Shrivatsal Sharma
Shrivatsal Sharma has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Subhashish Bhattacharya
North Carolina State University
8 shared publications - Vishnu Mahadeva Iyer
Department of Electrical Engineering, Indian Institute of Science, Bengaluru, India
5 shared publications - Ke Zou
Ford Motor Company, Dearborn, MI, USA
2 shared publications - Awneesh Kumar Tripathi
Eaton Corporation, Menomonee Falls, WI, USA
1 shared publication - Iosu Aizpuru
Electronics and Computing Department, Mondragon Unibertsitatea, Hernani, Spain
1 shared publication - Jesús Sergio Artal-Sevil
Departamento de Ingeniería Eléctrica, Universidad de Zaragoza, C/María de Luna, 3, 50018 Zaragoza, Spain
1 shared publication
Latest Publications
- 22 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 41 (9) , 15921-15934
Fault Current Minimization and Fault Ride-Through Control of Triple-Active Bridge DC–DC Converters Using Particle Swarm Optimization
The fault ride-through (FRT) capability of triple active bridge (TAB) converters is crucial for maintaining reliable operation in DC Microgrids (MGs) during short-circuit faults (SCF). This paper proposes an optimization-based FRT control strategy for TAB DC–DC converters operating under DC SCF conditions. A generalized harmonic approximation (GHA) based steady-state fault model is utilized to characterize port current behavior during fault operation and to enable control-oriented evaluation of fault current stress. Based on this model, a particle swarm optimization (PSO) based triple phase shift (TPS) modulation strategy is proposed that minimizes cumulative RMS currents across all converter ports and maintains the required power transfer between healthy ports during FRT operation. The PSO algorithm is implemented as a background routine during normal operation to obtain optimized TPS modulation parameters. During fault conditions, the controller applies these pre-calculated settings directly, ensuring rapid response while preserving deterministic real-time control without additional CPU burden. Through simulation and experimental results, it is shown that proposed method has superior performance compared to existing methods using single phase shit (SPS) and double phase shift (DPS) modulations. The proposed strategy confirms its effectiveness in improving TAB converter fault resilience and operational continuity.
- 22 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 41 (9) , 15921-15934
Fault Current Minimization and Fault Ride-Through Control of Triple-Active Bridge DC–DC Converters Using Particle Swarm Optimization
The fault ride-through (FRT) capability of triple active bridge (TAB) converters is crucial for maintaining reliable operation in DC Microgrids (MGs) during short-circuit faults (SCF). This paper proposes an optimization-based FRT control strategy for TAB DC–DC converters operating under DC SCF conditions. A generalized harmonic approximation (GHA) based steady-state fault model is utilized to characterize port current behavior during fault operation and to enable control-oriented evaluation of fault current stress. Based on this model, a particle swarm optimization (PSO) based triple phase shift (TPS) modulation strategy is proposed that minimizes cumulative RMS currents across all converter ports and maintains the required power transfer between healthy ports during FRT operation. The PSO algorithm is implemented as a background routine during normal operation to obtain optimized TPS modulation parameters. During fault conditions, the controller applies these pre-calculated settings directly, ensuring rapid response while preserving deterministic real-time control without additional CPU burden. Through simulation and experimental results, it is shown that proposed method has superior performance compared to existing methods using single phase shit (SPS) and double phase shift (DPS) modulations. The proposed strategy confirms its effectiveness in improving TAB converter fault resilience and operational continuity.
- 7 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Industrial Electronics
- Vol. 6 (3) , 1140-1152
Analysis of Plug-In and Plug-Out of Converters in Droop Controlled DC Microgrid Systems
This article presents methodologies to achieve seamless plug-in and plug-out of converters in droop-controlled DC MG systems. It is shown that the typical approach of pre-charging the converter to the nominal voltage before plugging it into a droop-controlled DC MG system can result in high transients in converter currents, which can trigger the system's shutdown. New and effective methodologies are presented to achieve seamless plug-in and plug-out of a converter from the DC MG system. The seamless plug-in is achieved by controlling the reference voltage of the converter and plug-out is achieved by controlling the droop resistances. The proposed methodologies act as damping techniques to minimize the transients in converter currents. The methodologies are implemented using the conventional droop control and thus are simple to implement. An analytical model is developed for a generic DC MG system to analyze the performance of the system during a hot swap of a converter. The model is also used to propose guidelines for controller design to achieve seamless plug-in and plug-out of a converter. Extensive experimental results on different configurations and operating points of MG systems are provided to validate the proposed methodologies.
- 7 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Industrial Electronics
- Vol. 6 (3) , 1140-1152
Analysis of Plug-In and Plug-Out of Converters in Droop Controlled DC Microgrid Systems
This article presents methodologies to achieve seamless plug-in and plug-out of converters in droop-controlled DC MG systems. It is shown that the typical approach of pre-charging the converter to the nominal voltage before plugging it into a droop-controlled DC MG system can result in high transients in converter currents, which can trigger the system's shutdown. New and effective methodologies are presented to achieve seamless plug-in and plug-out of a converter from the DC MG system. The seamless plug-in is achieved by controlling the reference voltage of the converter and plug-out is achieved by controlling the droop resistances. The proposed methodologies act as damping techniques to minimize the transients in converter currents. The methodologies are implemented using the conventional droop control and thus are simple to implement. An analytical model is developed for a generic DC MG system to analyze the performance of the system during a hot swap of a converter. The model is also used to propose guidelines for controller design to achieve seamless plug-in and plug-out of a converter. Extensive experimental results on different configurations and operating points of MG systems are provided to validate the proposed methodologies.
- 28 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 71 (8) , 8938-8948
A Distributed Control Method With Seamless Hot Swap Capability for Generic DC Microgrids
This article proposes a distributed secondary control method for droop-controlled dc microgrid (MG) systems with ring or mesh configurations. The control method achieves accurate current sharing and improved load voltage regulation than the conventional droop method by using the bus voltage information of any bus of the dc MG system. The secondary controllers are implemented locally at each converter, thus ensuring a distributed control. The proposed method requires communication of only one signal per communication link and it needs less number of communication links than the state-of-the-art distributed secondary control methods. The method also offers a seamless hot swap capability of a converter as there is no interdependence between the secondary controllers of the converters. The effectiveness of the proposed method is validated using switching simulations and hardware-based experiments on different configurations of dc MG systems.
- 28 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 71 (8) , 8938-8948
A Distributed Control Method With Seamless Hot Swap Capability for Generic DC Microgrids
This article proposes a distributed secondary control method for droop-controlled dc microgrid (MG) systems with ring or mesh configurations. The control method achieves accurate current sharing and improved load voltage regulation than the conventional droop method by using the bus voltage information of any bus of the dc MG system. The secondary controllers are implemented locally at each converter, thus ensuring a distributed control. The proposed method requires communication of only one signal per communication link and it needs less number of communication links than the state-of-the-art distributed secondary control methods. The method also offers a seamless hot swap capability of a converter as there is no interdependence between the secondary controllers of the converters. The effectiveness of the proposed method is validated using switching simulations and hardware-based experiments on different configurations of dc MG systems.
- 5 July 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. 10 (1) , 1680-1691
Performance Improvement of a Silicon Partial Power Converter Over a Silicon Carbide Full Power Converter
This article studies the new benefits that partial power processing brings to Silicon (Si) devices compared to wide-bandgap technologies. To prove this, the proposed case study consists of an on-board charger (OBC) application in which a Si-based partial power converter (PPC) is compared with a Silicon Carbide (SiC) based full power converter (FPC). The OBC application considers three different technologies of lithium-ion batteries and the main comparison metrics are: semiconductor switching, temperature rise of semiconductors, volume and device losses (efficiency). This last one is oriented to energy losses (Wh) and not to power losses (W) as classical design. An analytical model is used to compute switching and conduction losses. Depending on the operating point, switching events are segregated into zero voltage switching (ZVS), incomplete ZVS and hard switching. It is shown that the Si-based PPC may enter non-ZVS in certain operating conditions. However, its efficiency remains above 99 %, producing up to 5 times lower energy losses than the SiC-based FPC. Also, the case temperature of the semiconductors is halved and a reduction in the volume and electrical stress of the devices is achieved. This permits a global multi-objective optimization. The results are experimentally validated using a 3 kW prototype of SiC-based FPC and Si-based PPC.
- 5 July 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. 10 (1) , 1680-1691
Performance Improvement of a Silicon Partial Power Converter Over a Silicon Carbide Full Power Converter
This article studies the new benefits that partial power processing brings to Silicon (Si) devices compared to wide-bandgap technologies. To prove this, the proposed case study consists of an on-board charger (OBC) application in which a Si-based partial power converter (PPC) is compared with a Silicon Carbide (SiC) based full power converter (FPC). The OBC application considers three different technologies of lithium-ion batteries and the main comparison metrics are: semiconductor switching, temperature rise of semiconductors, volume and device losses (efficiency). This last one is oriented to energy losses (Wh) and not to power losses (W) as classical design. An analytical model is used to compute switching and conduction losses. Depending on the operating point, switching events are segregated into zero voltage switching (ZVS), incomplete ZVS and hard switching. It is shown that the Si-based PPC may enter non-ZVS in certain operating conditions. However, its efficiency remains above 99 %, producing up to 5 times lower energy losses than the SiC-based FPC. Also, the case temperature of the semiconductors is halved and a reduction in the volume and electrical stress of the devices is achieved. This permits a global multi-objective optimization. The results are experimentally validated using a 3 kW prototype of SiC-based FPC and Si-based PPC.
- 22 February 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Industrial Electronics
- Vol. 4 (3) , 969-981
Droop-Based Distributed Secondary Control Method With Reduced Communication Complexity for Radial DC Microgrids
This paper proposes a distributed secondary control method for radial DC microgrid systems with reduced communication complexity. The proposed method utilizes the bus voltage information of the DC microgrid, which is communicated to the individual converters. The proposed method is distributed in nature as the secondary controllers are implemented locally at each converter. The proposed method does not require communication channels between individual converters. Thus, it achieves accurate current sharing and good load voltage regulation with reduced complexity compared to state-of-the-art control methods. The proposed method is robust, and its performance gracefully degrades in the event of a failure of a communication channel. Also, the addition or removal of a converter is seamless with the proposed method. The effectiveness of the proposed method is validated using circuit simulations and hardware-based experiments on different configurations of radial DC microgrid systems.
- 22 February 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Industrial Electronics
- Vol. 4 (3) , 969-981
Droop-Based Distributed Secondary Control Method With Reduced Communication Complexity for Radial DC Microgrids
This paper proposes a distributed secondary control method for radial DC microgrid systems with reduced communication complexity. The proposed method utilizes the bus voltage information of the DC microgrid, which is communicated to the individual converters. The proposed method is distributed in nature as the secondary controllers are implemented locally at each converter. The proposed method does not require communication channels between individual converters. Thus, it achieves accurate current sharing and good load voltage regulation with reduced complexity compared to state-of-the-art control methods. The proposed method is robust, and its performance gracefully degrades in the event of a failure of a communication channel. Also, the addition or removal of a converter is seamless with the proposed method. The effectiveness of the proposed method is validated using circuit simulations and hardware-based experiments on different configurations of radial DC microgrid systems.
- 22 February 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 71 (1) , 560-571
New Mesh Configurations With Decentralized Droop Control Method for DC Microgrids
This article proposes new, practical, and scalable mesh configurations for dc microgrids. The new mesh configurations are inspired by the concepts in graph theory. A decentralized secondary droop control method without involving communication complexity is also presented in this article. The proposed control method eliminates the limitations of the conventional droop control method in the scenarios where the cable resistances in a dc microgrid system cannot be neglected. The new mesh configurations with the proposed control method achieve accurate current sharing among all the converters. The effectiveness and performance of the proposed control method are validated using circuit simulations and hardware-based experiments on existing and proposed configurations of multi-converter dc microgrid systems.
- 22 February 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 71 (1) , 560-571
New Mesh Configurations With Decentralized Droop Control Method for DC Microgrids
This article proposes new, practical, and scalable mesh configurations for dc microgrids. The new mesh configurations are inspired by the concepts in graph theory. A decentralized secondary droop control method without involving communication complexity is also presented in this article. The proposed control method eliminates the limitations of the conventional droop control method in the scenarios where the cable resistances in a dc microgrid system cannot be neglected. The new mesh configurations with the proposed control method achieve accurate current sharing among all the converters. The effectiveness and performance of the proposed control method are validated using circuit simulations and hardware-based experiments on existing and proposed configurations of multi-converter dc microgrid systems.
- 14 December 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. 9 (4) , 4964-4980
ZVS Boundary Analysis and Design Guideline of MV Grid-Compliant Solid-State Transformer for DC Fast Charger Applications
A solid-state transformer comprising a cascaded H-bridge and a dual-active bridge converter is a promising solution for a megawatt medium voltage DC fast charger application. The new IEEE Std 1547.9-2022 comprehensively discusses extending the minimum reactive power capability to electric vehicle chargers. This paper analyzes the impact of operating the grid compliant single-phase solid-state transformer on the overall system. The impact of the DC-link voltage due to the single-phase implementation of the H-bridges on the dual-active bridge converter zero-voltage switching mode at light-load operation is highlighted. The system’s operational boundary is analyzed, which defines the reactive power capability limit while ensuring the dual-active bridge converter zero-voltage switching mode operation for the defined operating points. This zero-voltage switching mode boundary analysis is then used to develop a design guideline as part of the solid-state transformer design process. The proposed guideline allows a simultaneous design of a DC-link capacitor and dual active bridge inductance to ensure zero-voltage switching mode for the defined operating points. It leads to DC-link capacitance reduction that offers cost-and footprint-savings. The proposed concept is validated through simulations and experimental results. Further, a potential benefit analysis is provided to emphasize the effectiveness of the proposed concept. A supplementary video is included to showcase the system’s dynamic active and reactive power operation.
- 14 December 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. 9 (4) , 4964-4980
ZVS Boundary Analysis and Design Guideline of MV Grid-Compliant Solid-State Transformer for DC Fast Charger Applications
A solid-state transformer comprising a cascaded H-bridge and a dual-active bridge converter is a promising solution for a megawatt medium voltage DC fast charger application. The new IEEE Std 1547.9-2022 comprehensively discusses extending the minimum reactive power capability to electric vehicle chargers. This paper analyzes the impact of operating the grid compliant single-phase solid-state transformer on the overall system. The impact of the DC-link voltage due to the single-phase implementation of the H-bridges on the dual-active bridge converter zero-voltage switching mode at light-load operation is highlighted. The system’s operational boundary is analyzed, which defines the reactive power capability limit while ensuring the dual-active bridge converter zero-voltage switching mode operation for the defined operating points. This zero-voltage switching mode boundary analysis is then used to develop a design guideline as part of the solid-state transformer design process. The proposed guideline allows a simultaneous design of a DC-link capacitor and dual active bridge inductance to ensure zero-voltage switching mode for the defined operating points. It leads to DC-link capacitance reduction that offers cost-and footprint-savings. The proposed concept is validated through simulations and experimental results. Further, a potential benefit analysis is provided to emphasize the effectiveness of the proposed concept. A supplementary video is included to showcase the system’s dynamic active and reactive power operation.
- 21 September 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Industrial Electronics
- Vol. 4 (1) , 3-13
An Optimized Nonlinear Droop Control Method Using Load Profile for DC Microgrids
Paralleling of power electronic converters to achieve current sharing is a critical aspect of a dc microgrid. Droop control is a popular technique to parallel converters. This article presents a novel perspective of different practically realizable nonlinear droop characteristics. Using the probability distribution function of the load current, a methodology is proposed to optimize the characteristics of nonlinear droop control. In a stand-alone dc microgrid system, the load current information used in the proposed control method is typically known using historical data or can be estimated using load forecasting methods. The advantages of the proposed nonlinear droop control method over several state-of-the art nonlinear droop control methods are discussed and shown. The effectiveness of the proposed nonlinear droop control method is validated using circuit simulations and hardware-based experiments on a multiconverter system for different load profiles.
- 21 September 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Industrial Electronics
- Vol. 4 (1) , 3-13
An Optimized Nonlinear Droop Control Method Using Load Profile for DC Microgrids
Paralleling of power electronic converters to achieve current sharing is a critical aspect of a dc microgrid. Droop control is a popular technique to parallel converters. This article presents a novel perspective of different practically realizable nonlinear droop characteristics. Using the probability distribution function of the load current, a methodology is proposed to optimize the characteristics of nonlinear droop control. In a stand-alone dc microgrid system, the load current information used in the proposed control method is typically known using historical data or can be estimated using load forecasting methods. The advantages of the proposed nonlinear droop control method over several state-of-the art nonlinear droop control methods are discussed and shown. The effectiveness of the proposed nonlinear droop control method is validated using circuit simulations and hardware-based experiments on a multiconverter system for different load profiles.