Thu Zar Ma Ma Moe Min
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Thu Zar Ma Ma Moe Min has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Apirak Pankiew
Thai Microelectronic Center (TMEC), National Science and Technology Development Agency, Chachoengsao 24000, Thailand
1 shared publication - Awirut Srisuwan
Thai Microelectronic Center (TMEC), National Science and Technology Development Agency, Chachoengsao 24000, Thailand
1 shared publication - Chamras Promptmas
Department of Biomedical Engineering, Faculty of Engineering, Mahidol University, Nakhon Pathom, Thailand
1 shared publication - Chanvit Leelayuwat
Centre for Research and Development of Medical Diagnostic Laboratories (CMDL), Faculty of Associated Medical Sciences, Khon Kaen University, Khon Kaen 40002, Thailand
1 shared publication - Cholatip Pongskul
Division of Nephrology, Department of Medicine, Faculty of Medicine, Khon Kaen University, Khon Kaen, Thailand
1 shared publication - Kondee Chauyrod
Thai Microelectronic Center (TMEC), National Science and Technology Development Agency, Chachoengsao 24000, Thailand
1 shared publication
Latest Publications
- Open Access
Biosensors Based on Ion-Sensitive Field-Effect Transistors for HLA and MICA Antibody Detection in Kidney Transplantation
This work demonstrates the ability of the Ion-Sensitive Field-Effect Transistor (ISFET)-based immunosensor to detect antibodies against the human leukocyte antigen (HLA) and the major histocompatibility complex class-I-related chain A (MICA). The sensing membrane of the ISFET devices was modified and functionalized using an APTES-GA strategy. Surface properties, including wettability, surface thickness, and surface topology, were assessed in each module of the modification process. The optimal concentrations of HLA and MICA proteins for the immobilization were 10 and 50 μg/mL. The dose-response curve showed a detection range of 1.98–40 µg/mL for anti-HLA and 5.17–40 µg/mL for anti-MICA. The analytical precision (%CV) was found to be 10.69% and 8.92% for anti-HLA and -MICA, respectively. Moreover, the electrical signal obtained from the irrelevant antibody was considerably different from that of the specific antibodies, indicating the specific binding of the relevant antibodies without noise interference. The sensitivity and specificity in the experimental setting were established for both antibodies (anti-HLA: sensitivity = 80.00%, specificity = 86.36%; anti-MICA: sensitivity = 86.67%, specificity = 88.89%). Our data reveal the potential of applying the ISFET-based immunosensor to the detection of relevant anti-HLA and -MICA antibodies, especially in the field of kidney transplantation.
Open AccessBiosensors Based on Ion-Sensitive Field-Effect Transistors for HLA and MICA Antibody Detection in Kidney Transplantation
This work demonstrates the ability of the Ion-Sensitive Field-Effect Transistor (ISFET)-based immunosensor to detect antibodies against the human leukocyte antigen (HLA) and the major histocompatibility complex class-I-related chain A (MICA). The sensing membrane of the ISFET devices was modified and functionalized using an APTES-GA strategy. Surface properties, including wettability, surface thickness, and surface topology, were assessed in each module of the modification process. The optimal concentrations of HLA and MICA proteins for the immobilization were 10 and 50 μg/mL. The dose-response curve showed a detection range of 1.98–40 µg/mL for anti-HLA and 5.17–40 µg/mL for anti-MICA. The analytical precision (%CV) was found to be 10.69% and 8.92% for anti-HLA and -MICA, respectively. Moreover, the electrical signal obtained from the irrelevant antibody was considerably different from that of the specific antibodies, indicating the specific binding of the relevant antibodies without noise interference. The sensitivity and specificity in the experimental setting were established for both antibodies (anti-HLA: sensitivity = 80.00%, specificity = 86.36%; anti-MICA: sensitivity = 86.67%, specificity = 88.89%). Our data reveal the potential of applying the ISFET-based immunosensor to the detection of relevant anti-HLA and -MICA antibodies, especially in the field of kidney transplantation.