Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Valentin Maranges has a total of 9 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Poly(ethylene glycol) Diacrylate Hydrogel with Silver Nanoclusters for Water Pb(II) Ions Filtering

    by Luca Burratti, Marco Zannotti, Valentin Maranges, Rita Giovannetti, Leonardo Duranti, Fabio De Matteis, Roberto Francini, Paolo Prosposito

    Poly(ethylene glycol) diacrylate (PEGDA) hydrogels modified with luminescent silver nanoclusters (AgNCs) are synthesized by a photo-crosslinking process. The hybrid material thus obtained is employed to filter Pb(II) polluted water. Under the best conditions, the nanocomposite is able to remove up to 80–90% of lead contaminant, depending on the filter composition. The experimental results indicate that the adsorption process of Pb(II) onto the modified filter can be well modeled using the Freundlich isotherm, thus revealing that the chemisorption is the driving process of Pb(II) adsorption. In addition, the parameter n in the Freundlich model suggests that the adsorption process of Pb(II) ions in the modified hydrogel is favored. Based on the obtained remarkable contaminant uptake capacity and the overall low cost, this hybrid system appears to be a promising sorbent material for the removal of Pb(II) ions from aqueous media.


  • Open Access

    Determination of Pb(II) Ions in Water by Fluorescence Spectroscopy Based on Silver Nanoclusters

    by Luca Burratti, Valentin Maranges, Michele Sisani, Eziz Naryyev, Fabio De Matteis, Roberto Francini, Paolo Prosposito

    In this work, a method to determine Pb(II) ions in model water is presented; the method is based on the fluorescence emission of a silver nanoclusters (AgNCs) colloidal solution, which is sensitive to lead ions. The presence of Pb(II) ions causes a photoemission enhancement of the AgNCs solution dependent on the pollutant concentration. The functional dependence is logarithmic in the range from 2.5 to 40 µM, and through the linearization of the calibration points, a linear function is determined and exploited for the extrapolation of the test Pb(II) concentrations with a precision estimated by relative standard deviation (RSD) ranging from 21% to 10% from the highest to the lowest Pb(II) quantity, respectively. Finally, inductively coupled plasma–optical emission spectroscopy (ICP-OES) successfully validated the described method. The accuracy of the method is also studied for intentionally polluted mineral waters, revealing the same trend of the model water: the lower the concentration, the higher the precision of the method.