CVChristiaan G. A. Viviers

Christiaan G. A. Viviers

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Christiaan G. A. Viviers has a total of 40 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Out-of-Distribution Detection in Medical Imaging via Diffusion Trajectories

    by Lemar Abdi, Francisco Caetano, Amaan Valiuddin, Christiaan Viviers, Hamdi Joudeh, Fons van der Sommen


  • MedSymmFlow: Bridging Generative Modeling and Classification in Medical Imaging Through Symmetrical Flow Matching

    by Francisco Caetano, Lemar Abdi, Christiaan Viviers, Amaan Valiuddin, Fons van der Sommen


  • Open Access

    Out-of-Distribution Detection in Medical Imaging via Diffusion Trajectories

    by Lemar Abdi, Francisco Caetano, Amaan Valiuddin, Christiaan Viviers, Hamdi Joudeh, Fons van der Sommen

    In medical imaging, unsupervised out-of-distribution (OOD) detection offers an attractive approach for identifying pathological cases with extremely low incidence rates. In contrast to supervised methods, OOD-based approaches function without labels and are inherently robust to data imbalances. Current generative approaches often rely on likelihood estimation or reconstruction error, but these methods can be computationally expensive, unreliable, and require retraining if the inlier data changes. These limitations hinder their ability to distinguish nominal from anomalous inputs efficiently, consistently, and robustly. We propose a reconstruction-free OOD detection method that leverages the forward diffusion trajectories of a Stein score-based denoising diffusion model (SBDDM). By capturing trajectory curvature via the estimated Stein score, our approach enables accurate anomaly scoring with only five diffusion steps. A single SBDDM pre-trained on a large, semantically aligned medical dataset generalizes effectively across multiple Near-OOD and Far-OOD benchmarks, achieving state-of-the-art performance while drastically reducing computational cost during inference. Compared to existing methods, SBDDM achieves a relative improvement of up to 10.43% and 18.10% for Near-OOD and Far-OOD detection, making it a practical building block for real-time, reliable computer-aided diagnosis.

  • Open Access

    MedSymmFlow: Bridging Generative Modeling and Classification in Medical Imaging through Symmetrical Flow Matching

    by Francisco Caetano, Lemar Abdi, Christiaan Viviers, Amaan Valiuddin, Fons van der Sommen

    Reliable medical image classification requires accurate predictions and well-calibrated uncertainty estimates, especially in high-stakes clinical settings. This work presents MedSymmFlow, a generative-discriminative hybrid model built on Symmetrical Flow Matching, designed to unify classification, generation, and uncertainty quantification in medical imaging. MedSymmFlow leverages a latent-space formulation that scales to high-resolution inputs and introduces a semantic mask conditioning mechanism to enhance diagnostic relevance. Unlike standard discriminative models, it naturally estimates uncertainty through its generative sampling process. The model is evaluated on four MedMNIST datasets, covering a range of modalities and pathologies. The results show that MedSymmFlow matches or exceeds the performance of established baselines in classification accuracy and AUC, while also delivering reliable uncertainty estimates validated by performance improvements under selective prediction.

  • Can Your Generative Model Detect Out-of-Distribution Covariate Shift?

    by Christiaan Viviers, Amaan Valiuddin, Francisco Caetano, Lemar Abdi, Lena Filatova, Peter de With, Fons van der Sommen


  • Investigating and Improving Latent Density Segmentation Models for Aleatoric Uncertainty Quantification in Medical Imaging

    by M. M. Amaan Valiuddin, Christiaan G. A. Viviers, Ruud J. G. van Sloun, Peter H. N. de With, Fons van der Sommen

    Data uncertainties, such as sensor noise, occlusions or limitations in the acquisition method can introduce irreducible ambiguities in images, which result in varying, yet plausible, semantic hypotheses. In Machine Learning, this ambiguity is commonly referred to as aleatoric uncertainty. In image segmentation, latent density models can be utilized to address this problem. The most popular approach is the Probabilistic U-Net (PU-Net), which uses latent Normal densities to optimize the conditional data log-likelihood Evidence Lower Bound. In this work, we demonstrate that the PU-Net latent space is severely sparse and heavily under-utilized. To address this, we introduce mutual information maximization and entropy-regularized Sinkhorn Divergence in the latent space to promote homogeneity across all latent dimensions, effectively improving gradient-descent updates and latent space informativeness. Our results show that by applying this on public datasets of various clinical segmentation problems, our proposed methodology receives up to 11% performance gains compared against preceding latent variable models for probabilistic segmentation on the Hungarian-Matched Intersection over Union. The results indicate that encouraging a homogeneous latent space significantly improves latent density modeling for medical image segmentation.


  • Open Access

    Improved Pancreatic Cancer Detection and Localization on CT Scans: A Computer-Aided Detection Model Utilizing Secondary Features

    by Mark Ramaekers, Christiaan G. A. Viviers, Terese A. E. Hellström, Lotte J. S. Ewals, Nick Tasios, Igor Jacobs, Joost Nederend, Fons van der Sommen, Misha D. P. Luyer

    The early detection of pancreatic ductal adenocarcinoma (PDAC) is essential for optimal treatment of pancreatic cancer patients. We propose a tumor detection framework to improve the detection of pancreatic head tumors on CT scans. In this retrospective research study, CT images of 99 patients with pancreatic head cancer and 98 control cases from the Catharina Hospital Eindhoven were collected. A multi-stage 3D U-Net-based approach was used for PDAC detection including clinically significant secondary features such as pancreatic duct and common bile duct dilation. The developed algorithm was evaluated using a local test set comprising 59 CT scans. The model was externally validated in 28 pancreatic cancer cases of a publicly available medical decathlon dataset. The tumor detection framework achieved a sensitivity of 0.97 and a specificity of 1.00, with an area under the receiver operating curve (AUROC) of 0.99, in detecting pancreatic head cancer in the local test set. In the external test set, we obtained similar results, with a sensitivity of 1.00. The model provided the tumor location with acceptable accuracy obtaining a DICE Similarity Coefficient (DSC) of 0.37. This study shows that a tumor detection framework utilizing CT scans and secondary signs of pancreatic cancer can detect pancreatic tumors with high accuracy.


  • Advancing 6-DoF Instrument Pose Estimation in Variable X-Ray Imaging Geometries

    by Christiaan G. A. Viviers, Lena Filatova, Maurice Termeer, Peter H. N. de With, Fons van der Sommen

    Accurate 6-DoF pose estimation of surgical instruments during minimally invasive surgeries can substantially improve treatment strategies and eventual surgical outcome. Existing deep learning methods have achieved accurate results, but they require custom approaches for each object and laborious setup and training environments often stretching to extensive simulations, whilst lacking real-time computation. We propose a general-purpose approach of data acquisition for 6-DoF pose estimation tasks in X-ray systems, a novel and general purpose YOLOv5-6D pose architecture for accurate and fast object pose estimation and a complete method for surgical screw pose estimation under acquisition geometry consideration from a monocular cone-beam X-ray image. The proposed YOLOv5-6D pose model achieves competitive results on public benchmarks whilst being considerably faster at 42 FPS on GPU. In addition, the method generalizes across varying X-ray acquisition geometry and semantic image complexity to enable accurate pose estimation over different domains. Finally, the proposed approach is tested for bone-screw pose estimation for computer-aided guidance during spine surgeries. The model achieves a 92.41% by the 0.1∙ d ADD-S metric, demonstrating a promising approach for enhancing surgical precision and patient outcomes. The code for YOLOv5-6D is publicly available at https://github.com/cviviers/YOLOv5-6D-Pose.


  • Advancing Abdominal Organ and PDAC Segmentation Accuracy with Task-Specific Interactive Models

    by Sanne E. Okel, Christiaan G. A. Viviers, Mark Ramaekers, Terese A. E. Hellström, Nick Tasios, Dimitrios Mavroeidis, Jon Pluyter, Igor Jacobs, Misha Luyer, Peter H. N. de With, et al.

  • Open Access

    Computer-Aided Detection for Pancreatic Cancer Diagnosis: Radiological Challenges and Future Directions

    by Mark Ramaekers, Christiaan G. A. Viviers, Boris V. Janssen, Terese A. E. Hellström, Lotte Ewals, Kasper van der Wulp, Joost Nederend, Igor Jacobs, Jon R. Pluyter, Dimitrios Mavroeidis, et al.

    Radiological imaging plays a crucial role in the detection and treatment of pancreatic ductal adenocarcinoma (PDAC). However, there are several challenges associated with the use of these techniques in daily clinical practice. Determination of the presence or absence of cancer using radiological imaging is difficult and requires specific expertise, especially after neoadjuvant therapy. Early detection and characterization of tumors would potentially increase the number of patients who are eligible for curative treatment. Over the last decades, artificial intelligence (AI)-based computer-aided detection (CAD) has rapidly evolved as a means for improving the radiological detection of cancer and the assessment of the extent of disease. Although the results of AI applications seem promising, widespread adoption in clinical practice has not taken place. This narrative review provides an overview of current radiological CAD systems in pancreatic cancer, highlights challenges that are pertinent to clinical practice, and discusses potential solutions for these challenges.