Andrew Osborne
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Andrew Osborne has a total of 99 co-authors. Here are the top co-authors by number of shared publications:
- Curtis J. Donskey
Louis Stokes Cleveland VA Medical Center
5 shared publications Jennifer L. Cadnum
Research Service, Louis Stokes Cleveland VA Medical Center, Cleveland, OH, USA
4 shared publications- Samir Memic
VA Northeast Ohio Health Care: VA Northeast Ohio Healthcare System
3 shared publications Andrew Saleeb
2 shared publicationsJoseph Yacoub
2 shared publications- Maria M. Torres-Teran
Research Service, Louis Stokes Cleveland VA Medical Center, Cleveland, Ohio, USA
2 shared publications
Latest Publications
- 26 January 2026
- Published by Wolters Kluwer Health in Stroke
- Vol. 57 (8)
Guidelines in Action: Dual Antiplatelet Therapy for Nondisabling Stroke Within the 4.5-Hour Window
- 26 January 2026
- Published by Wolters Kluwer Health in Stroke
- Vol. 57 (8)
Guidelines in Action: Dual Antiplatelet Therapy for Nondisabling Stroke Within the 4.5-Hour Window
- Open Access
- 9 September 2024
- Published by Cambridge University Press (CUP) in Antimicrobial Stewardship & Healthcare Epidemiology
- Vol. 4 (1) , e123
A novel approach for safe and automated implementation of far ultraviolet-C light decontamination in clinical areas
A novel wall-mounted far ultraviolet-C (UV-C) light technology providing automated delivery of far UV-C only when people are not present reduced methicillin-resistant Staphylococcus aureus in a patient room and equipment room. The safety feature that discontinues far UV-C output when people are detected was effective in preventing far UV-C exposure.
- 9 September 2024
- Published by Cambridge University Press (CUP) in Antimicrobial Stewardship & Healthcare Epidemiology
- Vol. 4 (1) , e123
Open AccessA novel approach for safe and automated implementation of far ultraviolet-C light decontamination in clinical areas
A novel wall-mounted far ultraviolet-C (UV-C) light technology providing automated delivery of far UV-C only when people are not present reduced methicillin-resistant Staphylococcus aureus in a patient room and equipment room. The safety feature that discontinues far UV-C output when people are detected was effective in preventing far UV-C exposure.
- 4 September 2024
- Published by Cambridge University Press (CUP) in Infection Control & Hospital Epidemiology
- Vol. 45 (10) , 1250-1252
Evaluation of a wall-mounted far ultraviolet-C light device used for continuous air and surface decontamination in a dental office during routine patient care
A wall-mounted far ultraviolet-C light device used for continuous air and surface decontamination in a dental office reduced aerosolized bacteriophage MS2 and methicillin-resistant Staphylococcus aureus on steel disks by >3 log10 in 2 hours in unshaded areas in a procedure room. Far ultraviolet-C delivery was substantially reduced in shaded areas.
- 4 September 2024
- Published by Cambridge University Press (CUP) in Infection Control & Hospital Epidemiology
- Vol. 45 (10) , 1250-1252
Evaluation of a wall-mounted far ultraviolet-C light device used for continuous air and surface decontamination in a dental office during routine patient care
A wall-mounted far ultraviolet-C light device used for continuous air and surface decontamination in a dental office reduced aerosolized bacteriophage MS2 and methicillin-resistant Staphylococcus aureus on steel disks by >3 log10 in 2 hours in unshaded areas in a procedure room. Far ultraviolet-C delivery was substantially reduced in shaded areas.
- 22 April 2024
- Published by Elsevier
List of contributors
- 22 April 2024
- Published by Elsevier
- p. 349-352
Data management
- 2 August 2023
- Published by Cambridge University Press (CUP) in Infection Control & Hospital Epidemiology
- Vol. 45 (1) , 132-134
Efficacy of a far-ultraviolet-C light technology for continuous decontamination of air and surfaces
A wall-mounted, far-ultraviolet-C light technology reduced aerosolized bacteriophage MS2 by >3 log10 plaque-forming units within 30 minutes. Vegetative bacterial pathogens on steel disk carriers in the center of the room were reduced by >3 log10 after 45 minutes of exposure, but Candida auris and Clostridioides difficile spores were not.
- 2 August 2023
- Published by Cambridge University Press (CUP) in Infection Control & Hospital Epidemiology
- Vol. 45 (1) , 132-134
Efficacy of a far-ultraviolet-C light technology for continuous decontamination of air and surfaces
A wall-mounted, far-ultraviolet-C light technology reduced aerosolized bacteriophage MS2 by >3 log10 plaque-forming units within 30 minutes. Vegetative bacterial pathogens on steel disk carriers in the center of the room were reduced by >3 log10 after 45 minutes of exposure, but Candida auris and Clostridioides difficile spores were not.
- Open Access
- 1 June 2023
- Published by Cambridge University Press (CUP) in Antimicrobial Stewardship & Healthcare Epidemiology
- Vol. 3 (S2) , s65
Decontamination of bedding reduces the risk for contamination of personnel changing bedding: A simulation study
Background: The recent worldwide outbreak of Mpox virus infections has raised concern about the potential for nosocomial acquisition during handling of contaminated bedding or clothing. We conducted simulations to test the hypothesis that decontamination of bedding prior to handling could reduce the risk for contamination of personnel. Methods: We conducted a crossover trial to test the effectiveness of spraying contaminated bedding with a hydrogen peroxide disinfectant in reducing contamination of personnel during handling of the contaminated bedding. Bedding was contaminated on top and bottom surfaces with aerosolized bacteriophage MS2. Personnel (N = 10) wearing a cover gown and gloves removed the bedding from a patient bed and placed it into a hamper both with and without prior hydrogen peroxide spray decontamination. After handling the bedding, samples were collected to assess viral contamination of gloves, cover gown, neck or chest, and hands or wrists. Results: Contamination of the gloves and cover gown of personnel occurred frequently during handling of bedding and 20% of participants had contamination of their hands or wrists and neck after the simulation (Fig.). Decontamination of the bedding reduced contamination of the gloves and eliminated contamination of the cover gown, hands or wrists, or neck. Conclusion: Decontamination of bedding prior to handling could be an effective strategy to reduce the risk for nosocomial acquisition of Mpox by healthcare personnel. Disclosures: None
- 1 June 2023
- Published by Cambridge University Press (CUP) in Antimicrobial Stewardship & Healthcare Epidemiology
- Vol. 3 (S2) , s65
Open AccessDecontamination of bedding reduces the risk for contamination of personnel changing bedding: A simulation study
Background: The recent worldwide outbreak of Mpox virus infections has raised concern about the potential for nosocomial acquisition during handling of contaminated bedding or clothing. We conducted simulations to test the hypothesis that decontamination of bedding prior to handling could reduce the risk for contamination of personnel. Methods: We conducted a crossover trial to test the effectiveness of spraying contaminated bedding with a hydrogen peroxide disinfectant in reducing contamination of personnel during handling of the contaminated bedding. Bedding was contaminated on top and bottom surfaces with aerosolized bacteriophage MS2. Personnel (N = 10) wearing a cover gown and gloves removed the bedding from a patient bed and placed it into a hamper both with and without prior hydrogen peroxide spray decontamination. After handling the bedding, samples were collected to assess viral contamination of gloves, cover gown, neck or chest, and hands or wrists. Results: Contamination of the gloves and cover gown of personnel occurred frequently during handling of bedding and 20% of participants had contamination of their hands or wrists and neck after the simulation (Fig.). Decontamination of the bedding reduced contamination of the gloves and eliminated contamination of the cover gown, hands or wrists, or neck. Conclusion: Decontamination of bedding prior to handling could be an effective strategy to reduce the risk for nosocomial acquisition of Mpox by healthcare personnel. Disclosures: None
- 30 September 2022
- Published by Cambridge University Press (CUP) in Infection Control & Hospital Epidemiology
- Vol. 44 (8) , 1361-1364
Effectiveness of ultraviolet-C light treatment of shoes in reducing the transfer of pathogens into patient rooms by shoes of healthcare personnel
Contaminated shoes are a potential vector for dissemination of healthcare-associated pathogens. We demonstrated that healthcare personnel walking into patient rooms frequently transferred pathogens from their shoes to the floor. An 8-second treatment of shoes with a UV-C decontamination device significantly reduced the frequency of transfer of vegetative bacterial pathogens.
- 30 September 2022
- Published by Cambridge University Press (CUP) in Infection Control & Hospital Epidemiology
- Vol. 44 (8) , 1361-1364
Effectiveness of ultraviolet-C light treatment of shoes in reducing the transfer of pathogens into patient rooms by shoes of healthcare personnel
Contaminated shoes are a potential vector for dissemination of healthcare-associated pathogens. We demonstrated that healthcare personnel walking into patient rooms frequently transferred pathogens from their shoes to the floor. An 8-second treatment of shoes with a UV-C decontamination device significantly reduced the frequency of transfer of vegetative bacterial pathogens.