a better physical understanding, constructing an equivalent structure capable of unifying GFM-VSC and GFL-VSC. Mathematically, a synchronization stability analysis model for interconnected systems based on current sources is established. Furthermore, a quantitative indicator for the small-signal synchronization stability margin in interconnected systems is introduced based on the generalized Nyquist criterion, and a concise analysis is presented regarding the impact of control parameters on small-signal synchronization stability. In addition, an optimization method for GFM-VSCs parameters and configuration based on participation factor iteration is proposed. Finally, simulation examples are built in MATLAB/Simulink to verify the rationality of the theoretical analysis.
- 10 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 40 (1) , 2355-2370
An Extended Impedance Model for Power Electronics Converters Retaining Explicit Synchronization Dynamics
In power systems with a high penetration of renewable energy, grid-forming and grid-following inverters coexist with synchronous generators. The wide-frequency-band dynamic interactions among various machines result in intricate interactions involving electromagnetic dynamics and synchronous behaviors, posing challenges for stability analysis. Thus, this article proposes an extended impedance model (EIM) that introduces an additional degree of freedom to separate the synchronous dynamics from the electromagnetic dynamics. Input and output variables corresponding to the electromagnetic and synchronous dynamics are independently retained in the proposed EIM. It allows for analyzing specific stability issues by selecting an appropriate dominant loop of concern. Subsequently, a method to identify the dominant loop associated with weakly dampened modes is presented, and an index is introduced to assess the applicability of the derived models. Note that the EIM is obtained without introducing any model redundancy, while it maintains the scalability of impedance models. Using the proposed EIM for stability analysis enables a more extensive and flexible selection of the dominant loops, facilitating the pinpointing of the root cause of instability. The efficacy of the model has been validated through simulations and experimental tests.
- 10 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 40 (1) , 2355-2370
An Extended Impedance Model for Power Electronics Converters Retaining Explicit Synchronization Dynamics
In power systems with a high penetration of renewable energy, grid-forming and grid-following inverters coexist with synchronous generators. The wide-frequency-band dynamic interactions among various machines result in intricate interactions involving electromagnetic dynamics and synchronous behaviors, posing challenges for stability analysis. Thus, this article proposes an extended impedance model (EIM) that introduces an additional degree of freedom to separate the synchronous dynamics from the electromagnetic dynamics. Input and output variables corresponding to the electromagnetic and synchronous dynamics are independently retained in the proposed EIM. It allows for analyzing specific stability issues by selecting an appropriate dominant loop of concern. Subsequently, a method to identify the dominant loop associated with weakly dampened modes is presented, and an index is introduced to assess the applicability of the derived models. Note that the EIM is obtained without introducing any model redundancy, while it maintains the scalability of impedance models. Using the proposed EIM for stability analysis enables a more extensive and flexible selection of the dominant loops, facilitating the pinpointing of the root cause of instability. The efficacy of the model has been validated through simulations and experimental tests.
- 22 September 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 37 (4) , 2790-2802
Current Saturation Analysis and Anti-Windup Control Design of Grid-Forming Voltage Source Converter
Grid-Forming voltage source converter (VSC) connected to grid will occur current saturation (CS) under large disturbance due to its weak over-current ability. At present, some researches have pointed out that CS is more likely to lead to transient instability of VSC, which has been solved to a certain extent. However, there are very few studies on the VSC's recovery after grid fault occurring. In this paper, the phenomenon and reasons that grid-forming VSC encounter CS are explained. In particular, the static limit boundary conditions of VSC under unsaturated mode are given analytically in this paper, and then the conditions for VSC to recover to normal mode after CS are also analyzed. The theory shows that if VSC is saturated, it is difficult to recover to normal mode even if the grid has returned to normal. The saturated VSC working as an abnormal current source cannot output active power according to the control command, which is harmful to the stable operation of power grid. In order to deal with this problem, based on the conditions of VSC recovering from CS to normal mode, an anti-windup stability enhanced control is proposed. Simulations and hardware-in-the-loop experiments verify the validity of the CS analysis and the effectiveness of the proposed control scheme.
- 22 September 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 37 (4) , 2790-2802
Current Saturation Analysis and Anti-Windup Control Design of Grid-Forming Voltage Source Converter
Grid-Forming voltage source converter (VSC) connected to grid will occur current saturation (CS) under large disturbance due to its weak over-current ability. At present, some researches have pointed out that CS is more likely to lead to transient instability of VSC, which has been solved to a certain extent. However, there are very few studies on the VSC's recovery after grid fault occurring. In this paper, the phenomenon and reasons that grid-forming VSC encounter CS are explained. In particular, the static limit boundary conditions of VSC under unsaturated mode are given analytically in this paper, and then the conditions for VSC to recover to normal mode after CS are also analyzed. The theory shows that if VSC is saturated, it is difficult to recover to normal mode even if the grid has returned to normal. The saturated VSC working as an abnormal current source cannot output active power according to the control command, which is harmful to the stable operation of power grid. In order to deal with this problem, based on the conditions of VSC recovering from CS to normal mode, an anti-windup stability enhanced control is proposed. Simulations and hardware-in-the-loop experiments verify the validity of the CS analysis and the effectiveness of the proposed control scheme.
- 21 September 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 37 (3) , 3085-3098
Hybrid SiC-Si DC–AC Topology: SHEPWM Si-IGBT Master Unit Handling High Power Integrated With Partial-Power SiC-MOSFET Slave Unit Improving Performance
Based on partial power conversion concept, this article proposes a hybrid silicon carbide (SiC)-silicon (Si) dc–ac topology to improve performance in high power application. First, master unit (MU) uses Si-IGBT working in low frequency to handle main high power because of its high rated current capacity and high switching loss, whereas the low power quality of MU is induced by the low switching frequency. And SiC-MOSFET suffers from high cost and high conduction loss at high power level. To solve these problems, the partial-power slave unit (SU) based on SiC-MOSFET is connected with MU in series through line-frequency transformer, whereas SU works in high frequency to compensate the harmonic of MU and adjusts the total output voltage. In this new topology, the corresponding hybrid modulation strategy and multiple quasi-proportional-resonance control for single-phase system are introduced in detail to ensure the reliable operation. In the end, a 4.5-kW converter prototype was implemented and tested. Simulation and experiment results are given to verify the performance of the proposed hybrid dc–ac topology.
- 21 September 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 37 (3) , 3085-3098
Hybrid SiC-Si DC–AC Topology: SHEPWM Si-IGBT Master Unit Handling High Power Integrated With Partial-Power SiC-MOSFET Slave Unit Improving Performance
Based on partial power conversion concept, this article proposes a hybrid silicon carbide (SiC)-silicon (Si) dc–ac topology to improve performance in high power application. First, master unit (MU) uses Si-IGBT working in low frequency to handle main high power because of its high rated current capacity and high switching loss, whereas the low power quality of MU is induced by the low switching frequency. And SiC-MOSFET suffers from high cost and high conduction loss at high power level. To solve these problems, the partial-power slave unit (SU) based on SiC-MOSFET is connected with MU in series through line-frequency transformer, whereas SU works in high frequency to compensate the harmonic of MU and adjusts the total output voltage. In this new topology, the corresponding hybrid modulation strategy and multiple quasi-proportional-resonance control for single-phase system are introduced in detail to ensure the reliable operation. In the end, a 4.5-kW converter prototype was implemented and tested. Simulation and experiment results are given to verify the performance of the proposed hybrid dc–ac topology.