Peng Du
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Peng Du has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Aobo Wang
Department of Orthopedics, Beijing Chaoyang Hospital, Capital Medical University, Beijing, China
6 shared publications - Lei Zang
Beijing Chao-Yang Hospital, Beijing, China
6 shared publications - Ning Fan
Department of Orthopedics, Beijing Chaoyang Hospital, Capital Medical University, Beijing, China
6 shared publications - Shuo Yuan
Department of Orthopedics, Beijing Chaoyang Hospital, Capital Medical University, Beijing, China
6 shared publications - Tianyi Wang
Department of Orthopedics, Beijing Chaoyang Hospital, Capital Medical University, Beijing, China
6 shared publications - Ruiyuan Chen
Department of Orthopedics Beijing Chao‐Yang Hospital, Capital Medical University Beijing China
5 shared publications
Latest Publications
- Open Access
- 10 July 2026
- Published by JMIR Publications Inc. in Journal of Medical Internet Research
- Vol. 28, e87816
Performance of DeepSeek-R1 and ChatGPT-5 in the Generation of North American Spine Society Clinical Guidelines for Adult Vertebral Compression Fractures: Comparative Study
Background: Vertebral compression fractures (VCFs) impose a substantial clinical and health care burden, and their management relies on timely access to evidence-based guidelines. Large language models (LLMs) may help clinicians rapidly obtain guideline-related information, but their performance on VCF guidelines remains unclear. Objective: This study aimed to evaluate the performance of LLMs, including DeepSeek-R1 and ChatGPT-5, in generating responses consistent with VCF clinical guidelines. Methods: Using the 2024 North American Spine Society VCF clinical guidelines as the reference standard, 34 open-ended and 87 closed-ended questions were submitted to DeepSeek-R1 and ChatGPT-5. Four senior spine surgeons independently rated responses to both closed-ended and open-ended questions using a 5-point Likert scale for accuracy, consistency, self-awareness, and fabrication/falsification. For open-ended questions, comprehensiveness, clarity, and trust and confidence were additionally assessed. Subgroup analyses were performed by question type, recommendation grade, and VCF subtype, with direct comparisons between models. Results: A total of 726 responses were generated for 121 questions. For closed-ended questions, ChatGPT-5 and DeepSeek-R1 showed comparable performance in accuracy ( P =.11), self-awareness ( P =.10), and fabrication/falsification ( P =.10). DeepSeek-R1 demonstrated better consistency than ChatGPT-5 for both closed-ended and open-ended questions ( P <.001 and P =.001, respectively). For open-ended questions, the models differed significantly in comprehensiveness ( P =.03) and trust and confidence ( P =.02), but not in accuracy ( P =.42), self-awareness ( P =.22), fabrication/falsification ( P =.64), or clarity ( P =.48). Closed-ended questions generally outperformed open-ended questions. Responses to grade A-C recommendations outperformed grade I recommendations in accuracy, consistency, and fabrication/falsification (all P ≤.001) but scored lower in self-awareness ( P <.001). No significant differences were observed across VCF subtypes. Conclusions: Under a standardized clinician-oriented prompting condition, ChatGPT-5 and DeepSeek-R1 showed generally high but variable scores across evaluation dimensions, with important deficiencies remaining, particularly in interventional and surgical treatment recommendations and in questions linked to recommendation grade I. Because these findings were obtained in a controlled prompting setting, caution is warranted when extrapolating them to other query styles, clinical scenarios, or LLMs.
- 10 July 2026
- Published by JMIR Publications Inc. in Journal of Medical Internet Research
- Vol. 28, e87816
Open AccessPerformance of DeepSeek-R1 and ChatGPT-5 in the Generation of North American Spine Society Clinical Guidelines for Adult Vertebral Compression Fractures: Comparative Study
Background: Vertebral compression fractures (VCFs) impose a substantial clinical and health care burden, and their management relies on timely access to evidence-based guidelines. Large language models (LLMs) may help clinicians rapidly obtain guideline-related information, but their performance on VCF guidelines remains unclear. Objective: This study aimed to evaluate the performance of LLMs, including DeepSeek-R1 and ChatGPT-5, in generating responses consistent with VCF clinical guidelines. Methods: Using the 2024 North American Spine Society VCF clinical guidelines as the reference standard, 34 open-ended and 87 closed-ended questions were submitted to DeepSeek-R1 and ChatGPT-5. Four senior spine surgeons independently rated responses to both closed-ended and open-ended questions using a 5-point Likert scale for accuracy, consistency, self-awareness, and fabrication/falsification. For open-ended questions, comprehensiveness, clarity, and trust and confidence were additionally assessed. Subgroup analyses were performed by question type, recommendation grade, and VCF subtype, with direct comparisons between models. Results: A total of 726 responses were generated for 121 questions. For closed-ended questions, ChatGPT-5 and DeepSeek-R1 showed comparable performance in accuracy ( P =.11), self-awareness ( P =.10), and fabrication/falsification ( P =.10). DeepSeek-R1 demonstrated better consistency than ChatGPT-5 for both closed-ended and open-ended questions ( P <.001 and P =.001, respectively). For open-ended questions, the models differed significantly in comprehensiveness ( P =.03) and trust and confidence ( P =.02), but not in accuracy ( P =.42), self-awareness ( P =.22), fabrication/falsification ( P =.64), or clarity ( P =.48). Closed-ended questions generally outperformed open-ended questions. Responses to grade A-C recommendations outperformed grade I recommendations in accuracy, consistency, and fabrication/falsification (all P ≤.001) but scored lower in self-awareness ( P <.001). No significant differences were observed across VCF subtypes. Conclusions: Under a standardized clinician-oriented prompting condition, ChatGPT-5 and DeepSeek-R1 showed generally high but variable scores across evaluation dimensions, with important deficiencies remaining, particularly in interventional and surgical treatment recommendations and in questions linked to recommendation grade I. Because these findings were obtained in a controlled prompting setting, caution is warranted when extrapolating them to other query styles, clinical scenarios, or LLMs.
- Open Access
- 30 April 2026
- Published by The Korean Spinal Neurosurgery Society in Neurospine
- Vol. 23 (2) , 393-403
Deep Learning-Assisted Lumbar Degeneration Evaluation Using Plain Radiographs: Development and Validation of a Novel Dual-Mechanism Architecture
Objective: To develop and externally validate a dual-mechanism deep learning (DL) model that integrates vertebral segmentation and lesion detection for automated evaluation of lumbar degeneration and structured report generation on plain radiographs.Methods: In this retrospective study, 5,964 patients who underwent standing anteroposterior and lateral lumbar radiographs at a single institution and 600 patients from a public dataset (BUU-Spine) were included. Vertebral corners from T11–L5 (and S1 on lateral views) and 7 degenerative findings (scoliosis, straightened/preserved lordosis, spondylolisthesis, disc space narrowing, osteophytes, vertebral compression, and abdominal aortic calcification) were annotated by 3 spine surgeons. Two independently trained, parallel networks were developed, including a ResNet-based segmentation network and a YOLOv8-based detection network. A rule-based integration strategy reconciled both outputs and generated structured diagnostic reports. Segmentation accuracy, quantitative measurement agreement, diagnostic performance, and clinical acceptability of reports were evaluated.Results: Intra- and interobserver landmark distances within 3 mm reached 96% and >95%, respectively. On the internal test set, the percentage of correct keypoints within 3 mm was 95.7%–98.6%, with intraclass correlation coefficients of 0.84–0.89 and Pearson correlation coefficient (r) of 0.90–0.94 for key radiographic parameters. The segmentation- and detection-based models achieved precision of 92.2%–96.9% and 91.7%–95.5%, and recall of 91.6%–94.8% and 93.3%–95.2%, respectively. Under the dual-positive condition, the integrated model yielded the highest precision (93.8%–97.3%), whereas the any-positive condition achieved the highest recall (94.1%–97.6%). Of 596 automatically generated structured reports, 557 (93.4%) were deemed clinically acceptable.Conclusion: The proposed dual-mechanism DL framework enables accurate, multilesion assessment of lumbar degeneration and generation of clinically acceptable structured reports from plain radiographs, supporting workflow optimization in lumbar spine imaging.
- 30 April 2026
- Published by The Korean Spinal Neurosurgery Society in Neurospine
- Vol. 23 (2) , 393-403
Open AccessDeep Learning-Assisted Lumbar Degeneration Evaluation Using Plain Radiographs: Development and Validation of a Novel Dual-Mechanism Architecture
Objective: To develop and externally validate a dual-mechanism deep learning (DL) model that integrates vertebral segmentation and lesion detection for automated evaluation of lumbar degeneration and structured report generation on plain radiographs.Methods: In this retrospective study, 5,964 patients who underwent standing anteroposterior and lateral lumbar radiographs at a single institution and 600 patients from a public dataset (BUU-Spine) were included. Vertebral corners from T11–L5 (and S1 on lateral views) and 7 degenerative findings (scoliosis, straightened/preserved lordosis, spondylolisthesis, disc space narrowing, osteophytes, vertebral compression, and abdominal aortic calcification) were annotated by 3 spine surgeons. Two independently trained, parallel networks were developed, including a ResNet-based segmentation network and a YOLOv8-based detection network. A rule-based integration strategy reconciled both outputs and generated structured diagnostic reports. Segmentation accuracy, quantitative measurement agreement, diagnostic performance, and clinical acceptability of reports were evaluated.Results: Intra- and interobserver landmark distances within 3 mm reached 96% and >95%, respectively. On the internal test set, the percentage of correct keypoints within 3 mm was 95.7%–98.6%, with intraclass correlation coefficients of 0.84–0.89 and Pearson correlation coefficient (r) of 0.90–0.94 for key radiographic parameters. The segmentation- and detection-based models achieved precision of 92.2%–96.9% and 91.7%–95.5%, and recall of 91.6%–94.8% and 93.3%–95.2%, respectively. Under the dual-positive condition, the integrated model yielded the highest precision (93.8%–97.3%), whereas the any-positive condition achieved the highest recall (94.1%–97.6%). Of 596 automatically generated structured reports, 557 (93.4%) were deemed clinically acceptable.Conclusion: The proposed dual-mechanism DL framework enables accurate, multilesion assessment of lumbar degeneration and generation of clinically acceptable structured reports from plain radiographs, supporting workflow optimization in lumbar spine imaging.
- Open Access
- 24 November 2025
- Published by JMIR Publications Inc. in Journal of Medical Internet Research
- Vol. 27, e77155
Deep Learning–Assisted Automated Diagnosis of Osteoporosis Based on Computed Tomography Scans: Systematic Review and Meta-Analysis
Background: Osteoporosis is a prevalent skeletal disorder characterized by decreased bone mass and increased fracture risk; however, it frequently remains underdiagnosed due to limited health care resources and its asymptomatic progression. Deep learning (DL) provides a promising solution for automated screening using computed tomography (CT) scans, enabling earlier detection and improved management. Objective: This systematic review and meta-analysis aimed to investigate the diagnostic performance of DL models in diagnosing osteoporosis based on CT scans. Methods: This study was conducted under the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) guidelines using articles extracted from PubMed, Scopus, Web of Science (Core), and Embase (Ovid). Studies involving adult participants who underwent CT and in which DL was applied for osteoporosis diagnosis were included. The QUADAS-2 (Quality Assessment of Diagnostic Accuracy Studies-2) tool was used to estimate the risk of bias in each study. The confusion matrices from the included studies were extracted to summarize the diagnostic performance of DL models for osteoporosis. Within a bivariate random-effects framework, sensitivity and specificity were jointly synthesized to yield the summary estimates. Heterogeneity was quantified with Higgins I² statistics. Subgroup analyses were performed to explore potential sources of heterogeneity among the included studies. Results: This review included 24 studies, encompassing CT images from 29,808 participants. All studies used conventional CT scans and used DL-based architectures. Fifteen, 6, and 3 studies were assessed as having a low, uncertain, and high risk of bias, respectively. The meta-analysis included 20 studies. The pooled sensitivity and specificity were 0.88 (95% CI 0.85‐0.91; I 2 =83.69%) and 0.94 (95% CI 0.91‐0.96; I 2 =95.07%) for osteoporosis diagnosis; 0.81 (95% CI 0.76‐0.85; I 2 =82.38%) and 0.92 (95% CI 0.90‐0.94; I 2 =79.05%) for osteopenia identification; and 0.95 (95% CI 0.92‐0.97; I 2 =98.28%) and 0.93 (95% CI 0.91‐0.95; I 2 =94.93%) for normal case identification. The area under the curve of the DL models for identifying osteoporosis, osteopenia, and normal cases was 0.96 (95% CI 0.93‐0.97), 0.94 (95% CI 0.92‐0.96), and 0.98 (95% CI 0.96‐0.99), respectively. Subgroup analyses revealed that models based on DenseNet variants ( P <.01), multislice input ( P <.01), 3D architecture ( P <.01), and CT as the reference standard ( P <.01) demonstrated superior diagnostic performance. Conclusions: This study indicated that CT-based DL models achieve promising diagnostic performance for osteoporosis. However, substantial heterogeneity among the included studies, limited external validation, and incomplete end-to-end pipelines constrain the generalizability of the proposed models. Further research is warranted to support their clinical translation and standardized application.
- 24 November 2025
- Published by JMIR Publications Inc. in Journal of Medical Internet Research
- Vol. 27, e77155
Open AccessDeep Learning–Assisted Automated Diagnosis of Osteoporosis Based on Computed Tomography Scans: Systematic Review and Meta-Analysis
Background: Osteoporosis is a prevalent skeletal disorder characterized by decreased bone mass and increased fracture risk; however, it frequently remains underdiagnosed due to limited health care resources and its asymptomatic progression. Deep learning (DL) provides a promising solution for automated screening using computed tomography (CT) scans, enabling earlier detection and improved management. Objective: This systematic review and meta-analysis aimed to investigate the diagnostic performance of DL models in diagnosing osteoporosis based on CT scans. Methods: This study was conducted under the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) guidelines using articles extracted from PubMed, Scopus, Web of Science (Core), and Embase (Ovid). Studies involving adult participants who underwent CT and in which DL was applied for osteoporosis diagnosis were included. The QUADAS-2 (Quality Assessment of Diagnostic Accuracy Studies-2) tool was used to estimate the risk of bias in each study. The confusion matrices from the included studies were extracted to summarize the diagnostic performance of DL models for osteoporosis. Within a bivariate random-effects framework, sensitivity and specificity were jointly synthesized to yield the summary estimates. Heterogeneity was quantified with Higgins I² statistics. Subgroup analyses were performed to explore potential sources of heterogeneity among the included studies. Results: This review included 24 studies, encompassing CT images from 29,808 participants. All studies used conventional CT scans and used DL-based architectures. Fifteen, 6, and 3 studies were assessed as having a low, uncertain, and high risk of bias, respectively. The meta-analysis included 20 studies. The pooled sensitivity and specificity were 0.88 (95% CI 0.85‐0.91; I 2 =83.69%) and 0.94 (95% CI 0.91‐0.96; I 2 =95.07%) for osteoporosis diagnosis; 0.81 (95% CI 0.76‐0.85; I 2 =82.38%) and 0.92 (95% CI 0.90‐0.94; I 2 =79.05%) for osteopenia identification; and 0.95 (95% CI 0.92‐0.97; I 2 =98.28%) and 0.93 (95% CI 0.91‐0.95; I 2 =94.93%) for normal case identification. The area under the curve of the DL models for identifying osteoporosis, osteopenia, and normal cases was 0.96 (95% CI 0.93‐0.97), 0.94 (95% CI 0.92‐0.96), and 0.98 (95% CI 0.96‐0.99), respectively. Subgroup analyses revealed that models based on DenseNet variants ( P <.01), multislice input ( P <.01), 3D architecture ( P <.01), and CT as the reference standard ( P <.01) demonstrated superior diagnostic performance. Conclusions: This study indicated that CT-based DL models achieve promising diagnostic performance for osteoporosis. However, substantial heterogeneity among the included studies, limited external validation, and incomplete end-to-end pipelines constrain the generalizability of the proposed models. Further research is warranted to support their clinical translation and standardized application.
- Open Access
- 23 December 2024
- Published by JMIR Publications Inc. in Journal of Medical Internet Research
- Vol. 26 (1) , e54676
Machine Learning and Deep Learning for Diagnosis of Lumbar Spinal Stenosis: Systematic Review and Meta-Analysis
Background: Lumbar spinal stenosis (LSS) is a major cause of pain and disability in older individuals worldwide. Although increasing studies of traditional machine learning (TML) and deep learning (DL) were conducted in the field of diagnosing LSS and gained prominent results, the performance of these models has not been analyzed systematically. Objective: This systematic review and meta-analysis aimed to pool the results and evaluate the heterogeneity of the current studies in using TML or DL models to diagnose LSS, thereby providing more comprehensive information for further clinical application. Methods: This review was performed under the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) guidelines using articles extracted from PubMed, Embase databases, and Cochrane Library databases. Studies that evaluated DL or TML algorithms assessment value on diagnosing LSS were included, while those with duplicated or unavailable data were excluded. Quality Assessment of Diagnostic Accuracy Studies 2 was used to estimate the risk of bias in each study. The MIDAS module and the METAPROP module of Stata (StataCorp) were used for data synthesis and statistical analyses. Results: A total of 12 studies with 15,044 patients reported the assessment value of TML or DL models for diagnosing LSS. The risk of bias assessment yielded 4 studies with high risk of bias, 3 with unclear risk of bias, and 5 with completely low risk of bias. The pooled sensitivity and specificity were 0.84 (95% CI: 0.82-0.86; I2=99.06%) and 0.87 (95% CI 0.84-0.90; I2=98.7%), respectively. The diagnostic odds ratio was 36 (95% CI 26-49), the positive likelihood ratio (LR+) was 6.6 (95% CI 5.1-8.4), and the negative likelihood ratio (LR–) was 0.18 (95% CI 0.16-0.21). The summary receiver operating characteristic curves, the area under the curve of TML or DL models for diagnosing LSS of 0.92 (95% CI 0.89-0.94), indicating a high diagnostic value. Conclusions: This systematic review and meta-analysis emphasize that despite the generally satisfactory diagnostic performance of artificial intelligence systems in the experimental stage for the diagnosis of LSS, none of them is reliable and practical enough to apply in real clinical practice. Further efforts, including optimization of model balance, widely accepted objective reference standards, multimodal strategy, large dataset for training and testing, external validation, and sufficient and scientific report, should be made to bridge the distance between current TML or DL models and real-life clinical applications in future studies. Trial Registration: PROSPERO CRD42024566535; https://tinyurl.com/msx59x8k
- 23 December 2024
- Published by JMIR Publications Inc. in Journal of Medical Internet Research
- Vol. 26 (1) , e54676
Open AccessMachine Learning and Deep Learning for Diagnosis of Lumbar Spinal Stenosis: Systematic Review and Meta-Analysis
Background: Lumbar spinal stenosis (LSS) is a major cause of pain and disability in older individuals worldwide. Although increasing studies of traditional machine learning (TML) and deep learning (DL) were conducted in the field of diagnosing LSS and gained prominent results, the performance of these models has not been analyzed systematically. Objective: This systematic review and meta-analysis aimed to pool the results and evaluate the heterogeneity of the current studies in using TML or DL models to diagnose LSS, thereby providing more comprehensive information for further clinical application. Methods: This review was performed under the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) guidelines using articles extracted from PubMed, Embase databases, and Cochrane Library databases. Studies that evaluated DL or TML algorithms assessment value on diagnosing LSS were included, while those with duplicated or unavailable data were excluded. Quality Assessment of Diagnostic Accuracy Studies 2 was used to estimate the risk of bias in each study. The MIDAS module and the METAPROP module of Stata (StataCorp) were used for data synthesis and statistical analyses. Results: A total of 12 studies with 15,044 patients reported the assessment value of TML or DL models for diagnosing LSS. The risk of bias assessment yielded 4 studies with high risk of bias, 3 with unclear risk of bias, and 5 with completely low risk of bias. The pooled sensitivity and specificity were 0.84 (95% CI: 0.82-0.86; I2=99.06%) and 0.87 (95% CI 0.84-0.90; I2=98.7%), respectively. The diagnostic odds ratio was 36 (95% CI 26-49), the positive likelihood ratio (LR+) was 6.6 (95% CI 5.1-8.4), and the negative likelihood ratio (LR–) was 0.18 (95% CI 0.16-0.21). The summary receiver operating characteristic curves, the area under the curve of TML or DL models for diagnosing LSS of 0.92 (95% CI 0.89-0.94), indicating a high diagnostic value. Conclusions: This systematic review and meta-analysis emphasize that despite the generally satisfactory diagnostic performance of artificial intelligence systems in the experimental stage for the diagnosis of LSS, none of them is reliable and practical enough to apply in real clinical practice. Further efforts, including optimization of model balance, widely accepted objective reference standards, multimodal strategy, large dataset for training and testing, external validation, and sufficient and scientific report, should be made to bridge the distance between current TML or DL models and real-life clinical applications in future studies. Trial Registration: PROSPERO CRD42024566535; https://tinyurl.com/msx59x8k
- Open Access
- 18 November 2023
- Published by JMIR Publications Inc. in JMIR Preprints
Machine Learning and Deep Learning for Diagnosis of Lumbar Spinal Stenosis: Systematic Review and Meta-Analysis (Preprint)
BACKGROUND Lumbar spinal stenosis (LSS) is a major cause of pain and disability in older individuals worldwide. Although increasing studies of traditional machine learning (TML) and deep learning (DL) were conducted in the field of diagnosing LSS and gained prominent results, the performance of these models has not been analyzed systematically. OBJECTIVE This systematic review and meta-analysis aimed to pool the results and evaluate the heterogeneity of the current studies in using TML or DL models to diagnose LSS, thereby providing more comprehensive information for further clinical application. METHODS This review was performed under the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) guidelines using articles extracted from PubMed, Embase databases, and Cochrane Library databases. Studies that evaluated DL or TML algorithms assessment value on diagnosing LSS were included, while those with duplicated or unavailable data were excluded. Quality Assessment of Diagnostic Accuracy Studies 2 was used to estimate the risk of bias in each study. The MIDAS module and the METAPROP module of Stata (StataCorp) were used for data synthesis and statistical analyses. RESULTS A total of 12 studies with 15,044 patients reported the assessment value of TML or DL models for diagnosing LSS. The risk of bias assessment yielded 4 studies with high risk of bias, 3 with unclear risk of bias, and 5 with completely low risk of bias. The pooled sensitivity and specificity were 0.84 (95% CI: 0.82-0.86; I2=99.06%) and 0.87 (95% CI 0.84-0.90; I2=98.7%), respectively. The diagnostic odds ratio was 36 (95% CI 26-49), the positive likelihood ratio (LR+) was 6.6 (95% CI 5.1-8.4), and the negative likelihood ratio (LR–) was 0.18 (95% CI 0.16-0.21). The summary receiver operating characteristic curves, the area under the curve of TML or DL models for diagnosing LSS of 0.92 (95% CI 0.89-0.94), indicating a high diagnostic value. CONCLUSIONS This systematic review and meta-analysis emphasize that despite the generally satisfactory diagnostic performance of artificial intelligence systems in the experimental stage for the diagnosis of LSS, none of them is reliable and practical enough to apply in real clinical practice. Further efforts, including optimization of model balance, widely accepted objective reference standards, multimodal strategy, large dataset for training and testing, external validation, and sufficient and scientific report, should be made to bridge the distance between current TML or DL models and real-life clinical applications in future studies. CLINICALTRIAL PROSPERO CRD42024566535; https://tinyurl.com/msx59x8k
- 18 November 2023
- Published by JMIR Publications Inc. in JMIR Preprints
Open AccessMachine Learning and Deep Learning for Diagnosis of Lumbar Spinal Stenosis: Systematic Review and Meta-Analysis (Preprint)
BACKGROUND Lumbar spinal stenosis (LSS) is a major cause of pain and disability in older individuals worldwide. Although increasing studies of traditional machine learning (TML) and deep learning (DL) were conducted in the field of diagnosing LSS and gained prominent results, the performance of these models has not been analyzed systematically. OBJECTIVE This systematic review and meta-analysis aimed to pool the results and evaluate the heterogeneity of the current studies in using TML or DL models to diagnose LSS, thereby providing more comprehensive information for further clinical application. METHODS This review was performed under the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) guidelines using articles extracted from PubMed, Embase databases, and Cochrane Library databases. Studies that evaluated DL or TML algorithms assessment value on diagnosing LSS were included, while those with duplicated or unavailable data were excluded. Quality Assessment of Diagnostic Accuracy Studies 2 was used to estimate the risk of bias in each study. The MIDAS module and the METAPROP module of Stata (StataCorp) were used for data synthesis and statistical analyses. RESULTS A total of 12 studies with 15,044 patients reported the assessment value of TML or DL models for diagnosing LSS. The risk of bias assessment yielded 4 studies with high risk of bias, 3 with unclear risk of bias, and 5 with completely low risk of bias. The pooled sensitivity and specificity were 0.84 (95% CI: 0.82-0.86; I2=99.06%) and 0.87 (95% CI 0.84-0.90; I2=98.7%), respectively. The diagnostic odds ratio was 36 (95% CI 26-49), the positive likelihood ratio (LR+) was 6.6 (95% CI 5.1-8.4), and the negative likelihood ratio (LR–) was 0.18 (95% CI 0.16-0.21). The summary receiver operating characteristic curves, the area under the curve of TML or DL models for diagnosing LSS of 0.92 (95% CI 0.89-0.94), indicating a high diagnostic value. CONCLUSIONS This systematic review and meta-analysis emphasize that despite the generally satisfactory diagnostic performance of artificial intelligence systems in the experimental stage for the diagnosis of LSS, none of them is reliable and practical enough to apply in real clinical practice. Further efforts, including optimization of model balance, widely accepted objective reference standards, multimodal strategy, large dataset for training and testing, external validation, and sufficient and scientific report, should be made to bridge the distance between current TML or DL models and real-life clinical applications in future studies. CLINICALTRIAL PROSPERO CRD42024566535; https://tinyurl.com/msx59x8k
- Open Access
- 30 September 2022
- Published by The Korean Spinal Neurosurgery Society in Neurospine
- Vol. 19 (3) , 586-593
Posterior Apophyseal Ring Fracture in Adult Lumbar Disc Herniation: An 8-Year Experience in Minimally Invasive Surgical Management of 48 Cases
Objective: Posterior apophyseal ring fracture (PARF) is an uncommon disorder that is usually accompanied by lumbar disc herniation (LDH). The aim of this study to describe the 8-year experience of performing minimally invasive treatment of PARF, giving particular attention to surgical technique and clinical outcome.Methods: We reviewed 1,324 consecutive patients with LDH seen in our department between 2013 and 2020. Forty-eight patients (3.63%) were enrolled who were diagnosed with PARF associated with LDH and underwent transforminal endoscopic lumbar discectomy (TELD). Mean duration of the final postoperative follow-up was 5.1 years. The control group was comprised of 50 patients diagnosed with LDH without PARF at the same facility. Data on clinical outcomes were analyzed.Results: The mean operation time in the PARF group was 105.4 minutes, which was longer than the mean operation time of the control group (83.9 minutes) (p = 0.001). Surgical complications, including dural tears (6.3%) and surgical instrument rupture (4.2%) were more common in the PARF group (p = 0.025). However, there was no significant difference in the proportion of excellent and good results and recurrence rates between the LDH patients with and those without PARF, respectively.Conclusion: TELD is a safe and effective minimally invasive approach for the treatment of PARF. However, minimally invasive techniques may require longer operation time and steeper learning curve for inexperienced surgeons. The separation and removal of bone fragments, a key step in the procedure, requires patience and care to prevent rupture, residual surgical instruments, and leakage of cerebrospinal fluid.
- 30 September 2022
- Published by The Korean Spinal Neurosurgery Society in Neurospine
- Vol. 19 (3) , 586-593
Open AccessPosterior Apophyseal Ring Fracture in Adult Lumbar Disc Herniation: An 8-Year Experience in Minimally Invasive Surgical Management of 48 Cases
Objective: Posterior apophyseal ring fracture (PARF) is an uncommon disorder that is usually accompanied by lumbar disc herniation (LDH). The aim of this study to describe the 8-year experience of performing minimally invasive treatment of PARF, giving particular attention to surgical technique and clinical outcome.Methods: We reviewed 1,324 consecutive patients with LDH seen in our department between 2013 and 2020. Forty-eight patients (3.63%) were enrolled who were diagnosed with PARF associated with LDH and underwent transforminal endoscopic lumbar discectomy (TELD). Mean duration of the final postoperative follow-up was 5.1 years. The control group was comprised of 50 patients diagnosed with LDH without PARF at the same facility. Data on clinical outcomes were analyzed.Results: The mean operation time in the PARF group was 105.4 minutes, which was longer than the mean operation time of the control group (83.9 minutes) (p = 0.001). Surgical complications, including dural tears (6.3%) and surgical instrument rupture (4.2%) were more common in the PARF group (p = 0.025). However, there was no significant difference in the proportion of excellent and good results and recurrence rates between the LDH patients with and those without PARF, respectively.Conclusion: TELD is a safe and effective minimally invasive approach for the treatment of PARF. However, minimally invasive techniques may require longer operation time and steeper learning curve for inexperienced surgeons. The separation and removal of bone fragments, a key step in the procedure, requires patience and care to prevent rupture, residual surgical instruments, and leakage of cerebrospinal fluid.