Giulia Marcer
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Giulia Marcer has a total of 159 co-authors. Here are the top co-authors by number of shared publications:
- Davide Rigamonti
Institute for Plasma Science and Technology, National Research Council 2 , Milan 20125
16 shared publications - Marco Tardocchi
Institute for Plasma Science and Technology, National Research Council 2 , Milan 20125
15 shared publications - Marica Rebai
Institute for Plasma Science and Technology, National Research Council 2 , Milan 20125
15 shared publications - Massimo Nocente
Department of Physics, University of Milano-Bicocca 1 , Milan 20126
13 shared publications - Giuseppe Gorini
Department of Physics, University of Milano-Bicocca 1 , Milan 20126
12 shared publications - Andrea Dal Molin
Department of Physics, University of Milano-Bicocca 1 , Milan 20126
11 shared publications
Latest Publications
- Open Access
- 5 November 2026
- Published by Elsevier in Fusion Engineering and Design
- Vol. 234
Monte-Carlo simulation of prompt gamma-ray background in the ITER radial gamma-ray spectrometer
- 5 November 2026
- Published by Elsevier in Fusion Engineering and Design
- Vol. 234
Open AccessMonte-Carlo simulation of prompt gamma-ray background in the ITER radial gamma-ray spectrometer
- Open Access
- 1 November 2026
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 97 (11)
Impact of instrumental effects and target thickness on the SPARC magnetic proton recoil spectrometer response function
The SPARC tokamak aims to demonstrate net fusion power gain in tokamaks (Q-fus > 1). To measure neutron emission, a neutron spectrometer based on the magnetic proton recoil technique is being developed. This diagnostic operates by converting collimated neutrons into recoil protons through elastic scattering on a polyethylene target. The recoiled protons are then separated based on their momentum by a magnetic field and subsequently detected by a hodoscope composed of plastic scintillation detectors coupled to photomultiplier tubes. This allows neutron energies in the 2–20 MeV range to be discriminated, though only neutrons in a narrower energy window (±25% around the selected central energy) can be measured. The instrument will contribute to the determination of the total fusion power and provide information on plasma parameters such as ion temperature and the presence of non-thermal fuel ions. In this study, the design rationale of the hodoscope is presented and the main instrumental effects that govern proton collection are characterized. The hodoscope is divided into three regions with different channel widths, depths, and lengths, jointly optimized to satisfy three coupled physical requirements: sufficient energy resolution at the 14.1 MeV DT peak, full proton containment up to 18.75 MeV, and limitation of the background through minimization of the detector volume. Three correction factors are evaluated through dedicated simulations: the vertical signal loss due to protons falling outside the scintillator rod length, the cross-talk between adjacent channels, and the background contribution per channel. A correction scheme combining all three factors is presented.
- 1 November 2026
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 97 (11)
Open AccessImpact of instrumental effects and target thickness on the SPARC magnetic proton recoil spectrometer response function
The SPARC tokamak aims to demonstrate net fusion power gain in tokamaks (Q-fus > 1). To measure neutron emission, a neutron spectrometer based on the magnetic proton recoil technique is being developed. This diagnostic operates by converting collimated neutrons into recoil protons through elastic scattering on a polyethylene target. The recoiled protons are then separated based on their momentum by a magnetic field and subsequently detected by a hodoscope composed of plastic scintillation detectors coupled to photomultiplier tubes. This allows neutron energies in the 2–20 MeV range to be discriminated, though only neutrons in a narrower energy window (±25% around the selected central energy) can be measured. The instrument will contribute to the determination of the total fusion power and provide information on plasma parameters such as ion temperature and the presence of non-thermal fuel ions. In this study, the design rationale of the hodoscope is presented and the main instrumental effects that govern proton collection are characterized. The hodoscope is divided into three regions with different channel widths, depths, and lengths, jointly optimized to satisfy three coupled physical requirements: sufficient energy resolution at the 14.1 MeV DT peak, full proton containment up to 18.75 MeV, and limitation of the background through minimization of the detector volume. Three correction factors are evaluated through dedicated simulations: the vertical signal loss due to protons falling outside the scintillator rod length, the cross-talk between adjacent channels, and the background contribution per channel. A correction scheme combining all three factors is presented.
- Open Access
- 28 July 2026
- Published by Elsevier in SSRN Electronic Journal
Monte-Carlo Simulation of Gamma-Ray Background in the ITER Radial Gamma-Ray Spectrometer
The ITER Radial Gamma Ray Spectrometer (RGRS) is a high-performance diagnostic instrument designed to measure gamma radiation emitted by the plasma in the ITER tokamak fusion reactor. RGRS will have three dedicated radial lines of sight plus one shared with the Radial Neutron Camera, and uses LaBr3 scintillator detectors to record gamma-ray spectra for the study of fast ions, the monitoring of runaway electrons, and the measurement of fusion power. A critical challenge in the operation of RGRS will be the characterisation of the gamma-ray background reaching the detectors, which is required to improve diagnostic design, correctly interpret detector spectra and assess diagnostic performance. This work presents MCNP Monte Carlo simulations of the gamma-ray background in RGRS, employing a two-step simulation approach to isolate and quantify the dominant background contributions. Results indicate that neutron-induced gamma-rays from the central column will be the primary background source, exceeding by nearly one order of magnitude all other contributions along the line of sight, with direct implications for the detector count rate and the signal-to-background ratio during full-power ITER operation.
- 28 July 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessMonte-Carlo Simulation of Gamma-Ray Background in the ITER Radial Gamma-Ray Spectrometer
The ITER Radial Gamma Ray Spectrometer (RGRS) is a high-performance diagnostic instrument designed to measure gamma radiation emitted by the plasma in the ITER tokamak fusion reactor. RGRS will have three dedicated radial lines of sight plus one shared with the Radial Neutron Camera, and uses LaBr3 scintillator detectors to record gamma-ray spectra for the study of fast ions, the monitoring of runaway electrons, and the measurement of fusion power. A critical challenge in the operation of RGRS will be the characterisation of the gamma-ray background reaching the detectors, which is required to improve diagnostic design, correctly interpret detector spectra and assess diagnostic performance. This work presents MCNP Monte Carlo simulations of the gamma-ray background in RGRS, employing a two-step simulation approach to isolate and quantify the dominant background contributions. Results indicate that neutron-induced gamma-rays from the central column will be the primary background source, exceeding by nearly one order of magnitude all other contributions along the line of sight, with direct implications for the detector count rate and the signal-to-background ratio during full-power ITER operation.
- Open Access
- 1 May 2026
- Published by IOP Publishing in Plasma Physics and Controlled Fusion
- Vol. 68 (5) , 055032
Operational domain estimation of a gamma-ray spectrometer for deuterium–tritium fusion power measurement at ITER
ITER will be equipped with two types of diagnostics for fusion power measurement in deuterium–tritium plasmas: neutron flux monitors and neutron cameras, both absolutely counting the 14 MeV neutrons emitted by the D(T, 4 He)n reaction. The radial gamma-ray spectrometer (RGRS), though, has recently been considered as an additional fusion power diagnostic, detecting 17 MeV gamma-rays emitted by the radiative D(T, 5 He) γ channel of the DT reaction. This work describes the RGRS performance by determining the upper limit of its operational domain, strictly correlated with the expected background intensity and resulting between 2.6 ⋅ 10 17 neutrons per second and 3.2 ⋅ 10 18 neutrons per second. Based on this assessment, design optimization are introduced to fit the RGRS performances to the ITER requirements for safety-relevant fusion power measurements, for which the required operational range is between 2.4 ⋅ 10 19 neutrons per second and 3.2 ⋅ 10 20 neutrons per second. The expected different energy ranges covered by signal and background are exploited with the employment of a proper gamma-ray attenuator, allowing to widen and shift the RGRS operational domain toward the most relevant, high power plasma scenarios.
- 1 May 2026
- Published by IOP Publishing in Plasma Physics and Controlled Fusion
- Vol. 68 (5) , 055032
Open AccessOperational domain estimation of a gamma-ray spectrometer for deuterium–tritium fusion power measurement at ITER
ITER will be equipped with two types of diagnostics for fusion power measurement in deuterium–tritium plasmas: neutron flux monitors and neutron cameras, both absolutely counting the 14 MeV neutrons emitted by the D(T, 4 He)n reaction. The radial gamma-ray spectrometer (RGRS), though, has recently been considered as an additional fusion power diagnostic, detecting 17 MeV gamma-rays emitted by the radiative D(T, 5 He) γ channel of the DT reaction. This work describes the RGRS performance by determining the upper limit of its operational domain, strictly correlated with the expected background intensity and resulting between 2.6 ⋅ 10 17 neutrons per second and 3.2 ⋅ 10 18 neutrons per second. Based on this assessment, design optimization are introduced to fit the RGRS performances to the ITER requirements for safety-relevant fusion power measurements, for which the required operational range is between 2.4 ⋅ 10 19 neutrons per second and 3.2 ⋅ 10 20 neutrons per second. The expected different energy ranges covered by signal and background are exploited with the employment of a proper gamma-ray attenuator, allowing to widen and shift the RGRS operational domain toward the most relevant, high power plasma scenarios.
- Open Access
- 16 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 54 (6) , 2569-2574
MCNP-Based Characterization of the High-Energy Background in Gamma Ray Spectrometers for Fusion Power Measurements in DT Plasmas
A new method for measuring fusion power in DT plasmas using high-energy gamma spectroscopy was recently demonstrated at JET. Besides a $10^{5}$ times more intense background at lower energies, a gamma background in the signal energy region was observed but not identified, contributing to higher uncertainty on the measurements. Due to the rarity of the event considered and the complex geometry of the tokamak, a new method to simulate the gamma background at high energy using MCNP was required. In this work, a combination of variance reduction techniques was developed by analyzing the nature of the background and validated by comparing simulation results to experimental data. The library comparison showed that ENDF/B-VIII is the library that better describes the shape of the high-energy gamma background, although the simulated component is 2.5 times higher than experimental data. Results using Fendl 3.1d nuclear library presented reduced discrepancy in magnitude, albeit with a distinct spectral distribution.
- 16 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 54 (6) , 2569-2574
Open AccessMCNP-Based Characterization of the High-Energy Background in Gamma Ray Spectrometers for Fusion Power Measurements in DT Plasmas
A new method for measuring fusion power in DT plasmas using high-energy gamma spectroscopy was recently demonstrated at JET. Besides a $10^{5}$ times more intense background at lower energies, a gamma background in the signal energy region was observed but not identified, contributing to higher uncertainty on the measurements. Due to the rarity of the event considered and the complex geometry of the tokamak, a new method to simulate the gamma background at high energy using MCNP was required. In this work, a combination of variance reduction techniques was developed by analyzing the nature of the background and validated by comparing simulation results to experimental data. The library comparison showed that ENDF/B-VIII is the library that better describes the shape of the high-energy gamma background, although the simulated component is 2.5 times higher than experimental data. Results using Fendl 3.1d nuclear library presented reduced discrepancy in magnitude, albeit with a distinct spectral distribution.
- Open Access
- 7 March 2026
- Published by Elsevier in SSRN Electronic Journal
Optimization of diamond detectors and neutron lines ofsight for ion temperature profile reconstruction on SPARC neutron camera
SPARC is a compact, high-field Deuterium-Tritium (DT) tokamak currently being assembled in Devens, MA, USA, by Commonwealth Fusion Systems (CFS). The device aims to reach fusion breakeven, targeting a plasma gain (Q) greater than 1 and producing up to 140 MW of fusion power (PFUS). It will feature a poloidal neutron camera (NCAM) designed to provide energy, time, and space-resolved measurements of neutron emission. The system consists of multiple detectors located at the endpoints of collimated lines of sight (LOS). For high-power DT operations, the NCAM adopts single crystal Chemical Vapor Deposition diamond detectors as its baseline technology, selected for their radiation hardness, ∼ 1% intrinsic energy resolution at14MeV, high count-rate capability, and compact size. This work focuses on optimizing the layout of the NCAM diamond detectors to support ion temperature profile reconstruction over a broad range of neutron fluxes expected during DT plasmas. Specifically, it investigates the optimal number and size of diamond pixels at the LOS endpoints to support both inter-shot analysis and potential real-time applications. Synthetic data and an inversion algorithm are developed and applied to the reference SPARC plasma scenario. To assess the reconstruction capability of different NCAMconfigurations with the developed algorithm, the reference scenario is perturbed using heuristic variations, designed to test robustness against plasma shape and position changes, as well as Poisson noise. The results demonstrate that multiple design configurations satisfy the required time and energy resolution for ion temperature profile reconstruction. A proposed setup for DT operations is identified, capable of supporting both early-phase experiments (1 MW < PFUS < 60MW) and later high-power campaigns (PFUS < 140 MW).
- 7 March 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessOptimization of diamond detectors and neutron lines ofsight for ion temperature profile reconstruction on SPARC neutron camera
SPARC is a compact, high-field Deuterium-Tritium (DT) tokamak currently being assembled in Devens, MA, USA, by Commonwealth Fusion Systems (CFS). The device aims to reach fusion breakeven, targeting a plasma gain (Q) greater than 1 and producing up to 140 MW of fusion power (PFUS). It will feature a poloidal neutron camera (NCAM) designed to provide energy, time, and space-resolved measurements of neutron emission. The system consists of multiple detectors located at the endpoints of collimated lines of sight (LOS). For high-power DT operations, the NCAM adopts single crystal Chemical Vapor Deposition diamond detectors as its baseline technology, selected for their radiation hardness, ∼ 1% intrinsic energy resolution at14MeV, high count-rate capability, and compact size. This work focuses on optimizing the layout of the NCAM diamond detectors to support ion temperature profile reconstruction over a broad range of neutron fluxes expected during DT plasmas. Specifically, it investigates the optimal number and size of diamond pixels at the LOS endpoints to support both inter-shot analysis and potential real-time applications. Synthetic data and an inversion algorithm are developed and applied to the reference SPARC plasma scenario. To assess the reconstruction capability of different NCAMconfigurations with the developed algorithm, the reference scenario is perturbed using heuristic variations, designed to test robustness against plasma shape and position changes, as well as Poisson noise. The results demonstrate that multiple design configurations satisfy the required time and energy resolution for ion temperature profile reconstruction. A proposed setup for DT operations is identified, capable of supporting both early-phase experiments (1 MW < PFUS < 60MW) and later high-power campaigns (PFUS < 140 MW).
- Open Access
- 3 March 2026
- Published by Elsevier in SSRN Electronic Journal
Development of Neutron Attenuators for Gamma Ray Measurements in DT fusion experiments
The gamma rays emitted by the T(D,γ)5He fusion reaction have been measured at the FNG neutron irradiation facility in ENEA-Frascati by using a large 3”x3” LaBr3 scintillator crystal. Since the gamma ray emission probability by the DT reaction is 10-5 lower with respect to the main fusion reaction channel T(D,n)4He a neutron attenuator is needed. In this paper we present the design of a neutron attenuator based on a combination of different materials. The neutron attenuator performances have been studied with a series of MCNP simulations benchmarked with an experiment performed with a 137Cs gamma ray source. The analysis of the experimental results shows a gamma component in the region of interest that is compatible with the T(D,γ)5He reaction. Although the results obtained at FNG indicate that the gamma rays emitted by the T(D,γ)5He can be measured with the present set-up, they also show that an improvement of the experimental set-up is needed. An analysis of the background induced by the scattered neutrons is provided and improvements to the neutron attenuator are proposed.
- 3 March 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessDevelopment of Neutron Attenuators for Gamma Ray Measurements in DT fusion experiments
The gamma rays emitted by the T(D,γ)5He fusion reaction have been measured at the FNG neutron irradiation facility in ENEA-Frascati by using a large 3”x3” LaBr3 scintillator crystal. Since the gamma ray emission probability by the DT reaction is 10-5 lower with respect to the main fusion reaction channel T(D,n)4He a neutron attenuator is needed. In this paper we present the design of a neutron attenuator based on a combination of different materials. The neutron attenuator performances have been studied with a series of MCNP simulations benchmarked with an experiment performed with a 137Cs gamma ray source. The analysis of the experimental results shows a gamma component in the region of interest that is compatible with the T(D,γ)5He reaction. Although the results obtained at FNG indicate that the gamma rays emitted by the T(D,γ)5He can be measured with the present set-up, they also show that an improvement of the experimental set-up is needed. An analysis of the background induced by the scattered neutrons is provided and improvements to the neutron attenuator are proposed.
- Open Access
- 20 January 2026
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 37 (6)
Particle discrimination capabilities of lanthanum halide scintillators
In the last few decades, lanthanum halide scintillators such as LaBr3(Ce), LaBr3(Ce+Sr) and LaCl3(Ce) have been extensively used for gamma ray spectroscopy measurements. They offer excellent energy resolution (about 3-4 % at 662keV) and fast scintillation time, allowing high counting rate measurements. These scintillators find applications in many research fields such as nuclear physics, astrophysics, nuclear fusion and nuclear medicine. More recently, thanks to the exploitation of the n-35Cl nuclear reaction channel, LaCl3(Ce) crystals have been used as neutron spectrometers. This opened up the opportunity to explore pulse shape discrimination algorithms for enabling the neutron/gamma discrimination. In this work, an innovative algorithm for particle discrimination applied to lanthanum halide scintillators is presented. The effectiveness of the algorithm has been demonstrated first on the intrinsic radioactivity measurement of the crystals, which is characterized by gamma ray emissions from 138La decay and alpha decays due to actinides contamination, and then with fast neutrons. The particle discrimination feature allows for a better description of the intrinsic activity of the crystal and improved background suppression when performing gamma ray spectroscopy measurements in low cross-section measurements or in a mixed gamma-neutron radiation field.
- 20 January 2026
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 37 (6)
Open AccessParticle discrimination capabilities of lanthanum halide scintillators
In the last few decades, lanthanum halide scintillators such as LaBr3(Ce), LaBr3(Ce+Sr) and LaCl3(Ce) have been extensively used for gamma ray spectroscopy measurements. They offer excellent energy resolution (about 3-4 % at 662keV) and fast scintillation time, allowing high counting rate measurements. These scintillators find applications in many research fields such as nuclear physics, astrophysics, nuclear fusion and nuclear medicine. More recently, thanks to the exploitation of the n-35Cl nuclear reaction channel, LaCl3(Ce) crystals have been used as neutron spectrometers. This opened up the opportunity to explore pulse shape discrimination algorithms for enabling the neutron/gamma discrimination. In this work, an innovative algorithm for particle discrimination applied to lanthanum halide scintillators is presented. The effectiveness of the algorithm has been demonstrated first on the intrinsic radioactivity measurement of the crystals, which is characterized by gamma ray emissions from 138La decay and alpha decays due to actinides contamination, and then with fast neutrons. The particle discrimination feature allows for a better description of the intrinsic activity of the crystal and improved background suppression when performing gamma ray spectroscopy measurements in low cross-section measurements or in a mixed gamma-neutron radiation field.
- Open Access
- 24 July 2025
- Published by IOP Publishing in Nuclear Fusion
- Vol. 65 (8) , 086036
Absolute measurement of the deuterium–tritium reaction gamma-ray emission in magnetic confinement fusion plasmas
The Joint European Torus performed its second deuterium–tritium (DT) campaign at the end of 2021. This unique opportunity was exploited to carry out the first absolute measurement in a magnetic confinement plasma of the total gamma-ray emission from the DT fusion reaction, namely the less probable (branching ratio = 2.4 ⋅ 10 − 5 ) electromagnetic counterpart of the main neutronic decay channel. A single line of sight gamma-ray spectrometer was employed for this purpose. Numerous challenges had to be addressed in order to pursue the goal: (1) characterise the detector beamline and its detection efficiency in absolute terms, (2) dealing with an extended and non-uniform source, (3) suppress the intense neutron background, (4) handle the high event rate at the detector and (5) discriminate between signal and background in the acquired energy spectrum. This paper describes the procedure adopted for measuring the total DT gamma-ray yield of 96 DT plasma discharges with event rates below hundred kHz. The results were validated through a comparison with the neutron yields provided by the Joint European Torus neutron monitors, revealing an outstanding 0.983 linear correlation. This work proves the feasibility to employ the gamma-ray emission of the DT fusion reaction as a secondary indicator for measuring the fusion power in magnetically confined DT plasmas.
- 24 July 2025
- Published by IOP Publishing in Nuclear Fusion
- Vol. 65 (8) , 086036
Open AccessAbsolute measurement of the deuterium–tritium reaction gamma-ray emission in magnetic confinement fusion plasmas
The Joint European Torus performed its second deuterium–tritium (DT) campaign at the end of 2021. This unique opportunity was exploited to carry out the first absolute measurement in a magnetic confinement plasma of the total gamma-ray emission from the DT fusion reaction, namely the less probable (branching ratio = 2.4 ⋅ 10 − 5 ) electromagnetic counterpart of the main neutronic decay channel. A single line of sight gamma-ray spectrometer was employed for this purpose. Numerous challenges had to be addressed in order to pursue the goal: (1) characterise the detector beamline and its detection efficiency in absolute terms, (2) dealing with an extended and non-uniform source, (3) suppress the intense neutron background, (4) handle the high event rate at the detector and (5) discriminate between signal and background in the acquired energy spectrum. This paper describes the procedure adopted for measuring the total DT gamma-ray yield of 96 DT plasma discharges with event rates below hundred kHz. The results were validated through a comparison with the neutron yields provided by the Joint European Torus neutron monitors, revealing an outstanding 0.983 linear correlation. This work proves the feasibility to employ the gamma-ray emission of the DT fusion reaction as a secondary indicator for measuring the fusion power in magnetically confined DT plasmas.
- Open Access
- 24 May 2025
- Published by Elsevier in Energy and AI
- Vol. 21
A machine learning case study in nuclear fusion: Assessment of the absolute deuterium-tritium fusion power of ITER with gamma-ray spectroscopy
- 24 May 2025
- Published by Elsevier in Energy and AI
- Vol. 21
Open AccessA machine learning case study in nuclear fusion: Assessment of the absolute deuterium-tritium fusion power of ITER with gamma-ray spectroscopy