GMGopi Maguluri

Gopi Maguluri

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Gopi Maguluri has a total of 36 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    AI-Assisted OCT Imaging for Core Needle Biopsy Guidance: The 1st in Humans Study

    by Nicusor Iftimia, Poonam Yadav, Michael Primrose, Gopi Maguluri, Jack Jones, John Grimble, Rahul Anil Sheth

    Background: The heterogeneous nature of cancer with varying degrees of fat, necrosis, fibrosis, and varying degrees of tissue repair severely impacts the success of acquiring adequate tissue samples during percutaneous image-guided biopsy. Although ultrasound or CT fluoroscopy are used to identify tumor location and thus to guide biopsy needle insertion, these technologies do not provide the necessary resolution to determine tissue composition and enable the selection of the most appropriate location for biopsy specimen extraction. As a result, biopsy must be repeated, leading to significant cost to the health care system. Methods: In this study, we introduce a combined optical imaging/artificial intelligence (OI/AI) methodology for the real-time assessment of tissue morphology at the tip of the biopsy needle, prior to the collection of a biopsy specimen. Addressing a significant clinical challenge, this approach aims to reduce the proportion of biopsy cores—currently as high as 40%—that yield low diagnostic value due to elevated adipose or low tumor content. Our methodology employs micron-scale optical coherence tomography (OCT) imaging to obtain detailed structural tissue information using a minimally invasive needle probe. The OCT images are automatically analyzed using a convolutional neural network (CNN)-driven AI software developed by our team. A U-net style architecture was used to segment regions of tumor from the OCT scans. U-Net is a specialized convolutional neural network (CNN) architecture designed for fast, precise image segmentation, which involves classifying each pixel in an image to outline objects. This streamlined approach shows promise to provide clinicians with real-time results, supporting more accurate and informed decisions regarding biopsy site selection. To evaluate this technology, we conducted a clinical study using a custom-made OCT imager and recorded OCT images from patients diagnosed with liver cancers. Expert OCT interpreters supplied annotated reference images that were used to train a custom AI algorithm. Results: OCT imaging with ~10 mm axial and 20 mm lateral resolution enabled the collection of high-quality images of the tissue. The AI analysis was performed offline. UNet achieved an AUC of ~0.877 on the validation dataset, indicating promising performance for the relatively small data set used to train the model. The AI model matched human interpretations approximately 90% of the time, highlighting its promise for making biopsy procedures both more accurate and more efficient. Conclusions: A novel OCT instrument and AI software were evaluated for assessing tissue composition at the tip of biopsy needle. The OCT instrument produced micron-scale resolution images of the tissue, enabling AI analysis and accurate real-time discrimination of tissue type. This preliminary study demonstrated the clinical potential of this technology for improving biopsy success.

  • Open Access

    In vivo assessment of airway wall compliance during inhalation injury response using anatomical optical coherence elastography

    by Yinghan Xu, Srikamal Soundararajan, Scott H. Randell, Nicusor Iftimia, Gopi Maguluri, John Grimble, Carlton J. Zdanski, Amy L. Oldenburg

    Inhalation injury occurs from pulmonary exposure to a variety of chemicals, such as smoke, vapors, and gases.1 It constitutes a significant cause of morbidity and mortality in patients with severe burns.2 According to the Centers for Disease Control and Prevention, 398,000 burn injuries required medical treatment in 2021, resulting in 3800 deaths due to smoke inhalation.3 Inhalation injury affects the pulmonary system due to a combination of factors, including heat, hypoxemia, and the chemical effects of toxic inhalants.4 The high mortality rate associated with inhalation injury may be improved by standardized and objective diagnostic criteria. The current gold standard for diagnosing inhalation injury is flexible bronchoscopy and the use of the Abbreviated Injury Score criteria5 to determine injury severity. However, a drawback of the injury scoring system is its subjectivity, as interpretation may vary among examining physicians.6 Therefore, a more quantitative method is necessary to assess inhalation injury effectively and inform evolving strategies for burn treatment. Here, we address this need by exploring a method for endoscopic, optical coherence elastography that has the potential to quantitatively map the heterogeneous response of the airway to injury via its reduced wall compliance.


  • Open Access

    Assessing Lung Fibrosis with ML-Assisted Minimally Invasive OCT Imaging

    by Rebecca Steinberg, Jack Meehan, Doran Tavrow, Gopi Maguluri, John Grimble, Michael Primrose, Nicusor Iftimia

    This paper presents a combined optical coherence tomography (OCT) imaging/machine learning (ML) technique for real-time analysis of lung tissue morphology to determine the presence and level of invasiveness of idiopathic lung fibrosis (ILF). This is an important clinical problem as misdiagnosis is common, resulting in patient exposure to costly and invasive procedures and substantial use of healthcare resources. Therefore, biopsy is needed to confirm or rule out radiological findings. Videoscopic-assisted thoracoscopic wedge biopsy (VATS) under general anesthesia is typically necessary to obtain enough tissue to make an accurate diagnosis. This kind of biopsy involves the placement of several tubes through the chest wall, one of which is used to cut off a piece of lung to send for evaluation. The removed tissue is examined histopathologically by microscopy to confirm the presence and the pattern of fibrosis. However, VATS pulmonary biopsy can have multiple side effects, including inflammation, tissue morbidity, and severe bleeding, which further degrade the quality of life for the patient. Furthermore, the results are not immediately available, requiring tissue processing and analysis. Here, we report an initial attempt of using ML-assisted polarization sensitive OCT (PS-OCT) imaging for lung fibrosis assessment. This approach has been preliminarily tested on a rat model of lung fibrosis. Our preliminary results show that ML-assisted PS-OCT imaging can detect the presence of ILF with an average of 77% accuracy and 89% specificity.


  • Open Access

    High Sensitivity Singlet Oxygen Luminescence Sensor Using Computational Spectroscopy and Solid-State Detector

    by Tiffany C. Yu, Steve J. Davis, Mark T. Scimone, John Grimble, Gopi Maguluri, Sanjay Anand, Cheng-En Cheng, Edward Maytin, Xu Cao, Brian W. Pogue, et al.

    This paper presents a technique for high sensitivity measurement of singlet oxygen luminescence generated during photodynamic therapy (PDT) and ultraviolet (UV) irradiation on skin. The high measurement sensitivity is achieved by using a computational spectroscopy (CS) approach that provides improved photon detection efficiency compared to spectral filtering methodology. A solid-state InGaAs photodiode is used as the CS detector, which significantly reduces system cost and improves robustness compared to photomultiplier tubes. The spectral resolution enables high-accuracy determination and subtraction of photosensitizer fluorescence baseline without the need for time-gating. This allows for high sensitivity detection of singlet oxygen luminescence emission generated by continuous wave light sources, such as solar simulator sources and those commonly used in PDT clinics. The value of the technology is demonstrated during in vivo and ex vivo experiments that show the correlation of measured singlet oxygen with PDT treatment efficacy and the illumination intensity on the skin. These results demonstrate the potential use of the technology as a dosimeter to guide PDT treatment and as an analytical tool supporting the development of improved sunscreen products for skin cancer prevention.


  • Open Access

    Core Needle Biopsy Guidance Based on Tissue Morphology Assessment with AI-OCT Imaging

    by Gopi Maguluri, John Grimble, Aliana Caron, Ge Zhu, Savitri Krishnamurthy, Amanda McWatters, Gillian Beamer, Seung-Yi Lee, Nicusor Iftimia

    This paper presents a combined optical imaging/artificial intelligence (OI/AI) technique for the real-time analysis of tissue morphology at the tip of the biopsy needle, prior to collecting a biopsy specimen. This is an important clinical problem as up to 40% of collected biopsy cores provide low diagnostic value due to high adipose or necrotic content. Micron-scale-resolution optical coherence tomography (OCT) images can be collected with a minimally invasive needle probe and automatically analyzed using a computer neural network (CNN)-based AI software. The results can be conveyed to the clinician in real time and used to select the biopsy location more adequately. This technology was evaluated on a rabbit model of cancer. OCT images were collected with a hand-held custom-made OCT probe. Annotated OCT images were used as ground truth for AI algorithm training. The overall performance of the AI model was very close to that of the humans performing the same classification tasks. Specifically, tissue segmentation was excellent (~99% accuracy) and provided segmentation that closely mimicked the ground truth provided by the human annotations, while over 84% correlation accuracy was obtained for tumor and non-tumor classification.


  • Open Access

    Core Needle Biopsy Guidance Based on Tissue Morphology Assessment With AI-OCT Imaging

    by Gopi Maguluri, John Grimble, Aliana Caron, Ge Zhu, Savitri Krishnamurthy, Amanda McWatters, Gillian Beamer, Seung-Yi Lee, Nicusor Iftimia

    This paper presents a combined optical imaging/artificial intelligence (OI/AI) technique for real-time analysis of tissue morphology at the tip of the biopsy needle, prior collecting a biopsy specimen. This is an important clinical problem as up to 40% of the collected biopsy cores provide low diagnostic value due to high adipose or necrotic content. Micron-scale resolution optical coherence tomography (OCT) images can be collected with a minimally invasive needle probe and automatically analyzed by a computer neural network (CNN)-based AI software. The results can be conveyed to the clinician in real-time and used to select the biopsy location more adequately. This technology was evaluated on a rabbit model of cancer. OCT images were collected with a hand-held custom-made OCT probe. Annotated OCT images were used as ground truth for AI algorithm training. The overall performance of the AI model was very close to that of the humans performing the same classification tasks. Specifically, tissue segmentation was excellent (~99% accuracy) and provided segmentation that closely mimicked ground truth provided by the human annotations, while over 83% correlation accuracy was obtained for tumor and non-tumor classification.


  • Open Access

    Smart Steering Sleeve (S3): A Non-Intrusive and Integrative Sensing Platform for Driver Physiological Monitoring

    by Chuwei Ye, Wen Li, Zhaojian Li, Gopi Maguluri, John Grimble, Joshua Bonatt, Jacob Miske, Nicusor Iftimia, Shaoting Lin, Michele Grimm

    Driving is a ubiquitous activity that requires both motor skills and cognitive focus. These aspects become more problematic for some seniors, who have underlining medical conditions and tend to lose some of these capabilities. Therefore, driving can be used as a controlled environment for the frequent, non-intrusive monitoring of bio-physical and cognitive status within drivers. Such information can then be utilized for enhanced assistive vehicle controls and/or driver health monitoring. In this paper, we present a novel multi-modal smart steering sleeve (S3) system with an integrated sensing platform that can non-intrusively and continuously measure a driver’s physiological signals, including electrodermal activity (EDA), electromyography (EMG), and hand pressure. The sensor suite was developed by combining low-cost interdigitated electrodes with a piezoresistive force sensor on a single, flexible polymer substrate. Comprehensive characterizations on the sensing modalities were performed with promising results demonstrated. The sweat-sensing unit (SSU) for EDA monitoring works under a 100 Hz alternative current (AC) source. The EMG signal acquired by the EMG-sensing unit (EMGSU) was amplified to within 5 V. The force-sensing unit (FSU) for hand pressure detection has a range of 25 N. This flexible sensor was mounted on an off-the-shelf steering wheel sleeve, making it an add-on system that can be installed on any existing vehicles for convenient and wide-coverage driver monitoring. A cloud-based communication scheme was developed for the ease of data collection and analysis. Sensing platform development, performance, and limitations, as well as other potential applications, are discussed in detail in this paper.