Wen-Shuang Fan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Wen-Shuang Fan has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Fen-Chi Lin
Department of Ophthalmology, Kaohsiung Armed Forces General Hospital, Kaohsiung 80284, Taiwan
4 shared publications - Hsiang-Chen Wang
Department of Mechanical Engineering, National Chung Cheng University, Min Hsiung, Taiwan
4 shared publications - Ching-Yu Wang
Department of Ophthalmology, Dalin Tzu Chi Hospital, Buddhist Tzu Chi Medical Foundation, Chiayi 62247, Taiwan
3 shared publications - Hong-Thai Nguyen
Department of Mechanical Engineering, National Chung Cheng University, Chiayi 62102, Taiwan
3 shared publications - Shuan-Yu Huang
Department of Optometry, Central Taiwan University of Science and Technology, Taichung 406, Taiwan
2 shared publications - Yu-Ming Tsao
Department of Mechanical Engineering, National Chung Cheng University, Chiayi 62102, Taiwan
2 shared publications
Latest Publications
- Open Access
- 18 June 2024
- Published by MDPI AG in Diagnostics
- Vol. 14 (12) , 1285
Glaucoma Detection through a Novel Hyperspectral Imaging Band Selection and Vision Transformer Integration
Conventional diagnostic methods for glaucoma primarily rely on non-dynamic fundus images and often analyze features such as the optic cup-to-disc ratio and abnormalities in specific retinal locations like the macula and fovea. However, hyperspectral imaging techniques focus on detecting alterations in oxygen saturation within retinal vessels, offering a potentially more comprehensive approach to diagnosis. This study explores the diagnostic potential of hyperspectral imaging for glaucoma by introducing a novel hyperspectral imaging conversion technique. Digital fundus images are transformed into hyperspectral representations, allowing for a detailed analysis of spectral variations. Spectral regions exhibiting differences are identified through spectral analysis, and images are reconstructed from these specific regions. The Vision Transformer (ViT) algorithm is then employed for classification and comparison across selected spectral bands. Fundus images are used to identify differences in lesions, utilizing a dataset of 1291 images. This study evaluates the classification performance of models using various spectral bands, revealing that the 610–780 nm band outperforms others with an accuracy, precision, recall, F1-score, and AUC-ROC all approximately at 0.9007, indicating its superior effectiveness for the task. The RGB model also shows strong performance, while other bands exhibit lower recall and overall metrics. This research highlights the disparities between machine learning algorithms and traditional clinical approaches in fundus image analysis. The findings suggest that hyperspectral imaging, coupled with advanced computational techniques such as the ViT algorithm, could significantly enhance glaucoma diagnosis. This understanding offers insights into the potential transformation of glaucoma diagnostics through the integration of hyperspectral imaging and innovative computational methodologies.
- 18 June 2024
- Published by MDPI AG in Diagnostics
- Vol. 14 (12) , 1285
Open AccessGlaucoma Detection through a Novel Hyperspectral Imaging Band Selection and Vision Transformer Integration
Conventional diagnostic methods for glaucoma primarily rely on non-dynamic fundus images and often analyze features such as the optic cup-to-disc ratio and abnormalities in specific retinal locations like the macula and fovea. However, hyperspectral imaging techniques focus on detecting alterations in oxygen saturation within retinal vessels, offering a potentially more comprehensive approach to diagnosis. This study explores the diagnostic potential of hyperspectral imaging for glaucoma by introducing a novel hyperspectral imaging conversion technique. Digital fundus images are transformed into hyperspectral representations, allowing for a detailed analysis of spectral variations. Spectral regions exhibiting differences are identified through spectral analysis, and images are reconstructed from these specific regions. The Vision Transformer (ViT) algorithm is then employed for classification and comparison across selected spectral bands. Fundus images are used to identify differences in lesions, utilizing a dataset of 1291 images. This study evaluates the classification performance of models using various spectral bands, revealing that the 610–780 nm band outperforms others with an accuracy, precision, recall, F1-score, and AUC-ROC all approximately at 0.9007, indicating its superior effectiveness for the task. The RGB model also shows strong performance, while other bands exhibit lower recall and overall metrics. This research highlights the disparities between machine learning algorithms and traditional clinical approaches in fundus image analysis. The findings suggest that hyperspectral imaging, coupled with advanced computational techniques such as the ViT algorithm, could significantly enhance glaucoma diagnosis. This understanding offers insights into the potential transformation of glaucoma diagnostics through the integration of hyperspectral imaging and innovative computational methodologies.
- Open Access
- 14 July 2023
- Published by MDPI AG in Diagnostics
- Vol. 13 (14) , 2373
Detection of Hydroxychloroquine Retinopathy via Hyperspectral and Deep Learning through Ophthalmoscope Images
Hydroxychloroquine, also known as quinine, is primarily utilized to manage various autoimmune diseases, such as systemic lupus erythematosus, rheumatoid arthritis, and Sjogren’s syndrome. However, this drug has side effects, including diarrhea, blurred vision, headache, skin itching, poor appetite, and gastrointestinal discomfort. Blurred vision is caused by irreversible retinal damages and can only be mitigated by reducing hydroxychloroquine dosage or discontinuing the drug under a physician’s supervision. In this study, color fundus images were utilized to identify differences in lesions caused by hydroxychloroquine. A total of 176 color fundus images were captured from a cohort of 91 participants, comprising 25 patients diagnosed with hydroxychloroquine retinopathy and 66 individuals without any retinopathy. The mean age of the participants was 75.67 ± 7.76. Following the selection of a specific region of interest within each image, hyperspectral conversion technology was employed to obtain the spectrum of the sampled image. Spectral analysis was then conducted to discern differences between normal and hydroxychloroquine-induced lesions that are imperceptible to the human eye on the color fundus images. We implemented a deep learning model to detect lesions, leveraging four artificial neural networks (ResNet50, Inception_v3, GoogLeNet, and EfficientNet). The overall accuracy of ResNet50 reached 93% for the original images (ORIs) and 96% for the hyperspectral images (HSIs). The overall accuracy of Inception_v3 was 87% for ORIs and 91% for HSI, and that of GoogLeNet was 88% for ORIs and 91% for HSIs. Finally, EfficientNet achieved an overall accuracy of 94% for ORIs and 97% for HSIs.
- 14 July 2023
- Published by MDPI AG in Diagnostics
- Vol. 13 (14) , 2373
Open AccessDetection of Hydroxychloroquine Retinopathy via Hyperspectral and Deep Learning through Ophthalmoscope Images
Hydroxychloroquine, also known as quinine, is primarily utilized to manage various autoimmune diseases, such as systemic lupus erythematosus, rheumatoid arthritis, and Sjogren’s syndrome. However, this drug has side effects, including diarrhea, blurred vision, headache, skin itching, poor appetite, and gastrointestinal discomfort. Blurred vision is caused by irreversible retinal damages and can only be mitigated by reducing hydroxychloroquine dosage or discontinuing the drug under a physician’s supervision. In this study, color fundus images were utilized to identify differences in lesions caused by hydroxychloroquine. A total of 176 color fundus images were captured from a cohort of 91 participants, comprising 25 patients diagnosed with hydroxychloroquine retinopathy and 66 individuals without any retinopathy. The mean age of the participants was 75.67 ± 7.76. Following the selection of a specific region of interest within each image, hyperspectral conversion technology was employed to obtain the spectrum of the sampled image. Spectral analysis was then conducted to discern differences between normal and hydroxychloroquine-induced lesions that are imperceptible to the human eye on the color fundus images. We implemented a deep learning model to detect lesions, leveraging four artificial neural networks (ResNet50, Inception_v3, GoogLeNet, and EfficientNet). The overall accuracy of ResNet50 reached 93% for the original images (ORIs) and 96% for the hyperspectral images (HSIs). The overall accuracy of Inception_v3 was 87% for ORIs and 91% for HSI, and that of GoogLeNet was 88% for ORIs and 91% for HSIs. Finally, EfficientNet achieved an overall accuracy of 94% for ORIs and 97% for HSIs.
- Open Access
- 1 June 2023
- Published by MDPI AG in Journal of Personalized Medicine
- Vol. 13 (6) , 939
Optical Identification of Diabetic Retinopathy Using Hyperspectral Imaging
The severity of diabetic retinopathy (DR) is directly correlated to changes in both the oxygen utilization rate of retinal tissue as well as the blood oxygen saturation of both arteries and veins. Therefore, the current stage of DR in a patient can be identified by analyzing the oxygen content in blood vessels through fundus images. This enables medical professionals to make accurate and prompt judgments regarding the patient’s condition. However, in order to use this method to implement supplementary medical treatment, blood vessels under fundus images need to be determined first, and arteries and veins then need to be differentiated from one another. Therefore, the entire study was split into three sections. After first removing the background from the fundus images using image processing, the blood vessels in the images were then separated from the background. Second, the method of hyperspectral imaging (HSI) was utilized in order to construct the spectral data. The HSI algorithm was utilized in order to perform analysis and simulations on the overall reflection spectrum of the retinal image. Thirdly, principal component analysis (PCA) was performed in order to both simplify the data and acquire the major principal components score plot for retinopathy in arteries and veins at all stages. In the final step, arteries and veins in the original fundus images were separated using the principal components score plots for each stage. As retinopathy progresses, the difference in reflectance between the arteries and veins gradually decreases. This results in a more difficult differentiation of PCA results in later stages, along with decreased precision and sensitivity. As a consequence of this, the precision and sensitivity of the HSI method in DR patients who are in the normal stage and those who are in the proliferative DR (PDR) stage are the highest and lowest, respectively. On the other hand, the indicator values are comparable between the background DR (BDR) and pre-proliferative DR (PPDR) stages due to the fact that both stages exhibit comparable clinical-pathological severity characteristics. The results indicate that the sensitivity values of arteries are 82.4%, 77.5%, 78.1%, and 72.9% in the normal, BDR, PPDR, and PDR, while for veins, these values are 88.5%, 85.4%, 81.4%, and 75.1% in the normal, BDR, PPDR, and PDR, respectively.
- 1 June 2023
- Published by MDPI AG in Journal of Personalized Medicine
- Vol. 13 (6) , 939
Open AccessOptical Identification of Diabetic Retinopathy Using Hyperspectral Imaging
The severity of diabetic retinopathy (DR) is directly correlated to changes in both the oxygen utilization rate of retinal tissue as well as the blood oxygen saturation of both arteries and veins. Therefore, the current stage of DR in a patient can be identified by analyzing the oxygen content in blood vessels through fundus images. This enables medical professionals to make accurate and prompt judgments regarding the patient’s condition. However, in order to use this method to implement supplementary medical treatment, blood vessels under fundus images need to be determined first, and arteries and veins then need to be differentiated from one another. Therefore, the entire study was split into three sections. After first removing the background from the fundus images using image processing, the blood vessels in the images were then separated from the background. Second, the method of hyperspectral imaging (HSI) was utilized in order to construct the spectral data. The HSI algorithm was utilized in order to perform analysis and simulations on the overall reflection spectrum of the retinal image. Thirdly, principal component analysis (PCA) was performed in order to both simplify the data and acquire the major principal components score plot for retinopathy in arteries and veins at all stages. In the final step, arteries and veins in the original fundus images were separated using the principal components score plots for each stage. As retinopathy progresses, the difference in reflectance between the arteries and veins gradually decreases. This results in a more difficult differentiation of PCA results in later stages, along with decreased precision and sensitivity. As a consequence of this, the precision and sensitivity of the HSI method in DR patients who are in the normal stage and those who are in the proliferative DR (PDR) stage are the highest and lowest, respectively. On the other hand, the indicator values are comparable between the background DR (BDR) and pre-proliferative DR (PPDR) stages due to the fact that both stages exhibit comparable clinical-pathological severity characteristics. The results indicate that the sensitivity values of arteries are 82.4%, 77.5%, 78.1%, and 72.9% in the normal, BDR, PPDR, and PDR, while for veins, these values are 88.5%, 85.4%, 81.4%, and 75.1% in the normal, BDR, PPDR, and PDR, respectively.
- Open Access
- 5 October 2022
- Published by MDPI AG in Journal of Personalized Medicine
- Vol. 12 (10) , 1659
Design of a Functional Eye Dressing for Treatment of the Vitreous Floater
With the rapid development of display technology, related diseases of the human eye are also increasing day by day. Eye floaters are one of the diseases that affect humans. Herein, we present a functional ophthalmic dressing that can permeate the skin tissues of the eyes through oxygen and hydrogen to improve the symptoms of floaters. In clinical tests, the symptoms of sensory floaters improved in 28 patients, and the recovery rates of mild, moderate, and severe floaters were about 70%, 66.7%, and 83.3%, respectively.
- 5 October 2022
- Published by MDPI AG in Journal of Personalized Medicine
- Vol. 12 (10) , 1659
Open AccessDesign of a Functional Eye Dressing for Treatment of the Vitreous Floater
With the rapid development of display technology, related diseases of the human eye are also increasing day by day. Eye floaters are one of the diseases that affect humans. Herein, we present a functional ophthalmic dressing that can permeate the skin tissues of the eyes through oxygen and hydrogen to improve the symptoms of floaters. In clinical tests, the symptoms of sensory floaters improved in 28 patients, and the recovery rates of mild, moderate, and severe floaters were about 70%, 66.7%, and 83.3%, respectively.