Mohan Anitha Asha Rani
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Mohan Anitha Asha Rani has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
C. Nagamani
9 shared publicationsG. Saravana Ilango
8 shared publications- Anabalagan Karthikeyan
Department of Electrical and Electronics Engineering, National Institute of Technology Karnataka, Mangalore, Surathkal, India
4 shared publications - Chilakapati Nagamani
Department of Electrical and Electronics Engineering, National Institute of Technology, Tiruchirappalli, India
4 shared publications - Nibedita Ghosh
NIT Silchar
3 shared publications Pydi Bala Krishna
Department of Electrical Engineering National Institute of Technology Silchar Silchar Assam India
3 shared publications
Latest Publications
- 2 January 2026
- Published by Springer Nature
- p. 375-385
Voltage Sag Mitigation in a Utility Grid-Tied SPV Wind Hybrid Microgrid by STATCOM
- 2 January 2026
- Published by Springer Nature
- p. 375-385
Voltage Sag Mitigation in a Utility Grid-Tied SPV Wind Hybrid Microgrid by STATCOM
- 2 January 2026
- Published by Springer Nature
- p. 353-363
Power Controlling of a Grid-Tied Microgrid by STATCOM
- 2 January 2026
- Published by Springer Nature
- p. 353-363
Power Controlling of a Grid-Tied Microgrid by STATCOM
- Open Access
- 29 October 2025
- Published by Springer Nature in Research Square
A Robust Reference Current Generation Scheme for Enhanced Operation of PMSG under Unbalanced Grid Conditions
Grid-connected Permanent Magnet Synchronous Generators (PMSGs) exhibit significant sensitivity to unbalanced grid voltages, particularly during voltage sags, which introduce negative sequence components that lead to undesirable oscillations in grid currents, active/reactive power, and DC link voltage at twice the grid frequency. This study aims to enhance the dynamic performance of PMSGs under such adverse conditions by developing a novel reference current generation strategy that mitigates these fluctuations without relying on dual vector control. The approach estimates the stator flux angular frequency in the α–β frame using voltage and current signals, eliminating the need for a PLL or voltage differentiation. The Machine-Side Converter (MSC) manages active power, while the Grid-Side Converter (GSC) maintains constant DC link voltage and Unity Power Factor (UPF). Extensive simulations and real-time validation using OPAL-RT OP4510 demonstrate the scheme’s robustness. For instance, in Case I, oscillations in active power, reactive power, grid current, and DC voltage were reduced from 12.05%, 4.22%, 13.07%, and 0.422% to 0.497%, 1.73%, 7.37%, and 0.0152%, respectively. In Case IV with a severe phase-A fault, oscillations dropped from 86.56% to 12.32% in active power and from 87.23% to 32.23% in grid current. Across all test cases, total harmonic distortion in grid current was consistently brought below 5%, proving the method’s superiority over conventional techniques. Simulations conducted on a 2.5kW PMSG under various unbalanced grid voltage conditions using PSCAD/EMTDC confirm the suggested method's efficacy and its edge over current control techniques.
- 29 October 2025
- Published by Springer Nature in Research Square
Open AccessA Robust Reference Current Generation Scheme for Enhanced Operation of PMSG under Unbalanced Grid Conditions
Grid-connected Permanent Magnet Synchronous Generators (PMSGs) exhibit significant sensitivity to unbalanced grid voltages, particularly during voltage sags, which introduce negative sequence components that lead to undesirable oscillations in grid currents, active/reactive power, and DC link voltage at twice the grid frequency. This study aims to enhance the dynamic performance of PMSGs under such adverse conditions by developing a novel reference current generation strategy that mitigates these fluctuations without relying on dual vector control. The approach estimates the stator flux angular frequency in the α–β frame using voltage and current signals, eliminating the need for a PLL or voltage differentiation. The Machine-Side Converter (MSC) manages active power, while the Grid-Side Converter (GSC) maintains constant DC link voltage and Unity Power Factor (UPF). Extensive simulations and real-time validation using OPAL-RT OP4510 demonstrate the scheme’s robustness. For instance, in Case I, oscillations in active power, reactive power, grid current, and DC voltage were reduced from 12.05%, 4.22%, 13.07%, and 0.422% to 0.497%, 1.73%, 7.37%, and 0.0152%, respectively. In Case IV with a severe phase-A fault, oscillations dropped from 86.56% to 12.32% in active power and from 87.23% to 32.23% in grid current. Across all test cases, total harmonic distortion in grid current was consistently brought below 5%, proving the method’s superiority over conventional techniques. Simulations conducted on a 2.5kW PMSG under various unbalanced grid voltage conditions using PSCAD/EMTDC confirm the suggested method's efficacy and its edge over current control techniques.
- 1 September 2025
- Published by AIP Publishing in Journal of Renewable and Sustainable Energy
- Vol. 17 (5)
Enhanced power quality in HVDC system integrated offshore DFIG wind power plant under onshore grid voltage imbalances
Ensuring stable and efficient power transfer from an offshore doubly fed induction generator based wind power plant to the onshore grid through a high voltage direct current (HVDC) link presents a complex control challenge due to dynamic grid conditions, system nonlinearities, and the need for precise coordination between converter stations. The offshore converter of the test HVDC system employs a line-commutated converter for efficient bulk power delivery, while a voltage source converter (VSC) at the onshore terminal enables decoupled real and reactive power exchange. Perturbations in onshore grid voltage directly impact the receiving end VSC station, inducing fluctuations in its operating parameters and compromising overall system performance due to grid imperfections. Under imbalanced grid voltage conditions, the conventional vector control approach results in significant power oscillations and harmonic distortions. To address this challenge, this paper proposes a reinforced current control (RCC) strategy, which injects dynamically computed compensating currents into the VSC control loop, effectively suppressing double frequency oscillations and maintaining power quality. The proposed scheme enables independent regulation of real and reactive power, mitigating power oscillations and minimizing the grid current total harmonic distortion (THD) induced by onshore grid voltage deviations. The system's performance is validated through simulations in power systems computer aided design/electromagnetic transients, including direct current and hardware-in-the-loop testing on the OP4510 real-time digital simulator developed by optimal algorithm for real-time. The proposed RCC strategy effectively suppresses active power oscillations to below 5% and maintains grid current THD within 3.5%, even under onshore voltage imbalances. The proposed strategy enhances system stability, fault ride-through capability, and compliance with Institute of Electrical and Electronics Engineers (IEEE) grid interconnection standards.
- 1 September 2025
- Published by AIP Publishing in Journal of Renewable and Sustainable Energy
- Vol. 17 (5)
Enhanced power quality in HVDC system integrated offshore DFIG wind power plant under onshore grid voltage imbalances
Ensuring stable and efficient power transfer from an offshore doubly fed induction generator based wind power plant to the onshore grid through a high voltage direct current (HVDC) link presents a complex control challenge due to dynamic grid conditions, system nonlinearities, and the need for precise coordination between converter stations. The offshore converter of the test HVDC system employs a line-commutated converter for efficient bulk power delivery, while a voltage source converter (VSC) at the onshore terminal enables decoupled real and reactive power exchange. Perturbations in onshore grid voltage directly impact the receiving end VSC station, inducing fluctuations in its operating parameters and compromising overall system performance due to grid imperfections. Under imbalanced grid voltage conditions, the conventional vector control approach results in significant power oscillations and harmonic distortions. To address this challenge, this paper proposes a reinforced current control (RCC) strategy, which injects dynamically computed compensating currents into the VSC control loop, effectively suppressing double frequency oscillations and maintaining power quality. The proposed scheme enables independent regulation of real and reactive power, mitigating power oscillations and minimizing the grid current total harmonic distortion (THD) induced by onshore grid voltage deviations. The system's performance is validated through simulations in power systems computer aided design/electromagnetic transients, including direct current and hardware-in-the-loop testing on the OP4510 real-time digital simulator developed by optimal algorithm for real-time. The proposed RCC strategy effectively suppresses active power oscillations to below 5% and maintains grid current THD within 3.5%, even under onshore voltage imbalances. The proposed strategy enhances system stability, fault ride-through capability, and compliance with Institute of Electrical and Electronics Engineers (IEEE) grid interconnection standards.
- 4 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
A Novel Backup Protection to Realize Reliable Numerical Protection
This paper proposes a novel backup protection to realize reliable numerical protection using the current index and power factor quantities. These quantities, estimated by the synchrophasor measurement units (PMUS), placed nearer to the generator bus, are used to detect and classify the disturbances into stressed conditions and different faults. The proposed backup protection has been implemented on the two-bus power system with a source and load at Bus-1 and Bus-2, respectively, in the MATLAB/Simulink platform. The result analysis of various disturbance scenarios shows that the proposed backup protection (in case the existing protection (over current protection) fails) detects and classifies the disturbances accurately, regardless of the current direction. Thus, the proposed protection is suitable to realize reliable numerical protection.
- 4 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
A Novel Backup Protection to Realize Reliable Numerical Protection
This paper proposes a novel backup protection to realize reliable numerical protection using the current index and power factor quantities. These quantities, estimated by the synchrophasor measurement units (PMUS), placed nearer to the generator bus, are used to detect and classify the disturbances into stressed conditions and different faults. The proposed backup protection has been implemented on the two-bus power system with a source and load at Bus-1 and Bus-2, respectively, in the MATLAB/Simulink platform. The result analysis of various disturbance scenarios shows that the proposed backup protection (in case the existing protection (over current protection) fails) detects and classifies the disturbances accurately, regardless of the current direction. Thus, the proposed protection is suitable to realize reliable numerical protection.
- 4 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Power Control of Offshore Grid by Frequency Matching for a Dfig Wind Power Farm Connected Hvdc System Under Voltage Fluctuations
The offshore wind farm is one of the green energy technologies for power production in remote areas. The effective medium of power transmission from the offshore to the far away shore grid of more than 50 Km is feasible only with the help of the HVDC link for economical purposes. This paper proposes a novel power control technique of an offshore DFIG wind power farm (ODWPF) by injection of mitigating current at the shore VSC station of an HVDC link along with constant voltage/frequency ($\mathrm{V} / \mathrm{f}$) operation at the auxiliary grid. The HVDC link connected offshore wind farm is equipped with a line commutated converter (LCC) at the sending end and a voltage source converter (VSC) at the end terminal. The offshore substation is operated at variable frequency and voltage, which allows the ODWPF to be operated at constant V/f operation. The speed of each turbine varies with respect to other turbines. The DFIG wind turbine can adjust the small variations in the wind speed, and thus the frequency at the offshore auxiliary grid can be controlled according to the HVDC system voltage and frequency. The complete system is simulated in the PSCAD/EMTDC environment.
- 4 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Power Control of Offshore Grid by Frequency Matching for a Dfig Wind Power Farm Connected Hvdc System Under Voltage Fluctuations
The offshore wind farm is one of the green energy technologies for power production in remote areas. The effective medium of power transmission from the offshore to the far away shore grid of more than 50 Km is feasible only with the help of the HVDC link for economical purposes. This paper proposes a novel power control technique of an offshore DFIG wind power farm (ODWPF) by injection of mitigating current at the shore VSC station of an HVDC link along with constant voltage/frequency ($\mathrm{V} / \mathrm{f}$) operation at the auxiliary grid. The HVDC link connected offshore wind farm is equipped with a line commutated converter (LCC) at the sending end and a voltage source converter (VSC) at the end terminal. The offshore substation is operated at variable frequency and voltage, which allows the ODWPF to be operated at constant V/f operation. The speed of each turbine varies with respect to other turbines. The DFIG wind turbine can adjust the small variations in the wind speed, and thus the frequency at the offshore auxiliary grid can be controlled according to the HVDC system voltage and frequency. The complete system is simulated in the PSCAD/EMTDC environment.
- Open Access
- 25 May 2025
- Published by Atlantis Press SARL
- p. 892-904
Voltage Sag Reduction in a Grid Tied Solar Photovoltaic Plant by Fractional Order Based STATCOM
- 25 May 2025
- Published by Atlantis Press SARL
- p. 892-904
Open AccessVoltage Sag Reduction in a Grid Tied Solar Photovoltaic Plant by Fractional Order Based STATCOM
- Open Access
- 27 February 2025
- Published by Universal Wiser Publisher Pte. Ltd in Contemporary Mathematics
- p. 1414-1433
Enhancing Voltage Stability and Power Quality in Hybrid MPPT Algorithm Based SPV-Wind Hybrid Microgrid System Tied Utility Grid Integrating Modified STATCOM
Voltage sags can lead to equipment malfunction, decreased performance, and operational disruptions. They are typically caused by short circuits, motor start-ups, or sudden load increases, affecting power system reliability. Voltage stability of the proposed system has been improved by implementing modified Static Synchronous Compensator (m-STATCOM) by reducing voltage sags resulting power quality of the proposed system has been enhanced during breakdowns in electrical systems. The Voltage-Source Inverter (VSI) technology of m-STATCOM allows for quick reaction. At the Point of Common Coupling (PCC), it stabilizes voltage to avoid equipment damage from voltage fluctuations. m-STATCOM boosts reactive power regulation, renewable energy stability, and fault ride-through for dependable grid performance. Hybrid Incremental Conductance and Ripple Correlation Control (INC-RCC) for MPPT in PV and wind farms tracks Maximum Power Point Tracking (MPPT) under diverse situations to reduce power losses and fluctuations resulting improve efficiency and reaction speed as compared to Penguin Search (PS) optimization. System stability and performance improve with the Solar Photovoltaic (SPV)-Wind farm and Sinusoidal Pulse Width Modulation (SPWM)-Voltage Source Inverter (VSI)-based m-STATCOM controller. This integrated solution assists in minimizing LLG failure voltage drops.1KW SPV and 2.5 kW wind farm hybrid system connected to 400 V, 50 Hz utility grid integrated to the SPWM-VSI based m-STATCOM controller has been designed using MATLAB/Simulink.
- 27 February 2025
- Published by Universal Wiser Publisher Pte. Ltd in Contemporary Mathematics
- p. 1414-1433
Open AccessEnhancing Voltage Stability and Power Quality in Hybrid MPPT Algorithm Based SPV-Wind Hybrid Microgrid System Tied Utility Grid Integrating Modified STATCOM
Voltage sags can lead to equipment malfunction, decreased performance, and operational disruptions. They are typically caused by short circuits, motor start-ups, or sudden load increases, affecting power system reliability. Voltage stability of the proposed system has been improved by implementing modified Static Synchronous Compensator (m-STATCOM) by reducing voltage sags resulting power quality of the proposed system has been enhanced during breakdowns in electrical systems. The Voltage-Source Inverter (VSI) technology of m-STATCOM allows for quick reaction. At the Point of Common Coupling (PCC), it stabilizes voltage to avoid equipment damage from voltage fluctuations. m-STATCOM boosts reactive power regulation, renewable energy stability, and fault ride-through for dependable grid performance. Hybrid Incremental Conductance and Ripple Correlation Control (INC-RCC) for MPPT in PV and wind farms tracks Maximum Power Point Tracking (MPPT) under diverse situations to reduce power losses and fluctuations resulting improve efficiency and reaction speed as compared to Penguin Search (PS) optimization. System stability and performance improve with the Solar Photovoltaic (SPV)-Wind farm and Sinusoidal Pulse Width Modulation (SPWM)-Voltage Source Inverter (VSI)-based m-STATCOM controller. This integrated solution assists in minimizing LLG failure voltage drops.1KW SPV and 2.5 kW wind farm hybrid system connected to 400 V, 50 Hz utility grid integrated to the SPWM-VSI based m-STATCOM controller has been designed using MATLAB/Simulink.
- 22 May 2024
- Published by Wiley in International Journal of Circuit Theory and Applications
- Vol. 53 (1) , 409-426
Power Harmonic Suppression based direct vector control for robust DFIG operation during grid voltage distortions
This paper proposes a Power Harmonic Suppression (Damping) (PHS) based reference current generation scheme, which focuses on simultaneous mitigation of harmonic pulsations in electromagnetic torque, stator real and reactive powers, and DC‐link voltage while retaining sinusoidal stator and grid currents and unity power factor at grid side. The crux of this PHS method lies in its ability to eliminate the harmonic powers developed in the DFIG stator and grid at 100Hz, 200Hz, 300Hz, 400Hz, and 600 Hz owing to second, fifth, and seventh harmonic grid voltages. This is achieved as a result of the elimination of natural fluxes developed in the DFIG air gap due to second, fifth, and seventh harmonic distortions in grid voltage. For this, a single concurrent reference current generation technique is developed for RSC and GSC to mitigate the oscillations of electromagnetic torque, stator real and reactive powers, and ripples in DC‐link voltage. Further, the reference rotor currents (positive, negative, fifth, and seventh sequence) are compared with the actual rotor currents using a PI controller to retain sinusoidal stator and grid currents. The proposed scheme's efficacy is validated with PSCAD/EMTDC simulations and using OPAL‐RT OP4510 real‐time simulator, on a 2.3 kVA DFIG.
- 22 May 2024
- Published by Wiley in International Journal of Circuit Theory and Applications
- Vol. 53 (1) , 409-426
Power Harmonic Suppression based direct vector control for robust DFIG operation during grid voltage distortions
This paper proposes a Power Harmonic Suppression (Damping) (PHS) based reference current generation scheme, which focuses on simultaneous mitigation of harmonic pulsations in electromagnetic torque, stator real and reactive powers, and DC‐link voltage while retaining sinusoidal stator and grid currents and unity power factor at grid side. The crux of this PHS method lies in its ability to eliminate the harmonic powers developed in the DFIG stator and grid at 100Hz, 200Hz, 300Hz, 400Hz, and 600 Hz owing to second, fifth, and seventh harmonic grid voltages. This is achieved as a result of the elimination of natural fluxes developed in the DFIG air gap due to second, fifth, and seventh harmonic distortions in grid voltage. For this, a single concurrent reference current generation technique is developed for RSC and GSC to mitigate the oscillations of electromagnetic torque, stator real and reactive powers, and ripples in DC‐link voltage. Further, the reference rotor currents (positive, negative, fifth, and seventh sequence) are compared with the actual rotor currents using a PI controller to retain sinusoidal stator and grid currents. The proposed scheme's efficacy is validated with PSCAD/EMTDC simulations and using OPAL‐RT OP4510 real‐time simulator, on a 2.3 kVA DFIG.