GCGabrielle Gomes Centenaro

Gabrielle Gomes Centenaro

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Gabrielle Gomes Centenaro has a total of 37 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Efficacy of In‐Office Bleaching Using 35% Hydrogen Peroxide in an Attachable Syringe Varying the Application Tip: A Double‐Blind Randomized Clinical Trial

    by Gabrielle Gomes Centenaro, Laryssa Mylenna Madruga Barbosa, Leticia Condolo, Marina Kravchychyn Cappelletti, Alessandro D. Loguercio

    Objective: This randomized clinical trial evaluated the bleaching efficacy (BE), absolute risk and intensity of tooth sensitivity (TS), gingival irritation (GI), and esthetic self‐perception (ES) of an in‐office bleaching gel with an attachable syringe using different application tips in a randomized, double‐blind (participant‐ and evaluator‐blinded) clinical trial. Materials and Methods: Forty‐five participants received hemi‐arch bleaching using an attached brush and a conventional tip, performed in two sessions with hydrogen peroxide 35%. BE was evaluated at baseline, weekly, and 1‐month post‐bleaching using a spectrophotometer (Δ E ab , Δ E 00 , and ΔWI D ) and shade guide units (ΔSGU). The absolute risk and intensity of TS and GI using a VAS. ES was assessed using the Orofacial Esthetic Scale. BE was analyzed using repeated‐measures ANOVA. TS and GI were evaluated using the McNemar test (absolute risk) or paired t ‐test (intensity and ES scores; α = 0.05). Results: BE was observed for both groups, with no statistical difference ( p > 0.05) across all parameters. The absolute and intensity of TS were comparable between brush and conventional tip ( p > 0.05). ES was improved after bleaching ( p < 0.05). Conclusion: The application tips showed equivalent bleaching efficacy and esthetic self‐perception, as well as similar tooth sensitivity and gingival irritation. Clinical Significance: The brush applicator tip preserved bleaching efficacy while minimizing the volume of gel applied to the tooth surface, making it a more sustainable alternative.

  • Open Access

    Adhesive-based protective strategies for enamel cracks during in-office bleaching and their effect on hydrogen peroxide penetration

    by Letícia Condolo, Laryssa Mylenna Madruga Barbosa, Gabrielle Gomes Centenaro, Taynara S Carneiro, Michael Willian Favoreto, Alessandro D. Loguercio

    Objectives: To evaluate hydrogen peroxide (HP) penetration in teeth with enamel cracks and to investigate if adhesive-based strategies can reduce its permeability without compromising bleaching efficacy (BE). Materials and methods: Fifty human premolars ( n = 10 per group) were allocated into five groups: unbleached sound teeth (control), bleached sound teeth, bleached teeth with enamel cracks without adhesive strategy (cracked enamel), and two groups with enamel cracks receiving adhesive protection prior to bleaching (three-step etch-and-rinse adhesive [3-stepER] and universal adhesive used in an etch-and-rinse strategy [UA-ER]). Enamel cracks were detected using transillumination and measured using ImageJ software. In the adhesive groups, phosphoric acid etching was followed by adhesive application before two bleaching sessions. HP penetration into the pulp chamber was quantified using UV–Vis spectrophotometry. Color was assessed at baseline and after 7 and 14 days using digital spectrophotometry. Final bleaching efficacy was calculated from the color change between baseline and day 14 (ΔE ab, ΔE 00 and ΔWI D ). Data were analyzed using one-way ANOVA followed by Tukey’s post hoc test (α = 0.05). Results: HP penetration differed among the bleached groups ( p < 0.05). The sound group showed the lowest HP levels (0.21 ± 0.06 µg mL⁻¹), whereas the cracked enamel (0.36 ± 0.23 µg mL⁻¹) and 3-stepER (0.32 ± 0.11 µg mL⁻¹) groups showed similar intermediate values. The UA-ER strategy showed the highest HP penetration (1.81 ± 0.34 µg mL⁻¹; p < 0.05). No significant differences in BE were observed among the bleached groups. Conclusions: Neither adhesive-based strategy provided a protective effect against HP diffusion in teeth with enamel cracks. The 3-stepER strategy did not reduce HP penetration compared with unprotected cracked enamel, whereas the UA-ER strategy resulted in significantly greater HP penetration, indicating an adhesive-dependent response. Clinical Relevance: The use of adhesive systems as a protective strategy during in-office bleaching may not effectively reduce HP diffusion in teeth with enamel cracks. Clinicians should exercise caution when adopting such approaches.

  • Effects of Overnight Whitening Pens on Hydrogen Peroxide Penetration, Color Change, and Enamel Surface Properties

    by Iara María Ersilia Lima De León, Laryssa Mylenna Madruga Barbosa, Gabrielle Gomes Centenaro, Mariana Evangelista Santos, Sônia Saeger Meireles, Alessandro D. Loguercio

    Objective: To evaluate hydrogen peroxide (HP) permeability into the pulp chamber, objective color change, and enamel surface morphology after overnight use of over‐the‐counter (OTC) whitening pens. Materials and Methods: Fifty sound premolars were assigned to five groups ( n = 10): control, Optic White Pen LED (OW), Colgate Luminous White Whitening Pen (LW), Equate Teeth Whitening Kit (EQ), and Whiteness Perfect 10% (WP). Fifteen molars were used for enamel surface analyses (microhardness and roughness). Products were applied for 8 h/day for 10 days. HP penetration (μg/mL) and color change (Δ E ab , Δ E 00 , and WI D ) were measured by spectrophotometer. Initial HP concentration and pH were determined by titration and pH meter. Data were analyzed using ANOVA ( α = 0.05). Results: EQ showed the highest HP concentration and the lowest pH. HP penetration was significantly higher for EQ and lowest for WP ( p < 0.05). No significant differences in Δ E ab and Δ E 00 were observed among products, while WI D increased over time in all groups. Enamel surface changes were similar, except for EQ, which showed reduced microhardness ( p < 0.05). Conclusions: Overnight OTC whitening pens showed comparable cumulative bleaching efficacy. However, EQ resulted in greater pulpal HP penetration and enamel softening. Clinical Significance: Prolonged overnight OTC whitening pen use may increase pulpal exposure and enamel softening risk, reinforcing cautious use and professional supervision.


  • Open Access

    Over-the-counter whitening strips: Evaluation of color change and hydrogen peroxide penetration into a pulp chamber

    by Emanuel Adriano Hul, Michael Willian Favoreto, Laryssa Mylenna Madruga Barbosa, Deisy Cristina Ferreira Cordeiro, Gabrielle Gomes Centenaro, Christiane Philippini Ferreira Borges, Alessandra Reis, Alessandro D. Loguercio


  • Efficacy of 35 % self-mixed hydrogen peroxide In-office bleaching with reduced application time: A single-blind randomized controlled trial

    by Gabrielle Gomes Centenaro, Deisy Cristina Ferreira Cordeiro, Maria Alice de Matos Rodrigues, Mariah Maluf Lenhani, Roberta Micheten Dias, Cristina Gómez Polo, Alessandra Reis, Alessandro D. Loguercio


  • Resin infiltration and in-office dental bleaching on different substrates: hydrogen peroxide penetration, color change, and enamel morphology– an in vitro study

    by Taynara S. Carneiro, Bruno Baracco, Michel Wendlinger, Michael Willian Favoreto, Gabriel Cochinski, Gabrielle Centenaro, Laura Ceballos, Alessandro D. Loguercio

    Objectives To evaluate the penetration of hydrogen peroxide into the pulp chamber, color change, and enamel morphology of human teeth with different substrates (sound and white spot), subjected to the application of a resin infiltration (RI) and in-office bleaching at different time intervals (immediately and 7 days after RI application). Materials and methods Fifty-four sound human premolars were randomly distributed into six groups (n = 9), all subdivided according to substrate (sound and white spot): bleaching with 35% hydrogen peroxide only (HP); RI followed by immediate bleaching (RI/HPi); and RI followed by bleaching after 7 days (RI/HP7d). The concentration of hydrogen peroxide (µg/mL) was measured by UV-Vis spectrophotometry, color change was evaluated using a digital spectrophotometer (ΔE00 and WID), and enamel surface morphology was analyzed by scanning electron microscopy (SEM) (α = 0.05). Results In the groups without RI (HP), teeth with white spot lesions showed approximately 40% greater hydrogen peroxide penetration than sound teeth (p = 0.15). RI significantly reduced this penetration, regardless of the substrate or bleaching time (p > 0.02). According to WID values, the groups treated with RI (RI/HPi and RI/HP7d) achieved a final color similar to that of sound enamel treated with 35% HP. Enamel morphology was more homogeneous in the groups that received resin infiltration. Conclusions The application of RI prior to in-office bleaching significantly reduced hydrogen peroxide penetration into the pulp chamber without compromising bleaching efficacy. In teeth with white spot lesions, it led to a final shade comparable to that of sound teeth and resulted in a more uniform enamel morphology. Clinical relevance Resin infiltration is an effective, minimally invasive approach for treating white spot lesions, improving bleaching outcomes and limiting hydrogen peroxide penetration.


  • Open Access

    Influence of Different Protocols on In‐Office Bleaching: Whiteness Difference and Hydrogen Peroxide Penetration

    by Deisy Cristina Ferreira Cordeiro, Gabrielle Gomes Centenaro, Michael Willian Favoreto, Maria Alice de Matos Rodrigues, Alessandra Reis, Alessandro Dourado Loguercio

    Objectives: To evaluate whiteness difference (WID) and hydrogen peroxide (HP) penetration into the pulp chamber in extracted teeth subjected to various in‐office application protocols.Materials and Methods: A total of 154 human premolars were randomly assigned to 11 groups (n = 14). The groups were divided into: Pola Office+ and Pola Rapid (SDI), and the following protocols: three applications of 8 min (3 × 8), two applications of 8 min (2 × 8), one application of 8 min (1 × 8), one application of 16 min (1 × 16), and one application of 24 min (1 × 24). These protocols were selected based on manufacturer recommendations and the aim of exploring simplified and alternative approaches applicable to clinical practice. One group served as a negative control. WID was assessed using a digital spectrophotometer before and after two sessions. HP concentration in the pulp chamber was measured using UV–Vis spectrophotometry. ANOVA two‐way and Tukey's and Dunnett's tests were used for data analysis.Results: Significant WID were observed after two sessions, with greater changes in the 2 × 8, 3 × 8, and 1 × 24 protocols (p < 0.001). Lower levels of peroxide penetration were found with shorter application, such as the 1 × 8 protocol, while higher levels were detected in the 3 × 8 protocol (p < 0.0001).Conclusion: Among the evaluated protocols, the 2 × 8‐min and 1 × 24‐min applications provided the best balance between achieving significant whitening and minimizing hydrogen peroxide penetration into the pulp chamber, making them effective and safer alternatives for in‐office bleaching.Clinical Relevance: Shorter application times (2 × 8 min) or a single prolonged application (1 × 24 min) provide effective alternatives for achieving excellent whitening index results. These protocols reduce hydrogen peroxide penetration into the pulp chamber while also shortening the overall procedure time, enhancing both safety and efficiency.


  • Effect of light-activation systems associated with whitening pens in the bleaching efficacy and hydrogen peroxide permeability

    by Laryssa Mylenna Madruga Barbosa, Gabrielle Gomes Centenaro, Deisy Cristina Ferreira Cordeiro, Vinicius Borges Oliveira, Michael Willian Favoreto, Cesar Augusto Galvao Arrais, Alessandra Reis, Alessandro D. Loguercio


  • Effect of whitening pens on hydrogen peroxide permeability in the pulp chamber, color change and surface morphology

    by Laryssa Mylenna Madruga Barbosa, Gabrielle Gomes Centenaro, Deisy Cristina Ferreira Cordeiro, Maria Alice de Matos Rodrigues, Letícia Condolo, Michael Willian Favoreto, Alessandra Reis, Alessandro D. Loguercio


  • Effect of a brush tip on in-office bleaching gels in an attachable syringe: Hydrogen peroxide penetration, bleaching efficacy and amount of gel expended

    by Gabrielle Gomes Centenaro, Michael Willian Favoreto, Deisy Cristina Ferreira Cordeiro, Taynara de Souza Carneiro, Roberta Tarkany Basting, Alessandra Reis, Alessandro D. Loguercio