Jan Boriesosdick
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Jan Boriesosdick has a total of 45 co-authors. Here are the top co-authors by number of shared publications:
- Jan Borggrefe
Ruhr University Bochum, Germany
9 shared publications - Arwed Elias Michael
Department of Radiology, Neuroradiology and Nuclear Medicine, Johannes Wesling University Hospital, Ruhr University Bochum, 44801 Bochum, Germany
8 shared publications - Jan Robert Kroeger
Department of Radiology, Neuroradiology and Nuclear Medicine, Johannes Wesling University Hospital, Ruhr University Bochum, 44801 Bochum, Germany
8 shared publications - Julius Henning Niehoff
Department of Radiology, Neuroradiology and Nuclear Medicine, Johannes Wesling University Hospital, Ruhr University Bochum, 44801 Bochum, Germany
8 shared publications - Matthias Michael Woeltjen
Department of Radiology, Neuroradiology and Nuclear Medicine, Johannes Wesling University Hospital, Ruhr University Bochum, 44801 Bochum, Germany
7 shared publications - Denise Schoenbeck
Department of Radiology, Neuroradiology and Nuclear Medicine, Johannes Wesling University Hospital, Ruhr University Bochum, 44801 Bochum, Germany
5 shared publications
Latest Publications
- Open Access
- 2 June 2025
- Published by MDPI AG in Diagnostics
- Vol. 15 (11) , 1413
Real-Time MR-Guided Lumbosacral Periradicular Injection Therapy Using a 0.55 T MRI System: A Phantom Study
Objective: The purpose of this study was to evaluate the accuracy and feasibility of magnetic resonance (MR)-guided periradicular nerve root injection therapy (PRT) using a 0.55 T magnetic resonance imaging (MRI) system with fast dynamic imaging in a phantom. Methods: Five radiologists with varying levels of experience in PRT performed nine randomly assigned PRT procedures: three under MR guidance, three under CT guidance using a fully integrated laser navigation system, and three under conventional CT guidance, all on a specialized phantom of the lumbar spine. The PRTs were assessed by two experienced neuroradiologists with expertise in interventions, using a scale of 1–5, as follows: 5 = excellent to very good, 4 = good, 3 = satisfactory 2 = bad, 1 = very bad. The puncture time and total intervention time were noted. Results: All procedures were technically successful. The subjective evaluation of the PRTs showed similar results with a median of 5 for all three guidance systems. Additionally, there was no significant difference with respect to pure puncture time (the period after needle path determination) among all PRTs (Mean ± SD): MR-guided 178 ± 117 s, CT-guided with laser system 186 ± 73 s, and the conventional CT-guided 218 ± 91 s (p = 0.482). However, the total procedure time including planning images was significantly higher for MR-guided PRT (700 ± 182 s) compared to CT guidance with laser system (366 ± 85 s) and conventional CT guidance (358 ± 150 s; p = 0.012). Conclusions: Real-time MRI-guided lumbosacral periradicular injection therapy utilizing a 0.55 T MRI system is feasible with similar puncture times to CT guidance but consumes more intervention time due to the duration of planning sequences. Limitation: The study utilized a stationary phantom made of homogeneous material, which provides an incomplete representation of real tissue properties and motion complexity applied to human beings.
- 2 June 2025
- Published by MDPI AG in Diagnostics
- Vol. 15 (11) , 1413
Open AccessReal-Time MR-Guided Lumbosacral Periradicular Injection Therapy Using a 0.55 T MRI System: A Phantom Study
Objective: The purpose of this study was to evaluate the accuracy and feasibility of magnetic resonance (MR)-guided periradicular nerve root injection therapy (PRT) using a 0.55 T magnetic resonance imaging (MRI) system with fast dynamic imaging in a phantom. Methods: Five radiologists with varying levels of experience in PRT performed nine randomly assigned PRT procedures: three under MR guidance, three under CT guidance using a fully integrated laser navigation system, and three under conventional CT guidance, all on a specialized phantom of the lumbar spine. The PRTs were assessed by two experienced neuroradiologists with expertise in interventions, using a scale of 1–5, as follows: 5 = excellent to very good, 4 = good, 3 = satisfactory 2 = bad, 1 = very bad. The puncture time and total intervention time were noted. Results: All procedures were technically successful. The subjective evaluation of the PRTs showed similar results with a median of 5 for all three guidance systems. Additionally, there was no significant difference with respect to pure puncture time (the period after needle path determination) among all PRTs (Mean ± SD): MR-guided 178 ± 117 s, CT-guided with laser system 186 ± 73 s, and the conventional CT-guided 218 ± 91 s (p = 0.482). However, the total procedure time including planning images was significantly higher for MR-guided PRT (700 ± 182 s) compared to CT guidance with laser system (366 ± 85 s) and conventional CT guidance (358 ± 150 s; p = 0.012). Conclusions: Real-time MRI-guided lumbosacral periradicular injection therapy utilizing a 0.55 T MRI system is feasible with similar puncture times to CT guidance but consumes more intervention time due to the duration of planning sequences. Limitation: The study utilized a stationary phantom made of homogeneous material, which provides an incomplete representation of real tissue properties and motion complexity applied to human beings.
- 10 October 2023
- Published by Elsevier in Journal of Stroke and Cerebrovascular Diseases
- Vol. 32 (12) , 107421
Sarcopenia is a predictor of patient death in acute ischemic stroke
- 10 October 2023
- Published by Elsevier in Journal of Stroke and Cerebrovascular Diseases
- Vol. 32 (12) , 107421
Sarcopenia is a predictor of patient death in acute ischemic stroke
- 13 April 2023
- Published by Georg Thieme Verlag KG in RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
- Vol. 195 (S 01) , S75-S76
Low Dose Photon Counting CT zur Detektion von Nieren- und Harnleitersteinen: Eine Reduktion der Strahlendosis ist ohne wesentliche Beeinträchtigung der Bildqualität möglich
Zielsetzung Ein natives CT des Abdomens gilt als Methode der Wahl zum Nachweis einer Urolithiasis. Hierbei gilt es zu berücksichtigen, dass betroffene Patienten sehr jung sein können und häufig Rezidive auftreten. Ziel dieser Studie war es daher zu untersuchen, ob (a) eine Reduktion der Strahlendosis mit einem Photon Counting CT (PCCT, NAEOTOM Alpha, Siemens Healthineers) durch Verringern der Bildqualitäts-Stufe (BQ-Stufe) möglich ist und (b) ob hierdurch die Bildqualität und die diagnostische Aussagekraft beeinträchtigt wird. Material und Methoden Es wurden 98 PCCTs mit BQ-Stufe 70 (n=31), 60 (n=31) oder 50 (n=36) retrospektiv eingeschlossen. Die applizierte Strahlendosis (CTDI, DLP, SSDE und effektive Dosis) und die quantitative Bildqualität (SNR, Bildrauschen) wurden anhand verschiedener Parameter untersucht. Die subjektive Bildqualität, das Vorliegen einer Urolithiasis und die diagnostische Sicherheit wurden von drei Radiologen bewertet. Ergebnisse Das Verringern der BQ-Stufe führte zu einer deutlichen Reduktion der Strahlendosis; exemplarisch nahm das SSDE um 22,8% zwischen BQ70 (4,57±0,84 mGy) und BQ50 (3,53±0,70 mGy, p<0,001) ab. Gleichzeitig führte das Verringern der BQ-Stufe nur zu einer minimalen Verschlechterung der quantitativen Bildqualität; exemplarisch stieg das Bildrauschen im Muskel von 9,13±1,99 (BQ70) auf 9,91±1,77 (BQ50, p=0,248). Die Radiologen nahmen keine deutliche Verschlechterung der Bildqualität durch das Verringern der BQ-Stufe wahr. Die Detektionsraten von Nieren- und Harnleitersteinen unterschieden sich nicht wesentlich (91,3 – 100%) und auch die diagnostische Sicherheit wurde unabhängig von der BQ-Stufe als hoch eingestuft. Schlussfolgerungen Die Anpassung des PCCT Scanprotokolls durch Verringern der BQ-Stufe führt zu einer deutlichen Reduktion der Strahlendosis ohne wesentliche Beeinträchtigung der Bildqualität. Die Detektionsrate und die diagnostische Sicherheit werden durch die Verwendung eines Ultra Low Dose PCCT Scanprotokolls in dieser Studie nicht negativ beeinflusst. Article published online: 13 April 2023 © 2023. Thieme. All rights reserved. Georg Thieme Verlag Rüdigerstraße 14, 70469 Stuttgart, Germany
- 13 April 2023
- Published by Georg Thieme Verlag KG in RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
- Vol. 195 (S 01) , S75-S76
Low Dose Photon Counting CT zur Detektion von Nieren- und Harnleitersteinen: Eine Reduktion der Strahlendosis ist ohne wesentliche Beeinträchtigung der Bildqualität möglich
Zielsetzung Ein natives CT des Abdomens gilt als Methode der Wahl zum Nachweis einer Urolithiasis. Hierbei gilt es zu berücksichtigen, dass betroffene Patienten sehr jung sein können und häufig Rezidive auftreten. Ziel dieser Studie war es daher zu untersuchen, ob (a) eine Reduktion der Strahlendosis mit einem Photon Counting CT (PCCT, NAEOTOM Alpha, Siemens Healthineers) durch Verringern der Bildqualitäts-Stufe (BQ-Stufe) möglich ist und (b) ob hierdurch die Bildqualität und die diagnostische Aussagekraft beeinträchtigt wird. Material und Methoden Es wurden 98 PCCTs mit BQ-Stufe 70 (n=31), 60 (n=31) oder 50 (n=36) retrospektiv eingeschlossen. Die applizierte Strahlendosis (CTDI, DLP, SSDE und effektive Dosis) und die quantitative Bildqualität (SNR, Bildrauschen) wurden anhand verschiedener Parameter untersucht. Die subjektive Bildqualität, das Vorliegen einer Urolithiasis und die diagnostische Sicherheit wurden von drei Radiologen bewertet. Ergebnisse Das Verringern der BQ-Stufe führte zu einer deutlichen Reduktion der Strahlendosis; exemplarisch nahm das SSDE um 22,8% zwischen BQ70 (4,57±0,84 mGy) und BQ50 (3,53±0,70 mGy, p<0,001) ab. Gleichzeitig führte das Verringern der BQ-Stufe nur zu einer minimalen Verschlechterung der quantitativen Bildqualität; exemplarisch stieg das Bildrauschen im Muskel von 9,13±1,99 (BQ70) auf 9,91±1,77 (BQ50, p=0,248). Die Radiologen nahmen keine deutliche Verschlechterung der Bildqualität durch das Verringern der BQ-Stufe wahr. Die Detektionsraten von Nieren- und Harnleitersteinen unterschieden sich nicht wesentlich (91,3 – 100%) und auch die diagnostische Sicherheit wurde unabhängig von der BQ-Stufe als hoch eingestuft. Schlussfolgerungen Die Anpassung des PCCT Scanprotokolls durch Verringern der BQ-Stufe führt zu einer deutlichen Reduktion der Strahlendosis ohne wesentliche Beeinträchtigung der Bildqualität. Die Detektionsrate und die diagnostische Sicherheit werden durch die Verwendung eines Ultra Low Dose PCCT Scanprotokolls in dieser Studie nicht negativ beeinflusst. Article published online: 13 April 2023 © 2023. Thieme. All rights reserved. Georg Thieme Verlag Rüdigerstraße 14, 70469 Stuttgart, Germany
- Open Access
- 26 January 2023
- Published by MDPI AG in Diagnostics
- Vol. 13 (3) , 458
Clinical Low-Dose Photon-Counting CT for the Detection of Urolithiasis: Radiation Dose Reduction Is Possible without Compromising Image Quality
Background: This study evaluated the feasibility of reducing the radiation dose in abdominal imaging of urolithiasis with a clinical photon-counting CT (PCCT) by gradually lowering the image quality level (IQL) without compromising the image quality and diagnostic value. Methods: Ninety-eight PCCT examinations using either IQL70 (n = 31), IQL60 (n = 31) or IQL50 (n = 36) were retrospectively included. Parameters for the radiation dose and the quantitative image quality were analyzed. Qualitative image quality, presence of urolithiasis and diagnostic confidence were rated. Results: Lowering the IQL from 70 to 50 led to a significant decrease (22.8%) in the size-specific dose estimate (SSDE, IQL70 4.57 ± 0.84 mGy, IQL50 3.53 ± 0.70 mGy, p < 0.001). Simultaneously, lowering the IQL led to a minimal deterioration of the quantitative quality, e.g., image noise increased from 9.13 ± 1.99 (IQL70) to 9.91 ± 1.77 (IQL50, p = 0.248). Radiologists did not notice major changes in the image quality throughout the IQLs. Detection rates of urolithiasis (91.3–100%) did not differ markedly. Diagnostic confidence was high and not influenced by the IQL. Conclusions: Adjusting the PCCT scan protocol by lowering the IQL can significantly reduce the radiation dose without significant impairment of the image quality. The detection rate and diagnostic confidence are not impaired by using an ultra-low-dose PCCT scan protocol.
- 26 January 2023
- Published by MDPI AG in Diagnostics
- Vol. 13 (3) , 458
Open AccessClinical Low-Dose Photon-Counting CT for the Detection of Urolithiasis: Radiation Dose Reduction Is Possible without Compromising Image Quality
Background: This study evaluated the feasibility of reducing the radiation dose in abdominal imaging of urolithiasis with a clinical photon-counting CT (PCCT) by gradually lowering the image quality level (IQL) without compromising the image quality and diagnostic value. Methods: Ninety-eight PCCT examinations using either IQL70 (n = 31), IQL60 (n = 31) or IQL50 (n = 36) were retrospectively included. Parameters for the radiation dose and the quantitative image quality were analyzed. Qualitative image quality, presence of urolithiasis and diagnostic confidence were rated. Results: Lowering the IQL from 70 to 50 led to a significant decrease (22.8%) in the size-specific dose estimate (SSDE, IQL70 4.57 ± 0.84 mGy, IQL50 3.53 ± 0.70 mGy, p < 0.001). Simultaneously, lowering the IQL led to a minimal deterioration of the quantitative quality, e.g., image noise increased from 9.13 ± 1.99 (IQL70) to 9.91 ± 1.77 (IQL50, p = 0.248). Radiologists did not notice major changes in the image quality throughout the IQLs. Detection rates of urolithiasis (91.3–100%) did not differ markedly. Diagnostic confidence was high and not influenced by the IQL. Conclusions: Adjusting the PCCT scan protocol by lowering the IQL can significantly reduce the radiation dose without significant impairment of the image quality. The detection rate and diagnostic confidence are not impaired by using an ultra-low-dose PCCT scan protocol.
- 22 September 2022
- Published by SAGE Publications in Interventional Neuroradiology
- Vol. 30 (3) , 380-388
Mechanical thrombectomy using the Nimbus stent-retriever – initial experiences in a single-center observational study
Background: The Nimbus stent-retriever (NSR) was developed for mechanical thrombectomy of wall-adherent thrombi in cerebral arteries. It features a novel geometry with a proximal spiral section and a distal barrel section. The new device is designed to retrieve tough clots with a micro-clamping technique. In the first case series reporting on the NSR, we share our initial experience about the first 12 treated cases. Methods: In total, 12 patients (5 men, 7 women; mean age 78 years) with occlusion of the internal carotid artery or the middle cerebral artery (M1 or M2 segment) were treated with the NSR, 11 after unsuccessful recanalization attempts with conventional stent-retrievers or aspiration thrombectomy. Results: Retrieving maneuvers with the NSR recovered a thrombus in 7 patients (58%), of which 6 resulted in vessel recanalization mTICI ≥ 2b. Successful recanalization improved the mTICI score by a median of 3 points. In 5 of 7 cases, this required only one thrombectomy maneuver. In 5 cases, no improvement of recanalization could be achieved with the NSR (1–3 attempts). No NSR-related complications occurred in this case series. Conclusions: In our initial experience, the NSR appeared to be a safe and effective second-line stent-retriever after unsuccessful MT with conventional stent-retrievers or aspiration thrombectomy allowing for mTICI ≥ 2b rescue thrombectomy in ab 50% of cases. No NSR associated complications occurred in our case series.
- 22 September 2022
- Published by SAGE Publications in Interventional Neuroradiology
- Vol. 30 (3) , 380-388
Mechanical thrombectomy using the Nimbus stent-retriever – initial experiences in a single-center observational study
Background: The Nimbus stent-retriever (NSR) was developed for mechanical thrombectomy of wall-adherent thrombi in cerebral arteries. It features a novel geometry with a proximal spiral section and a distal barrel section. The new device is designed to retrieve tough clots with a micro-clamping technique. In the first case series reporting on the NSR, we share our initial experience about the first 12 treated cases. Methods: In total, 12 patients (5 men, 7 women; mean age 78 years) with occlusion of the internal carotid artery or the middle cerebral artery (M1 or M2 segment) were treated with the NSR, 11 after unsuccessful recanalization attempts with conventional stent-retrievers or aspiration thrombectomy. Results: Retrieving maneuvers with the NSR recovered a thrombus in 7 patients (58%), of which 6 resulted in vessel recanalization mTICI ≥ 2b. Successful recanalization improved the mTICI score by a median of 3 points. In 5 of 7 cases, this required only one thrombectomy maneuver. In 5 cases, no improvement of recanalization could be achieved with the NSR (1–3 attempts). No NSR-related complications occurred in this case series. Conclusions: In our initial experience, the NSR appeared to be a safe and effective second-line stent-retriever after unsuccessful MT with conventional stent-retrievers or aspiration thrombectomy allowing for mTICI ≥ 2b rescue thrombectomy in ab 50% of cases. No NSR associated complications occurred in our case series.
- Open Access
- 23 June 2022
- Published by MDPI AG in Tomography
- Vol. 8 (4) , 1666-1675
Clinical Low Dose Photon Counting CT for the Detection of Urolithiasis: Evaluation of Image Quality and Radiation Dose
The purpose of this study was the evaluation of image quality and radiation dose parameters of the novel photon counting CT (PCCT, Naeotom Alpha, Siemens Healthineers) using low-dose scan protocols for the detection of urolithiasis. Standard CT scans were used as a reference (S40, Somatom Sensation 40, Siemens Healthineers). Sixty-three patients, who underwent CT scans between August and December 2021, were retrospectively enrolled. Thirty-one patients were examined with the PCCT and 32 patients were examined with the S40. Radiation dose parameters, as well as quantitative and qualitative image parameters, were analyzed. The presence of urolithiasis, image quality, and diagnostic certainty were rated on a 5-point-scale by 3 blinded readers. Both patient groups (PCCT and S40) did not differ significantly in terms of body mass index. Radiation dose was significantly lower for examinations with the PCCT compared to the S40 (2.4 ± 1.0 mSv vs. 3.4 ± 1.0 mSv; p < 0.001). The SNR was significantly better on images acquired with the PCCT (13.3 ± 3.3 vs. 8.2 ± 1.9; p < 0.001). The image quality of the PCCT was rated significantly better (4.3 ± 0.7 vs. 2.8 ± 0.6; p < 0.001). The detection rate of kidney or ureter calculi was excellent with both CT scanners (PCCT 97.8% and S40 99%, p = 0.611). In high contrast imaging, such as the depiction of stones of the kidney and the ureter, PCCT allows a significant reduction of radiation dose, while maintaining excellent diagnostic confidence and image quality. Given this image quality with our current protocol, further adjustments towards ultra-low-dose CT scans appear feasible.
- 23 June 2022
- Published by MDPI AG in Tomography
- Vol. 8 (4) , 1666-1675
Open AccessClinical Low Dose Photon Counting CT for the Detection of Urolithiasis: Evaluation of Image Quality and Radiation Dose
The purpose of this study was the evaluation of image quality and radiation dose parameters of the novel photon counting CT (PCCT, Naeotom Alpha, Siemens Healthineers) using low-dose scan protocols for the detection of urolithiasis. Standard CT scans were used as a reference (S40, Somatom Sensation 40, Siemens Healthineers). Sixty-three patients, who underwent CT scans between August and December 2021, were retrospectively enrolled. Thirty-one patients were examined with the PCCT and 32 patients were examined with the S40. Radiation dose parameters, as well as quantitative and qualitative image parameters, were analyzed. The presence of urolithiasis, image quality, and diagnostic certainty were rated on a 5-point-scale by 3 blinded readers. Both patient groups (PCCT and S40) did not differ significantly in terms of body mass index. Radiation dose was significantly lower for examinations with the PCCT compared to the S40 (2.4 ± 1.0 mSv vs. 3.4 ± 1.0 mSv; p < 0.001). The SNR was significantly better on images acquired with the PCCT (13.3 ± 3.3 vs. 8.2 ± 1.9; p < 0.001). The image quality of the PCCT was rated significantly better (4.3 ± 0.7 vs. 2.8 ± 0.6; p < 0.001). The detection rate of kidney or ureter calculi was excellent with both CT scanners (PCCT 97.8% and S40 99%, p = 0.611). In high contrast imaging, such as the depiction of stones of the kidney and the ureter, PCCT allows a significant reduction of radiation dose, while maintaining excellent diagnostic confidence and image quality. Given this image quality with our current protocol, further adjustments towards ultra-low-dose CT scans appear feasible.
- Open Access
- 24 May 2022
- Published by MDPI AG in Diagnostics
- Vol. 12 (6) , 1306
Photon Counting CT Angiography of the Head and Neck: Image Quality Assessment of Polyenergetic and Virtual Monoenergetic Reconstructions
Background: The purpose of the present study was the evaluation of the image quality of polyenergetic and monoenergetic reconstructions (PERs and MERs) of CT angiographies (CTAs) of the head and neck acquired with the novel photon counting CT (PCCT) method in clinical routine. Methods: Thirty-seven patients were enrolled in this retrospective study. Quantitative image parameters of the extracranial, intracranial and cerebral arteries were evaluated for the PER and MER (40–120 keV). Additionally, two radiologists rated the perceived image quality. Results: The mean CTDIvol used in the PCCT was 8.31 ± 1.19 mGy. The highest signal within the vessels was detected in the 40 keV MER, whereas the lowest noise was detected in the 115 keV MER. The most favorable contrast-to-noise-ratio (CNR) and signal-to-noise-ratio (SNR) were detected in the PER and low keV MER. In the qualitative image analysis, the PER was superior to the MER in all rated criteria. For MER, 60–65 keV was rated as best image quality. Conclusion: Overall, PCCT offers excellent image quality for CTAs of the head and neck. At the current state, the PER of the PCCT seems to be the most favorable reconstruction for diagnostic reporting.
- 24 May 2022
- Published by MDPI AG in Diagnostics
- Vol. 12 (6) , 1306
Open AccessPhoton Counting CT Angiography of the Head and Neck: Image Quality Assessment of Polyenergetic and Virtual Monoenergetic Reconstructions
Background: The purpose of the present study was the evaluation of the image quality of polyenergetic and monoenergetic reconstructions (PERs and MERs) of CT angiographies (CTAs) of the head and neck acquired with the novel photon counting CT (PCCT) method in clinical routine. Methods: Thirty-seven patients were enrolled in this retrospective study. Quantitative image parameters of the extracranial, intracranial and cerebral arteries were evaluated for the PER and MER (40–120 keV). Additionally, two radiologists rated the perceived image quality. Results: The mean CTDIvol used in the PCCT was 8.31 ± 1.19 mGy. The highest signal within the vessels was detected in the 40 keV MER, whereas the lowest noise was detected in the 115 keV MER. The most favorable contrast-to-noise-ratio (CNR) and signal-to-noise-ratio (SNR) were detected in the PER and low keV MER. In the qualitative image analysis, the PER was superior to the MER in all rated criteria. For MER, 60–65 keV was rated as best image quality. Conclusion: Overall, PCCT offers excellent image quality for CTAs of the head and neck. At the current state, the PER of the PCCT seems to be the most favorable reconstruction for diagnostic reporting.
- Open Access
- 21 January 2022
- Published by MDPI AG in Diagnostics
- Vol. 12 (2) , 265
Image-Quality Assessment of Polyenergetic and Virtual Monoenergetic Reconstructions of Unenhanced CT Scans of the Head: Initial Experiences with the First Photon-Counting CT Approved for Clinical Use
In 2021, the first clinical photon-counting CT (PCCT) was introduced. The purpose of this study is to evaluate the image quality of polyenergetic and virtual monoenergetic reconstructions in unenhanced PCCTs of the head. A total of 49 consecutive patients with unenhanced PCCTs of the head were retrospectively included. The signals ± standard deviations of the gray and white matter were measured at three different locations in axial slices, and a measure of the artifacts below the cranial calvaria and in the posterior fossa between the petrous bones was also obtained. The signal-to-noise ratios (SNRs) and contrast-to-noise ratios (CNRs) were calculated for all reconstructions. In terms of the SNRs and CNRs, the polyenergetic reconstruction is superior to all virtual monoenergetic reconstructions (p < 0.001). In the MERs, the highest SNR is found in the 70 keV MER, and the highest CNR is in the 65 keV MER. In terms of artifacts below the cranial calvaria and in the posterior fossa, certain MERs are superior to polyenergetic reconstruction (p < 0.001). The PCCT provided excellent image contrast and low-noise profiles for the differentiation of the grey and white matter. Only the artifacts below the calvarium and in the posterior fossa still underperform, which is attributable to the lack of an artifact reduction algorithm in image postprocessing. It is conceivable that the usual improvements in image postprocessing, especially with regard to glaring artifacts, will lead to further improvements in image quality.
- 21 January 2022
- Published by MDPI AG in Diagnostics
- Vol. 12 (2) , 265
Open AccessImage-Quality Assessment of Polyenergetic and Virtual Monoenergetic Reconstructions of Unenhanced CT Scans of the Head: Initial Experiences with the First Photon-Counting CT Approved for Clinical Use
In 2021, the first clinical photon-counting CT (PCCT) was introduced. The purpose of this study is to evaluate the image quality of polyenergetic and virtual monoenergetic reconstructions in unenhanced PCCTs of the head. A total of 49 consecutive patients with unenhanced PCCTs of the head were retrospectively included. The signals ± standard deviations of the gray and white matter were measured at three different locations in axial slices, and a measure of the artifacts below the cranial calvaria and in the posterior fossa between the petrous bones was also obtained. The signal-to-noise ratios (SNRs) and contrast-to-noise ratios (CNRs) were calculated for all reconstructions. In terms of the SNRs and CNRs, the polyenergetic reconstruction is superior to all virtual monoenergetic reconstructions (p < 0.001). In the MERs, the highest SNR is found in the 70 keV MER, and the highest CNR is in the 65 keV MER. In terms of artifacts below the cranial calvaria and in the posterior fossa, certain MERs are superior to polyenergetic reconstruction (p < 0.001). The PCCT provided excellent image contrast and low-noise profiles for the differentiation of the grey and white matter. Only the artifacts below the calvarium and in the posterior fossa still underperform, which is attributable to the lack of an artifact reduction algorithm in image postprocessing. It is conceivable that the usual improvements in image postprocessing, especially with regard to glaring artifacts, will lead to further improvements in image quality.