ATAndrei Machado Viegas da Trindade

Andrei Machado Viegas da Trindade

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Andrei Machado Viegas da Trindade has a total of 37 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Dissociation Between Instrumented Mobility and Self-Reported Function in Adults Aged 70 Years or Older After Unilateral Total Knee Arthroplasty: A Preliminary Longitudinal Study Using an Inertial Sensor and the WOMAC

    by Andrei Machado Viegas da Trindade, Leonardo Pinheiro Rezende, Helder Rocha da Silva Araújo, Junichiro Sado, Karla Cristina Naves de Carvalho, Heytor Mendes Camargo Costa, Rafael Abrantes Jacinto, Allana Palma Fabricante, Veronica Cimolin, Rodolfo Borges Parreira, et al.

    Background and Objectives: Total knee arthroplasty (TKA) reliably reduces pain and improves self-reported function, yet objective mobility may remain impaired in older adults. We examined the relationship between inertial-sensor-based mobility and the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) in adults aged 70 years or older after unilateral TKA. Methods: In this observational longitudinal study, 25 participants were assessed at up to three postoperative time points (M1, first available assessment; M2, 2024 follow-up; M3, 2025 follow-up). Outcomes were the instrumented Timed Up and Go (TUG) test with segmented turning variables, the 2-Minute Walk Test (2MWT), spatiotemporal gait variables recorded with a trunk-mounted inertial measurement unit, and the WOMAC. Paired changes in the instrumented outcomes were tested with Wilcoxon signed-rank tests under Benjamini–Hochberg false-discovery-rate (FDR) control and are reported with bootstrap confidence intervals (CIs); longitudinal change in the WOMAC was not tested, because the response format used at the first assessment could not be established from the available records, so WOMAC scores are used only within time point; associations used Spearman correlations with bootstrap CIs and leave-one-out influence diagnostics. Individual-level agreement was examined by standardising each of three externally validated objective outcomes against the inverted WOMAC total score within time point and classifying discordance across a range of cut-offs. Observed changes in the instrumented outcomes were benchmarked against published minimal detectable change (MDC) values. Results: Participants were 75.56 ± 4.00 years old and 64.0% were women; 14 were reassessed at M2 and 2 at M3. No instrumented global outcome changed after FDR adjustment, and the median changes in total TUG time (+0.07 s) and 2MWT distance (+12.80 m) remained below published MDC95 values (2.27 s and 14.96 m). Mid-turn duration shortened by a median of 0.80 s (95% CI −0.93 to −0.28) and mid-turn peak and mean angular velocities increased by 16.55°/s (8.00 to 30.10) and 7.40°/s (1.30 to 14.15), all with FDR-adjusted p = 0.036. At M2, the WOMAC total score was inversely associated with walking speed (rho = −0.762, 95% CI −0.973 to −0.307), cadence (rho = −0.761) and 2MWT distance (rho = −0.644); these three associations retained their sign and significance in every leave-one-out refit and changed little on adjustment for age, body mass index or postoperative duration, whereas all M1 associations were weak. Between 42.9% and 57.1% of participants fell outside a ±0.5 standardised concordance band at M2 depending on which validated outcome was used, with no consistent asymmetry in either direction, and the estimated prevalence ranged from 7.1% to 85.7% across plausible cut-offs. Conclusions: Group-level association between patient-reported and instrumented outcomes coexists with frequent individual-level discordance, but the magnitude of that discordance is not stably estimable in a cohort of this size. WOMAC scores should not be assumed to substitute for objective mobility testing after TKA, and confirmation in larger prospective cohorts is required.

  • Open Access

    Walking Distance and Interlimb Gait Differences Across 51 kg of Weight Loss After Total Knee Arthroplasty: A Three-Session Wearable Sensor Case Report

    by Andrei Machado Viegas da Trindade, Leonardo Pinheiro Rezende, Junichiro Sado Junior, Marcos Henrique Alves Resende, Claudia Santos Oliveira

    Background and Clinical Significance: Longitudinal observations that combine major postoperative weight loss with limb-specific gait assessment after total knee arthroplasty (TKA) are uncommon. This case report describes three single-trial instrumented assessments in one patient and is intended as a descriptive observation; it does not establish causality, measurement stability, mechanical loading, or a clinically meaningful persistent deficit; Case Presentation: A man in his early sixties at the first assessment had undergone left TKA for end-stage osteoarthritis and subsequently underwent Roux-en-Y gastric bypass. Three assessments were available from approximately 31 to 67 months after TKA. Body mass was 120, 88, and 69 kg (body mass index 43.03, 31.55, and 24.74 kg/m2), while two-minute walk distance (2MWT) was 67.8, 105.1, and 118.1 m. The third walk test was launched in the software’s six-minute module and stopped at 1 min 58 s, so 118.1 m is the distance accumulated over 118 s and was neither adjusted nor extrapolated to 120 s. The operated limb showed longer stance duration than the non-operated limb by 3.04, 5.28, and 2.05 percentage points, and a proprietary propulsion index was lower on the operated side by 18.18%, 17.95%, and 14.06%; the direction of both differences was the same at every session but the magnitude was not, and the index has no published calculation or post-TKA interpretive threshold. Each session comprised one trial, and the third-session gait means were based on only five operated-limb and four non-operated-limb steps. Valid Timed Up and Go (TUG) totals were available for sessions 1 and 2 (13.41 and 14.95 s); the available source documentation did not contain a valid session-3 TUG result. Vendor-derived walk-test speed was excluded from primary interpretation because its calculation could not be reconciled with distance divided by test duration; Conclusions: Across these three observations, 2MWT distance increased while side-to-side differences in stance duration and the exploratory propulsion index were present at each session. These co-occurring changes cannot be attributed to weight loss specifically, because time since arthroplasty, rehabilitation exposure and repeated testing varied together with body mass. The findings are descriptive and hypothesis-generating; confirmation requires prospective studies with repeated trials per session, an adequate number of analysed steps, and validated kinetic or limb-specific outcomes.

  • Open Access

    Global Spatiotemporal Gait Performance and Ambulation Capacity After Total Knee Arthroplasty: A Longitudinal Comparison of Fixed-Bearing and Mobile-Bearing Prostheses

    by Andrei Machado Viegas da Trindade, Leonardo Pinheiro Rezende, Helder Rocha da Silva Araújo, Junichiro Sado Junior, Halley Paranhos Júnior, Karla Cristina Naves de Carvalho, Marcos Henrique Alves Resende, Heren Nepomuceno Costa Paixão, Juliana Oliveira Hassel Mendes, Veronica Cimolin, et al.

    Background: The choice between fixed-bearing (FB) and mobile-bearing (MB) prostheses in total knee arthroplasty (TKA) remains controversial, and longitudinal evidence based on objective instrumented assessment is limited. Objectives: To compare global spatiotemporal gait performance and ambulation capacity across three postoperative assessments in patients receiving FB versus MB/rotating-platform implants. Methods: In this retrospective, longitudinal, observational cohort study, patients who had undergone primary unilateral TKA were assessed at up to three postoperative visits approximately 12 months apart, the first at a median of 12 months after surgery. Gait speed, cadence, stride length, a step-time symmetry index and a gait quality index were obtained from a single lumbar-mounted inertial measurement unit during steady-state level walking, and ambulation capacity was measured with the 2-Minute Walk Test (2MWT). Linear mixed-effects models with a random intercept per patient, adjusted for age and sex, were fitted for all six outcomes, with time specified both as a linear term and, in a sensitivity analysis, as a categorical factor yielding estimated marginal means and between-group contrasts at each visit. Results: A total of 105 observations from 54 patients were analysed (29 FB, 25 MB/PS-RP). Groups were comparable at the first assessment on age, sex, body mass index, WOMAC score and all gait outcomes. No between-group difference reached statistical significance for any outcome, in either the linear or the categorical specification; all 18 visit-specific contrasts included the null value. Within the FB group, gait speed, stride length, the symmetry index, the gait quality index and 2MWT distance decreased significantly between the second and third assessments, a change based on six patients. Conclusions: Under the conditions of this study, no significant differences in global spatiotemporal gait performance or ambulation capacity were detected between FB and MB/rotating-platform prostheses. Because the study was not designed or powered as an equivalence trial, lacks preoperative and joint-level kinematic data, and cannot separate bearing design from the surgical approach with which it was collinear, these findings do not establish that the two designs perform equivalently.

  • Open Access

    Responsiveness of Outcome Measures in Chronic Non-Specific Low Back Pain: A Secondary Analysis of a Randomized Controlled Trial

    by Carlos Luques Fonseca, Pedro Augusto Silva Ribeiro, Karla Cristina Naves de Carvalho, Rodrigo Antonio Carvalho Andraus, Renata Calhes Franco de Moura, Andrei Machado Viegas da Trindade, Arislander Jonathan Lopes Dumont, Tiago Vieira Fernandes, Daniel Grossi Marconi, Hugo Pasin Neto, et al.

    Background/Objectives: Chronic non-specific low back pain (CNLBP) is a leading cause of disability worldwide. Although several randomized trials have evaluated treatment effectiveness, less attention has been given to the responsiveness of outcome measures used to assess clinical change. This study aimed to evaluate the internal and external responsiveness of commonly used outcome measures in individuals with CNLBP. Methods: This study is a secondary analysis of a randomized controlled trial. Participants were analyzed as active and placebo groups and assessed at baseline, post-intervention, and follow-up. Internal responsiveness was evaluated using standardized mean differences (SMD) and standardized response means (SRM). External responsiveness was assessed using anchor-based approaches, including correlations with the Global Rating of Change Scale (GRCS) and receiver operating characteristic (ROC) curve analysis. Results: Outcome measures demonstrated moderate to high internal responsiveness, with large effect sizes observed for pain intensity (NRS) and quality of life (EQ-5D-3L). However, external responsiveness was limited, with all instruments presenting area under the curve (AUC) values below 0.70. The Bournemouth Questionnaire showed the highest discriminative performance among the instruments. Conclusions: The evaluated instruments were sensitive to detecting change at the group level but showed limited ability to discriminate clinically meaningful improvement at the individual level. These findings support the use of combined outcome measures to improve clinical interpretation and decision-making in CNLBP.

  • Open Access

    Spatiotemporal Gait Parameters in Fixed Versus Rotating Bearing Total Knee Arthroplasty: A Prospective 24-Month Longitudinal Study

    by Andrei Machado Viegas da Trindade, Leonardo Pinheiro Rezende, Helder Rocha da Silva Araújo, Rodolfo Borges Parreira, Claudio Santili, Claudia Santos Oliveira

    Background/Objectives: The clinical superiority of rotating-bearing (RB) versus fixed-bearing (FB) total knee arthroplasty (TKA) remains controversial despite the proposed biomechanical advantages of mobile-bearing designs. Objective gait assessment with inertial measurement units (IMUs) provides a measurable view of functional recovery that may complement patient-reported outcome measures (PROMs). This study compared spatiotemporal gait parameters between FB and RB TKA over 24 months. Methods: This prospective longitudinal comparative study enrolled 57 patients undergoing primary unilateral TKA for end-stage knee osteoarthritis. Spatiotemporal gait parameters (gait velocity, cadence, and stance-phase duration) were measured using wireless IMUs (G-WALK system) at 6, 12, and 24 months post-surgery. WOMAC and the 10-point Geriatric Locomotive Function Scale (GLFS-10P) were assessed at 12 and 24 months. Group, time, and Group × Time effects were analyzed using linear mixed-effects models. Results: Both groups improved during follow-up, with performance largely plateauing between 12 and 24 months. At 24 months, there were no significant differences between groups in gait velocity (FB 1.17 vs. RB 1.16 m/s; p = 0.65), cadence (99.8 vs. 97.4 steps/min; p = 0.72), or stance-phase duration (59.3% vs. 59.0%; p = 0.82). Group × Time interactions were not significant across gait outcomes. WOMAC and GLFS-10P improved similarly in both groups (p > 0.05). Cadence was inversely correlated with the WOMAC function subscale at 24 months (rho = −0.563; p = 0.036). Conclusions: FB and RB bearing designs showed similar objective gait recovery trajectories and PROM improvements through 24 months after primary TKA, suggesting no intermediate-term functional advantage from bearing design.


  • Open Access

    Dynamic Ligament Balance After Total Knee Arthroplasty: A Comparative Finite Element Analysis

    by Helder Rocha da Silva Araujo, Andrei Machado Viegas da Trindade, Enio Chaves de Oliveira, Fern, a Grazielle da Silva Azevedo Nora

    Objectives: To compare postoperative gait biomechanics between patients aged ≤70 years and >70 years undergoing navigationassisted total knee arthroplasty (TKA), integrating intraoperative navigation data with patient-specific finite element analysis (FEA) to evaluate dynamic joint behavior and internal load distribution during gait. Methods: A retrospective analysis was performed on 402 primary unilateral TKAs implanted with the SCORE® prosthesis using the Amplivision® surgical navigation system. Intraoperative data acquisition included lower limb alignment expressed by the hip–knee–ankle (HKA) angle, dynamic ligament balance (GAP), coronal plane angular behavior (varus–valgus), femoral and tibial rotational kinematics, and implanted component dimensions. Postoperative gait biomechanics were reconstructed by interpolating joint positions recorded at 0°, 30°, 60°, and 90° of knee flexion. Patient-specific three-dimensional finite element models were developed to simulate physiological loading conditions throughout the entire gait cycle. Results: No statistically significant differences were identified between age groups with respect to lower limb alignment, coronal or rotational kinematics, or dynamic ligament balance during gait. In contrast, patients older than 70 years exhibited significantly higher contact pressures acting on the femoral component (p = 0.04) and a tendency toward increased stresses on the tibial component and polyethylene insert. Finite element simulations demonstrated that aging is associated with increased internal joint loading despite comparable postoperative kinematic patterns. Conclusion: Navigation-assisted TKA provides consistent restoration of postoperative alignment, kinematics, and ligament balance across different age groups. However, older patients experience higher internal articular stresses during gait, indicating that aging predominantly influences load transmission rather than joint kinematics. These findings highlight the importance of incorporating dynamic, load-based biomechanical assessment into postoperative evaluation, implant optimization, and long-term follow-up strategies in patients undergoing TKA.

  • Open Access

    Impact of Massive Weight Loss Following Bariatric Surgery on Gait Mechanics After Total Knee Arthroplasty: A Case Report

    by Andrei Machado Viegas da Trindade, Leonardo Pinheiro Rezende, Rodolfo Borges Parreira, Cláudio Santili, Helder Rocha da Silva Araújo, Veronica Cimolin, Rodrigo Antonio Carvalho Andraus, Karla Cristina Naves de Carvalho, Cláudia Santos Oliveira

    This case report describes longitudinal gait mechanics in a 62-year-old man who underwent left total knee arthroplasty (TKA) and subsequently laparoscopic sleeve gastrectomy with massive weight loss. Gait was evaluated using a wearable inertial sensor system at 6 months (T1) and 12 months (T2) after arthroplasty, alongside functional mobility and endurance tests (Timed Up and Go and 2-minute walk). Body mass decreased from 120 kg (BMI approximately 43 kg/m2) to 69 kg (BMI approximately 25 kg/m2) between T1 and T2. Despite the substantial reduction in mechanical loading, spatiotemporal gait parameters and pelvic kinematics remained largely stable, with persistent asymmetry and a compensatory gait strategy. Acceleration-derived estimates suggested approximately 42.5% mechanical offloading after weight loss. These findings indicate that, in this patient, massive postoperative weight loss did not translate into marked improvements in gait mechanics within the first year after TKA, underscoring the need for targeted rehabilitation even after successful weight reduction.

  • Open Access

    Spatiotemporal Gait Parameters in Fixed Versus Rotating Bearing Total Knee Arthroplasty: A Prospective 24-Month Longitudinal Study

    by Andrei Machado Viegas da Trindade, Leonardo Pinheiro Rezende, Helder Rocha da Silva Araújo, Rodolfo Borges Parreira, Claudio Santili, Claudia Santos Oliveira

    Background/Objectives: The clinical superiority of rotating-bearing (RB) versus fixed-bearing (FB) total knee arthroplasty (TKA) remains controversial despite the proposed biomechanical advantages of mobile-bearing designs. Objective gait assessment with inertial measurement units (IMUs) provides a measurable view of functional recovery that may complement patient-reported outcome measures (PROMs). This study compared spatiotemporal gait parameters between FB and RB TKA over 24 months. Methods: This prospective longitudinal comparative study enrolled 47 patients undergoing primary unilateral TKA for end-stage knee osteoarthritis. Spatiotemporal gait parameters (gait velocity, cadence, and stance-phase duration) were measured using wireless IMUs (G-WALK system) at 6, 12, and 24 months post-surgery. WOMAC and the 10-point Geriatric Locomotive Function Scale (GLFS-1) were assessed at 12 and 24 months. Group, time, and Group × Time effects were analyzed using linear mixed-effects models. Results: Both groups improved during follow-up, with performance largely plateauing between 12 and 24 months. At 24 months, there were no significant differences between groups in gait velocity (FB 1.17 vs. RB 1.16 m/s; p = 0.65), cadence (99.8 vs. 97.4 steps/min; p = 0.72), or stance-phase duration (59.3% vs. 59.0%; p = 0.82). Group × Time interactions were not significant across gait outcomes. WOMAC and GLFS-1 improved similarly in both groups (p > 0.05). Cadence was inversely correlated with the WOMAC function subscale at 24 months (rho = −0.563; p = 0.036). Conclusions: FB and RB bearing designs showed similar objective gait recovery trajectories and PROM improvements through 24 months after primary TKA, suggesting no intermediate-term functional advantage from bearing design.


  • Open Access

    Instrumented Functional Mobility Assessment in Elderly Patients Following Total Knee Arthroplasty: A Retrospective Longitudinal Study Using the Timed Up and Go Test

    by Andrei Machado Viegas da Trindade, Leonardo Pinheiro Rezende, Helder Rocha da Silva Araújo, Rodolfo Borges Parreira, Claudia Santos Oliveira

    In the context of the rising demand for total knee arthroplasty (TKA) in older adults and persistent uncertainty about the quality of long-term functional recovery, this study evaluated elderly patients’ mobility after unilateral TKA via a transquadriceps approach using instrumented Timed Up and Go (TUG) tests. A total of 20 patients treated between 2022 and 2024 at a tertiary hospital were invited to participate in this observational, retrospective, descriptive study, and 19 met the inclusion criteria (age 50–80 and Kellgren–Lawrence ≥ 4). The participants performed two TUG trials at two postoperative time points (18 and 53 months), with an inertial measurement unit (G-sensor) capturing 15 kinematic variables. When comparing the postoperative time points, it was found that the total TUG duration remained stable (14.97 ± 3.48 vs. 15.47 ± 2.93 s; p = 0.58), while the mid-turning peak velocity increased significantly (106.44 ± 30.96 vs. 132.77 ± 30.82°/s; p = 0.0039; r = 0.88). The end-turning velocity and sit-to-stand parameters showed small-to-moderate effect size gains without statistical significance. These findings suggest that, in the first year following surgery, patients continue to experience difficulties with movement fluidity and motor control—especially during turning—underscoring the value of segmented, sensor-based assessments and the need for extended rehabilitation protocols that emphasize rotational control and balance. These findings provide clinically relevant parameters that can support future interventional studies and help guide rehabilitation planning after TKA.


  • Open Access

    Quantitative Analysis of Functional Mobility in Elderly Patients Following Total Knee Arthroplasty via the Transquadriceps Approach

    by Andrei Trindade, Leonardo Rezende, Helder Araújo, Rodolfo Parreira, Cláudia Santos Oliveira

    In a context of rising demand for total knee arthroplasty (TKA) in older adults and persistent uncertainty about long-term functional recovery quality, this study evaluated elderly patients’ mobility after unilateral TKA via a transquadriceps approach using instrumented Timed Up and Go (TUG) tests. In this observational, retrospective, descriptive study, 54 patients treated between 2022 and 2024 at a tertiary hospital were invited, and 19 met inclusion criteria (age 50–80, Kellgren–Lawrence ≥4). Participants performed three TUG trials at two postoperative time points (mean 17.3 and 42.8 months), with a G-Walk inertial sensor capturing 15 kinematic variables. Descriptive statistics, Shapiro–Wilk tests, paired t-tests, Wilcoxon signed-rank tests, effect sizes (Cohen’s d, r), and Spearman/Pearson correlations were applied. Total TUG duration remained stable (14.97 ± 3.48 vs. 15.47 ± 2.93 s; p = 0.58), while mid-turning peak velocity increased significantly (106.44 ± 30.96 vs. 132.77 ± 30.82°/s; p = 0.0039; r = 0.88). End-turning velocity and sit-to-stand parameters showed moderate to small effect-size gains without statistical significance. These findings indicate that, beyond the first postoperative year, patients refine movement fluidity and motor control—especially during turning—underscoring the value of segmented, sensor-based assessments and the need for extended rehabilitation protocols emphasizing rotational control and balance.