VPVitsarut Primpray

Vitsarut Primpray

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Vitsarut Primpray has a total of 26 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Fabrication and Characterization of 3D-Printed Polylactide Composite Scaffolds with Modified Graphene

    by Worathep Khimlek, Jirawan Jindakeaw, Vitsarut Primpray, Chanpen Karuwan, Teruoki Tago, Paiboon Sreearunothai, Chariya Kaewsaneha, Adisorn Tuantranont, Pakorn Opaprakasit

    In this study, we introduce novel multifunctional biomaterial inks for extrusion-based 3D bioprinting to create scaffolds for potential tissue engineering. This study focuses on developing composite materials by incorporating alkyl ketene dimer (AKD)-modified graphene nanoplatelets (GP) into polylactide (PLA) using a solvent casting technique. GP was synthesized via electrolytic exfoliation in an aqueous poly(sodium 4-styrenesulfonate) solution and subsequently modified with AKD by ball milling to enhance dispersion and PLA compatibility. Physical and chemical characterization confirmed the successful synthesis and structural properties of the AKD-modified GP. PLA-GPD20 films containing 20 wt % AKD-modified GP exhibited significantly improved elongation at break and maintained tensile strength comparable to neat PLA. All biomaterial composite films exhibited high stiffness, as evidenced by glass transition temperatures above room temperature, and electrical conductivity in the semiconductor range. The results highlight the significant positive impact of AKD on the physical and electrical properties, as well as the printability, of the composites. The printability performance potential was evaluated using 10 wt % PLA-GPD20 biomaterial inks to generate scaffolds with different patterns. The mechanical testing of the printed scaffolds revealed that the tensile strength and modulus increased with the incorporation of GPD20. The printing orientation is an effective parameter for tuning the balance between stiffness and ductility; scaffolds printed at 90° exhibited higher Young’s modulus but lower elongation at yield and tensile strength than those printed at 45°. Furthermore, incorporating AKD into GP/PLA composites improved hydrophobicity. The results suggest that AKD-modified graphene composites hold substantial promise for the development of advanced multifunctional materials for tissue engineering applications.

  • Open Access

    Electrochemical Immunosensor for Point-of-Care Detection of Citrullinated Histone H3 Using Screen-Printed Graphene Electrodes and a Portable Potentiostat

    by Vitsarut Primpray, Wichayaporn Kamsong, Assawapong Sappat, Theeraphud Phunin, Anurat Wisitsoraat, Awirut Charoensappakit, Kritsanawan Sae-Khow, Asada Leelahavanichkul, Chanpen Karuwan

    Citrullinated histone H3 (CitH3) is an emerging biomarker for early sepsis diagnosis. However, its detection based on standard enzyme-linked immunosorbent assay (ELISA) suffers from long analysis time (4–5 h), expensive instruments, and the need for skilled operators, necessitating the development of alternative detection platforms. Herein, a portable electrochemical immunosensor for CitH3 determination was developed using a screen-printed graphene electrode coupled with a custom-designed potentiostat. CitH3 was detected via a sandwich immunoassay employing horseradish peroxidase–conjugated antibody and amperometric measurement in the presence of hydroquinone and hydrogen peroxide. Key fabrication and detection parameters were systematically optimized to achieve high analytical performance. Under optimal conditions, the immunosensor exhibited a linear detection range of 0.1–1000 ng mL–1 with a detection limit of 42.83 pg mL–1 and a quantification limit of 100.89 pg mL–1, enabling the discrimination between sepsis and nonsepsis conditions. Additionally, the developed method provided a lower detection limit and shorter processing time (2 h) compared with ELISA. It also demonstrated high selectivity against common serum interferents, satisfactory accuracy (recovery = 89.49–106.11%), and good repeatability (relative standard deviation < 10%). Analysis of clinical serum samples (n = 50) showed a high correlation coefficient with ELISA (r = 0.9861), and Bland–Altman analysis confirmed their good agreement. Furthermore, the assay diagnostic performance demonstrated 100% specificity with high sensitivity values of 90.01% and 81.25% for sepsis and severe sepsis cases, respectively. These results suggested the potential of the proposed portable electrochemical immunosensor as a practical tool for sepsis diagnosis.

  • Open Access

    An electrochemical aptamer-based biosensor for rapid and ultrasensitive detection of carbaryl by red blood cell-like MOFs

    by Hossein Khosropour, Mansoureh Keramat, Vitsarut Primpray, Chanpen Karuwan, Federico Tasca, Wanida Laiwattanapaisal


  • Disposable Electrochemical Sensor Based on MXene/Graphene Nanoplatelets/Ionic Liquid for the Determination of Anticancer Drug Imiquimod

    by Pramod K. Kalambate, Vitsarut Primpray, Wichayaporn Kamsong, Chanpen Karuwan, Wanida Laiwattanapaisal

    This study describes the development of a novel, ultrasensitive, and selective electrochemical sensor to determine imiquimod (IMQ) using a screen-printed carbon electrode (SPCE) modified with MXene (Ti3C2Tx), graphene nanoplatelets, and ionic liquid (Ti3C2Tx/GNPs/IL). This work reveals the synergistic effect of Ti3C2Tx, GNPs, and IL, where Ti3C2Tx and GNPs provide a large active electrode area and excellent electron transport, and IL exhibits remarkable electrocatalytic behavior. Benefiting from the excellent electrochemical properties of the composite, the developed sensing platform enabled superior electrochemical performance for IMQ in the broad linear range of 0.071–92.0 μM (R2 = 0.999) with a limit of detection (LOD) of 0.487 nM and a detection sensitivity of 7.558 μA μM−1 cm−2. Meanwhile, the sensor has shown good repeatability, reproducibility, stability, and anti-interference ability and has been subsequently used to detect IMQ in cream formulations with satisfactory recoveries (98.33%–99.34%) and lower relative standard deviations (<3%). The findings indicate that the newly developed sensor can contribute to the development of a portable, robust, and high-performance sensing strategy for multidisciplinary targets.


  • Open Access

    An alternative ready-to-use electrochemical immunosensor for point-of-care COVID-19 diagnosis using graphene screen-printed electrodes coupled with a 3D-printed portable potentiostat

    by Vitsarut Primpray, Wichayaporn Kamsong, Saithip Pakapongpan, Kanchanok Phochakum, Arissanan Kaewchaem, Assawapong Sappat, Anurat Wisitsoraat, Tanom Lomas, Adisorn Tuantranont, Chanpen Karuwan