Zhide Zhou
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Zhide Zhou has a total of 58 co-authors. Here are the top co-authors by number of shared publications:
- Guiyin Li
College of Chemistry, Guangdong University of Petrochemical Technology, Maoming, Guangdong, China
15 shared publications - Jintao Liang
School of Life and Environmental Sciences, Guilin University of Electronic Technology, Guilin, Guangxi 541004, PR China
12 shared publications Xinhao Li
College of Chemistry, Guangdong University of Petrochemical Technology, Maoming, People’s Republic of China
8 shared publicationsJintao Liang
School of Life and Environmental Sciences, School of Intellectual Property, Guilin University of Electronic Technology, Guilin, People’s Republic of China
7 shared publicationsXiaohong Tan
College of Chemistry, School of Materials Science and Engineering, Guangdong University of Petrochemical Technology, Guandu Road, Maoming, Guangdong 525000, PR China
7 shared publicationsShengnan Li
College of Chemistry, Guangdong University of Petrochemical Technology, Maoming, People’s Republic of China
6 shared publications
Latest Publications
- 24 September 2025
- Published by Elsevier in Bioelectrochemistry
- Vol. 168, 109121
A colorimetric/electrochemical dual-mode aptasensor for Golgi protein 73 detection using TMB as a bifunctional probe
- 24 September 2025
- Published by Elsevier in Bioelectrochemistry
- Vol. 168, 109121
A colorimetric/electrochemical dual-mode aptasensor for Golgi protein 73 detection using TMB as a bifunctional probe
- 7 July 2025
- Published by Springer Nature in Microchimica Acta
- Vol. 192 (8) , 1-17
A label-free electrochemical aptasensor utilizing NRGO-Fc-Pt@Pd NPs for ultrasensitive detection of Golgi protein 73 in human serum
Golgi protein 73 (GP73) is highly expressed in hepatocellular carcinoma (HCC) and considered a sensitive serum biomarker for HCC diagnosis. Herein, a label-free electrochemical aptasensor for ultrasensitive detection GP73 based on nitrogen-doped reduced graphene oxide-ferrocene-platinum@palladium nanoparticles (NRGO-Fc-Pt@Pd NPs) was constructed. The NRGO-Fc-Pt@Pd NPs offered excellent conductivity, biocompatibility, and large surface area, serving as both an electrode modifier and a redox probe due to Fc's good electroactivity. GP73 aptamer (GP73Apt) was covalently bound with the NRGO-Fc-Pt@Pd NPs to form the signal probe. When GP73 specifically bound to GP73Apt to form GP73-GP73Apt complex and fell off from the electrode, it leads to an increased Fc(Fe(II)/Fe(III)) peak current in differential pulse voltammetry (DPV) due to the enhancing of the sensing interface's electroactivity. Under optimized conditions, the label-free electrochemical aptasensor demonstrated a linear relationship with GP73 concentration in the range 1.0 ng/mL-300 ng/mL, with R2 of 0.99594 and a limit of detection (LOD) of 0.3524 ng/mL. In addition, the aptasensor showed good specificity, reproducibility, and stability. Furthermore, the developed aptasensor was applied to detect the GP73 in actual serum samples with good recoveries (97.85%-107.48%) and relative standard deviations (RSDs) (0.37%–7.85%) via the spiked recovery method. All the results may provide a new approach for HCC clinical detection. Graphical Abstract
- 7 July 2025
- Published by Springer Nature in Microchimica Acta
- Vol. 192 (8) , 1-17
A label-free electrochemical aptasensor utilizing NRGO-Fc-Pt@Pd NPs for ultrasensitive detection of Golgi protein 73 in human serum
Golgi protein 73 (GP73) is highly expressed in hepatocellular carcinoma (HCC) and considered a sensitive serum biomarker for HCC diagnosis. Herein, a label-free electrochemical aptasensor for ultrasensitive detection GP73 based on nitrogen-doped reduced graphene oxide-ferrocene-platinum@palladium nanoparticles (NRGO-Fc-Pt@Pd NPs) was constructed. The NRGO-Fc-Pt@Pd NPs offered excellent conductivity, biocompatibility, and large surface area, serving as both an electrode modifier and a redox probe due to Fc's good electroactivity. GP73 aptamer (GP73Apt) was covalently bound with the NRGO-Fc-Pt@Pd NPs to form the signal probe. When GP73 specifically bound to GP73Apt to form GP73-GP73Apt complex and fell off from the electrode, it leads to an increased Fc(Fe(II)/Fe(III)) peak current in differential pulse voltammetry (DPV) due to the enhancing of the sensing interface's electroactivity. Under optimized conditions, the label-free electrochemical aptasensor demonstrated a linear relationship with GP73 concentration in the range 1.0 ng/mL-300 ng/mL, with R2 of 0.99594 and a limit of detection (LOD) of 0.3524 ng/mL. In addition, the aptasensor showed good specificity, reproducibility, and stability. Furthermore, the developed aptasensor was applied to detect the GP73 in actual serum samples with good recoveries (97.85%-107.48%) and relative standard deviations (RSDs) (0.37%–7.85%) via the spiked recovery method. All the results may provide a new approach for HCC clinical detection. Graphical Abstract
- 1 January 2025
- Published by World Scientific Publishing House Ltd in CREATIVE ECONOMY
- Vol. 9 (5) , 45-49
The Dilemma and Path Optimisation of SEP Licensing Antitrust Regulationunder the Perspective of New Quality Productivity
Under the background of new quality productivity to promote high-quality development, standard essential patents (SEPs), as a product of the fusion of technical standards and patents, have become a key challenge in restricting innovation and market competition through the misuse of SEP licences. This paper analyses the causes of SEP licensing abuse from three aspects: the endogenous logic of technical standards, the imbalance of market structure and the dilemma of international regulatory coordination, pointing out that the network effect of technical standards and the concentration of patents have led to SEP right holders obtaining the right to over-market bargaining power, and that the differences in the international rules have further exacerbated the loopholes in regulation. In view of the deviation of China's current anti-monopoly regulation, the study reveals that the ambiguous criteria for determining the dominant market position, the unclear definition of "unfairly high price" and the unclear boundaries of the rules for injunctive relief have led to the judicial practice facing the risk of inconsistency in the judgement scale and insufficient protection of the public interest. In this regard, the study proposes optimisation strategies: defining dominant market position through dynamic evaluation mechanism, constructing compound FRAND licensing fee calculation standard, and improving judicial review rules for injunctive relief, so as to balance the patentee and the public interest. The study emphasises the need to continue to improve the SEP legal regulatory system and strengthen the adaptability and coordination of antitrust regulation, so as to create a fair and efficient innovation ecosystem for the development of new productivity.
- 1 January 2025
- Published by World Scientific Publishing House Ltd in CREATIVE ECONOMY
- Vol. 9 (5) , 45-49
The Dilemma and Path Optimisation of SEP Licensing Antitrust Regulationunder the Perspective of New Quality Productivity
Under the background of new quality productivity to promote high-quality development, standard essential patents (SEPs), as a product of the fusion of technical standards and patents, have become a key challenge in restricting innovation and market competition through the misuse of SEP licences. This paper analyses the causes of SEP licensing abuse from three aspects: the endogenous logic of technical standards, the imbalance of market structure and the dilemma of international regulatory coordination, pointing out that the network effect of technical standards and the concentration of patents have led to SEP right holders obtaining the right to over-market bargaining power, and that the differences in the international rules have further exacerbated the loopholes in regulation. In view of the deviation of China's current anti-monopoly regulation, the study reveals that the ambiguous criteria for determining the dominant market position, the unclear definition of "unfairly high price" and the unclear boundaries of the rules for injunctive relief have led to the judicial practice facing the risk of inconsistency in the judgement scale and insufficient protection of the public interest. In this regard, the study proposes optimisation strategies: defining dominant market position through dynamic evaluation mechanism, constructing compound FRAND licensing fee calculation standard, and improving judicial review rules for injunctive relief, so as to balance the patentee and the public interest. The study emphasises the need to continue to improve the SEP legal regulatory system and strengthen the adaptability and coordination of antitrust regulation, so as to create a fair and efficient innovation ecosystem for the development of new productivity.
- 27 December 2024
- Published by Springer Nature in Microchimica Acta
- Vol. 192 (1) , 1-16
Carbon-based light addressable potential aptasensor based on the synergy of C-MXene@rGO and OPD@NGQDs for low-density lipoprotein detection
A novel carbon-based light-addressable potentiometric aptasensor (C-LAPS) was constructed for detection low-density lipoprotein (LDL) in serum. Carboxylated Ti3C2 MXene @reduced graphene oxide (C-MXene@rGO) was used as interface and o-phenylenediamine functionalized nitrogen-doped graphene quantum dots (OPD@NGQDs) as the photoelectric conversion element. The photosensitive layers composed of OPD@NGQDs/C-MXene@rGO exhibit superior photoelectric conversion efficiency and excellent biocompatibility, which contribute to an improved response signal. When LDL reacts with the LDL aptamer (LDLApt) immobilized on the photosensitive layers to form LDL-LDLApt complexes, the reaction process can induce the modification of the surface potential in the photosensitive layer, leading to potential shift observed through the I-V curves. The experimental conditions were successfully optimized with few planned tests by applying the Box-Behnken design and response surface methodology aspects of the Design-Expert software. Under the optimal condition, the potential shift had a linear relationship with concentrations of LDL from 0.02 to 0.30 μg/mL. The limit of detection (LOD) was 5.88 ng/mL (S/N = 3) and the sensitivity was 315.20 mV/μg·mL−1. In addition, the LDL C-LAPS demonstrated excellent specificity, reproducibility, and stability in detecting LDL. The sensor performed well in quantifying LDL in real samples. Therefore, the LDL C-LAPS has the potential for clinical applications. Graphical Abstract
- 27 December 2024
- Published by Springer Nature in Microchimica Acta
- Vol. 192 (1) , 1-16
Carbon-based light addressable potential aptasensor based on the synergy of C-MXene@rGO and OPD@NGQDs for low-density lipoprotein detection
A novel carbon-based light-addressable potentiometric aptasensor (C-LAPS) was constructed for detection low-density lipoprotein (LDL) in serum. Carboxylated Ti3C2 MXene @reduced graphene oxide (C-MXene@rGO) was used as interface and o-phenylenediamine functionalized nitrogen-doped graphene quantum dots (OPD@NGQDs) as the photoelectric conversion element. The photosensitive layers composed of OPD@NGQDs/C-MXene@rGO exhibit superior photoelectric conversion efficiency and excellent biocompatibility, which contribute to an improved response signal. When LDL reacts with the LDL aptamer (LDLApt) immobilized on the photosensitive layers to form LDL-LDLApt complexes, the reaction process can induce the modification of the surface potential in the photosensitive layer, leading to potential shift observed through the I-V curves. The experimental conditions were successfully optimized with few planned tests by applying the Box-Behnken design and response surface methodology aspects of the Design-Expert software. Under the optimal condition, the potential shift had a linear relationship with concentrations of LDL from 0.02 to 0.30 μg/mL. The limit of detection (LOD) was 5.88 ng/mL (S/N = 3) and the sensitivity was 315.20 mV/μg·mL−1. In addition, the LDL C-LAPS demonstrated excellent specificity, reproducibility, and stability in detecting LDL. The sensor performed well in quantifying LDL in real samples. Therefore, the LDL C-LAPS has the potential for clinical applications. Graphical Abstract
- 27 November 2024
- Published by Elsevier in Bioelectrochemistry
- Vol. 162, 108855
Label-free determination of glypican-3 using PtPd@H-rGO nanocomposites decorated light-addressable potentiometric sensor
- 27 November 2024
- Published by Elsevier in Bioelectrochemistry
- Vol. 162, 108855
Label-free determination of glypican-3 using PtPd@H-rGO nanocomposites decorated light-addressable potentiometric sensor
- 19 October 2024
- Published by Springer Nature in Microchimica Acta
- Vol. 191 (11) , 1-17
A sandwich-type electrochemical sensor based on RGO-CeO2-Au nanoparticles and double aptamers for ultrasensitive detection of glypican-3
A sandwich-type electrochemical aptasensor for ultrasensitive detection of glypican-3 (GPC3) was constructed using GPC3 aptamer (GPC3Apt) labelled reduced graphene oxide-cerium oxide-gold nanoparticles (RGO-CeO2-Au NPs) as the signal probe and the same GPC3Apt as the capture probe. The electrochemical redox properties of CeO2 (Ce3+/Ce4+) in the RGO-CeO2-Au NPs indicate the electrochemical signals. When the target GPC3 was present, an “aptamer-protein-aptamer” sandwich structure was formed on the sensing interface due to the specific binding between the protein and aptamers, resulting in an increased electrochemical redox signal detected by differential pulse voltammetry (DPV) technique. Under optimal conditions, the established aptasensor exhibited a logarithmic linear relationship between the current response and GPC3 concentration in the range 0.001–100.0 ng/mL, with a minimum detection limit of 0.74 pg/mL. Using the spike-recovery tests for measurement of the human serum samples, the recovery was from 99.26 to 114.01%, and the RSD range was 3.04 to 5.34%. Furthermore, the sandwich-type electrochemical aptasensor exhibited excellent performance characteristics such as good stability, high specificity, and high sensitivity, demonstrating effective detection of GPC3 in human serum samples and can be used as a clinical detection tool for GPC3. Graphical Abstract
- 19 October 2024
- Published by Springer Nature in Microchimica Acta
- Vol. 191 (11) , 1-17
A sandwich-type electrochemical sensor based on RGO-CeO2-Au nanoparticles and double aptamers for ultrasensitive detection of glypican-3
A sandwich-type electrochemical aptasensor for ultrasensitive detection of glypican-3 (GPC3) was constructed using GPC3 aptamer (GPC3Apt) labelled reduced graphene oxide-cerium oxide-gold nanoparticles (RGO-CeO2-Au NPs) as the signal probe and the same GPC3Apt as the capture probe. The electrochemical redox properties of CeO2 (Ce3+/Ce4+) in the RGO-CeO2-Au NPs indicate the electrochemical signals. When the target GPC3 was present, an “aptamer-protein-aptamer” sandwich structure was formed on the sensing interface due to the specific binding between the protein and aptamers, resulting in an increased electrochemical redox signal detected by differential pulse voltammetry (DPV) technique. Under optimal conditions, the established aptasensor exhibited a logarithmic linear relationship between the current response and GPC3 concentration in the range 0.001–100.0 ng/mL, with a minimum detection limit of 0.74 pg/mL. Using the spike-recovery tests for measurement of the human serum samples, the recovery was from 99.26 to 114.01%, and the RSD range was 3.04 to 5.34%. Furthermore, the sandwich-type electrochemical aptasensor exhibited excellent performance characteristics such as good stability, high specificity, and high sensitivity, demonstrating effective detection of GPC3 in human serum samples and can be used as a clinical detection tool for GPC3. Graphical Abstract
- 20 August 2024
- Published by Springer Nature in Microchimica Acta
- Vol. 191 (9) , 1-16
A novel electrochemical aptasensor based on NrGO-H-Mn3O4 NPs integrated CRISPR/Cas12a system for ultrasensitive low-density lipoprotein determination
Atherosclerosis cardiovascular disease (ASCVD) has become one of the leading death causes in humans. Low-density lipoprotein (LDL) is an important biomarker for assessing ASCVD risk level. Thus, monitoring LDL levels can be an important means for early diagnosis of ASCVD. Herein, a novel electrochemical aptasensor for determination LDL was designed based on nitrogen-doped reduced graphene oxide-hemin-manganese oxide nanoparticles (NrGO-H-Mn3O4 NPs) integrated with clustered regularly interspaced short palindromic repeats and associated proteins (CRISPR/Cas12a) system. NrGO-H-Mn3O4 NPs not only have a large surface area and remarkable enhanced electrical conductivity but also the interconversion of different valence states of iron in hemin can provide an electrical signal. Nonspecific single-stranded DNA (ssDNA) was bound to NrGO-H-Mn3O4 NPs to form a signaling probe and was immobilized on the electrode surface. The CRISPR/Cas12a system has excellent trans-cleavage activity, which can be used to cleave ssDNA, thus detaching the NrGO-H-Mn3O4 NPs from the sensing interface and attenuating the electrical signal. Significant signal change triggered by the target was ultimately obtained, thus achieving sensitive detection of the LDL in range from 0.005 to 1000.0 nM with the detection limit of 0.005 nM. The proposed sensor exhibited good stability, selectivity, and stability and achieved reliable detection of LDL in serum samples, demonstrating its promising application prospects for the diagnostic application of LDL. Graphical abstract
- 20 August 2024
- Published by Springer Nature in Microchimica Acta
- Vol. 191 (9) , 1-16
A novel electrochemical aptasensor based on NrGO-H-Mn3O4 NPs integrated CRISPR/Cas12a system for ultrasensitive low-density lipoprotein determination
Atherosclerosis cardiovascular disease (ASCVD) has become one of the leading death causes in humans. Low-density lipoprotein (LDL) is an important biomarker for assessing ASCVD risk level. Thus, monitoring LDL levels can be an important means for early diagnosis of ASCVD. Herein, a novel electrochemical aptasensor for determination LDL was designed based on nitrogen-doped reduced graphene oxide-hemin-manganese oxide nanoparticles (NrGO-H-Mn3O4 NPs) integrated with clustered regularly interspaced short palindromic repeats and associated proteins (CRISPR/Cas12a) system. NrGO-H-Mn3O4 NPs not only have a large surface area and remarkable enhanced electrical conductivity but also the interconversion of different valence states of iron in hemin can provide an electrical signal. Nonspecific single-stranded DNA (ssDNA) was bound to NrGO-H-Mn3O4 NPs to form a signaling probe and was immobilized on the electrode surface. The CRISPR/Cas12a system has excellent trans-cleavage activity, which can be used to cleave ssDNA, thus detaching the NrGO-H-Mn3O4 NPs from the sensing interface and attenuating the electrical signal. Significant signal change triggered by the target was ultimately obtained, thus achieving sensitive detection of the LDL in range from 0.005 to 1000.0 nM with the detection limit of 0.005 nM. The proposed sensor exhibited good stability, selectivity, and stability and achieved reliable detection of LDL in serum samples, demonstrating its promising application prospects for the diagnostic application of LDL. Graphical abstract
- 13 June 2024
- Published by Elsevier in Bioelectrochemistry
- Vol. 160, 108767
Competitive electrochemical aptasensor for high sensitivity detection of liver cancer marker GP73 based on rGO-Fc-PANi nanocomposites
- 13 June 2024
- Published by Elsevier in Bioelectrochemistry
- Vol. 160, 108767
Competitive electrochemical aptasensor for high sensitivity detection of liver cancer marker GP73 based on rGO-Fc-PANi nanocomposites