Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Jingzhi Rao has a total of 8 co-authors. Here are the top co-authors by number of shared publications:

  • Cheng Ji

    School of Chemistry and Chemical Engineering, Huaiyin Normal University, No. 111 West Changjiang Road, Huaian 223300, China

    4 shared publications
  • Wei Sun

    College of Chemical Engineering, Beijing University of Chemical Technology, North Third Ring Road 15, Chaoyang District, Beijing 100029, China

    4 shared publications
  • Jingde Wang

    College of Chemical Engineering, Beijing University of Chemical Technology, North Third Ring Road 15, Chaoyang District, Beijing 100029, China

    3 shared publications
  • Fangyuan Ma

    College of Chemical Engineering, Beijing University of Chemical Technology, North Third Ring Road 15, Chaoyang District, Beijing 100029, China

    1 shared publication
  • Fangyuan Ma

    College of Chemical Engineering, Beijing University of Chemical Technology, Beijing 100029, China

    1 shared publication
  • Jiatao Wen

    College of Chemical Engineering, Beijing University of Chemical Technology, Beijing 100029, China

    1 shared publication

Latest Publications

  • Open Access

    Bridging the Gap in Chemical Process Monitoring: Beyond Algorithm-Centric Research Toward Industrial Deployment

    by Cheng Ji, Fangyuan Ma, Jingzhi Rao, Jingde Wang, Wei Sun

    Over the past few decades, industrial process monitoring has been greatly advanced by machine learning and data analytics, with sophisticated models continuing to be developed and validated on benchmark processes such as the Tennessee Eastman simulation process. Yet, these models face significant barriers in real-world industrial deployment, as their increasing complexity leads to poor generalization, limited transparency, and difficulty in simultaneously achieving fault detection and root cause diagnosis, creating a persistent academia–industry gap. To address this challenge, this review systematically synthesizes three core categories of data-driven process monitoring methods (statistical, probabilistic, and deep learning-based approaches), delves into cutting-edge techniques tailored to mitigate the aforementioned practical constraints, and conducts an in-depth analysis of current obstacles hindering industrial application. Our analysis identifies a predominant algorithm-centric bias in current research, marked by overreliance on simulated benchmarks, insufficient model interpretability, and a misalignment with industrial requirements for lightweight and operable solutions. By integrating theoretical progress with industrial priorities, this study offers a cohesive roadmap for future research, establishing a foundation for developing more efficient, reliable, and secure chemical processes that bring practical utility to both academic and industrial practice.


  • Open Access

    A Data-Driven Method with Fusing Mechanism Information for Li-Ion Battery State of Charge Estimation

    by Zhanghua Xiao, Jingzhi Rao, Cheng Ji, Fangyuan Ma, Jingde Wang, Wei Sun

    Lithium-ion batteries have been extensively utilized as a high-power, rechargeable, and dischargeable energy storage medium. Accurate estimation of the battery state of charge (SOC) in the battery management system (BMS) is imperative for ensuring the safe and stable operation of electric vehicles. This paper proposes an SOC estimation method based on the equivalent circuit model as well as the ampere-time integration method with a physical informed neural network. The network enhances the estimation of SOC by introducing two mechanistic information sources: the equivalent circuit model (ECM) and the ampere-time integration method (Ah-I method). These are utilized as a priori knowledge to constrain the estimation of SOC. Initially, the Rint model is selected as the physical analysis model of the lithium-ion battery, and subsequently, the Ah-I method is chosen as the auxiliary model for SOC output estimation. A deep learning network is then employed to establish the mapping between the battery input parameters and the SOC output. Finally, the SOC is estimated by fusing the physical model and the data-driven model. The results demonstrate the efficacy of the method in accurately estimating the state of charge of lithium batteries, with a root mean square error within 1%. The validity of the research methodology was further validated through comparison with other approaches.


  • Open Access

    A Deep Non-Stationary Feature Extraction and Feature Fusion Framework for Real Industrial Process Monitoring

    by Jingzhi Rao, Cheng Ji, Jingde Wang, Wei Sun

    With the increasing demands for process safety and manufacturing efficiency, process monitoring has garnered significant attention from both academia and industry over the past few decades. Process monitoring aims to detect deviations from normal operating conditions by analyzing data features extracted under predefined normal states. However, the inherent non-stationarity of real industrial processes can compromise the accurate definition of these normal conditions, thereby limiting the effectiveness of traditional multivariate statistical process monitoring (MSPM) methods. A common strategy to address non-stationarity is to employ projection matrices that transform non-stationary time series into stationary ones, upon which monitoring statistics are constructed. Nevertheless, this approach often overlooks the valuable information contained in the non-stationary subspace, leading to insufficient extraction of fault-relevant features. Fault signatures may manifest in both stationary and non-stationary components of the process data. To overcome these limitations, an integrated monitoring framework that combines Stationary Subspace Analysis (SSA), a Stacked Autoencoder (SAE), and Support Vector Data Description (SVDD) is proposed in this research. Specifically, SSA was first applied to decompose the process data into stationary and non-stationary subspaces. Monitoring statistics were then constructed directly in the stationary subspace, while reconstruction errors from the SAE were used to capture features in the non-stationary subspace. Finally, SVDD was used to fuse the dual-space statistical indicators, enabling comprehensive fault detection. The proposed method was validated by the Tennessee Eastman and real industrial processes. Comparative results demonstrate that it outperformed existing non-stationary monitoring techniques in terms of monitoring performance.


  • Open Access

    Nonstationary Process Monitoring Based on Alternating Conditional Expectation and Cointegration Analysis

    by Jingzhi Rao, Cheng Ji, Jiatao Wen, Jingde Wang, Wei Sun

    Traditional multivariate statistical methods, which are often used to monitor stationary processes, are not applicable to nonstationary processes. Cointegration analysis (CA) is considered an effective method to deal with nonstationary variables. If there is a cointegration relationship among the nonstationary series in the system, it indicates that a stable long-term dynamic equilibrium relationship exists among these variables. However, due to the complexity of modern industrial processes, there are nonlinear relations between variables, which are not considered by the traditional linear cointegration theory. Alternating conditional expectation (ACE) can perform nonlinear transformation on these variables to maximize the linear correlation of the transformed variables. It will be helpful to deal with the nonlinear relations by modeling with transformed variables. In this work, a new monitoring strategy based on ACE and CA is proposed. The data are first transformed by an ACE algorithm, CA is performed after that, and then monitoring statistics are calculated to determine whether the system is faulty. The strategy is applied to the monitoring of a simulation case and a catalytic reforming unit in a petrochemical company. The results show that the strategy can realize the monitoring of nonstationary process, with a higher fault detection rate and a lower false alarm rate compared with the monitoring strategy based on traditional cointegration theory.