Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Tayo Uthman Badrudeen has a total of 16 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Integrated standalone electric vehicle configurations with hybrid energy savings: Namibia intercity transportation case study

    by Chinedu T Obe, Tayo Badrudeen, Oliver O Apeh, Nnamdi Nwulu

    This paper presents a hybridized standalone electric vehicle (EV) design using hybrid energy storage system to solve the critical transportation issues in a grid-constrained environment, such as the city of Namibia. The suggested system integrates onboard regenerative braking and solar photovoltaic arrays of 3 kW (peak) to serve as the grid independent and obtain the substantial values of energy efficiency. This entails an innovative hybrid energy storage design, which combines both lithium-ion batteries and ultracapacitors banks where both the battery and the ultracapacitors can optimally store charge, with the battery to sustain the main power supply, and ultracapacitors to manages the peak loads on transient events such as acceleration and regenerative braking. The design uses automatic changeover system control in which it gives preference to the supply of solar and smooth integration of recovered kinetic energy in deceleration. Simulation findings indicate that the solar photovoltaic can supply about 25% of the daily energy demand, and the hybrid storage approach receives regenerative braking recovery rates of 20–25% in intercity cycles, which is far greater than the normal EV performance of 10–15%. The ultracapacitor subsystem can be charged 60–80% state-of-charge during an event of braking; this helps a great deal in relieving strain of battery by far over 2000 cycles. The comparative analysis indicates a high battery to wheel efficiency of 85% to 90%, low energy costs (0.19 NAD/km) than the traditional plug-in hybrid vehicles. Climate-adaptive building offers sustainable mobility with economic and energy benefits.

  • Open Access

    Optimization and cost evaluation of hybrid solar-wind-diesel-battery model for agri-food production in South Africa

    by Tayo Uthman Badrudeen, Nnamdi Nwulu, Benjamin O. Olorunfemi, Oluwadamilola Esan


  • Open Access

    Performance evaluation of STATCOM placement in real-world power system through DOA-NVSP algorithm for congestion management and stability improvement

    by Tayo Uthman Badrudeen, Funso K. Ariyo, Nnamdi Nwulu

    The study presents an assessment of STATCOM placement in 28-bus, 330kV Nigerian power network (NPN) using a DOA-NVSP approach. The NVSP was employed to define the security status and predict the suitable placement of the STATCOM. Thereafter, the DOA was employed to optimally site and size the STATCOM. However, the search agents of the DOA algorithm were restricted to select the best suitable placement from the NVSP suggested locations. The DOA produces two best search agents based on their fitness factor- Alpha and Beta. The results from these two were further evaluated for performance improvement in terms of the stability and congestion management. The response plot graph on voltage profile was achieved by determining the degree of deviation of each search agent to reference or ideal bus voltage. Thereafter, the nonlinear least square (NLS) was employed to fit and compare the ideal operating voltage from Alpha and Beta STACOM sizing corresponding voltages. The Levenberg–Marquardt (LM) and trust-region (TR) algorithm were considered for the training of the NLS. The results from the NLS analysis show 0.0266, 0.3171 and 0.0340 for SSE, R-square and Rmse, respectively, for LM algorithm and 0.0220, 0.3890 and 0.0309 for SSE, R-square and Rmse, respectively, for TR algorithm. Similarly, the decongestion of the transmission line after STATCOM placement at bus 16 was 11.3% and 9.3% for active and reactive power, respectively. The study concluded that the proposed model was able to improve the stability and congestion management of the NPN.


  • Open Access

    Control strategy for renewable energy driven self-excited induction generator

    by Tayo Uthman Badrudeen, Oluwafemi Omojola, Ayodeji Olalekan Salau, Sepiribo Lucky Braide, Joy Nnenna Eneh


  • Open Access

    Voltage stability improvement and power losses reduction through multiple grid contingency supports

    by Tayo Uthman Badrudeen, Funso K. Ariyo, Nnamdi Nwulu

    A stable power system is a desirable state for the optimal performance and delivery of electricity to the end-users. This study evaluates the effectiveness of grid contingency support devices in power system stability enhancement. The new voltage stability pointer (NVSP) was employed to optimally infer the flexible alternating current transmission systems devices through N − 1 contingency ranking. In this research, the static synchronous compensator (STATCOM) was considered as a grid support device. The effectiveness of this technique was validated in R2018a MATLAB with the IEEE 30-bus system using different combinable contingency cases to ascertain the critical lines and vulnerable buses to outages. Based on the results obtained through the NVSP, buses 30, 26, and 29 were cited as STATCOM candidate buses for overall optimal grid performance. The results obtained from the simulation revealed that the total real power loss was reduced by 90.21%. Similarly, the voltage magnitude of the buses was significantly improved to a minimum of 1.00 p.u. after placement of STATCOMs. Further investigation on single STATCOM placement in the IEEE 30-bus system revealed that the highest level of voltage improvement, minimum level of voltage deviation and maximum active power loss reduction was achieved when the STATCOM was placed at bus 30. The overall assessment of the proposed technique yielded better results compared with other methods on the same test system.


  • Open Access

    Neural Network Based Approach for Steady-State Stability Assessment of Power Systems

    by Tayo Uthman Badrudeen, Nnamdi I. Nwulu, Saheed Lekan Gbadamosi

    The quest for an intelligence compliance system to solve power stability problems in real-time with high predictive accuracy, and efficiency has led to the discovery of deep learning (DL) techniques. This paper investigates the potency of several artificial neural network (ANN) techniques in assessing the steady-state stability of a power system. The new voltage stability pointer (NVSP) was employed to parameterize and reduce the input data to the neural network algorithms to predict the proximity of power systems to voltage instability. In this study, we consider five neural network algorithms viz. feedforward neural network (FFNN), cascade-forward neural network (CFNN), layer recurrent neural network (LRNN), linear layer neural network (LLNN), and Elman neural network (ENN). The evaluation is based on the predictability and accuracy of these techniques for dynamic stability in power systems. The neural network algorithms were trained to mimic the NVSP dataset using a Levenberg-Marquardt (LM) model. Similarly, the performance analyses of the neural network techniques were deduced from the regression learner algorithm (RLA) using a root-mean-squared error (rmse) and response plot graph. The effectiveness of these NN algorithms was demonstrated on the IEEE 30-bus system and the Nigerian power system. The simulation results show that the FFNN and the CFNN possess a relatively better performance in terms of accuracy and efficiency for the considered power networks.


  • Open Access

    Analysis of a new voltage stability pointer for line contingency ranking in a power network

    by Tayo Uthman Badrudeen, Funso Kehinde Ariyo, Ayodeji Olalekan Salau, Sepiribo Lucky Braide

    Improper management of reactive power in a power network could lead to voltage instability. This paper presents a well-detailed study on voltage instability due to violation of power equilibrium in a power network and introduces a new voltage stability pointer (NVSP). The proposed NVSP is developed from a reduced 2-bus interconnected network to predict the sensistivity of voltage stability to reactive power variation. The simulation results from MATLAB were evaluated on IEEE 14-bus test system. The contingency ranking was achieved by varying the reactive power on the load buses to its maximum loading limit. The maximum reactive power point was taken at each load bus and the critical lines were ranked according to their vulnerability to voltage collapse. The results were compared with other notable voltage stability indices. The results prove that the NVSP is an essential tool in predicting voltage collapse.


  • Open Access

    A Novel Classification of the 330 kV Nigerian Power Network Using a New Voltage Stability Pointer

    by Tayo Uthman Badrudeen, Funso Kehinde Ariyo, Saheed Lekan Gbadamosi, Nnamdi I. Nwulu

    The incessant power outages that characterize the Nigerian power network (NGP), as in all developing countries, are not limited to the shortage of fuel for power generation. However, differential power shortages between the generated power and the load demand are alarming. In this study, we propose a new voltage stability pointer (NVSP) based on a reduced one-line power network to act as a classifier. The NVSP was trained with a support vector machine (SVM) using a medium Gaussian kernel classification toolbox (mGkCT) in the MATLAB environment. This classification is based on the power network susceptibility to voltage instability. NGP 28-bus 330 kV data were extracted and modeled in the MATLAB environment and tested with the NVSP-mGkCT classifier. The NVSP-mGkCT was able to classify the lines viz. stable and unstable lines for the base and contingency cases. Similarly, the linear load dynamics and non-linear load dynamics were evaluated on the basis of critical buses using the NVSP. The aim of this work was to help the Transmission Company of Nigeria (TCN) and the National Control Centre (NCC) to be pre-emptive with respect to possible voltage collapse due to voltage instability. The simulation results show that NVSP was able to flag vulnerable lines in the NGP.