JYJiahao Yue

Jiahao Yue

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Jiahao Yue has a total of 10 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Study the Influence of Cable Breakage on Wind-Induced Vibration Characteristics of the Curved Beam Unilateral Stayed Bridge

    by Shuang Zhao, Yi Shi, Jiahao Chen, Zhitao Yan, Bin Zhang, Xueqin Zhang, Zhenqiang Wang

    Existing studies have found that curved beam unilateral stayed bridges (CBUSB) have a risk of cable breakage under the design wind velocity. To ensure structural wind-induced vibration security, it is necessary to study the wind-induced vibration characteristics of CBUSBs considering the influence of the impact load due to the cable breakage. Based on the aerodynamic coefficients determined by a wind tunnel test and the established impact load model, parametric analyses of important CBUSBs’ characteristics (beam curvature and cable arrangement scheme) and the location of the cable breakage are carried out to assess the influence of cable breakage on the time-domain statistical values and frequency-domain distribution characteristics of wind-induced vibration response. The DAF, considering the influence of cable breakages on the wind-induced vibration peak value of CBUSBs, is proposed through dynamic analysis. Study results show that, with increasing curvature, under the two-modes action of wind loads and impact loads, the fluctuation component of the CBUSB is changed, resulting in a smaller proportion of resonant response. For CBUSBs with unilateral or bilateral cable arrangements, their wind-induced vibration behavior is significantly different. The former have dynamic characteristics and the latter have quasi-static characteristics. The breakage of the shortest cable at 7/33 to 7/22 of the curved beam length and its symmetry part significantly increases the wind-induced peak response of CBUSBs. The DAF recommended values can consider the amplification effect of wind-induced vibration due to the cable breakage.


  • Open Access

    Sectional Model Wind Tunnel Test and Research on the Wind-Induced Vibration Response of a Curved Beam Unilateral Stayed Bridge

    by Shuang Zhao, Jiahao Chen, Jiahao Yue, Zhitao Yan, Jun Liu, Bin Zhang, Jianfeng Chen

    The linear curve distribution of the beam and the asymmetrical layout of the stay cables may have beneficial or adverse influences on cable-stayed bridges. Sectional model wind tunnel tests and numerical simulations were used to analyze the influence of these two factors on the wind-induced vibration characteristics of a curved beam unilateral stayed bridges (CBUSB) and the interaction between its stay cables and curved beams. According to the basic similarity law, the sectional models of a CBUSB example were designed and manufactured. The aerodynamic force and wind-induced vibration of the models were measured in an atmospheric boundary wind tunnel laboratory to obtain the aerodynamic coefficient and displacement, respectively. Based on the wind tunnel test results, the verified finite element model was used to determine the displacement, acceleration, and cable tension of the CBUSB excited by the buffeting force under 5 curvature cases and 4 cable layout cases. Then, band-pass filter technology and fast Fourier transform technology were used to analyze the influence of these two parameters on the wind-induced vibration characteristics of the CBUSB. Results show that the CBUSB had good aerodynamic stability in the wind tunnel at low and high wind speeds. With increasing curvature, the high-order modal vibration and modal coupling vibration of the CBUSB may be generated. The frequency, the proportion of wind-induced vibration response components, and the distribution characteristics of spectrum energy of CBUSB will be affected by 4 cable layout schemes. Cables arranged on both sides of the bridge and near the center of curvature can improve pedestrian comfort and reduce wind-induced vibration, respectively. Affected by the interaction between cable and bridge, the cable and bridge transmit their own vibration to each other, both of which contain the response components of each other.


  • Open Access

    Wind-Induced Vibration Coefficient of Landscape Tower with Curved and Twisted Columns and Spiral Beams Based on Wind Tunnel Test Data

    by Shuang Zhao, Chengtao Zhang, Jiahao Yue, Zhitao Yan, Jun Liu, Bin Zhang, Bowei Liu

    The complex aerodynamic shape and structural form affect the wind-induced vibration coefficient β of landscape towers with a twisted column and spiral beam (short for LTs). To clarify the β distribution characteristics, evaluate the applicability of existing load codes, and provide accurate design wind loads, wind tunnel tests and numerical simulations were carried out on a LT. The LT’s aerodynamic coefficients and wind-induced responses were measured using rigid sectional and aeroelastic models. Furthermore, the displacement wind-induced vibration coefficient βd and inertial load wind-induced vibration coefficient βi(z) of the LT were calculated from these measured data. Combined with test data and a finite element model, the impacts of the wind speed spectrum type, the structural damping ratio ξ, and the peak factor g on β of the LT are analyzed. The accuracy of β of the LT calculated by Chinese and American load codes was examined and given the correction method. The results showed that the wind yaw angle had a significant impact on βd of the LT, which cannot be neglected in current load codes. The abrupt mass increase at the platform location makes the distribution characteristics of βi(z) of the LT different from conventional high-rise structures. The values of ξ and g have a significant impact on the calculation results of β, which are the key to the accurate design wind loads of LTs. The existing load codes are not suitable for LTs, and the correction method proposed in this paper can be used to improve them.