GLGabrielle G. Long

Gabrielle G. Long

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Gabrielle G. Long has a total of 16 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Density changes in amorphous silicon induced by swift heavy ions

    by Sjoerd Roorda, Stéphanie Codsi, Amélie Lacroix, Gabrielle G. Long, Fan Zhang, Steven J. Weigand, Christina Trautmann

    Pure and gold-doped amorphous silicon membranes were irradiated with swift heavy ions (75 MeV Ag or 1.1 GeV Au ions) and studied using small-angle x-ray scattering. The samples that were irradiated with 1.1 GeV Au ions produced a scattering pattern consistent with core-shell-type ion tracks of 2.0 ± 0.1 nm (core) and 7.0 ± 0.3 nm (total) radius irrespective of gold doping, consistent with radii previously observed [9]. The density in the core is nearly 4% different from that of the surrounding material. The entire track (core + shell) is slightly less dense than the surrounding material, yielding an expansion or hammering constant A of 0.036±0.003 nm2 per ion track, consistent with the macroscopic “hammering” deformation. No tracks were found in samples irradiated with 75 MeV Ag ions, and no signature specific to the gold impurity doping could be observed.


  • Versatile Collimating Crystal Stage for a Bonse-Hart USAXS Instrument

    by J. Ilavsky, D. Shu, P. R. Jemian, G. G. Long

    An advanced ultra‐small‐angle X‐ray scattering (USAXS) instrument, using the Bonse‐Hart design and installed at APS, is a robust and reliable instrument, providing a scattering vector (q) range of nearly 4 decades (0.00015 to 1 Å−1), an intensity dynamic range of up to 9 decades, standard‐less absolute intensity calibration, and USAXS imaging capabilities. This type of instrument typically uses channel‐cut crystals in both the collimating (before sample) and analyzing (after sample) stages. The optical surfaces of these crystals are finished by etching processes, which leave an orange‐peel surface texture, which would compromise the USAXS imaging quality. Therefore optics with highly polished surfaces using separated crystals in both collimating and analyzing stages were developed. A novel design of the optics and mechanical stage uses a fixed gap between the two separated collimating crystals in which a triangular section of the first crystal is removed, allowing for a variable number (1, 2, 4, 6, or 8) of crystal reflections for X‐ray energies between 7 and 19 keV. The number of reflections is selected by lateral translation of the collimating crystal pair. Rotational alignment of the second crystal in the pair by an artificial channel‐cut crystal mechanism, implemented with a novel high‐stiffness weak link actuated by both a picomotor and a piezo‐electric transducer, provides the capability to align or adjust an assembly of crystals to achieve the same performance as a single channel‐cut crystal with integral weak link. The arrangement of both crystals is held on a removable base that can be remounted with precision within the Si(111) rocking curve on a three‐point kinematic mount. Additional tilt adjustments are also provided for initial alignment. This monochromator has proven to be highly robust with respect to motions and vibrations, as well as flexible with respect to selection of number of reflections, and its performance directly resulted in the highly reliable performance of the whole USAXS instrument.


  • Small-angle scattering by dislocations

    by Robb Thomson, L. E. Levine, G. G. Long

    It is shown that the small-angle scattering of X-rays or neutrons by dislocations within a deformed metal, which are partially ordered into wall-like structures, is characterized by several factors. Principally these are associated with: (i) a single dislocation or dipole; (ii) the dislocation configuration in the plane of the wall; and (iii) the distribution of dislocations across the wall thickness. With the assumption of isotropic elasticity, small-angle scattering will be sensitive only to the edge components of the dislocations. The scattered intensity is dominated by scattering from dislocations that lie perpendicular to the scattering vector, \bf q, and reaches a maximum when \bf q is normal to the slip plane of these dislocations. Above a particular |\bf q |, the scattered intensity is sensitive only to the total edge dislocation content of the scattering dislocations (i.e. scattering is incoherent), while, below this value, the scattering is dominated by how the dislocations are distributed in walls. For walls normal to their slip planes, the configuration factor will reflect the dislocation distribution in the plane of the wall, while, for walls parallel to their slip planes, the distribution in the thickness direction will be visible. Therefore, even though a deformed material is composed of complicated dislocation structures, only those segments conforming to these rather strict prescriptions will be singled out for scattering, and, by adjusting the beam/slip system geometry, many parameters of the microstructure can be determined experimentally.


  • Anisotropic Microstructure of Plasma-Sprayed Deposits

    by J. Lavsky, G.G. Long, A.J. Allen, L. Leblanc, M. Prystay, C. Moreau

    The microstructure of plasma-sprayed deposits (PSD) is dominated by two void systems - interlamellar pores and intralamellar cracks - each with a different anisotropy. Varying anisotropics and crack-to-pore ratios within PSDs are responsible for the anisotropic properties observed in the deposits. While it is difficult to apply standard porosity measurement techniques to the assessment of anisotropic microstructures, novel techniques utilizing different approaches have recently emerged. Image analysis (IA) of impregnated PSD samples is the most direct technique. The structure is stabilized by impregnation and then polished and imaged. The limitations of IA lie in the impregnation process and in the subsequent polishing. Also, the images produced from anisotropic materials can be difficult to interpret quantitatively. The technique of small-angle neutron scattering (SANS) has recently been successfully applied to the study of PSDs. The major advantages of SANS are that it does not require sample preparation and that quantitative information can be gotten about the separate crack and pore systems, including their distinctive anisotropics. However, the relationship between the SANS results and the underlying structure is more complex and less intuitive than for IA, and the availability of the SANS technique is limited by the need to have access to a powerful neutron source, such as a reactor. Also, the two techniques present different views of the microstructure because of the different sensitivities in different parts of the size range. This paper compares results from IA and SANS from a set of thick plasma-sprayed ceramic deposits possessing a range of crack/pore microstructures, and discusses how the two techniques might complement one another.