Virna Costa Onofri
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Virna Costa Onofri has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Thales Alexandre Carvalho Maia
Universidade Federal de Minas Gerais
2 shared publications - Braz de Jesus Cardoso Filho
Department of Electrical Engineering, Universidade Federal de Minas Gerais, Belo Horizonte 31270-901, Brazil
1 shared publication Elaine C. Carmo
Departament of Electrical Engineering, UFMG, Belo Horizonte, Brasil
1 shared publicationM. I. C. Santos
DALTEC, Belo Horizonte, Minas Gerais, Brasil
1 shared publicationThales A. C. Maia
Universidade Federal de Minas Gerais,Department of Electrical Engineering,Belo Horizonte,MG,Brazil
1 shared publication- Victor Flores Mendes
Department of Electrical Engineering, Federal University of Minas Gerais, Belo Horizonte, Minas Gerais, Brazil
1 shared publication
Latest Publications
- Open Access
Assessment of Non-Linear Modeling of Ladle Furnace Transformer Using Finite Element Analysis
This paper assesses a non-linear model of a three-phase Ladle Furnace Transformer, on slow front transients under no-load conditions. The model is designed to maintain accuracy and reduce complexity in estimating equivalent circuit parameters using three methods: analytical calculations, finite element analysis, and test measurement. The results reveal that analytical and finite element methods show discrepancies lower than 1%. Tests measurement, on the other hand, shows discrepancies higher than 5%, when compared to ones obtained from analytical and finite elements methods. Such discrepancy is particularly high in the estimation of leakage inductances and capacitances, and it is attributed mainly to differences between the transformer design and its actual assembly. Additionally, there are inherent inaccuracies in test procedures and instrumentation errors. The proposed model does not require difficult-to-obtain parameters and incorporates the non-linearity of magnetizing inductance, contributing to more accurate simulations. This simplified model is suitable for analyzing slow front transients and can be integrated into future studies addressing vacuum circuit breaker switching in electric arc furnace power systems, contributing to performance improvements in industrial applications. Additionally, the methodology for parameter determination can be applied to conventional power transformers, highlighting its versatility.
Open AccessAssessment of Non-Linear Modeling of Ladle Furnace Transformer Using Finite Element Analysis
This paper assesses a non-linear model of a three-phase Ladle Furnace Transformer, on slow front transients under no-load conditions. The model is designed to maintain accuracy and reduce complexity in estimating equivalent circuit parameters using three methods: analytical calculations, finite element analysis, and test measurement. The results reveal that analytical and finite element methods show discrepancies lower than 1%. Tests measurement, on the other hand, shows discrepancies higher than 5%, when compared to ones obtained from analytical and finite elements methods. Such discrepancy is particularly high in the estimation of leakage inductances and capacitances, and it is attributed mainly to differences between the transformer design and its actual assembly. Additionally, there are inherent inaccuracies in test procedures and instrumentation errors. The proposed model does not require difficult-to-obtain parameters and incorporates the non-linearity of magnetizing inductance, contributing to more accurate simulations. This simplified model is suitable for analyzing slow front transients and can be integrated into future studies addressing vacuum circuit breaker switching in electric arc furnace power systems, contributing to performance improvements in industrial applications. Additionally, the methodology for parameter determination can be applied to conventional power transformers, highlighting its versatility.
- 27 October 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Fault Analysis of a Ladle Furnace Transformer caused by Switching Transient and Ferroresonance
Electric Arc Furnace and Ladle Furnace transformers are very important in steel production industry. The overvoltages caused by vacuum circuit breaker during operation are very repetitive and can lead to failures and, consequently, large financial losses. The use of protection devices, as RC filters and surge arresters, can attenuate theses transient overvoltages. However, the clamping of one of the circuit breaker phases, which is a common event to occur in a system like this, can cause failure to one of the phases of the transformer protection system, due to ferroresonance effect. Operation of this transformer without one of the phases of the RC filter and surge arrest will likely lead it to failure after repetitive overvoltages. This paper presents the study and analysis of the cause of insulation failure in a no-load Ladle Furnace (LF) transformer caused by overvoltages during vacuum circuit breaker switching transients and by ferroresonance effects. The system of a real steel mill is modelled and will be used to perform simulations in Simulink/Matlab.
- 27 October 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Fault Analysis of a Ladle Furnace Transformer caused by Switching Transient and Ferroresonance
Electric Arc Furnace and Ladle Furnace transformers are very important in steel production industry. The overvoltages caused by vacuum circuit breaker during operation are very repetitive and can lead to failures and, consequently, large financial losses. The use of protection devices, as RC filters and surge arresters, can attenuate theses transient overvoltages. However, the clamping of one of the circuit breaker phases, which is a common event to occur in a system like this, can cause failure to one of the phases of the transformer protection system, due to ferroresonance effect. Operation of this transformer without one of the phases of the RC filter and surge arrest will likely lead it to failure after repetitive overvoltages. This paper presents the study and analysis of the cause of insulation failure in a no-load Ladle Furnace (LF) transformer caused by overvoltages during vacuum circuit breaker switching transients and by ferroresonance effects. The system of a real steel mill is modelled and will be used to perform simulations in Simulink/Matlab.
- 10 October 2022
- Published by SAGE Publications in Ironmaking & Steelmaking: Processes, Products and Applications
- Vol. 49 (10) , 976-994
Survey on the electric arc furnace and ladle furnace electric system
This paper presents a multidisciplinary review of electric arc furnace (EAF) and ladle furnace (LF) power plants in use for steel production. The EAF and LF systems comprise of critical electrical equipment that is prone to fail. Depending on the fault condition, a complete shutdown can emerge and consequently cause production loss. This paper presents, in view of an electrical system, each equipment that is needed in order to correctly operate an EAF and an LF. The state of art of each equipment is presented in this review, together with some discussion of the possible problems and solutions that can emerge in this kind of installation, including its impact on the steel production.
- 10 October 2022
- Published by SAGE Publications in Ironmaking & Steelmaking: Processes, Products and Applications
- Vol. 49 (10) , 976-994
Survey on the electric arc furnace and ladle furnace electric system
This paper presents a multidisciplinary review of electric arc furnace (EAF) and ladle furnace (LF) power plants in use for steel production. The EAF and LF systems comprise of critical electrical equipment that is prone to fail. Depending on the fault condition, a complete shutdown can emerge and consequently cause production loss. This paper presents, in view of an electrical system, each equipment that is needed in order to correctly operate an EAF and an LF. The state of art of each equipment is presented in this review, together with some discussion of the possible problems and solutions that can emerge in this kind of installation, including its impact on the steel production.
- 1 May 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Analysis of water pumps start powered by diesel generator
This study presents analysis of water pump starters in the event of a lack of electricity supply from the substation using a diesel generator. The voltage transients during the startup of these pumps will be observed, verifying the capacity of the diesel generator system to meet the necessary water flow demand to supply the process and propose solutions in case of exceeding a 15% voltage drop and / or exceeding power of generator. The behavior of the system with load application will also be analyzed.
- 1 May 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Analysis of water pumps start powered by diesel generator
This study presents analysis of water pump starters in the event of a lack of electricity supply from the substation using a diesel generator. The voltage transients during the startup of these pumps will be observed, verifying the capacity of the diesel generator system to meet the necessary water flow demand to supply the process and propose solutions in case of exceeding a 15% voltage drop and / or exceeding power of generator. The behavior of the system with load application will also be analyzed.
- 1 January 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 21608555,p. 1-6
Performance analysis of the RC clampers in switching off no load arc furnace transformers
This paper presents an over-voltage attenuation performance analysis of RC clampers and surge arresters during transients caused by switching off a no load transformer applied to an arc furnace. A Brazilian Industry actual system was simulated using the Matlab/Simulink software. The simulation results indicate that the adequate use of RC clampers can reduce the arresters operations and practically eliminates the re-strikes and repetitive transient over-voltages when using vacuum circuit breakers to switch the arc furnace transformer.
- 1 January 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 21608555,p. 1-6
Performance analysis of the RC clampers in switching off no load arc furnace transformers
This paper presents an over-voltage attenuation performance analysis of RC clampers and surge arresters during transients caused by switching off a no load transformer applied to an arc furnace. A Brazilian Industry actual system was simulated using the Matlab/Simulink software. The simulation results indicate that the adequate use of RC clampers can reduce the arresters operations and practically eliminates the re-strikes and repetitive transient over-voltages when using vacuum circuit breakers to switch the arc furnace transformer.