CDCătălin Dobrea

Cătălin Dobrea

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Cătălin Dobrea has a total of 6 co-authors. Here are the top co-authors by number of shared publications:

  • Claudiu-Ionel Nicola

    Research and Development Department, National Institute for Research, Development and Testing in Electrical Engineering—ICMET Craiova, 200746 Craiova, Romania

    1 shared publication
  • Cristian-Eugeniu Sălceanu

    Research and Development Department, National Institute for Research, Development and Testing in Electrical Engineering—ICMET Craiova, 200746 Craiova, Romania

    1 shared publication
  • Daniel Ocoleanu

    Research and Development Department, National Institute for Research, Development and Testing in Electrical Engineering—ICMET Craiova, 200746 Craiova, Romania

    1 shared publication
  • Daniela Iovan

    Research and Development Department, National Institute for Research, Development and Testing in Electrical Engineering—ICMET Craiova, 200746 Craiova, Romania

    1 shared publication
  • Marcel Nicola

    Research and Development Department, National Institute for Research, Development and Testing in Electrical Engineering—ICMET Craiova, 200746 Craiova, Romania

    1 shared publication
  • Sorin Enache

    Faculty of Electrical Engineering, University of Craiova, 200440 Craiova, Romania

    1 shared publication

Latest Publications

  • Open Access

    Experimental Study on the Behavior of Aluminum Fuse Element Inside 24 kV, 50 kA High-Voltage Fuses

    by Cristian-Eugeniu Sălceanu, Marcel Nicola, Claudiu-Ionel Nicola, Daniel Ocoleanu, Cătălin Dobrea, Daniela Iovan, Sorin Enache

    High-voltage fuses are found in most electrical installations, where they are used for overcurrent protection and are the pieces of equipment providing the highest degree of protection for the lowest initial cost. This article focuses on the behavior of high-voltage fuses containing a fuse element entirely made of aluminum. We made high-power linear electrical circuits for experiments on these fuses under the most severe operating conditions. The article presents the construction details of the fuse element and its features, as well as various arc extinguishing media. The heating behavior and time–current characteristics were studied in comparison with fuses made of copper. We obtained the maximum instantaneous value of the current reached during interruption for a 24 kV, 50 kA, 50 A fuse, as well as the value of the minimum breaking current.