MCMoustafa Sahnoune Chaouche

Moustafa Sahnoune Chaouche

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Moustafa Sahnoune Chaouche has a total of 13 co-authors. Here are the top co-authors by number of shared publications:

  • Aymen Flah

    Applied Science Research Center, Applied Science Private University, Amman, Jordan

    1 shared publication
  • Faouzi Didi

    Department of Common Core in Technology, Laboratory of Physics of Experimental Techniques and Their Applications University Yahia Fares of Medea Medea Algeria

    1 shared publication
  • Faouzi Didi

    Department of Common Core in Technology, Laboratory of Physics of Experimental Techniques and Their Applications, University Yahia Fares of Medea, 26.000, Algeria

    1 shared publication
  • Hamza Houassine

    Laboratoire D'Ingenierie des Systèmes Electriques et Automatique (LISEA) University of Bouira Bouira Algeria

    1 shared publication
  • Hamza Houassine

    Université Akli Mohand Oulhadj, Bouira, Algerie

    1 shared publication
  • Mohamed K. Metwaly

    Department of Electrical Engineering, College of Engineering Taif University Taif Saudi Arabia

    1 shared publication

Latest Publications

  • Open Access

    An Indirect Measurement Approach of a Uniform Transformer Winding Inductances Using Frequency Response Analysis Data: An Analytical Approach

    by Moustafa Sahnoune Chaouche, Faouzi Didi, Aymen Flah, Hamza Houassine, Slim Ben Chaabane, Rachid Sahnoune Chaouche, Mohd Fairouz Mohd Yousof, Mohamed K. Metwaly, Sherif S. M. Ghoneim

    This article proposes an innovative analytical method that estimates winding inductances directly from measurable frequency response analysis (FRA) data. The method constructs a polynomial function based on the inverse‐square sum of short‐circuit natural frequencies and equivalent inductance, incorporating a coupling factor that captures the extent of mutual interaction between discs. Unlike earlier numerical and optimisation‐based methods that typically involve a large number of inductance parameters, the proposed approach yields a physically meaningful real positive solution for the coupling factor. The approach offers a practical analytical solution for indirectly measuring the self‐ and mutual inductances of uniform windings, involving the measurement of relevant winding parameters—such as equivalent inductance, short‐circuit natural frequencies and series and shunt capacitances—using frequency response impedance data. The method then estimates self‐ and mutual inductances for uniform windings by solving a generalised polynomial developed for an N ‐section model, enabling the derivation of all windings' inductances. Experimental validation on isolated transformer windings demonstrated strong agreement between measured and estimated FRA curves, with root mean square error (RMSE) values below . These results confirm that the method offers a practical, traceable and accurate measurement‐based solution for inductance estimation, with potential applications in transformer condition assessment and fault diagnosis.

  • Design and Simulation of Grid-Connected Photovoltaic System’s Performance Analysis with Optimal Control of Maximum Power Point Tracking Based on Artificial Intelligence

    by Faouzi Didi, Moustafa Sahnoune Chaouche

    The research presented in this paper is part of a more significant effort to improve the dynamic and static performance of power generation systems using solar panels under specific climatic conditions. The solar panel can produce the greatest power only at the specified voltage and electric current levels. Environmental variables, such as random atmospheric oscillations, have a significant effect on the performance of a solar system connected to the network. Irradiation and ambient temperature are the two inputs to a PV (photovoltaic) system. Because solar radiation varies in nature, the PV system efficiency is low. To improve the efficiency of a solar PV system, several maximum power point tracking (MPPT) approaches are used. The purpose of this paper is to improve the performance of DC/DC chopper controllers and PV inverters in the face of abrupt climate change. To that end, the primary goal of this paper is to compare the following maximum power point search (MPPT) algorithms: the incremental conductance (IC) algorithm, the fuzzy logic (FL) algorithm, VSI controller, and the particle swarm optimization (PSO) strategy. These algorithms were evaluated in terms of efficiency, stability, and speed. A 100 kW PV system is design using MATLAB software 2021a version.


  • A Robust Approach for Locating and Assessing Mechanical Faults in an Actual Transformer Winding Using the State Space of Its Lumped Equivalent Model

    by Rachid Sahnoune Chaouche, Hamza Houassine, Samir Moulahoum, Moustafa Sahnoune Chaouche, Samir Bensaid

    Transfer function and state-space model are two powerful complementary tools have been used to monitoring the physical system. These two ways can be very successful in giving a comprehensive analysis of electrical power transformer malfunctions. This paper proposes a novel robust approach nondestructive to diagnose short circuit (SC) faults by considering axial displacements (AD) in the transformer winding. Initially, elaboration a native autonomously tool to control the LCR meters through computing systems. This platform will control the impedance measurement by the instrument of the LCR meter through MATLAB software. Additionally, achieving estimation autonomously to all the parameters of the lumped equivalent model of the winding accurately using frequency response analysis signal morphology interpretation (FRASMI). On the other hand, obtaining a new representation of the state-space model of the lumped equivalent model of an isolated winding with SC fault between its turns to locate and assess its severity. Finally, the relationship between the model parameters and the resonance frequencies of the frequency response curve can provide an effective nondestructive diagnostic tool for all mechanical damages of winding (e.g., SC with AD) which have been implemented experimentally, in which a new physical index has been proposed making it possible to locate and assess the extent of these defects simultaneously.