Keunwoo Park
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Keunwoo Park has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Jihoon Kweon
Department of Biomedical Engineering, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Republic of Korea
3 shared publications - Jihye Chae
Department of Biomedical Engineering, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Republic of Korea
3 shared publications - Joong Ho Ahn
Department of Otorhinolaryngology-Head and Neck Surgery, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Republic of Korea
3 shared publications Jaehee Hur
Affiliation Departments of Convergence Medicine, University of Ulsan College of Medicine, Asan Medical Center, Seoul, Korea
1 shared publication- Se Eun Yi
Department of Otorhinolaryngology-Head and Neck Surgery, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea
1 shared publication Yeonjoo Choi
Affiliation Department of Otorhinolaryngology-Head and Neck Surgery, University of Ulsan College of Medicine, Asan Medical Center, Seoul, Korea
1 shared publication
Latest Publications
- Open Access
- 10 November 2026
- Published by Springer Nature in Scientific Reports
CLNA: controllable latent space of non-prompt attributes for enhancing diversity in text-to-image synthesis
- 10 November 2026
- Published by Springer Nature in Scientific Reports
Open AccessCLNA: controllable latent space of non-prompt attributes for enhancing diversity in text-to-image synthesis
- Open Access
- 30 October 2026
- Published by JMIR Publications Inc. in JMIR Medical Informatics
- Vol. 14, e96134
Deep Learning–Assisted Diagnosis of Middle Ear Diseases in Otoendoscopy Across Clinician Experience Levels: Retrospective Reader Study
Background: Accurate diagnosis of middle ear diseases remains challenging due to the specialized nature of otoscopic interpretation and the global shortage of otolaryngologists. Objective: We aimed to evaluate the impact of a deep learning–based AI support system on the diagnostic performance of clinicians with varying levels of expertise, specifically focusing on its ability to bridge the gap between trainees and experts. Methods: In this retrospective reader study, a deep learning model (EfficientNet-B4) was developed using a large-scale dataset of 7335 endoscopic images. The model was designed for multi-class classification, simultaneously identifying primary categories (chronic otitis media, otitis media with effusion, or none [indicating the absence of the first two]) and secondary features (attic retraction, myringitis, otomycosis, and ventilation tube). To assess clinical impact, diagnostic performance was compared among 3 otology professors, 5 senior residents, and 5 junior residents using an independent clinical assessment set of 100 images. Participants performed diagnoses both with and without AI-generated predictions, with a time constraint of 1 minute per image to simulate real-world clinical pressure. Results: In 5-fold cross-validation, the deep learning model achieved 94.8% accuracy for the primary classification. The stand-alone AI achieved diagnostic accuracies ranging from 94.0% to 99.0% in the clinical assessment set. AI support significantly enhanced diagnostic accuracy across all groups for primary classification, with improvements of 11.0% for otology professors, 28.8% for senior residents, and 32.2% for junior residents ( P <.001). Accuracy increased from 78.7% to 89.7% for otology professors, from 65.0% to 93.8% for senior residents, and from 54.4% to 86.6% for junior residents. The accuracy gap between the most experienced (otology professors) and least experienced (junior residents) groups was reduced from 24.3% to 3.1%. For secondary categories, significant improvements were observed in diagnosing attic retraction and myringitis among residents. AI-supported accuracy for attic retraction was higher in senior residents than that of the stand-alone AI, although the 95% CIs overlapped substantially, so the difference was not statistically significant. Conclusions: Our findings demonstrate that deep learning–based AI support substantially improves the diagnostic accuracy of middle ear diseases, particularly for less experienced clinicians. By narrowing the performance gap between trainees and experts, this system shows high potential as a valuable adjunct for clinical decision-making and medical education in otology.
- 30 October 2026
- Published by JMIR Publications Inc. in JMIR Medical Informatics
- Vol. 14, e96134
Open AccessDeep Learning–Assisted Diagnosis of Middle Ear Diseases in Otoendoscopy Across Clinician Experience Levels: Retrospective Reader Study
Background: Accurate diagnosis of middle ear diseases remains challenging due to the specialized nature of otoscopic interpretation and the global shortage of otolaryngologists. Objective: We aimed to evaluate the impact of a deep learning–based AI support system on the diagnostic performance of clinicians with varying levels of expertise, specifically focusing on its ability to bridge the gap between trainees and experts. Methods: In this retrospective reader study, a deep learning model (EfficientNet-B4) was developed using a large-scale dataset of 7335 endoscopic images. The model was designed for multi-class classification, simultaneously identifying primary categories (chronic otitis media, otitis media with effusion, or none [indicating the absence of the first two]) and secondary features (attic retraction, myringitis, otomycosis, and ventilation tube). To assess clinical impact, diagnostic performance was compared among 3 otology professors, 5 senior residents, and 5 junior residents using an independent clinical assessment set of 100 images. Participants performed diagnoses both with and without AI-generated predictions, with a time constraint of 1 minute per image to simulate real-world clinical pressure. Results: In 5-fold cross-validation, the deep learning model achieved 94.8% accuracy for the primary classification. The stand-alone AI achieved diagnostic accuracies ranging from 94.0% to 99.0% in the clinical assessment set. AI support significantly enhanced diagnostic accuracy across all groups for primary classification, with improvements of 11.0% for otology professors, 28.8% for senior residents, and 32.2% for junior residents ( P <.001). Accuracy increased from 78.7% to 89.7% for otology professors, from 65.0% to 93.8% for senior residents, and from 54.4% to 86.6% for junior residents. The accuracy gap between the most experienced (otology professors) and least experienced (junior residents) groups was reduced from 24.3% to 3.1%. For secondary categories, significant improvements were observed in diagnosing attic retraction and myringitis among residents. AI-supported accuracy for attic retraction was higher in senior residents than that of the stand-alone AI, although the 95% CIs overlapped substantially, so the difference was not statistically significant. Conclusions: Our findings demonstrate that deep learning–based AI support substantially improves the diagnostic accuracy of middle ear diseases, particularly for less experienced clinicians. By narrowing the performance gap between trainees and experts, this system shows high potential as a valuable adjunct for clinical decision-making and medical education in otology.
- Open Access
- 10 October 2022
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 17 (10) , e0275846
Automated multi-class classification for prediction of tympanic membrane changes with deep learning models
Backgrounds and objective: Evaluating the tympanic membrane (TM) using an otoendoscope is the first and most important step in various clinical fields. Unfortunately, most lesions of TM have more than one diagnostic name. Therefore, we built a database of otoendoscopic images with multiple diseases and investigated the impact of concurrent diseases on the classification performance of deep learning networks. Study design: This retrospective study investigated the impact of concurrent diseases in the tympanic membrane on diagnostic performance using multi-class classification. A customized architecture of EfficientNet-B4 was introduced to predict the primary class (otitis media with effusion (OME), chronic otitis media (COM), and ’None’ without OME and COM) and secondary classes (attic cholesteatoma, myringitis, otomycosis, and ventilating tube). Results: Deep-learning classifications accurately predicted the primary class with dice similarity coefficient (DSC) of 95.19%, while misidentification between COM and OME rarely occurred. Among the secondary classes, the diagnosis of attic cholesteatoma and myringitis achieved a DSC of 88.37% and 88.28%, respectively. Although concurrent diseases hampered the prediction performance, there was only a 0.44% probability of inaccurately predicting two or more secondary classes (29/6,630). The inference time per image was 2.594 ms on average. Conclusion: Deep-learning classification can be used to support clinical decision-making by accurately and reproducibly predicting tympanic membrane changes in real time, even in the presence of multiple concurrent diseases.
- 10 October 2022
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 17 (10) , e0275846
Open AccessAutomated multi-class classification for prediction of tympanic membrane changes with deep learning models
Backgrounds and objective: Evaluating the tympanic membrane (TM) using an otoendoscope is the first and most important step in various clinical fields. Unfortunately, most lesions of TM have more than one diagnostic name. Therefore, we built a database of otoendoscopic images with multiple diseases and investigated the impact of concurrent diseases on the classification performance of deep learning networks. Study design: This retrospective study investigated the impact of concurrent diseases in the tympanic membrane on diagnostic performance using multi-class classification. A customized architecture of EfficientNet-B4 was introduced to predict the primary class (otitis media with effusion (OME), chronic otitis media (COM), and ’None’ without OME and COM) and secondary classes (attic cholesteatoma, myringitis, otomycosis, and ventilating tube). Results: Deep-learning classifications accurately predicted the primary class with dice similarity coefficient (DSC) of 95.19%, while misidentification between COM and OME rarely occurred. Among the secondary classes, the diagnosis of attic cholesteatoma and myringitis achieved a DSC of 88.37% and 88.28%, respectively. Although concurrent diseases hampered the prediction performance, there was only a 0.44% probability of inaccurately predicting two or more secondary classes (29/6,630). The inference time per image was 2.594 ms on average. Conclusion: Deep-learning classification can be used to support clinical decision-making by accurately and reproducibly predicting tympanic membrane changes in real time, even in the presence of multiple concurrent diseases.