Jolanta Biernat
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jolanta Biernat has a total of 47 co-authors. Here are the top co-authors by number of shared publications:
- Krzysztof Stanislaw Golba
Department of Electrocardiology and Heart Failure, Medical University of Silesia, 40-635 Katowice, Poland
9 shared publications - Rafal Gardas
Department of Electrocardiology and Heart Failure, Medical University of Silesia , Katowice
5 shared publications - Danuta Łoboda
Department of Electrocardiology and Heart Failure, Medical University of Silesia, 40-635 Katowice, Poland
4 shared publications - Michal Joniec
Department of Electrocardiology, Upper-Silesian Medical Centre in Katowice, 40-635 Katowice, Poland
4 shared publications - Sylwia Gładysz-Wańha
Department of Electrocardiology, Upper-Silesian Medical Centre in Katowice, 40-635 Katowice, Poland
4 shared publications - Anna Drzewiecka
Department of Electrocardiology, Upper-Silesian Medical Centre in Katowice, Ziolowa 45/47 Str., 40-635 Katowice, Poland
3 shared publications
Latest Publications
- Open Access
- 28 August 2026
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 15 (17) , 6639
Long-Term Mortality Following Transvenous Lead Extraction: Data from EXTRACT Registry
Background/Objective: The EXTRACT registry cohort of 504 patients undergoing transvenous lead extraction (TLE) has been previously reported in terms of periprocedural safety and short-term outcomes. Data on long-term mortality and its predictors in this population remain limited. The study aimed to identify risk factors for overall mortality at three years following TLE. Methods: This is a secondary, long-term follow-up analysis of the previously published EXTRACT registry cohort of 504 consecutive patients who underwent TLE between 2016 and 2022. We conducted a univariate analysis to predict mortality risk following TLE, followed by Cox regression with cross-validation to identify independent predictors of mortality over a 3-year follow-up period; Brier score assessed prediction accuracy for mortality; and decision curve analysis evaluated the clinical usefulness of the model. Results: Mortality data were completed for 487 patients at three-year follow-up. Long-term outcomes of TLE showed that patients with CIED infection (p = 0.0091), higher NYHA class (p < 0.0001), arterial hypertension (p = 0.0068), previous stroke (p = 0.0092), upgraded to condition pacing post-TLE (p = 0.0092), and higher CHA2DS2-VA score (p = 0.0026) had markedly higher mortality at three-year follow-up. Increased mortality was independently associated with estimated glomerular filtration rate (eGFR) and the CHA2DS2-VA score. Risk increased incrementally with each 1 mL/min/1.73 m2 decrease in eGFR (hazard ratio, 0.99; 95% CI, 0.98–0.99), and each 1-point increase in CHA2DS2-VA conferred a 12% higher mortality rate (hazard ratio, 1.12; 95% CI, 1.02–1.23). Conclusions: In this prospective registry, 3-year mortality after TLE was driven predominantly by baseline clinical risk rather than procedural factors. Renal dysfunction and a higher CHA2DS2-VA score independently predicted death, supporting the incorporation of kidney function and global vascular risk into pre-extraction assessment and post-extraction management.
- 28 August 2026
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 15 (17) , 6639
Open AccessLong-Term Mortality Following Transvenous Lead Extraction: Data from EXTRACT Registry
Background/Objective: The EXTRACT registry cohort of 504 patients undergoing transvenous lead extraction (TLE) has been previously reported in terms of periprocedural safety and short-term outcomes. Data on long-term mortality and its predictors in this population remain limited. The study aimed to identify risk factors for overall mortality at three years following TLE. Methods: This is a secondary, long-term follow-up analysis of the previously published EXTRACT registry cohort of 504 consecutive patients who underwent TLE between 2016 and 2022. We conducted a univariate analysis to predict mortality risk following TLE, followed by Cox regression with cross-validation to identify independent predictors of mortality over a 3-year follow-up period; Brier score assessed prediction accuracy for mortality; and decision curve analysis evaluated the clinical usefulness of the model. Results: Mortality data were completed for 487 patients at three-year follow-up. Long-term outcomes of TLE showed that patients with CIED infection (p = 0.0091), higher NYHA class (p < 0.0001), arterial hypertension (p = 0.0068), previous stroke (p = 0.0092), upgraded to condition pacing post-TLE (p = 0.0092), and higher CHA2DS2-VA score (p = 0.0026) had markedly higher mortality at three-year follow-up. Increased mortality was independently associated with estimated glomerular filtration rate (eGFR) and the CHA2DS2-VA score. Risk increased incrementally with each 1 mL/min/1.73 m2 decrease in eGFR (hazard ratio, 0.99; 95% CI, 0.98–0.99), and each 1-point increase in CHA2DS2-VA conferred a 12% higher mortality rate (hazard ratio, 1.12; 95% CI, 1.02–1.23). Conclusions: In this prospective registry, 3-year mortality after TLE was driven predominantly by baseline clinical risk rather than procedural factors. Renal dysfunction and a higher CHA2DS2-VA score independently predicted death, supporting the incorporation of kidney function and global vascular risk into pre-extraction assessment and post-extraction management.
- Open Access
- 10 June 2026
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 15 (12) , 4500
Left Atrial Appendage Thrombus and Dense Spontaneous Echo Contrast in Anticoagulated Atrial Fibrillation Patients Referred for Cardioversion: Beyond CHA2DS2-VASc and Cardiac Implantable Electronic Devices
Background/Objectives: Predictors of left atrial appendage thrombus (LAAT) in adequately anticoagulated patients with atrial fibrillation (AF) referred for direct current cardioversion (DCCV) remain insufficiently defined, particularly in populations with a high prevalence of cardiac implantable electronic devices (CIEDs). The aim of this study was to identify clinical and echocardiographic determinants of LAAT and/or dense spontaneous echocardiographic contrast (SEC) in patients with persistent AF referred for DCCV. Methods: This prospective observational study included 510 consecutive patients with persistent AF who had received at least 3 weeks of effective anticoagulation and underwent transthoracic and transesophageal echocardiography prior to elective DCCV. The primary endpoint was the presence of LAAT and/or dense SEC (Fatkin grade 3–4). Independent predictors were identified using multivariable logistic regression. Results: LAAT and/or dense SEC were detected in 192 patients (37.6%)—of whom 73 had overt LAAT, 19 had borderline LAAT, and the remainder had dense SEC (Fatkin grade 3–4). Independent predictors included lower left ventricular ejection fraction (OR 0.95 per 1% increase, 95% CI 0.94–0.97, p < 0.0001), reduced right ventricular fractional area change (OR 0.93 per 1% increase, 95% CI 0.91–0.94, p < 0.0001), larger left atrial area (OR 1.05 per 1 cm2 increase, 95% CI 1.01–1.09, p = 0.011), and female sex (OR 1.78, 95% CI 1.14–2.79, p = 0.012). Moderate or greater mitral regurgitation was associated with a lower risk (OR 0.50, 95% CI 0.30–0.82, p = 0.007). The CHA2DS2-VASc score and the presence of right ventricular leads were not independently associated with LAAT/SEC. The model showed good discrimination (AUC 0.81, 95% CI 0.77–0.84). Conclusions: In anticoagulated patients with persistent AF, LAAT and/or dense SEC remain common and are primarily driven by echocardiographic markers of biventricular dysfunction and left atrial remodeling rather than by traditional clinical risk scores or the presence of cardiac devices.
- 10 June 2026
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 15 (12) , 4500
Open AccessLeft Atrial Appendage Thrombus and Dense Spontaneous Echo Contrast in Anticoagulated Atrial Fibrillation Patients Referred for Cardioversion: Beyond CHA2DS2-VASc and Cardiac Implantable Electronic Devices
Background/Objectives: Predictors of left atrial appendage thrombus (LAAT) in adequately anticoagulated patients with atrial fibrillation (AF) referred for direct current cardioversion (DCCV) remain insufficiently defined, particularly in populations with a high prevalence of cardiac implantable electronic devices (CIEDs). The aim of this study was to identify clinical and echocardiographic determinants of LAAT and/or dense spontaneous echocardiographic contrast (SEC) in patients with persistent AF referred for DCCV. Methods: This prospective observational study included 510 consecutive patients with persistent AF who had received at least 3 weeks of effective anticoagulation and underwent transthoracic and transesophageal echocardiography prior to elective DCCV. The primary endpoint was the presence of LAAT and/or dense SEC (Fatkin grade 3–4). Independent predictors were identified using multivariable logistic regression. Results: LAAT and/or dense SEC were detected in 192 patients (37.6%)—of whom 73 had overt LAAT, 19 had borderline LAAT, and the remainder had dense SEC (Fatkin grade 3–4). Independent predictors included lower left ventricular ejection fraction (OR 0.95 per 1% increase, 95% CI 0.94–0.97, p < 0.0001), reduced right ventricular fractional area change (OR 0.93 per 1% increase, 95% CI 0.91–0.94, p < 0.0001), larger left atrial area (OR 1.05 per 1 cm2 increase, 95% CI 1.01–1.09, p = 0.011), and female sex (OR 1.78, 95% CI 1.14–2.79, p = 0.012). Moderate or greater mitral regurgitation was associated with a lower risk (OR 0.50, 95% CI 0.30–0.82, p = 0.007). The CHA2DS2-VASc score and the presence of right ventricular leads were not independently associated with LAAT/SEC. The model showed good discrimination (AUC 0.81, 95% CI 0.77–0.84). Conclusions: In anticoagulated patients with persistent AF, LAAT and/or dense SEC remain common and are primarily driven by echocardiographic markers of biventricular dysfunction and left atrial remodeling rather than by traditional clinical risk scores or the presence of cardiac devices.
- Open Access
- 4 February 2026
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 15 (3) , 1216
Transvenous Lead Extraction Complicated by Lead Breakage: A Predictive Model Based on Analysis of the EXTRACT Registry
Background: The lead breakage (LB) during transvenous lead extraction (TLE) increases procedural complexity, increases the risk of complications, and decreases procedural efficiency. This study aimed to identify protective and risk factors for the breakage of cardiac electronic device leads during extraction. Methods: Data were sourced from the EXTRACT prospective registry for TLE procedures conducted between January 2016 and June 2025. A total of 702 consecutive TLE procedures involving 1375 leads were enrolled. Multivariate logistic regression was used to identify independent protective and risk factors and develop a model to predict the occurrence of LB during TLE. Results: In the analysed group, 56 (7.98%) of 702 TLE procedures were disrupted by the breakage of at least one lead. The model showed a lower lead breakage rate in procedures when an atrial lead was simultaneously extracted, a locking stylet was used, and when the procedure was conducted in older patients or those who had undergone prior cardiac surgery. Higher risk of LB was proven in the following cases: the extraction of leads implanted a long time ago; the extraction of VDD-type leads; the extraction of abandoned leads; extraction during a prolonged procedure. Occurrence of lead breakage may lead to pericardial effusion requiring intervention, acute kidney injury, or leaving remnants of the leads. Conclusions: Lead breakage is an underestimated procedural difficulty that can occur during transvenous lead extraction. In this study, several clinical and procedural variables were independently associated with lead breakage. Abandoned leads, VDD leads, and prolonged procedure time were associated with increased risk. In contrast, older age, use of a locking stylet, atrial lead extraction, prior cardiac surgery, and later year of implantation demonstrated independent protective associations.
- 4 February 2026
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 15 (3) , 1216
Open AccessTransvenous Lead Extraction Complicated by Lead Breakage: A Predictive Model Based on Analysis of the EXTRACT Registry
Background: The lead breakage (LB) during transvenous lead extraction (TLE) increases procedural complexity, increases the risk of complications, and decreases procedural efficiency. This study aimed to identify protective and risk factors for the breakage of cardiac electronic device leads during extraction. Methods: Data were sourced from the EXTRACT prospective registry for TLE procedures conducted between January 2016 and June 2025. A total of 702 consecutive TLE procedures involving 1375 leads were enrolled. Multivariate logistic regression was used to identify independent protective and risk factors and develop a model to predict the occurrence of LB during TLE. Results: In the analysed group, 56 (7.98%) of 702 TLE procedures were disrupted by the breakage of at least one lead. The model showed a lower lead breakage rate in procedures when an atrial lead was simultaneously extracted, a locking stylet was used, and when the procedure was conducted in older patients or those who had undergone prior cardiac surgery. Higher risk of LB was proven in the following cases: the extraction of leads implanted a long time ago; the extraction of VDD-type leads; the extraction of abandoned leads; extraction during a prolonged procedure. Occurrence of lead breakage may lead to pericardial effusion requiring intervention, acute kidney injury, or leaving remnants of the leads. Conclusions: Lead breakage is an underestimated procedural difficulty that can occur during transvenous lead extraction. In this study, several clinical and procedural variables were independently associated with lead breakage. Abandoned leads, VDD leads, and prolonged procedure time were associated with increased risk. In contrast, older age, use of a locking stylet, atrial lead extraction, prior cardiac surgery, and later year of implantation demonstrated independent protective associations.
- Open Access
- 9 January 2026
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 37 (3) , 493-500
Symptomatic Deep Venous Thrombosis of the Upper Extremity Following Transvenous Lead Extraction, Data From EXTRACT Registry
Background: Venous thrombosis occurring after TLE procedures is a fairly common but poorly described complication and requires further investigation into its causes. Aim: The aim of this study was to identify independent predictors of UEDVT occurrence after TLE procedures. Methods: We analyzed data from 504 transvenous lead extraction procedures performed in the hybrid surgery room of the Department of Electrocardiology and Heart Failure at the Medical University of Silesia, Katowice, Poland, between January 2016 and May 2022. All procedures were performed using mechanical‐only techniques. Results: In the analyzed period, as a result of 504 transvenous extraction procedures of cardiac implantable electronic device leads, 19 (3.8%) cases of symptomatic venous thrombosis of the upper extremity on the side of the procedure occurred. The mean age of patients who developed the complication was 65.8 ± 13.3 years, and 68.4% were men, which did not differ significantly from the general group. Based on variables selected in the univariate analysis, a logistic regression model of risk factors for UEDVT was calculated. These include a history of cancer disease in patients ( p = 0.0110), heart failure according to the Class IV NYHA scale ( p = 0.0397), advanced longest dwell time ( p = 0.0323), extraction of atrial lead ( p = 0.0368), and the use of mechanical non‐powered telescopic sheaths ( p = 0.0455). As protective factors were assessed, infectious indications for TLE ( p = 0.0288) and the highest platelet concentration ( p = 0.0448). Conclusions: Thrombosis is a relatively rare but serious complication. The precise selection of patients at risk of thrombosis after TLE may increase clinical success. It has been shown that an increased risk of thrombosis after TLE occurs in patients with a history of cancer, with heart failure in NYHA Class IV, and platelet concentration is low, in whom TLE is performed for noninfectious reasons, with the use of additional equipment like mechanical non‐powered telescopic sheaths.
- 9 January 2026
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 37 (3) , 493-500
Open AccessSymptomatic Deep Venous Thrombosis of the Upper Extremity Following Transvenous Lead Extraction, Data From EXTRACT Registry
Background: Venous thrombosis occurring after TLE procedures is a fairly common but poorly described complication and requires further investigation into its causes. Aim: The aim of this study was to identify independent predictors of UEDVT occurrence after TLE procedures. Methods: We analyzed data from 504 transvenous lead extraction procedures performed in the hybrid surgery room of the Department of Electrocardiology and Heart Failure at the Medical University of Silesia, Katowice, Poland, between January 2016 and May 2022. All procedures were performed using mechanical‐only techniques. Results: In the analyzed period, as a result of 504 transvenous extraction procedures of cardiac implantable electronic device leads, 19 (3.8%) cases of symptomatic venous thrombosis of the upper extremity on the side of the procedure occurred. The mean age of patients who developed the complication was 65.8 ± 13.3 years, and 68.4% were men, which did not differ significantly from the general group. Based on variables selected in the univariate analysis, a logistic regression model of risk factors for UEDVT was calculated. These include a history of cancer disease in patients ( p = 0.0110), heart failure according to the Class IV NYHA scale ( p = 0.0397), advanced longest dwell time ( p = 0.0323), extraction of atrial lead ( p = 0.0368), and the use of mechanical non‐powered telescopic sheaths ( p = 0.0455). As protective factors were assessed, infectious indications for TLE ( p = 0.0288) and the highest platelet concentration ( p = 0.0448). Conclusions: Thrombosis is a relatively rare but serious complication. The precise selection of patients at risk of thrombosis after TLE may increase clinical success. It has been shown that an increased risk of thrombosis after TLE occurs in patients with a history of cancer, with heart failure in NYHA Class IV, and platelet concentration is low, in whom TLE is performed for noninfectious reasons, with the use of additional equipment like mechanical non‐powered telescopic sheaths.
- Open Access
- 13 August 2024
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 26 (9)
Extraction of lumenless pacing leads from the His bundle and left bundle branch area: outcomes of the high-volume centre
Aims: The application of conduction system pacing (CSP) in clinical practice is growing, and the need for lead extraction will also increase. The data on outcomes and safety of CSP lead extraction are limited. The aim of this study was to assess procedural outcomes and safety of CSP lead removal. Methods and results: Forty-seven patients from the EXTRACT Registry with the indication for CSP lead removal were enrolled in the study conducted at the Department of Electrocardiology in Katowice, Poland. Extraction technique, outcomes, safety, and complication were evaluated. Forty-three (91.5%) leads were successfully removed, and 41 (87.2%) were removed with traction only. The dwelling time of 28 extracted leads was longer than 1 year, and the oldest extracted lead was implanted for 89 months. Seven (14.9%) leads were removed from the left bundle branch (LBB) area and 36 from the His bundle (HB). Transient complete atrioventricular block occurred during the procedure in two patients. In 27 out of 31 attempts (87.1%), new CSP leads were implanted: nine (33.3%) HB pacing leads and 18 (66.7%) LBB area pacing leads. Conclusion: The CSP lead extraction is safe and feasible with a low complication rate and high rate of CSP lead reimplantation.
- 13 August 2024
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 26 (9)
Open AccessExtraction of lumenless pacing leads from the His bundle and left bundle branch area: outcomes of the high-volume centre
Aims: The application of conduction system pacing (CSP) in clinical practice is growing, and the need for lead extraction will also increase. The data on outcomes and safety of CSP lead extraction are limited. The aim of this study was to assess procedural outcomes and safety of CSP lead removal. Methods and results: Forty-seven patients from the EXTRACT Registry with the indication for CSP lead removal were enrolled in the study conducted at the Department of Electrocardiology in Katowice, Poland. Extraction technique, outcomes, safety, and complication were evaluated. Forty-three (91.5%) leads were successfully removed, and 41 (87.2%) were removed with traction only. The dwelling time of 28 extracted leads was longer than 1 year, and the oldest extracted lead was implanted for 89 months. Seven (14.9%) leads were removed from the left bundle branch (LBB) area and 36 from the His bundle (HB). Transient complete atrioventricular block occurred during the procedure in two patients. In 27 out of 31 attempts (87.1%), new CSP leads were implanted: nine (33.3%) HB pacing leads and 18 (66.7%) LBB area pacing leads. Conclusion: The CSP lead extraction is safe and feasible with a low complication rate and high rate of CSP lead reimplantation.
- Open Access
- 25 October 2023
- Published by MDPI AG in Diagnostics
- Vol. 13 (21) , 3309
Relationships between Heart Chamber Morphology or Function and Respiratory Parameters in Patients with HFrEF and Various Types of Sleep-Disordered Breathing
Sleep-disordered breathing (SDB), i.e., central sleep apnea (CSA) and obstructive sleep apnea (OSA), affects the prognosis of patients with heart failure with reduced ejection fraction (HFrEF). The study assessed the relationships between heart chamber size or function and respiratory parameters in patients with HFrEF and various types of SDB. The 84 participants were patients aged 68.3 ± 8.4 years (80% men) with an average left ventricular ejection fraction (LVEF) of 25.5 ± 6.85% who qualified for cardioverter-defibrillator implantation with or without cardiac resynchronization therapy. SDB, defined by an apnea–hypopnea index (AHI) ≥ five events/hour, was diagnosed in 76 patients (90.5%); SDB was severe in 31 (36.9%), moderate in 26 (31.0%), and mild in 19 (22.6%). CSA was the most common type of SDB (64 patients, 76.2%). A direct proportional relationship existed only in the CSA group between LVEF or stroke volume (SV) and AHI (p = 0.02 and p = 0.07), and between LVEF or SV and the percentage of total sleep time spent with hemoglobin oxygen saturation < 90% (p = 0.06 and p = 0.07). In contrast, the OSA group was the only group in which right ventricle size showed a positive relationship with AHI (for basal linear dimension [RVD1] p = 0.06), mean duration of the respiratory event (for RVD1 p = 0.03, for proximal outflow diameter [RVOT proximal] p = 0.009), and maximum duration of respiratory event (for RVD1 p = 0.049, for RVOT proximal p = 0.006). We concluded that in HFrEF patients, SDB severity is related to LV systolic function and SV only in CSA, whereas RV size correlates primarily with apnea/hypopnea episode duration in OSA.
- 25 October 2023
- Published by MDPI AG in Diagnostics
- Vol. 13 (21) , 3309
Open AccessRelationships between Heart Chamber Morphology or Function and Respiratory Parameters in Patients with HFrEF and Various Types of Sleep-Disordered Breathing
Sleep-disordered breathing (SDB), i.e., central sleep apnea (CSA) and obstructive sleep apnea (OSA), affects the prognosis of patients with heart failure with reduced ejection fraction (HFrEF). The study assessed the relationships between heart chamber size or function and respiratory parameters in patients with HFrEF and various types of SDB. The 84 participants were patients aged 68.3 ± 8.4 years (80% men) with an average left ventricular ejection fraction (LVEF) of 25.5 ± 6.85% who qualified for cardioverter-defibrillator implantation with or without cardiac resynchronization therapy. SDB, defined by an apnea–hypopnea index (AHI) ≥ five events/hour, was diagnosed in 76 patients (90.5%); SDB was severe in 31 (36.9%), moderate in 26 (31.0%), and mild in 19 (22.6%). CSA was the most common type of SDB (64 patients, 76.2%). A direct proportional relationship existed only in the CSA group between LVEF or stroke volume (SV) and AHI (p = 0.02 and p = 0.07), and between LVEF or SV and the percentage of total sleep time spent with hemoglobin oxygen saturation < 90% (p = 0.06 and p = 0.07). In contrast, the OSA group was the only group in which right ventricle size showed a positive relationship with AHI (for basal linear dimension [RVD1] p = 0.06), mean duration of the respiratory event (for RVD1 p = 0.03, for proximal outflow diameter [RVOT proximal] p = 0.009), and maximum duration of respiratory event (for RVD1 p = 0.049, for RVOT proximal p = 0.006). We concluded that in HFrEF patients, SDB severity is related to LV systolic function and SV only in CSA, whereas RV size correlates primarily with apnea/hypopnea episode duration in OSA.
- Open Access
- 1 December 2022
- Published by Medical University of Lublin in Current Issues in Pharmacy and Medical Sciences
- Vol. 35 (4) , 219-223
Levosimendan protects against ischemia – reperfusion injury in the human heart muscle. A pilot study
The consequences of myocardial infarction (MI) are an increasing problem worldwide. Despite spectacular progress in the invasive treatment of ischemic heart disease, the ability to limit the ischemia-reperfusion (I/R) injury remains largely unrealized. Recent studies have shown that stimulation of opioid receptors may confer a cardioprotective effect against I/R injury. Levosimendan, the inodilator, is indicated for the short-term treatment of acutely decompensated heart failure. We tested the hypothesis that levosimendan may provide cardioprotection in the opioid-like mechanism in the human myocardium.
- 1 December 2022
- Published by Medical University of Lublin in Current Issues in Pharmacy and Medical Sciences
- Vol. 35 (4) , 219-223
Open AccessLevosimendan protects against ischemia – reperfusion injury in the human heart muscle. A pilot study
The consequences of myocardial infarction (MI) are an increasing problem worldwide. Despite spectacular progress in the invasive treatment of ischemic heart disease, the ability to limit the ischemia-reperfusion (I/R) injury remains largely unrealized. Recent studies have shown that stimulation of opioid receptors may confer a cardioprotective effect against I/R injury. Levosimendan, the inodilator, is indicated for the short-term treatment of acutely decompensated heart failure. We tested the hypothesis that levosimendan may provide cardioprotection in the opioid-like mechanism in the human myocardium.
- Open Access
- 27 September 2022
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 11 (19) , 5723
The Effects of His Bundle Pacing Compared to Classic Resynchronization Therapy in Patients with Pacing-Induced Cardiomyopathy
Pacing-induced cardiomyopathy (PICM) is among the most common right ventricular pacing complications. Upgrading to cardiac resynchronization therapy (CRT) is the recommended treatment option. Conduction system pacing with His bundle pacing (HBP) has the potential to restore synchronous ventricular activation and can be an alternative to biventricular pacing (BVP). Patients with PICM scheduled for a system upgrade to CRT were included in the prospective cohort study. Either HBP or BVP was used for CRT. Electrocardiographic, clinical, and echocardiographic measurements were recorded at baseline and six-month follow-up. HBP was successful in 44 of 53 patients (83%). Thirty-nine patients with HBP and 22 with BVP completed a 6-month follow-up. HBP led to a higher reduction in QRS duration than BVP, 118.3 ± 14.20 ms vs. 150.5 ± 18.64 ms, p < 0.0001. The improvement in New York Heart Association (NYHA) class by one or two was more common in patients with HBP than those with BiV (p = 0.04). Left ventricular ejection fraction (LVEF) improved in BVP patients from 32.9 ± 7.93% to 43.9 ± 8.07%, p < 0.0001, and in HBP patients from 34.9 ± 6.45% to 48.6 ± 7.73%, p < 0.0001. The improvement in LVEF was more considerable in HBP patients than in BVP patients, p = 0.019. The improvement in clinical outcomes and left ventricle reverse remodeling was more significant with HBP than BVP. HBP can be a valid alternative to BVP for upgrade procedures in PICM patients.
- 27 September 2022
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 11 (19) , 5723
Open AccessThe Effects of His Bundle Pacing Compared to Classic Resynchronization Therapy in Patients with Pacing-Induced Cardiomyopathy
Pacing-induced cardiomyopathy (PICM) is among the most common right ventricular pacing complications. Upgrading to cardiac resynchronization therapy (CRT) is the recommended treatment option. Conduction system pacing with His bundle pacing (HBP) has the potential to restore synchronous ventricular activation and can be an alternative to biventricular pacing (BVP). Patients with PICM scheduled for a system upgrade to CRT were included in the prospective cohort study. Either HBP or BVP was used for CRT. Electrocardiographic, clinical, and echocardiographic measurements were recorded at baseline and six-month follow-up. HBP was successful in 44 of 53 patients (83%). Thirty-nine patients with HBP and 22 with BVP completed a 6-month follow-up. HBP led to a higher reduction in QRS duration than BVP, 118.3 ± 14.20 ms vs. 150.5 ± 18.64 ms, p < 0.0001. The improvement in New York Heart Association (NYHA) class by one or two was more common in patients with HBP than those with BiV (p = 0.04). Left ventricular ejection fraction (LVEF) improved in BVP patients from 32.9 ± 7.93% to 43.9 ± 8.07%, p < 0.0001, and in HBP patients from 34.9 ± 6.45% to 48.6 ± 7.73%, p < 0.0001. The improvement in LVEF was more considerable in HBP patients than in BVP patients, p = 0.019. The improvement in clinical outcomes and left ventricle reverse remodeling was more significant with HBP than BVP. HBP can be a valid alternative to BVP for upgrade procedures in PICM patients.
- Open Access
- 15 September 2022
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 25 (2) , 546-553
Electromechanical factors associated with favourable outcome in cardiac resynchronization therapy
Aims: Electromechanical coupling in patients receiving cardiac resynchronization therapy (CRT) is not fully understood. Our aim was to determine the best combination of electrical and mechanical substrates associated with effective CRT.Methods and results: Sixty-two patients were prospectively enrolled from two centres. Patients underwent 12-lead electrocardiogram (ECG), cardiovascular magnetic resonance (CMR), echocardiography, and anatomo-electromechanical mapping (AEMM). Remodelling was measured as the end-systolic volume (ΔESV) decrease at 6 months. CRT was defined effective with ΔESV ≤ −15%. QRS duration (QRSd) was measured from ECG. Area strain was obtained from AEMM and used to derive systolic stretch index (SSI) and total left-ventricular mechanical time. Total left-ventricular activation time (TLVAT) and transeptal time (TST) were derived from AEMM and ECG. Scar was measured from CMR. Significant correlations were observed between ΔESV and TST [rho = 0.42; responder: 50 (20–58) vs. non-responder: 33 (8–44) ms], TLVAT [−0.68; 81 (73–97) vs. 112 (96–127) ms], scar [−0.27; 0.0 (0.0–1.2) vs. 8.7 (0.0–19.1)%], and SSI [0.41; 10.7 (7.1–16.8) vs. 4.2 (2.9–5.5)], but not QRSd [−0.13; 155 (140–176) vs. 167 (155–177) ms]. TLVAT and SSI were highly accurate in identifying CRT response [area under the curve (AUC) > 0.80], followed by scar (AUC > 0.70). Total left-ventricular activation time (odds ratio = 0.91), scar (0.94), and SSI (1.29) were independent factors associated with effective CRT. Subjects with SSI >7.9% and TLVAT <91 ms all responded to CRT with a median ΔESV ≈ −50%, while low SSI and prolonged TLVAT were more common in non-responders (ΔESV ≈ −5%).Conclusion: Electromechanical measurements are better associated with CRT response than conventional ECG variables. The absence of scar combined with high SSI and low TLVAT ensures effectiveness of CRT.
- 15 September 2022
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 25 (2) , 546-553
Open AccessElectromechanical factors associated with favourable outcome in cardiac resynchronization therapy
Aims: Electromechanical coupling in patients receiving cardiac resynchronization therapy (CRT) is not fully understood. Our aim was to determine the best combination of electrical and mechanical substrates associated with effective CRT.Methods and results: Sixty-two patients were prospectively enrolled from two centres. Patients underwent 12-lead electrocardiogram (ECG), cardiovascular magnetic resonance (CMR), echocardiography, and anatomo-electromechanical mapping (AEMM). Remodelling was measured as the end-systolic volume (ΔESV) decrease at 6 months. CRT was defined effective with ΔESV ≤ −15%. QRS duration (QRSd) was measured from ECG. Area strain was obtained from AEMM and used to derive systolic stretch index (SSI) and total left-ventricular mechanical time. Total left-ventricular activation time (TLVAT) and transeptal time (TST) were derived from AEMM and ECG. Scar was measured from CMR. Significant correlations were observed between ΔESV and TST [rho = 0.42; responder: 50 (20–58) vs. non-responder: 33 (8–44) ms], TLVAT [−0.68; 81 (73–97) vs. 112 (96–127) ms], scar [−0.27; 0.0 (0.0–1.2) vs. 8.7 (0.0–19.1)%], and SSI [0.41; 10.7 (7.1–16.8) vs. 4.2 (2.9–5.5)], but not QRSd [−0.13; 155 (140–176) vs. 167 (155–177) ms]. TLVAT and SSI were highly accurate in identifying CRT response [area under the curve (AUC) > 0.80], followed by scar (AUC > 0.70). Total left-ventricular activation time (odds ratio = 0.91), scar (0.94), and SSI (1.29) were independent factors associated with effective CRT. Subjects with SSI >7.9% and TLVAT <91 ms all responded to CRT with a median ΔESV ≈ −50%, while low SSI and prolonged TLVAT were more common in non-responders (ΔESV ≈ −5%).Conclusion: Electromechanical measurements are better associated with CRT response than conventional ECG variables. The absence of scar combined with high SSI and low TLVAT ensures effectiveness of CRT.