Dan Andrei
Research Subjects
Dan Andrei has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Anthony Licata
Licata Energy & Environmental Consultants, Inc. , Yonkers, NY 10701
2 shared publications - Dudley Benton
McHale and Associates , Knoxville, TN 37912
2 shared publications - Joe McHale
McHale and Associates , Knoxville, TN 37912
2 shared publications - Joseph M. Staller
Tennessee Tech University Department of Mechanical Engineering Cookeville, TN 38505
2 shared publications - Karsten Kopperstad
McHale and Associates , Knoxville, TN 37912
2 shared publications - Keith Kirkpatrick
McHale and Associates , Knoxville, TN 37912
2 shared publications
Latest Publications
- Open Access
- 1 January 2022
- Published by ASME International in ASME Open Journal of Engineering
- Vol. 1
A Real-Time Output–Loss Method for Monitoring Heat Rate for Coal-Fired Power Plants
This paper describes a real-time performance monitoring method based on PTC 4-2013 for determining instantaneous heat rates for coal-fired power plants. The calculation protocol uses a modified output–loss approach applied to a control volume that closely conforms to the boiler. The largest energy balance term is the heat transfer rate to the steam, which is known accurately in real-time when the plant employs properly calibrated instrumentation. The first-law energy balance also requires a balanced combustion equation which depends on coal composition, which is not known in real-time. A periodic or alert-driven calibration utilizes an ultimate analysis of a carefully collected coal sample and historic plant data obtained during the collection time of the coal sample. This is used to calculate correction factors for the coal mass flowrate, air preheater leakage, and CO2 and SO2 concentrations at the economizer exit derived from continuous emissions monitoring systems (CEMS) measurements performed at that location. The iterative calculations required to determine the coal composition in real-time are presented. The real-time performance algorithm exhibited significant sensitivity associated with measurements of the steam heat transfer rate, which was the dominant term in the overall boiler energy balance. Other input parameters generally yielded a much lower influence on calculated heat rate. It was concluded that for optimal accuracy of the output–loss method the steam and coal mass flowrates must be measured as accurately as possible.
- 1 January 2022
- Published by ASME International in ASME Open Journal of Engineering
- Vol. 1
Open AccessA Real-Time Output–Loss Method for Monitoring Heat Rate for Coal-Fired Power Plants
This paper describes a real-time performance monitoring method based on PTC 4-2013 for determining instantaneous heat rates for coal-fired power plants. The calculation protocol uses a modified output–loss approach applied to a control volume that closely conforms to the boiler. The largest energy balance term is the heat transfer rate to the steam, which is known accurately in real-time when the plant employs properly calibrated instrumentation. The first-law energy balance also requires a balanced combustion equation which depends on coal composition, which is not known in real-time. A periodic or alert-driven calibration utilizes an ultimate analysis of a carefully collected coal sample and historic plant data obtained during the collection time of the coal sample. This is used to calculate correction factors for the coal mass flowrate, air preheater leakage, and CO2 and SO2 concentrations at the economizer exit derived from continuous emissions monitoring systems (CEMS) measurements performed at that location. The iterative calculations required to determine the coal composition in real-time are presented. The real-time performance algorithm exhibited significant sensitivity associated with measurements of the steam heat transfer rate, which was the dominant term in the overall boiler energy balance. Other input parameters generally yielded a much lower influence on calculated heat rate. It was concluded that for optimal accuracy of the output–loss method the steam and coal mass flowrates must be measured as accurately as possible.
- Open Access
- 1 January 2022
- Published by ASME International in ASME Open Journal of Engineering
- Vol. 1
Exploring a Variant of PTC 4-2013 for Real-Time Performance Monitoring of Fossil Fuel Power Plants
This paper describes a real-time performance-monitoring method based on PTC 4-2013 that was developed for determining and reporting the annual heat rate for fossil fuel power plants. Unlike for the PTC 4 test, the coal composition is typically not known in real-time, so the procedure uses a modified output-loss approach applied to a control volume that closely conforms to the boiler. A calibration approach utilizes an ultimate analysis to describe the coal being burned during the calibration, while holding the plant load and other factors steady. This permits the calculation of correction factors used during real-time performance monitoring. Based on several assumptions that are justified within, a real-time estimate of coal composition is obtained. The losses are calculated in a similar manner to PTC 4-2013. However, the losses are expressed on a per-pound of as-fired coal basis, as opposed to a percentage of higher heating value of the coal, which is not known in real-time.
- 1 January 2022
- Published by ASME International in ASME Open Journal of Engineering
- Vol. 1
Open AccessExploring a Variant of PTC 4-2013 for Real-Time Performance Monitoring of Fossil Fuel Power Plants
This paper describes a real-time performance-monitoring method based on PTC 4-2013 that was developed for determining and reporting the annual heat rate for fossil fuel power plants. Unlike for the PTC 4 test, the coal composition is typically not known in real-time, so the procedure uses a modified output-loss approach applied to a control volume that closely conforms to the boiler. A calibration approach utilizes an ultimate analysis to describe the coal being burned during the calibration, while holding the plant load and other factors steady. This permits the calculation of correction factors used during real-time performance monitoring. Based on several assumptions that are justified within, a real-time estimate of coal composition is obtained. The losses are calculated in a similar manner to PTC 4-2013. However, the losses are expressed on a per-pound of as-fired coal basis, as opposed to a percentage of higher heating value of the coal, which is not known in real-time.