André Kemmling
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
André Kemmling has a total of 56 co-authors. Here are the top co-authors by number of shared publications:
- Christopher Nimsky
Department of Neurosurgery, Philipps-University Marburg, Marburg, Germany
6 shared publications - Abdallah Aburub
Department of Neuroradiology, Philipps University of Marburg, Marburg, Germany
4 shared publications - Ali Khanafer
Neuroradiology, Klinikum Stuttgart Katharinenhospital, Stuttgart, Germany
4 shared publications - Hans Henkes
Neuroradiology, Klinikum Stuttgart Katharinenhospital, Stuttgart, Germany
4 shared publications - Mohammad Almohammad
Department of Neuroradiology, Philipps University of Marburg, Marburg, Germany
4 shared publications - Zakarya Ali
Central Institute for Diagnostic and Interventional Radiology, Neuroradiology, and Nuclear Medicine, Sana Klinikum Offenbach, Offenbach, Germany
4 shared publications
Latest Publications
- Open Access
- 14 October 2026
- Published by Springer Nature in Neuroradiology
- p. 1-10
Longitudinal hematoma resolution after burr-hole evacuation with adjunctive scepter mini-assisted middle meningeal artery embolization: A multicenter matched cohort study
Objectives: To evaluate the radiographic and clinical outcomes of adjunctive middle meningeal artery embolization (MMAE) performed with the Scepter Mini dual-lumen balloon microcatheter following burr-hole evacuation for chronic subdural hematoma (cSDH), and to explore the feasibility of characterizing distal embolic penetration using the proposed MMA Embolization Penetration Score (MMA-EPS). Methods: This retrospective multicenter matched cohort study included consecutive patients with cSDH treated with burr-hole evacuation followed by adjunctive MMAE using the Scepter Mini and Onyx™ 18. A matched historical cohort treated with burr-hole evacuation alone served as controls. The primary endpoint was longitudinal hematoma thickness regression on serial computed tomography. Secondary endpoints included functional outcome, recurrence, all-cause mortality, and procedural safety. Results: Twenty-two patients with 38 embolized cSDHs were compared with 22 matched controls comprising 38 cSDHs. All embolized hematomas achieved MMA-EPS Grade 3 or 4 and demonstrated complete radiographic resolution by 6 months, whereas residual hematoma persisted in controls (0.0 ± 0.0 vs. 0.7 ± 0.9 mm). Favorable functional outcome (mRS 0–2) at 6 months was achieved in 86.4% versus 45.5% of patients. Exploratory analyses showed numerically lower recurrence (4.5% vs. 13.6%) and all-cause mortality (0% vs. 13.6%) following MMAE; however, the study was not powered to assess differences in these endpoints. Technical success was achieved in all embolizations without major procedure-related complications. Conclusion: Adjunctive MMAE using the Scepter Mini dual-lumen balloon microcatheter was associated with accelerated hematoma resolution, improved functional recovery, and an excellent procedural safety profile compared with burr-hole evacuation alone.
- 14 October 2026
- Published by Springer Nature in Neuroradiology
- p. 1-10
Open AccessLongitudinal hematoma resolution after burr-hole evacuation with adjunctive scepter mini-assisted middle meningeal artery embolization: A multicenter matched cohort study
Objectives: To evaluate the radiographic and clinical outcomes of adjunctive middle meningeal artery embolization (MMAE) performed with the Scepter Mini dual-lumen balloon microcatheter following burr-hole evacuation for chronic subdural hematoma (cSDH), and to explore the feasibility of characterizing distal embolic penetration using the proposed MMA Embolization Penetration Score (MMA-EPS). Methods: This retrospective multicenter matched cohort study included consecutive patients with cSDH treated with burr-hole evacuation followed by adjunctive MMAE using the Scepter Mini and Onyx™ 18. A matched historical cohort treated with burr-hole evacuation alone served as controls. The primary endpoint was longitudinal hematoma thickness regression on serial computed tomography. Secondary endpoints included functional outcome, recurrence, all-cause mortality, and procedural safety. Results: Twenty-two patients with 38 embolized cSDHs were compared with 22 matched controls comprising 38 cSDHs. All embolized hematomas achieved MMA-EPS Grade 3 or 4 and demonstrated complete radiographic resolution by 6 months, whereas residual hematoma persisted in controls (0.0 ± 0.0 vs. 0.7 ± 0.9 mm). Favorable functional outcome (mRS 0–2) at 6 months was achieved in 86.4% versus 45.5% of patients. Exploratory analyses showed numerically lower recurrence (4.5% vs. 13.6%) and all-cause mortality (0% vs. 13.6%) following MMAE; however, the study was not powered to assess differences in these endpoints. Technical success was achieved in all embolizations without major procedure-related complications. Conclusion: Adjunctive MMAE using the Scepter Mini dual-lumen balloon microcatheter was associated with accelerated hematoma resolution, improved functional recovery, and an excellent procedural safety profile compared with burr-hole evacuation alone.
- Open Access
- 15 September 2026
- Published by Springer Nature in Neuroradiology
- p. 1-9
Angioplasty and stenting of symptomatic intracranial atherosclerotic stenosis: a dual-center experience using NeuroSpeed balloon-catheter and CREDO heal stent
Background: Intracranial atherosclerotic stenosis (ICAS) remains a significant cause of recurrent ischemic strokes. While aggressive medical management is the mainstay of treatment, percutaneous transluminal angioplasty (PTA) and intracranial stenting (ICS) are increasingly used, especially in cases refractory to medical therapy or as a bailout during frustrating thrombectomy. Objective: To evaluate the safety, technical feasibility, and short-term outcomes of NeuroSpeed balloon-catheter angioplasty and CREDO heal stent implantation in patients with symptomatic ICAS with and without large or medium vessel occlusion (LVO/MeVO). Methods: This retrospective, dual-center study included 42 patients who underwent ICS using the NeuroSpeed balloon-catheter and fibrin-heparin coated CREDO heal stent. Patients were divided into two subgroups: ICAS ( n = 23) and Bailout stenting ( n = 19). Procedural success with a stenosis grade reduction to ≤ 50%, complication rates, and clinical outcomes were analyzed. Results: Technical success was achieved in 83% of cases. Clinical improvement was significant between baseline and follow-up, with a reduction in the median modified Rankin Scale score from 2 to 0 ( p = 0.005). Acute stent occlusion occurred in 2 of 19 patients (10.5%) in the bailout group. Late vascular follow-up imaging was available in 30 patients; two asymptomatic delayed stent occlusions occurred in the ICAS group (2/23, 8.7%) and two cases of in-stent restenosis in the bailout group (2/19, 10.5%). Procedure-related intracranial hemorrhage occurred in one patient in the ICAS group (1/23, 4.3%) and one patient in the bailout group (1/19, 5.3%). One access-site pseudoaneurysm (1/42, 2.4%) was observed. Conclusion: NeuroSpeed/CREDO-based intracranial stenting appears to be a technically feasible treatment for high-grade ICAS and as a bailout during thrombectomy, with favorable short-term clinical outcomes and acceptable complication rates. Further prospective studies are warranted to assess long-term safety, efficacy, and durability.
- 15 September 2026
- Published by Springer Nature in Neuroradiology
- p. 1-9
Open AccessAngioplasty and stenting of symptomatic intracranial atherosclerotic stenosis: a dual-center experience using NeuroSpeed balloon-catheter and CREDO heal stent
Background: Intracranial atherosclerotic stenosis (ICAS) remains a significant cause of recurrent ischemic strokes. While aggressive medical management is the mainstay of treatment, percutaneous transluminal angioplasty (PTA) and intracranial stenting (ICS) are increasingly used, especially in cases refractory to medical therapy or as a bailout during frustrating thrombectomy. Objective: To evaluate the safety, technical feasibility, and short-term outcomes of NeuroSpeed balloon-catheter angioplasty and CREDO heal stent implantation in patients with symptomatic ICAS with and without large or medium vessel occlusion (LVO/MeVO). Methods: This retrospective, dual-center study included 42 patients who underwent ICS using the NeuroSpeed balloon-catheter and fibrin-heparin coated CREDO heal stent. Patients were divided into two subgroups: ICAS ( n = 23) and Bailout stenting ( n = 19). Procedural success with a stenosis grade reduction to ≤ 50%, complication rates, and clinical outcomes were analyzed. Results: Technical success was achieved in 83% of cases. Clinical improvement was significant between baseline and follow-up, with a reduction in the median modified Rankin Scale score from 2 to 0 ( p = 0.005). Acute stent occlusion occurred in 2 of 19 patients (10.5%) in the bailout group. Late vascular follow-up imaging was available in 30 patients; two asymptomatic delayed stent occlusions occurred in the ICAS group (2/23, 8.7%) and two cases of in-stent restenosis in the bailout group (2/19, 10.5%). Procedure-related intracranial hemorrhage occurred in one patient in the ICAS group (1/23, 4.3%) and one patient in the bailout group (1/19, 5.3%). One access-site pseudoaneurysm (1/42, 2.4%) was observed. Conclusion: NeuroSpeed/CREDO-based intracranial stenting appears to be a technically feasible treatment for high-grade ICAS and as a bailout during thrombectomy, with favorable short-term clinical outcomes and acceptable complication rates. Further prospective studies are warranted to assess long-term safety, efficacy, and durability.
- Open Access
- 30 July 2026
- Published by Springer Nature in Neuroradiology
- Vol. 68 (10) , 3449-3460
Antithrombogenic coated self-expanding stent (pEGASUS-HPC) for the treatment of intracranial dissections of the cerebral arteries in acute stroke: a multicenter study
Background: Intracranial artery dissection (IADS) is an uncommon cause of acute ischemic stroke (AIS). In hyperacute settings, stenting is constrained by the need for intensive antiplatelet therapy. This study evaluated the antithrombogenic hydrophilic polymer–coated pEGASUS-HPC self-expanding stent for IADS-related AIS. Methods: This multicenter retrospective cohort study across seven stroke centers included consecutive patients with AIS and occlusion or severe flow-limiting stenosis caused by symptomatic IADS, who were treated with the pEGASUS-HPC. The outcomes were technical and angiographic success (device opening; mTICI score ≥2b when reperfusion was targeted), peri-procedural complications, mRS score, and follow-up patency. Results: In 36 treated patients (mean age 62.0 ± 19.6 years; 63.9% men), 91.7% of the dissections were spontaneous, and 80.6% were occlusive. Mechanical thrombectomy preceded stenting in 26/29 occlusive cases. Full stent opening occurred in 94.4%, and 100% reperfusion success was achieved in targeted vessels. Most patients received periprocedural intravenous antiplatelet bridging (75.0%) and were discharged on DAPT (77.8%). Whereas no intraprocedural complications occurred, four postprocedural events occurred during admission (11.1%), of which two were clinically significant and two were minor and asymptomatic. The mean NIHSS score improved from 11.8 at admission to 4.9 at discharge, and the mean discharge mRS score was 2.1. Clinical follow-up (mRS) was available in 33/36 patients (91.7%), with favorable functional outcome (mRS 0–2) in 27/33 (81.8%). Imaging follow-up at the early window (mean 94 days) was available in 27/36 (75.0%). In-stent stenosis ≥ 50% occurred in 14.8% and 4.2% of patients at early and mid-term follow-up, respectively, whereas no device occlusions or recurrent strokes occurred through mid-term follow-up. Long-term imaging follow-up (15/36, 41.7%) showed no new in-stent stenosis. Conclusions: pEGASUS-HPC stenting for IADS-related AIS was technically feasible and achieved high reperfusion rates and a low overall complication burden, thus supporting prospective evaluation with standardized antiplatelet protocols.
- 30 July 2026
- Published by Springer Nature in Neuroradiology
- Vol. 68 (10) , 3449-3460
Open AccessAntithrombogenic coated self-expanding stent (pEGASUS-HPC) for the treatment of intracranial dissections of the cerebral arteries in acute stroke: a multicenter study
Background: Intracranial artery dissection (IADS) is an uncommon cause of acute ischemic stroke (AIS). In hyperacute settings, stenting is constrained by the need for intensive antiplatelet therapy. This study evaluated the antithrombogenic hydrophilic polymer–coated pEGASUS-HPC self-expanding stent for IADS-related AIS. Methods: This multicenter retrospective cohort study across seven stroke centers included consecutive patients with AIS and occlusion or severe flow-limiting stenosis caused by symptomatic IADS, who were treated with the pEGASUS-HPC. The outcomes were technical and angiographic success (device opening; mTICI score ≥2b when reperfusion was targeted), peri-procedural complications, mRS score, and follow-up patency. Results: In 36 treated patients (mean age 62.0 ± 19.6 years; 63.9% men), 91.7% of the dissections were spontaneous, and 80.6% were occlusive. Mechanical thrombectomy preceded stenting in 26/29 occlusive cases. Full stent opening occurred in 94.4%, and 100% reperfusion success was achieved in targeted vessels. Most patients received periprocedural intravenous antiplatelet bridging (75.0%) and were discharged on DAPT (77.8%). Whereas no intraprocedural complications occurred, four postprocedural events occurred during admission (11.1%), of which two were clinically significant and two were minor and asymptomatic. The mean NIHSS score improved from 11.8 at admission to 4.9 at discharge, and the mean discharge mRS score was 2.1. Clinical follow-up (mRS) was available in 33/36 patients (91.7%), with favorable functional outcome (mRS 0–2) in 27/33 (81.8%). Imaging follow-up at the early window (mean 94 days) was available in 27/36 (75.0%). In-stent stenosis ≥ 50% occurred in 14.8% and 4.2% of patients at early and mid-term follow-up, respectively, whereas no device occlusions or recurrent strokes occurred through mid-term follow-up. Long-term imaging follow-up (15/36, 41.7%) showed no new in-stent stenosis. Conclusions: pEGASUS-HPC stenting for IADS-related AIS was technically feasible and achieved high reperfusion rates and a low overall complication burden, thus supporting prospective evaluation with standardized antiplatelet protocols.
- Open Access
- 25 July 2026
- Published by Springer Nature in Neuroradiology
- Vol. 68 (10) , 3439-3447
Comparison of pEGASUS-HPC stent pusher-assisted catheterization (PAC) in ruptured and unruptured wide-necked cerebral aneurysms: a multicenter study
Objectives: To compare the feasibility, efficiency, and safety of the pEGASUS-HPC stent pusher-assisted catheterization (PAC) technique between ruptured and unruptured wide-neck intracranial aneurysms treated with stent-assisted coiling. Methods: Multicenter retrospective study (June 2021–June 2025) evaluating the pEGASUS-HPC PAC technique in ruptured and unruptured wide-neck intracranial aneurysms treated with stent-assisted coiling. A microwire-assisted catheterization (MAC) cohort was included as a reference cohort. Primary endpoints were catheterization success and catheterization time; safety endpoints included perforation, dissection, and vasospasm. Results: A total of 151 patients with 186 aneurysms were analyzed, including a PAC cohort of 91 patients with 111 aneurysms (27 ruptured, 84 unruptured) and a MAC reference cohort of 60 patients with 75 unruptured aneurysms. Catheterization success was achieved in 26/27 ruptured aneurysms (96.3%) and 79/84 unruptured aneurysms (94.0%) ( p = 0.637). Mean catheterization time was 44 ± 14 s in ruptured aneurysms and 43 ± 21 s in unruptured aneurysms ( p = 0.78). No catheterization-related perforations or dissections occurred in either PAC group, and no major procedural complications were recorded. Compared with the MAC reference cohort (289 ± 78 s), PAC was associated with significantly shorter catheterization times in both ruptured and unruptured aneurysms (both p < 0.001) while maintaining high technical success rates. Conclusion: The PAC technique demonstrated high catheterization success rates, short catheterization times, and a favorable safety profile in both ruptured and unruptured wide-neck intracranial aneurysms. Aneurysm rupture status did not significantly influence procedural performance or safety. Larger prospective studies are warranted to confirm these findings and further define patient- and anatomy-specific indications for the technique.
- 25 July 2026
- Published by Springer Nature in Neuroradiology
- Vol. 68 (10) , 3439-3447
Open AccessComparison of pEGASUS-HPC stent pusher-assisted catheterization (PAC) in ruptured and unruptured wide-necked cerebral aneurysms: a multicenter study
Objectives: To compare the feasibility, efficiency, and safety of the pEGASUS-HPC stent pusher-assisted catheterization (PAC) technique between ruptured and unruptured wide-neck intracranial aneurysms treated with stent-assisted coiling. Methods: Multicenter retrospective study (June 2021–June 2025) evaluating the pEGASUS-HPC PAC technique in ruptured and unruptured wide-neck intracranial aneurysms treated with stent-assisted coiling. A microwire-assisted catheterization (MAC) cohort was included as a reference cohort. Primary endpoints were catheterization success and catheterization time; safety endpoints included perforation, dissection, and vasospasm. Results: A total of 151 patients with 186 aneurysms were analyzed, including a PAC cohort of 91 patients with 111 aneurysms (27 ruptured, 84 unruptured) and a MAC reference cohort of 60 patients with 75 unruptured aneurysms. Catheterization success was achieved in 26/27 ruptured aneurysms (96.3%) and 79/84 unruptured aneurysms (94.0%) ( p = 0.637). Mean catheterization time was 44 ± 14 s in ruptured aneurysms and 43 ± 21 s in unruptured aneurysms ( p = 0.78). No catheterization-related perforations or dissections occurred in either PAC group, and no major procedural complications were recorded. Compared with the MAC reference cohort (289 ± 78 s), PAC was associated with significantly shorter catheterization times in both ruptured and unruptured aneurysms (both p < 0.001) while maintaining high technical success rates. Conclusion: The PAC technique demonstrated high catheterization success rates, short catheterization times, and a favorable safety profile in both ruptured and unruptured wide-neck intracranial aneurysms. Aneurysm rupture status did not significantly influence procedural performance or safety. Larger prospective studies are warranted to confirm these findings and further define patient- and anatomy-specific indications for the technique.
- Open Access
- 15 November 2025
- Published by Springer Nature in Neuroradiology
- Vol. 67 (12) , 3429-3437
pEGASUS-HPC stent pusher assisted catheterization (PAC) technique in Y-stent-assisted coiling of unruptured wide-necked cerebral aneurysms
Objectives: To evaluate the safety and feasibility of the pusher-assisted catheterization (PAC) technique using the pEGASUS-HPC stent pusher instead of a microwire for accessing unruptured wide-necked cerebral aneurysms during Y-stent-assisted coiling. Methods: In this multicenter retrospective study (July 2021– June 2025), 48 unruptured wide-necked cerebral aneurysms underwent Y-stent-assisted coiling using pEGASUS HPC stents. Based on the catheterization technique, cases were assigned to either the microwire-assisted catheterization (MAC, n = 23) or the stent pusher-assisted catheterization (PAC, n = 25) group. Clinical and procedural data were analyzed to compare safety and efficacy, focusing on success rates, required catheterization time, complications, and adverse events. Results: The cohort had a mean age of 62.6 ± 9.8 years, with 64.3% of patients being female. In the MAC group, aneurysm catheterization was successful in all 23 cases (100%), with a mean catheterization time of 5.31 ± 1.2 min. In contrast, the PAC group achieved successful catheterization in 88% of cases (22/25), with a markedly reduced mean catheterization time of 0.82 ± 0.27 min—approximately 6.5 times faster than the conventional MAC technique ( p < 0.001). Importantly, no procedure-related complications, such as perforations or dissections, were observed in either group. Conclusion: In this multicenter retrospective feasibility and safety analysis, PAC appeared to enable faster aneurysm access during Y-stent-assisted coiling without an increase in intraprocedural complications. As clinical outcomes were not assessed, these findings should be regarded as technical proof-of-concept and require confirmation in prospective, outcome-driven studies.
- 15 November 2025
- Published by Springer Nature in Neuroradiology
- Vol. 67 (12) , 3429-3437
Open AccesspEGASUS-HPC stent pusher assisted catheterization (PAC) technique in Y-stent-assisted coiling of unruptured wide-necked cerebral aneurysms
Objectives: To evaluate the safety and feasibility of the pusher-assisted catheterization (PAC) technique using the pEGASUS-HPC stent pusher instead of a microwire for accessing unruptured wide-necked cerebral aneurysms during Y-stent-assisted coiling. Methods: In this multicenter retrospective study (July 2021– June 2025), 48 unruptured wide-necked cerebral aneurysms underwent Y-stent-assisted coiling using pEGASUS HPC stents. Based on the catheterization technique, cases were assigned to either the microwire-assisted catheterization (MAC, n = 23) or the stent pusher-assisted catheterization (PAC, n = 25) group. Clinical and procedural data were analyzed to compare safety and efficacy, focusing on success rates, required catheterization time, complications, and adverse events. Results: The cohort had a mean age of 62.6 ± 9.8 years, with 64.3% of patients being female. In the MAC group, aneurysm catheterization was successful in all 23 cases (100%), with a mean catheterization time of 5.31 ± 1.2 min. In contrast, the PAC group achieved successful catheterization in 88% of cases (22/25), with a markedly reduced mean catheterization time of 0.82 ± 0.27 min—approximately 6.5 times faster than the conventional MAC technique ( p < 0.001). Importantly, no procedure-related complications, such as perforations or dissections, were observed in either group. Conclusion: In this multicenter retrospective feasibility and safety analysis, PAC appeared to enable faster aneurysm access during Y-stent-assisted coiling without an increase in intraprocedural complications. As clinical outcomes were not assessed, these findings should be regarded as technical proof-of-concept and require confirmation in prospective, outcome-driven studies.
- Open Access
- 21 July 2025
- Published by Springer Nature in Neuroradiology
- Vol. 67 (9) , 2505-2518
Stent-assisted coiling and flow diversion with hpc-coated devices under prasugrel monotherapy in ruptured wide-neck aneurysms: a multicenter case series
Purpose To evaluate the safety, efficacy, and clinical outcomes of stent-assisted coiling (SAC) and flow diversion (FD) with hydrophilic polymer-coated (HPC) devices under prasugrel single antiplatelet therapy (SAPT) in the treatment of acutely ruptured wide-neck intracranial aneurysms. Methods This multicenter retrospective case series included patients with ruptured saccular intracranial aneurysms treated through SAC or FD with HPC-coated devices under SAPT at four specialized neurovascular centers. Baseline demographics, aneurysm characteristics, procedural details, and clinical outcomes were analyzed. The primary outcomes included technical success, periprocedural complications, aneurysm occlusion rates at follow-up (FU), and functional outcomes assessed with the modified Rankin Scale (mRS). Results A total of 46 patients were included (mean age 57.4 years). SAC and FD were performed in equal proportions. Technical success was achieved in 100% of cases. The immediate complete occlusion rate was significantly higher for SAC (95.7%) than FD (21.7%, p < 0.001). However, the occlusion rates at 12-month FU were comparable (SAC 100% vs. FD 95%, p = 0.364). The overall periprocedural complication rate was low (4.3%), and mortality before discharge was 10.9%. Favorable functional outcomes (mRS ≤ 2) at the last FU were achieved in 84% of patients, and no significant differences were observed between the SAC and FD groups. Conclusion SAC and FD with HPC-coated devices under prasugrel SAPT appeared to be safe and effective in treating ruptured wide-neck aneurysms. Whereas SAC achieved higher immediate occlusion rates, the long-term outcomes were comparable between groups. These findings support the feasibility of SAPT in this high-risk population and warrant further prospective validation.
- 21 July 2025
- Published by Springer Nature in Neuroradiology
- Vol. 67 (9) , 2505-2518
Open AccessStent-assisted coiling and flow diversion with hpc-coated devices under prasugrel monotherapy in ruptured wide-neck aneurysms: a multicenter case series
Purpose To evaluate the safety, efficacy, and clinical outcomes of stent-assisted coiling (SAC) and flow diversion (FD) with hydrophilic polymer-coated (HPC) devices under prasugrel single antiplatelet therapy (SAPT) in the treatment of acutely ruptured wide-neck intracranial aneurysms. Methods This multicenter retrospective case series included patients with ruptured saccular intracranial aneurysms treated through SAC or FD with HPC-coated devices under SAPT at four specialized neurovascular centers. Baseline demographics, aneurysm characteristics, procedural details, and clinical outcomes were analyzed. The primary outcomes included technical success, periprocedural complications, aneurysm occlusion rates at follow-up (FU), and functional outcomes assessed with the modified Rankin Scale (mRS). Results A total of 46 patients were included (mean age 57.4 years). SAC and FD were performed in equal proportions. Technical success was achieved in 100% of cases. The immediate complete occlusion rate was significantly higher for SAC (95.7%) than FD (21.7%, p < 0.001). However, the occlusion rates at 12-month FU were comparable (SAC 100% vs. FD 95%, p = 0.364). The overall periprocedural complication rate was low (4.3%), and mortality before discharge was 10.9%. Favorable functional outcomes (mRS ≤ 2) at the last FU were achieved in 84% of patients, and no significant differences were observed between the SAC and FD groups. Conclusion SAC and FD with HPC-coated devices under prasugrel SAPT appeared to be safe and effective in treating ruptured wide-neck aneurysms. Whereas SAC achieved higher immediate occlusion rates, the long-term outcomes were comparable between groups. These findings support the feasibility of SAPT in this high-risk population and warrant further prospective validation.
- Open Access
Effects of Tetrahydrolipstatin on Glioblastoma in Mice: MRI-Based Morphologic and Texture Analysis Correlated with Histopathology and Immunochemistry Findings—A Pilot Study
Background: This study aimed to investigate the effects of tetrahydrolipstatin (orlistat) on heterotopic glioblastoma in mice by applying MRI and correlating the results with histopathology and immunochemistry. Methods: Human glioblastoma cells were injected subcutaneously into the groins of immunodeficient mice. After tumor growth of >150 mm3, the animals were assigned into a treatment group (n = 6), which received daily intraperitoneal injections of orlistat, and a control group (n = 7). MRI was performed at the time of randomization and before euthanizing the animals. Tumor volumes were calculated, and signal intensities were analyzed. The internal tumor structure was evaluated visually and with texture analysis. Western blotting and protein expression analysis were performed. Results: At histology, all tumors showed high mitotic and proliferative activity (Ki67 ≥ 10%). Reduced fatty acid synthetase expression was measured in the orlistat group (p < 0.05). Based on the results of morphologic MRI-based analysis, tumor growth remained concentric in the control group and changed to eccentric in the treatment group (p < 0.05). The largest area under the receiver operating curve of the predictors derived from the texture analysis of T2w images was for wavelet transform parameters WavEnHL_s3 and WavEnLH_s4 at 0.96 and 1.00, respectively. Conclusions: Orlistat showed effects on heterotopically implanted glioblastoma multiforme in MRI studies of mice based on morphologic and texture analysis.
Open AccessEffects of Tetrahydrolipstatin on Glioblastoma in Mice: MRI-Based Morphologic and Texture Analysis Correlated with Histopathology and Immunochemistry Findings—A Pilot Study
Background: This study aimed to investigate the effects of tetrahydrolipstatin (orlistat) on heterotopic glioblastoma in mice by applying MRI and correlating the results with histopathology and immunochemistry. Methods: Human glioblastoma cells were injected subcutaneously into the groins of immunodeficient mice. After tumor growth of >150 mm3, the animals were assigned into a treatment group (n = 6), which received daily intraperitoneal injections of orlistat, and a control group (n = 7). MRI was performed at the time of randomization and before euthanizing the animals. Tumor volumes were calculated, and signal intensities were analyzed. The internal tumor structure was evaluated visually and with texture analysis. Western blotting and protein expression analysis were performed. Results: At histology, all tumors showed high mitotic and proliferative activity (Ki67 ≥ 10%). Reduced fatty acid synthetase expression was measured in the orlistat group (p < 0.05). Based on the results of morphologic MRI-based analysis, tumor growth remained concentric in the control group and changed to eccentric in the treatment group (p < 0.05). The largest area under the receiver operating curve of the predictors derived from the texture analysis of T2w images was for wavelet transform parameters WavEnHL_s3 and WavEnLH_s4 at 0.96 and 1.00, respectively. Conclusions: Orlistat showed effects on heterotopically implanted glioblastoma multiforme in MRI studies of mice based on morphologic and texture analysis.
- Open Access
Augmented Reality to Compensate for Navigation Inaccuracies
This study aims to report on the capability of microscope-based augmented reality (AR) to evaluate registration and navigation accuracy with extracranial and intracranial landmarks and to elaborate on its opportunities and obstacles in compensation for navigation inaccuracies. In a consecutive single surgeon series of 293 patients, automatic intraoperative computed tomography-based registration was performed delivering a high initial registration accuracy with a mean target registration error of 0.84 ± 0.36 mm. Navigation accuracy is evaluated by overlaying a maximum intensity projection or pre-segmented object outlines within the recent focal plane onto the in situ patient anatomy and compensated for by translational and/or rotational in-plane transformations. Using bony landmarks (85 cases), there was two cases where a mismatch was seen. Cortical vascular structures (242 cases) showed a mismatch in 43 cases and cortex representations (40 cases) revealed two inaccurate cases. In all cases, with detected misalignment, a successful spatial compensation was performed (mean correction: bone (6.27 ± 7.31 mm), vascular (3.00 ± 1.93 mm, 0.38° ± 1.06°), and cortex (5.31 ± 1.57 mm, 1.75° ± 2.47°)) increasing navigation accuracy. AR support allows for intermediate and straightforward monitoring of accuracy, enables compensation of spatial misalignments, and thereby provides additional safety by increasing overall accuracy.
Open AccessAugmented Reality to Compensate for Navigation Inaccuracies
This study aims to report on the capability of microscope-based augmented reality (AR) to evaluate registration and navigation accuracy with extracranial and intracranial landmarks and to elaborate on its opportunities and obstacles in compensation for navigation inaccuracies. In a consecutive single surgeon series of 293 patients, automatic intraoperative computed tomography-based registration was performed delivering a high initial registration accuracy with a mean target registration error of 0.84 ± 0.36 mm. Navigation accuracy is evaluated by overlaying a maximum intensity projection or pre-segmented object outlines within the recent focal plane onto the in situ patient anatomy and compensated for by translational and/or rotational in-plane transformations. Using bony landmarks (85 cases), there was two cases where a mismatch was seen. Cortical vascular structures (242 cases) showed a mismatch in 43 cases and cortex representations (40 cases) revealed two inaccurate cases. In all cases, with detected misalignment, a successful spatial compensation was performed (mean correction: bone (6.27 ± 7.31 mm), vascular (3.00 ± 1.93 mm, 0.38° ± 1.06°), and cortex (5.31 ± 1.57 mm, 1.75° ± 2.47°)) increasing navigation accuracy. AR support allows for intermediate and straightforward monitoring of accuracy, enables compensation of spatial misalignments, and thereby provides additional safety by increasing overall accuracy.
- Open Access
- 23 September 2022
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 11 (19) , 5590
Use of Neuronavigation and Augmented Reality in Transsphenoidal Pituitary Adenoma Surgery
The aim of this study was to report on the clinical experience with microscope-based augmented reality (AR) in transsphenoidal surgery compared to the classical microscope-based approach. AR support was established using the head-up displays of the operating microscope, with navigation based on fiducial-/surface- or automatic intraoperative computed tomography (iCT)-based registration. In a consecutive single surgeon series of 165 transsphenoidal procedures, 81 patients underwent surgery without AR support and 84 patients underwent surgery with AR support. AR was integrated straightforwardly within the workflow. ICT-based registration increased AR accuracy significantly (target registration error, TRE, 0.76 ± 0.33 mm) compared to the landmark-based approach (TRE 1.85 ± 1.02 mm). The application of low-dose iCT protocols led to a significant reduction in applied effective dosage being comparable to a single chest radiograph. No major vascular or neurological complications occurred. No difference in surgical time was seen, time to set-up patient registration prolonged intraoperative preparation time on average by twelve minutes (32.33 ± 13.35 vs. 44.13 ± 13.67 min), but seems justifiable by the fact that AR greatly and reliably facilitated surgical orientation and increased surgeon comfort and patient safety, not only in patients who had previous transsphenoidal surgery but also in cases with anatomical variants. Automatic intraoperative imaging-based registration is recommended.
- 23 September 2022
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 11 (19) , 5590
Open AccessUse of Neuronavigation and Augmented Reality in Transsphenoidal Pituitary Adenoma Surgery
The aim of this study was to report on the clinical experience with microscope-based augmented reality (AR) in transsphenoidal surgery compared to the classical microscope-based approach. AR support was established using the head-up displays of the operating microscope, with navigation based on fiducial-/surface- or automatic intraoperative computed tomography (iCT)-based registration. In a consecutive single surgeon series of 165 transsphenoidal procedures, 81 patients underwent surgery without AR support and 84 patients underwent surgery with AR support. AR was integrated straightforwardly within the workflow. ICT-based registration increased AR accuracy significantly (target registration error, TRE, 0.76 ± 0.33 mm) compared to the landmark-based approach (TRE 1.85 ± 1.02 mm). The application of low-dose iCT protocols led to a significant reduction in applied effective dosage being comparable to a single chest radiograph. No major vascular or neurological complications occurred. No difference in surgical time was seen, time to set-up patient registration prolonged intraoperative preparation time on average by twelve minutes (32.33 ± 13.35 vs. 44.13 ± 13.67 min), but seems justifiable by the fact that AR greatly and reliably facilitated surgical orientation and increased surgeon comfort and patient safety, not only in patients who had previous transsphenoidal surgery but also in cases with anatomical variants. Automatic intraoperative imaging-based registration is recommended.