ETEmmanuel Thienpont

Emmanuel Thienpont

*This is an algorithmically generated author record based on publicly available information.

Emmanuel Thienpont has a total of 8 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Correlation between frontal knee alignment and bone resection thicknesses during total knee arthroplasty without precision-enabling device: a retrospective study

    by Antoine Outrequin, Julie Manon, Amaury Ancion, Emmanuel Thienpont

    Introduction Proper knee alignment is critical for optimizing postoperative function and implant longevity in total knee arthroplasty (TKA). While robotic-assisted surgery offers precision in bone resections, most surgeons still rely on conventional instrumentation. This study evaluates the relationship between pre- and postoperative frontal knee alignment and bone resections in TKA performed without precision-enabling devices to establish a correlation between thickness of resection and frontal angular correction. Materials and methods This retrospective, single-center study analyzed data from patients undergoing TKA for end-stage osteoarthritis between June 2021 and April 2024. Intraoperative cuts were measured in a standard way. All procedures were performed by a single experienced surgeon without precision-enabling devices. Preoperative and six-week postoperative weight-bearing goniometry and anteroposterior (AP) radiographs were collected. The cohort consisted of 130 patients: 69 varus (= 177° HKA), 30 neutral (177°–183° HKA) and 31 valgus (= 183° HKA) knees. Patients were 36.9% male, with a mean age of 70.1 years (SD 8.2) and a BMI of 30.8 kg/m2 (SD 5.6). Hip-knee-ankle (HKA) angle, anatomical and mechanical tibiofemoral angles and joint line convergence angles (JLCA) were measured. Statistical analysis was conducted to determine correlations between resection measurements and angular parameters. Results The correlation between tibial resection (ΔT) and medial proximal tibial angle modification measured on goniometry (ΔMPTA(g)) followed a linear regression with a Spearman’s correlation coefficient (r = 0.553). A weak positive correlation was observed between ΔT and ΔMPTA on AP radiographs (r = 0.505), as well as between distal femoral resection (ΔDF) and lateral distal femoral angle modification (ΔLDFA(g)) on goniometry (r = 0.350) and on AP radiographs ΔLDFA(s) (r = 0.187). Conclusion This study suggests a moderate correlation between tibial resection thickness and angular correction in the coronal plane. However, the high variability observed indicates that surgical planning should not rely solely on this correlation.

  • Patient-Specific total knee arthroplasty for valgus osteoarthritis results in the use of minimal thickness polyethylene liners in low constraint implants

    by Nicholas Pagani, John Mazzocco, Emmanuel Thienpont, Eric Smith

    Background Correction of valgus knee deformity during total knee arthroplasty (TKA) can present numerous challenges. This study assessed the ability of a patient-specific knee design to allow easier intraoperative balancing of valgus knees in primary TKA. Materials and methods This study utilized a database consisting of de-identified computed tomography (CT) scans, low constraint knee designs (CR or PS), tibial and femoral implant dimensions, and implanted polyethylene (PE) thickness for all patients who underwent primary TKA with a patient-specific knee design provided by Conformis Inc. (Boston, MA, US). Data were analyzed for knee design, coronal deformity, native posterior and distal femoral offset, and PE thickness. Results A total of 26,227 cases were included, of which 25% had valgus deformity. In the PS group, the thinnest available PE (6 mm) was used for 64% of varus cases and 68% of valgus cases (P = 0.004). There was no difference in the distribution of thin (≤ 8 mm) and thick (> 8 mm) PE between varus or valgus knees with 0–5 degrees or > 10 degrees of deformity. Knees with varus deformity of 5–10 degrees were more likely to receive a thick PE than knees with valgus deformity of 5–10 degrees. For the CR group, the thinnest available PE (6 mm) was used in 77% of varus cases and 76% of valgus cases (P = 0.12). There was no difference in the distribution of thin and thick PE between varus or valgus knees regardless of deformity. Over 99% of CR knees received PE with thicknesses 8 mm or less, regardless of degree of preoperative varus or valgus deformity. Conclusions These results indicate that patient-specific instrumentation in TKA can facilitate valgus deformity correction without requiring increased PE thickness to achieve balancing. Patient-specific knee designs may reduce the difficulty of valgus knee correction while allowing the use of minimal thickness PEs in low constraint TKA implants.


  • Open Access

    Cutting-Edge Approaches in Arthroplasty: Before, during and after Surgery

    by Johannes Beckmann, David Barrett, Emmanuel Thienpont

    Personalised medicine was introduced in arthroplasty a long time ago with the aim of respecting each individual person for their unique personal characteristics in order to further improve outcomes