Christoph Moos
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Christoph Moos has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Bernd Wöstmann
Department of Prosthodontics, Justus Liebig University Giessen, Schlangenzahl 14, 35392 Giessen, Germany
3 shared publications - Maximiliane Amelie Schlenz
Department of Prosthodontics, Christian Albrecht University of Kiel, University Hospital Schleswig-Holstein, Campus Kiel, Arnold-Heller-Str. 3, 24105 Kiel, Germany
3 shared publications - Christin Grill
Medical Laser Center Lübeck, Peter-Monnik-Weg 4, 23562 Lübeck, Germany
2 shared publications - Julie-Jacqueline Kuhl
Department of Prosthodontics, Christian Albrecht University of Kiel, University Hospital Schleswig-Holstein, Campus Kiel, Arnold-Heller-Str. 3, 24105 Kiel, Germany
2 shared publications - Ralf Brinkmann
Medical Laser Center Luebeck, Luebeck, Germany
2 shared publications - Stefan Kolling
Institute of Mechanics and Materials, Technische Hochschule Mittelhessen, Wiesenstr. 14, 35390 Giessen, Germany
2 shared publications
Latest Publications
- Open Access
- 14 July 2026
- Published by MDPI AG in Bioengineering
- Vol. 13 (7) , 808
Prediction of Subsurface Fatigue Damage in Dental CAD/CAM Restorations: Intraoral Scanning vs. Optical Coherence Tomography
This study extended a previously established intraoral scanning (IOS) and optical coherence tomography (OCT) dual-modality monitoring workflow for computer-aided design/computer-aided manufacturing (CAD/CAM) restorations to three additional crown material classes alongside a resin composite (RECO) reference. Four material classes were investigated ( each): RECO, polymer-infiltrated ceramic network (PICN), lithium disilicate ceramic (LDSC), and zirconia-reinforced lithium silicate ceramic (ZLSC). Monolithic crowns were adhesively luted to standardized human molar abutment teeth and aged by cyclic loading (50500, 2, 37 2, up to 1250000 cycles) in a mouth-motion simulator. IOS and handheld OCT were performed at baseline and after every 250000 cycles under phantom-head conditions; correspondence was assessed using Spearman’s rank correlation coefficient (exploratory, uncorrected for multiple comparisons). OCT consistently showed higher defect extents than IOS across all material classes and timepoints. While no significant IOS-OCT associations were found for RECO and the PICN, OCT detected full-thickness vertical subsurface damage propagation from the earliest timepoint in LDSC and ZLSC, with IOS-derived surface wear remaining markedly lower. Surface-based monitoring alone did not reliably reflect subsurface damage propagation, a dissociation most pronounced in the vertical dimension and silicate-based materials. Intraoral OCT may provide complementary, non-invasive subsurface information to support individualized recall scheduling and minimally invasive repair decisions.- 14 July 2026
- Published by MDPI AG in Bioengineering
- Vol. 13 (7) , 808
Open AccessPrediction of Subsurface Fatigue Damage in Dental CAD/CAM Restorations: Intraoral Scanning vs. Optical Coherence Tomography
This study extended a previously established intraoral scanning (IOS) and optical coherence tomography (OCT) dual-modality monitoring workflow for computer-aided design/computer-aided manufacturing (CAD/CAM) restorations to three additional crown material classes alongside a resin composite (RECO) reference. Four material classes were investigated ( each): RECO, polymer-infiltrated ceramic network (PICN), lithium disilicate ceramic (LDSC), and zirconia-reinforced lithium silicate ceramic (ZLSC). Monolithic crowns were adhesively luted to standardized human molar abutment teeth and aged by cyclic loading (50500, 2, 37 2, up to 1250000 cycles) in a mouth-motion simulator. IOS and handheld OCT were performed at baseline and after every 250000 cycles under phantom-head conditions; correspondence was assessed using Spearman’s rank correlation coefficient (exploratory, uncorrected for multiple comparisons). OCT consistently showed higher defect extents than IOS across all material classes and timepoints. While no significant IOS-OCT associations were found for RECO and the PICN, OCT detected full-thickness vertical subsurface damage propagation from the earliest timepoint in LDSC and ZLSC, with IOS-derived surface wear remaining markedly lower. Surface-based monitoring alone did not reliably reflect subsurface damage propagation, a dissociation most pronounced in the vertical dimension and silicate-based materials. Intraoral OCT may provide complementary, non-invasive subsurface information to support individualized recall scheduling and minimally invasive repair decisions. - Open Access
- 3 February 2026
- Published by MDPI AG in Dentistry Journal
- Vol. 14 (2) , 84
Discrepancy Between Surface Wear and Subsurface Fatigue Damage in CAD/CAM Composite Crowns: A Comparative Study of Intraoral Scans and Optical Coherence Tomography
Objectives: This study aimed to determine whether surface wear, identified through the superimposition of intraoral scans (IOS), can predict subsurface damage progression detected by optical coherence tomography (OCT) during fatigue testing of computer-aided design/computer-aided manufacturing (CAD/CAM) composite crowns. Methods: Monolithic CAD/CAM composite crowns (Brilliant Crios; ) were adhesively luted to standardized prepared human teeth and artificially aged by cyclic loading in a mouth-motion simulator (50–500 N, 2 Hz, 37 °C). Under phantom-head condition, IOS (surface wear) and handheld swept-source (SS)-OCT (subsurface damage) were performed before loading and after every 250,000 cycles. OCT crack depth/width were normalized to local thickness and cusp-tip distance; correspondence between IOS- and OCT-derived metrics at each timepoint was assessed with Spearman’s rank correlation coefficient () to test whether surface wear can predict subsurface damage under the given conditions. Results: All specimens survived without catastrophic failure, and both modalities revealed progressive damage from the earliest observation interval. OCT consistently showed higher defect percentages and larger dispersion (e.g., mean vertical defects (25.47 ± 4.97)% OCT vs. (4.36 ± 0.91)% IOS at T1 and (66.79 ± 19.53)% OCT vs. (7.78 ± 3.19)% IOS at T5). Across all timepoints, no statistically significant associations between IOS and OCT were observed (p = 0.146 to 0.955). Conclusions: Within the limitations of this exploratory, single-material in vitro study, restricted to a CAD/CAM composite (Brilliant Crios), surface-based monitoring alone did not reliably reflect subsurface damage progression. Clinically, this suggests that surface wear assessment may underestimate subsurface fatigue damage. Intraoral OCT may provide complementary, non-invasive information alongside routine IOS for individualized monitoring, but its added value needs to be confirmed in larger studies and other CAD/CAM composite materials and additional restorative material classes.- 3 February 2026
- Published by MDPI AG in Dentistry Journal
- Vol. 14 (2) , 84
Open AccessDiscrepancy Between Surface Wear and Subsurface Fatigue Damage in CAD/CAM Composite Crowns: A Comparative Study of Intraoral Scans and Optical Coherence Tomography
Objectives: This study aimed to determine whether surface wear, identified through the superimposition of intraoral scans (IOS), can predict subsurface damage progression detected by optical coherence tomography (OCT) during fatigue testing of computer-aided design/computer-aided manufacturing (CAD/CAM) composite crowns. Methods: Monolithic CAD/CAM composite crowns (Brilliant Crios; ) were adhesively luted to standardized prepared human teeth and artificially aged by cyclic loading in a mouth-motion simulator (50–500 N, 2 Hz, 37 °C). Under phantom-head condition, IOS (surface wear) and handheld swept-source (SS)-OCT (subsurface damage) were performed before loading and after every 250,000 cycles. OCT crack depth/width were normalized to local thickness and cusp-tip distance; correspondence between IOS- and OCT-derived metrics at each timepoint was assessed with Spearman’s rank correlation coefficient () to test whether surface wear can predict subsurface damage under the given conditions. Results: All specimens survived without catastrophic failure, and both modalities revealed progressive damage from the earliest observation interval. OCT consistently showed higher defect percentages and larger dispersion (e.g., mean vertical defects (25.47 ± 4.97)% OCT vs. (4.36 ± 0.91)% IOS at T1 and (66.79 ± 19.53)% OCT vs. (7.78 ± 3.19)% IOS at T5). Across all timepoints, no statistically significant associations between IOS and OCT were observed (p = 0.146 to 0.955). Conclusions: Within the limitations of this exploratory, single-material in vitro study, restricted to a CAD/CAM composite (Brilliant Crios), surface-based monitoring alone did not reliably reflect subsurface damage progression. Clinically, this suggests that surface wear assessment may underestimate subsurface fatigue damage. Intraoral OCT may provide complementary, non-invasive information alongside routine IOS for individualized monitoring, but its added value needs to be confirmed in larger studies and other CAD/CAM composite materials and additional restorative material classes. - Open Access
- 30 December 2025
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 176, 107328
Calibration of Drucker–Prager plasticity in prosthetic materials: From experimental characterization to reverse-engineering finite element analysis
- 30 December 2025
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 176, 107328
Open AccessCalibration of Drucker–Prager plasticity in prosthetic materials: From experimental characterization to reverse-engineering finite element analysis
- Open Access
- 26 September 2022
- Published by MDPI AG in Pharmaceuticals
- Vol. 15 (10) , 1188
Tablets Made from Paper—An Industrially Feasible Approach
Many orally administrated drugs exhibit poor bioavailability due to their limited solubility. The smartFilm technology is an innovative approach to improve the drug aqueous solubility, where the drug is embedded within the matrix of cellulose-based paper in an amorphous state, hence increasing its solubility. Despite its proven effectiveness, smartFilms, i.e., pieces of paper, exhibit limited flowability and are not easy to swallow, and thus oral administration is not convenient. In addition, there is a lack of knowledge of their mechanical behavior under compression. This study aimed to transform unloaded smartFilms, i.e., paper, into a flowable physical form and investigated its mechanical behavior when compressed. Granules made of paper were prepared via wet granulation and were compressed into tablets. The influence of using different amounts and forms of sucrose, as a binder, on the pharmaceutical properties of the produced granules and tablets was studied and the most suitable composition was identified by using instrumented die experiments. For this, the Poisson’s ratio and Young’s modulus were determined for different compaction force levels and the deformation behavior was estimated with the Heckel mathematical model. All granule batches showed good flowability with angle of repose values between 25–35°. Granule batches with ≤30% dry sucrose content produced tablets that fulfilled the European Pharmacopeia requirements, and the compaction behavior of the granules was found to be comparable to the behavior of classical binders and compression enhancers. Paper can be transferred into granules. These granules can be used as suitable intermediate products for the production of tablets made of paper in large, industrial scale.
- 26 September 2022
- Published by MDPI AG in Pharmaceuticals
- Vol. 15 (10) , 1188
Open AccessTablets Made from Paper—An Industrially Feasible Approach
Many orally administrated drugs exhibit poor bioavailability due to their limited solubility. The smartFilm technology is an innovative approach to improve the drug aqueous solubility, where the drug is embedded within the matrix of cellulose-based paper in an amorphous state, hence increasing its solubility. Despite its proven effectiveness, smartFilms, i.e., pieces of paper, exhibit limited flowability and are not easy to swallow, and thus oral administration is not convenient. In addition, there is a lack of knowledge of their mechanical behavior under compression. This study aimed to transform unloaded smartFilms, i.e., paper, into a flowable physical form and investigated its mechanical behavior when compressed. Granules made of paper were prepared via wet granulation and were compressed into tablets. The influence of using different amounts and forms of sucrose, as a binder, on the pharmaceutical properties of the produced granules and tablets was studied and the most suitable composition was identified by using instrumented die experiments. For this, the Poisson’s ratio and Young’s modulus were determined for different compaction force levels and the deformation behavior was estimated with the Heckel mathematical model. All granule batches showed good flowability with angle of repose values between 25–35°. Granule batches with ≤30% dry sucrose content produced tablets that fulfilled the European Pharmacopeia requirements, and the compaction behavior of the granules was found to be comparable to the behavior of classical binders and compression enhancers. Paper can be transferred into granules. These granules can be used as suitable intermediate products for the production of tablets made of paper in large, industrial scale.