Maxwell J. Unger
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Maxwell J. Unger has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Alison R. H. Narayan
Department of Chemistry, University of Michigan, Ann Arbor, Michigan 48109, USA
3 shared publications - Robert T. Kennedy
Department of Chemistry, University of Michigan, Ann Arbor, Michigan 48109, USA
3 shared publications - G. Thomas Knecht
Department of Chemistry, University of Michigan, Ann Arbor, Michigan 48109, USA
2 shared publications - Jeffrey D. Martell
University of Wisconsin–Madison
2 shared publications Mario A. Cribari
Department of Chemistry, University of Wisconsin─Madison, Madison, Wisconsin 53706, United States
2 shared publicationsAdriana Vargas Figueroa
Department of Chemistry
1 shared publication
Latest Publications
- Open Access
- 13 October 2026
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 151 (20) , 6036-6046
Machine vision-enabled OD 600 measurement and mass spectrometric determination of metabolites of microbial cell-containing microfluidic droplets in real-time
Machine vision camera method for label-free measurement of OD 600 of microbes growing in flowing nanoliter droplets at 10 samples per s is presented.
- 13 October 2026
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 151 (20) , 6036-6046
Open AccessMachine vision-enabled OD 600 measurement and mass spectrometric determination of metabolites of microbial cell-containing microfluidic droplets in real-time
Machine vision camera method for label-free measurement of OD 600 of microbes growing in flowing nanoliter droplets at 10 samples per s is presented.
- 26 June 2026
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 98 (27) , 20442-20452
High-Throughput Screening of Isomeric Reaction Products by Droplet Microfluidics Coupled to Cyclic Ion Mobility-Mass Spectrometry
Engineered biocatalysts enable highly selective chemical transformations with low environmental impact. Development of biocatalysts by directed evolution requires screening many enzyme variants for improved catalytic properties. The low throughput of commonly used label-free screening methods, e.g., liquid chromatography-mass spectrometry (LC-MS), becomes the rate-limiting step in biocatalyst development, limiting the coverage of protein sequence space explored. Direct MS methods have been applied to biocatalyst screening; however, these methods cannot be used to evaluate isomer selectivity. Ion mobility spectrometry is a separation technique readily combined with MS, facilitating isomer differentiation on the millisecond time scale. Here, we present a droplet microfluidic system coupled to cyclic ion mobility-mass spectrometry (cIM-MS) to enable the screening of isomeric products. The system was applied to the separation of biaryl benzofuran dimers formed by the fungal cytochrome P450 KtnC. The isomeric 5,7'-bibenzofuran and 7,7'-bibenzofuran products from KtnC variants were baseline-resolved within 32 ms by cIM. By infusing biocatalytic reaction mixtures as 5 nL droplets, an analysis throughput of 1.2 s/droplet was achieved using cIM-MS. Droplet cIM-MS was used to quantify standards in the reaction matrix with high agreement to actual concentrations of each isomer (i.e., R2 of 0.97 and 0.98 for total bibenzofuran content and fractional 5,7'-bibenzofuran content, respectively). For samples with enzymatically formed product isomers, droplet cIM-MS identified the same active variants and had comparable reproducibility (RSD of 10-15%) to analysis by LC-MS and produced this data 128 times faster. The method is expected to be suitable for improving the rate of biocatalyst development for isomer-selective reactions.
- 26 June 2026
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 98 (27) , 20442-20452
High-Throughput Screening of Isomeric Reaction Products by Droplet Microfluidics Coupled to Cyclic Ion Mobility-Mass Spectrometry
Engineered biocatalysts enable highly selective chemical transformations with low environmental impact. Development of biocatalysts by directed evolution requires screening many enzyme variants for improved catalytic properties. The low throughput of commonly used label-free screening methods, e.g., liquid chromatography-mass spectrometry (LC-MS), becomes the rate-limiting step in biocatalyst development, limiting the coverage of protein sequence space explored. Direct MS methods have been applied to biocatalyst screening; however, these methods cannot be used to evaluate isomer selectivity. Ion mobility spectrometry is a separation technique readily combined with MS, facilitating isomer differentiation on the millisecond time scale. Here, we present a droplet microfluidic system coupled to cyclic ion mobility-mass spectrometry (cIM-MS) to enable the screening of isomeric products. The system was applied to the separation of biaryl benzofuran dimers formed by the fungal cytochrome P450 KtnC. The isomeric 5,7'-bibenzofuran and 7,7'-bibenzofuran products from KtnC variants were baseline-resolved within 32 ms by cIM. By infusing biocatalytic reaction mixtures as 5 nL droplets, an analysis throughput of 1.2 s/droplet was achieved using cIM-MS. Droplet cIM-MS was used to quantify standards in the reaction matrix with high agreement to actual concentrations of each isomer (i.e., R2 of 0.97 and 0.98 for total bibenzofuran content and fractional 5,7'-bibenzofuran content, respectively). For samples with enzymatically formed product isomers, droplet cIM-MS identified the same active variants and had comparable reproducibility (RSD of 10-15%) to analysis by LC-MS and produced this data 128 times faster. The method is expected to be suitable for improving the rate of biocatalyst development for isomer-selective reactions.
- 27 November 2025
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 97 (48) , 26607-26615
Phenotyping and Selection of Cells Using Mass Spectrometry and a Microfluidic Droplet Printer
Biotechnology is increasingly relying on high-throughput experiments in which large populations of cells are phenotyped and selected based on performance, e.g., for producing a desired product. Droplet microfluidics enables high-throughput screening, and as such, it lends itself ideally to such experiments, but reliance on a fluorescent readout is limiting. Herein, we report a system integrating droplet electrospray ionization-mass spectrometry (ESI-MS) with a microfluidic voltage-mediated droplet printer to enable online analysis and capture of cell-containing aqueous droplets, ultimately offering the possibility for label-free phenotyping and selection of cells. Escherichia coli (E. coli) cell-containing droplets (20 nL) are split into two volume fractions within a microfluidic splitter chip. One fraction is analyzed using a sheath-flow ESI source with MS, while the sibling fraction is printed onto an agar plate using a custom-built voltage-mediated microfluidic printer. Printed droplets can grow into single microbial colonies that map back to their respective droplet ESI-MS signal with 94-99% accuracy and without carryover. Nearly synchronous and stable system operation is shown for infusion rates in the range of 0.4-1.2 droplets/s, while the achieved droplet spacing and printing precision can enable reliable single-colony retrieval for further analyses or gene sequencing. The system is also shown for phenotyping and selection of an E. coli variant engineered to produce l-lysine among control cells. The method enables screening cell colonies for chemical composition and collecting them for further processing with potential application in synthetic biology and enzyme engineering among others.
- 27 November 2025
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 97 (48) , 26607-26615
Phenotyping and Selection of Cells Using Mass Spectrometry and a Microfluidic Droplet Printer
Biotechnology is increasingly relying on high-throughput experiments in which large populations of cells are phenotyped and selected based on performance, e.g., for producing a desired product. Droplet microfluidics enables high-throughput screening, and as such, it lends itself ideally to such experiments, but reliance on a fluorescent readout is limiting. Herein, we report a system integrating droplet electrospray ionization-mass spectrometry (ESI-MS) with a microfluidic voltage-mediated droplet printer to enable online analysis and capture of cell-containing aqueous droplets, ultimately offering the possibility for label-free phenotyping and selection of cells. Escherichia coli (E. coli) cell-containing droplets (20 nL) are split into two volume fractions within a microfluidic splitter chip. One fraction is analyzed using a sheath-flow ESI source with MS, while the sibling fraction is printed onto an agar plate using a custom-built voltage-mediated microfluidic printer. Printed droplets can grow into single microbial colonies that map back to their respective droplet ESI-MS signal with 94-99% accuracy and without carryover. Nearly synchronous and stable system operation is shown for infusion rates in the range of 0.4-1.2 droplets/s, while the achieved droplet spacing and printing precision can enable reliable single-colony retrieval for further analyses or gene sequencing. The system is also shown for phenotyping and selection of an E. coli variant engineered to produce l-lysine among control cells. The method enables screening cell colonies for chemical composition and collecting them for further processing with potential application in synthetic biology and enzyme engineering among others.
- 5 December 2023
- Published by American Chemical Society (ACS) in Journal of the American Chemical Society
- Vol. 145 (50) , 27380-27389
Ultrahigh-Throughput Directed Evolution of Polymer-Degrading Enzymes Using Yeast Display
Enzymes that degrade synthetic polymers have attracted intense interest for eco-friendly plastic recycling. However, because enzymes did not evolve for the cleavage of abiotic polymers, directed evolution strategies are needed to enhance activity for plastic degradation. Previous directed evolution efforts relied on polymer degradation assays that were limited to screening ∼104 mutants. Here, we report a high-throughput yeast surface display platform to rapidly evaluate >107 enzyme mutants for increased activity in cleaving synthetic polymers. In this platform, individual yeast cells display distinct mutants, and enzyme activity is detected by a change in fluorescence upon the cleavage of a synthetic probe resembling a polymer of interest. Highly active mutants are isolated by fluorescence activated cell sorting and identified through DNA sequencing. To demonstrate this platform, we performed directed evolution of a polyethylene terephthalate (PET)-depolymerizing enzyme, leaf and branch compost cutinase (LCC). We identified activity-boosting mutations that substantially increased the kinetics of degradation of solid PET films. Biochemical assays and molecular dynamics (MD) simulations of the most active variants suggest that the H218Y mutation improves the binding of the enzyme to PET. Overall, this evolution platform increases the screening throughput of polymer-degrading enzymes by 3 orders of magnitude and identifies mutations that enhance kinetics for depolymerizing solid substrates.
- 5 December 2023
- Published by American Chemical Society (ACS) in Journal of the American Chemical Society
- Vol. 145 (50) , 27380-27389
Ultrahigh-Throughput Directed Evolution of Polymer-Degrading Enzymes Using Yeast Display
Enzymes that degrade synthetic polymers have attracted intense interest for eco-friendly plastic recycling. However, because enzymes did not evolve for the cleavage of abiotic polymers, directed evolution strategies are needed to enhance activity for plastic degradation. Previous directed evolution efforts relied on polymer degradation assays that were limited to screening ∼104 mutants. Here, we report a high-throughput yeast surface display platform to rapidly evaluate >107 enzyme mutants for increased activity in cleaving synthetic polymers. In this platform, individual yeast cells display distinct mutants, and enzyme activity is detected by a change in fluorescence upon the cleavage of a synthetic probe resembling a polymer of interest. Highly active mutants are isolated by fluorescence activated cell sorting and identified through DNA sequencing. To demonstrate this platform, we performed directed evolution of a polyethylene terephthalate (PET)-depolymerizing enzyme, leaf and branch compost cutinase (LCC). We identified activity-boosting mutations that substantially increased the kinetics of degradation of solid PET films. Biochemical assays and molecular dynamics (MD) simulations of the most active variants suggest that the H218Y mutation improves the binding of the enzyme to PET. Overall, this evolution platform increases the screening throughput of polymer-degrading enzymes by 3 orders of magnitude and identifies mutations that enhance kinetics for depolymerizing solid substrates.
- 26 September 2022
- Published by American Chemical Society (ACS) in ACS Catalysis
- Vol. 12 (19) , 12246-12252
A Horseradish Peroxidase–Mediator System for Benzylic C–H Activation
Enzyme-mediator systems generate radical intermediates that abstract hydrogen atoms under mild conditions. These systems have been employed extensively for alcohol oxidation, primarily in biomass degradation, but they are underexplored for direct activation of C(sp3)-H bonds in alkyl groups. Here, we combine horseradish peroxidase (HRP), H2O2, and redox mediator N-hydroxyphthalimide (NHPI) for C(sp3)-H functionalization of alkylbenzene-type substrates. The HRP-NHPI system is >10-fold more active than existing enzyme-mediator systems in converting alkylbenzenes to ketones and aldehydes under air, and it operates from 0-50 °C and in numerous aqueous-organic solvent mixtures. The benzylic substrate radical can be trapped through a reaction with NHPI, demonstrating the formation of benzylic products beyond ketones. Furthermore, we demonstrate a one-pot, two-step enzymatic cascade for converting alkylbenzenes to benzylic amines. Overall, the HRP-NHPI system enables the selective benzylic C-H functionalization of diverse substrates under mild conditions using a straightforward procedure.
- 26 September 2022
- Published by American Chemical Society (ACS) in ACS Catalysis
- Vol. 12 (19) , 12246-12252
A Horseradish Peroxidase–Mediator System for Benzylic C–H Activation
Enzyme-mediator systems generate radical intermediates that abstract hydrogen atoms under mild conditions. These systems have been employed extensively for alcohol oxidation, primarily in biomass degradation, but they are underexplored for direct activation of C(sp3)-H bonds in alkyl groups. Here, we combine horseradish peroxidase (HRP), H2O2, and redox mediator N-hydroxyphthalimide (NHPI) for C(sp3)-H functionalization of alkylbenzene-type substrates. The HRP-NHPI system is >10-fold more active than existing enzyme-mediator systems in converting alkylbenzenes to ketones and aldehydes under air, and it operates from 0-50 °C and in numerous aqueous-organic solvent mixtures. The benzylic substrate radical can be trapped through a reaction with NHPI, demonstrating the formation of benzylic products beyond ketones. Furthermore, we demonstrate a one-pot, two-step enzymatic cascade for converting alkylbenzenes to benzylic amines. Overall, the HRP-NHPI system enables the selective benzylic C-H functionalization of diverse substrates under mild conditions using a straightforward procedure.